SEARCH · Engineering Papers
Results for “dry cooling”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Marginal Soils Index Analysis & Geospatial Data
This data package contains output files associated with Mongird et al. (in prep) organized into four dataset directories. Each dataset is described in more detail below. 1. Marginal Soils Index Analysis Description: This folder contains a csv file with land needs and availability by state, power generating technology type, and scenario in 2050 when suitable siting areas are additionally constrained to areas with increasing levels of soil marginality. Files: msi_constrained_siting_availability_2050.csv Variables: Scenario - Projected 2050 scenario name State - US state abbreviation Technology - Generating technology type solar = solar photovoltaic gas_cc_re = natural gas combined cycle (recirculating cooling) wind = onshore wind gas_cc_ccs_re = natural gas combined cycle with carbon capture sequestration (recirculating cooling) gas_cc_dry = natural gas combined cycle with (dry cooling) gas_cc_pond = natural gas combined cycle with (pond cooling) coal_conv_ccs_re = conventional coal with carbon capture sequestration (recirculating cooling) Req_Capacity_MW - The amount of rated capacity required in 2050 of the given technology type in the given state and under the given scenario from the capacity expansion plan Req_Capacity_Factor - The assumed capacity factor (fraction between 0 and 1) for the given technology type in the given state and under the given scenario by the capacity expansion plan Req_Land_km2 - The amount of land required (in km-squared) to host the required generating capacity that is capable of meeting the specified capacity factor for the given technology type in the given state and under the given scenario Req_Energy_TWh - Product of Req_Capacity_MW, Req_Capacity_Factor, and 8760/1e6 for the given technology type in the given state and under the given scenario MSI_Case - The level of MSI that siting the given technology is additionally constrained to, where >0 means siting is additionally constrained to suitable land areas that have an MSI value greater than 0 >=1 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 1 >=2 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 2 >=3 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 3 Soil Attribute Rasters Description: This folder contains geospatial raster files for individual soil parameters upscaled to the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of non-missing 30m resolution values. All raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. Files: avg_cond_raster_ .tif - Average conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm max_cond_raster_ .tif - Maximum conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm min_ph_raster_ .tif- Min pH values across all soil horizons within a depth of 40 inches. avg_ph_raster_ .tif - Average pH value across all soil horizons within a depth of 40 inches. max_ph_raster_ .tif- Max pH value across all soil horizons within a depth of 40 inches. erosion_factor_raster_ .tif - Product of k-factor and percent slope flood_freq_raster_ .tif - Number of months of the year during which the area is commonly, frequently, or very frequently flooded. max_sar_raster_ .tif - Maximum sodium adsorption ratio across all horizons within a depth of 40 inches rock_frac_raster_ .tif - Fraction of the upper 6 inches of soil composed of rock fragments larger than 3 inches. temp_regime_raster_ .tif - Soil temperature regime with the following key: 0 = pergelic 1 = gelic 2 = cryic 3 = frigid 4 = isofrigid 5 = mesic 6 = isomesic 7 = thermic 8 = isothermic 9 = hyperthermic 10 =isohyperthermic Marginal Soils Index Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index at the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of 30m resolution. Both raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. A value of 0 indicates that there were no soil attributes present that indicate marginal soil. NA values indicate that data was unavailable or bodies of water. Files: marginal_soils_index_30m_raster.tif marginal_soils_index_1km_raster.tif Marginal Soils Index Resource Potential Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index + Resource Potential (MSI+RP) score at 1km resolution for geothermal, solar, and wind technologies. Raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. NA values indicate that the location is not suitable for siting the given technology due to policy, environmental, socioeconomic, topological, and other constraints regardless of soil marginality level. Areas with values greater than or equal to zero represent the product of the normalized MSI value and the normalized resource potential value. Files: geothermal_msi_ep_score_raster.tif solar_msi_ep_score_raster.tif wind_msi_ep_score_raster.tif Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830
Marginal Soils Index Analysis & Geospatial Data
This data package contains output files associated with the Mongird et al. paper entitled "Can US power grid expansion avoid prime agricultural lands?" and is organized into four dataset directories. Each dataset is described in more detail below. 1. Marginal Soils Index Analysis Description: This folder contains a csv file with land needs and availability by state, power generating technology type, and scenario in 2050 when suitable siting areas are additionally constrained to areas with increasing levels of soil marginality. Files: msi_constrained_siting_availability_2050.csv Variables: Scenario - Projected 2050 scenario name State - US state abbreviation Technology - Generating technology type solar = solar photovoltaic gas_cc_re = natural gas combined cycle (recirculating cooling) wind = onshore wind gas_cc_ccs_re = natural gas combined cycle with carbon capture sequestration (recirculating cooling) gas_cc_dry = natural gas combined cycle with (dry cooling) gas_cc_pond = natural gas combined cycle with (pond cooling) coal_conv_ccs_re = conventional coal with carbon capture sequestration (recirculating cooling) Req_Capacity_MW - The amount of rated capacity required in 2050 of the given technology type in the given state and under the given scenario from the capacity expansion plan Req_Capacity_Factor - The assumed capacity factor (fraction between 0 and 1) for the given technology type in the given state and under the given scenario by the capacity expansion plan Req_Land_km2 - The amount of land required (in km-squared) to host the required generating capacity that is capable of meeting the specified capacity factor for the given technology type in the given state and under the given scenario Req_Energy_TWh - Product of Req_Capacity_MW, Req_Capacity_Factor, and 8760/1e6 for the given technology type in the given state and under the given scenario MSI_Case - The level of MSI that siting the given technology is additionally constrained to, where >0 means siting is additionally constrained to suitable land areas that have an MSI value greater than 0 >=1 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 1 >=2 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 2 >=3 means siting is additionally constrained to suitable land areas that have an MSI value greater than or equal to 3 Soil Attribute Rasters Description: This folder contains geospatial raster files for individual soil parameters upscaled to the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of non-missing 30m resolution values. All raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. Files: avg_cond_raster_ .tif - Average conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm max_cond_raster_ .tif - Maximum conductivity of the saturation extract across all soil horizons within a depth of 40 inches, measured in mmhos/cm min_ph_raster_ .tif- Min pH values across all soil horizons within a depth of 40 inches. avg_ph_raster_ .tif - Average pH value across all soil horizons within a depth of 40 inches. max_ph_raster_ .tif- Max pH value across all soil horizons within a depth of 40 inches. erosion_factor_raster_ .tif - Product of k-factor and percent slope flood_freq_raster_ .tif - Number of months of the year during which the area is commonly, frequently, or very frequently flooded. max_sar_raster_ .tif - Maximum sodium adsorption ratio across all horizons within a depth of 40 inches rock_frac_raster_ .tif - Fraction of the upper 6 inches of soil composed of rock fragments larger than 3 inches. temp_regime_raster_ .tif - Soil temperature regime with the following key: 0 = pergelic 1 = gelic 2 = cryic 3 = frigid 4 = isofrigid 5 = mesic 6 = isomesic 7 = thermic 8 = isothermic 9 = hyperthermic 10 =isohyperthermic Marginal Soils Index Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index at the listed grid resolution (30m or 1 km). 1 km resolution files are a spatial average of 30m resolution. Both raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. A value of 0 indicates that there were no soil attributes present that indicate marginal soil. NA values indicate that data was unavailable or bodies of water. Files: marginal_soils_index_30m_raster.tif marginal_soils_index_1km_raster.tif Marginal Soils Index Resource Potential Rasters Description: This folder contains geospatial raster files of the Marginal Soils Index + Resource Potential (MSIxRP) score at 1km resolution for geothermal, solar, and wind technologies. Raster files use the USA Contiguous Albers Equal Area Conic (ESRI:102003) projection. NA values indicate that the location is not suitable for siting the given technology due to policy, environmental, socioeconomic, topological, and other constraints regardless of soil marginality level. Areas with values greater than or equal to zero represent the product of the normalized MSI value and the normalized resource potential value. Files: geothermal_msi_rp_score_raster.tif solar_msi_rp_score_raster.tif wind_msi_rp_score_raster.tif Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830
Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)
Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.
Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification
Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.
Future increase in compound soil drought-heat extremes exacerbated by vegetation greening
Compound soil drought and heat extremes are expected to occur more frequently with global warming, causing wide-ranging socio-ecological repercussions. Vegetation modulates air temperature and soil moisture through biophysical processes, thereby influencing the occurrence of such extremes. Global vegetation cover is broadly expected to increase under climate change, but it remains unclear whether vegetation greening will alleviate or aggravate future increases in compound soil drought-heat events. Here, using a suite of state-of-the-art model simulations, we show that the projected vegetation greening will increase the frequency of global compound soil drought-heat events, equivalent to 12-21% of the total increment at the end of 21st century. This increase is predominantly driven by reduced albedo and enhanced transpiration associated with increased leaf area. Although greening-induced transpiration enhancement has counteracting cooling and drying effects, the excessive water loss in the early growing season can lead to later soil moisture deficits, amplifying compound soil drought-heat extremes during the subsequent warm season. These changes are most pronounced in northern high latitudes and are dominated by the warming effect of CO 2 . Our study highlights the necessity of integrating vegetation biophysical effects into mitigation and adaptation strategies for addressing compound climate risks.
Atmospheric Variability Drives Anomalies in the Bering Sea Air–Sea Heat Exchange
Abstract High latitudes, including the Bering Sea, are experiencing unprecedented rates of change. Long-term Bering Sea warming trends have been identified, and marine heatwaves (MHWs), event-scale elevated sea surface temperature (SST) extremes, have also increased in frequency and longevity in recent years. Recent work has shown that variability in air–sea coupling plays a dominant role in driving Bering Sea upper-ocean thermal variability and that surface forcing has driven an increase in the occurrence of positive ocean temperature anomalies since 2010. In this work, we characterize the drivers of the anomalous surface air–sea heat fluxes in the Bering Sea over the period 2010–22 using ERA5 fields. We show that the surface turbulent heat flux dominates the net surface heat flux variability from September to April and is primarily a result of near-surface air temperature and specific humidity anomalies. The airmass anomalies that account for the majority of the turbulent heat flux variability are a function of wind direction, with southerly (northerly) wind advecting anomalously warm (cool), moist (dry) air over the Bering Sea, resulting in positive (negative) surface turbulent flux anomalies. During the remaining months of the year, anomalies in the surface radiative fluxes account for the majority of the net surface heat flux variability and are a result of anomalous cloud coverage, anomalous lower-tropospheric virtual temperature, and sea ice coverage variability. Our results indicate that atmospheric variability drives much of the Bering Sea upper-ocean temperature variability through the mediation of the surface heat fluxes during the analysis period. Significance Statement A long-term ocean warming trend and a recent increase in marine heatwaves in the Bering Sea have been identified. Previous work showed that anomalies in the exchange of heat between the ocean and the atmosphere were the primary driver of Bering Sea temperature variability, but the processes responsible for the heat exchange anomalies were unknown. In this work, we show that the atmosphere is the primary driver of anomalies in the Bering Sea air–sea heat exchange and therefore plays an important role in altering the thermal state of the Bering Sea. Our results highlight the importance of understanding more about how the ocean and the atmosphere interact at high latitudes and how this relationship will be affected by future climate change.
Powdermet CRADA for VELOCITI Voucher (CRADA Final Report)
NLR shall develop a model of an electric thermal energy storage (ETES) system in the System Advisor Model (SAM) framework that uses a salt and particle slurry developed by PowderMet as the thermal energy storage medium. The ETES shall consist of a recuperated sCO 2 Brayton cycle using 2-tank indirect thermal energy storage and an electric heater for heat input. The salt slurry uses chloride salt and operates at a maximum temperature of 500-720°C. The ETES uses dry air cooling. The salt slurry will be modeled as a sensible heat storage medium and as a latent heat storage medium. NLR will use the model to do parametric analysis of the factors affecting the performance (ex., round trip efficiency) of the ETES system. NLR will work with PowderMet to estimate the costs of system components and total system costs, with the levelized cost of electricity (LCOE) as the primary cost metric.
Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems
Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.
Development of a High-Efficiency Hybrid Dry Cooler System for sCO 2 Power Cycles in CSP Applications
This project addressed a major gap in supercritical CO 2 (sCO 2 ) power cycle research by focusing on the pre-cooler, a component that had received little attention despite its significant impact on cycle efficiency and plant economics. The team developed a compact dry cooler using brazed/diffusion-bonded microchannel passages paired with formed air-side fins, advancing the technology from TRL-2 toward commercial readiness. Compared to conventional fin-tube coolers, the design cuts installation footprint by roughly half for 10+ MWth systems while achieving better heat transfer and lower approach temperatures, translating into a projected LCOE reduction from 6.04 ¢/kWh to between 5.85 and 5.94 ¢/kWh. While fabrication of an aluminum MW-scale prototype revealed brazing and sealing challenges at larger scales, lessons learned informed a subsequent 1 MWth unit that was successfully built and delivered for integration into Sandia's Gen3 Particle Pilot Plant, advancing the technology to TRL-7 with a path toward TRL-8 pending successful testing.
Uncertainties in the effects of organic aerosol coatings on polycyclic aromatic hydrocarbon concentrations and their estimated health effects
We used the CAM5 model to examine how different particle-bound polycyclic aromatic hydrocarbon (PAH) degradation approaches affect the spatial distribution of benzo(a)pyrene (BaP). Three approaches were evaluated: NOA (no effect of OA coatings state on BaP), shielded (viscous OA coatings shield BaP from oxidation under cool and dry conditions) and ROI-T (viscous OA coatings slow BaP oxidation in response to temperature and humidity). Results show that BaP concentrations vary seasonally, influenced by emissions, deposition, transport and degradation approach, all of which are influenced by meteorological conditions. All simulations predict higher population-weighted global average (PWGA) fresh BaP concentrations during December–January–February (DJF) compared to June–July–August (JJA), due to increased emissions from household activities and reduced removal processes during colder months. The shielded and ROI-T approaches, which account for OA coatings, result in 2–6 times higher BaP concentrations in DJF compared to NOA. The shielded simulation predicts the highest PWGA fresh BaP concentration (1.3 ng m −3 ), with 90 % of BaP protected from oxidation. In contrast, the ROI-T approach forecasts lower concentrations in middle to low latitudes, as it assumes less effective OA coatings under warmer, more humid conditions. Evaluations against observed BaP concentrations show the shielded approach performs best, with a normalized mean bias (NMB) within ± 20 %. The combined incremental lifetime cancer risk (ILCR) for both fresh and oxidized PAHs is similar across simulations, emphasizing the importance of considering both forms in health risk assessments. This study highlights the critical role of accurate degradation approaches in PAH modeling.
Hydride Reprecipitation in Prototypical 17x17 PWR Fuel Rods after Simulated Vacuum Drying Conditions
Light water reactor (LWR) fuel rod cladding picks up hydrogen as it oxidizes in reactor. Once the hydrogen concentration exceeds the solubility limit, zirconium hydride platelets precipitate, generally in the circumferential direction. In preparation for dry storage, elevated temperatures can dissolve some of the circumferential hydrides, which during cooling can then reprecipitate in a direction perpendicular to the hoop stress (radially). From 2019 to 2024, ORNL published a series of reports that included metallographic observations of cladding after a thermal transient to 400°C followed by slow cooling. The simulated dry storage process was performed on three full-length 17x17 PWR fuel rods at their as-discharged rod internal pressure. There were two important observations from the metallographic examinations of these heat-treated rods: (1) the propensity for hydride reorientation is strongly influenced by nearby as-discharged precipitated hydrides, (2) the radial hydrides observed near the cladding inner diameter were often associated with cracks in the pellet. Subsequent modeling using the BISON fuel performance code that considered the effects of pellet cracks and pellet-cladding bonding observed in high-burnup fuel support the conclusion that pellet cracks enhance the local hoop stress in the cladding creating preferential sites for hydride reorientation, and that the influence of the pellet cannot be ignored in accurate fuel rod performance predictions.
Model Spread in Tropical Low Cloud Feedback Tied to Overturning Circulation Response to Warming
Among models participating in the Coupled Model Intercomparison Project phase 6 (CMIP6), here we show that the magnitude of the tropical low cloud feedback, which contributes considerably to uncertainty in estimates of climate sensitivity, is intimately linked to tropical deep convection and its effects on the tropical atmospheric overturning circulation. First, a reduction in tropical ascent area and an increased frequency of heavy precipitation result in high cloud reduction and upper-tropospheric drying, which increases longwave cooling and reduces subsidence weakening, favoring low cloud reduction (Radiation-Subsidence Pathway). Second, increased longwave cooling decreases tropospheric stability, which also reduces subsidence weakening and low cloudiness (Stability-Subsidence Pathway). In summary, greater high cloud reduction and upper-tropospheric drying (negative longwave feedback) lead to a more positive cloud feedback among CMIP6 models by contributing to a greater reduction in low cloudiness (positive shortwave feedback). Varying strengths of the two pathways contribute considerably to the intermodel spread in climate sensitivity.
Core design and performance of the Westinghouse lead fast reactor with UO 2 and MOX configurations
For this work, Westinghouse partnered with Argonne National Laboratory to design, model and optimize UO 2 - and MOX-fueled core designs for a medium size (950 MWt) Lead Fast Reactor that was pursued by Westinghouse. Using Argonne’s suite of reactor analysis codes together with Westinghouse fuel cost economic models, thousands of candidate cores were considered to achieve the economics-optimized cores presented in this paper. This optimization process considered detailed reactor physics, fuel performance, transient performance, and fuel economics models. The reactor performance of the resulting optimized UO 2 - and MOX-fueled core designs are described and compared in this paper. Both cores show fuel performance and transient behavior that is considered acceptable for the optimization presented herein, while further testing campaigns on material performance in high-temperature liquid lead will be required to confirm acceptability at the operating conditions chosen. A multi-batch strategy was selected for the UO 2 core for best fuel utilization with minimum fuel inventory costs. A single-batch fuel management was instead selected for the MOX core to maximize cycle length and minimize the impact of the longer refueling outage resulting from the higher decay heat of the discharged MOX fuel relative to the discharged UO 2 fuel, requiring a longer cooling time before dry-lift of discharged fuel could take place.
Elevated Forest Canopy Loss After Wildfires in Moist and Cool Forests in the Pacific Northwest
Wildfire frequency, intensity, and rate of spread are increasing across the Western U.S, resulting in more severe ecosystem impacts. Significant tree mortality can occur years after fire events, but this has received little attention compared to the immediate tree loss during a fire. We overlapped forest cover loss data with burn severity maps in the U.S. Pacific Northwest and quantified the total and delayed forest canopy loss after fires. We found that wildfires resulted in total canopy loss fraction (CLF) of 84%, 53%, and 22% within 3 years in areas burned at high, moderate, and low severity, respectively. The delayed canopy loss accounted for approximately 1/3, 1/2, and 2/3 of the total canopy loss for high, moderate, and low severity burns. Delayed canopy loss was greater in moist and cool areas than in dry and warm areas, likely because tree species in wetter environments were less adapted to survive when fires did occur. Across all forests, delayed CLF doubled as temperature increased from the climatological mean to a hot anomaly and tripled as vapor pressure deficit increased from a wet anomaly to a dry anomaly. Fire impacts on forest ecosystems are likely to intensify under future climate scenarios as wildfires expand into areas that historically experienced infrequent fires. The impacts can also be exacerbated by more frequent compound extreme events, such as droughts, heatwaves, and fires. These findings highlight the urgent need for targeted forest management strategies, particularly in mesic forests, to mitigate future fire impacts.
Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India
India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.
Thermoelectric heating and cooling–integrated dishwasher with thermal energy storage
Household dishwashers must address several performance goals: maximize washing and drying performance, while minimizing cycle duration, energy consumption, and water consumption. This study develops and examines a novel thermoelectric heating and cooling (TEHC) system with thermal energy storage applied to a household dishwasher (DW), aiming to improve the energy and drying performance of a commercially-available dishwasher while maintaining its washing performance, water consumption, and cycle duration. Experimental testing conducted on the novel TEHC-DW system demonstrates an 8.7% reduction in total energy consumption, lowering the per-cycle usage to 0.952 kWh, and a 40% reduction in energy consumption for internal water heating. The novel TEHC-DW system also demonstrates better drying performance, shortening the drying time by 42% to reach the same remaining moisture content as a commercially-available system. In addition, a resistance-capacitance network model is developed that predicts total drying time, total energy consumption, and the highest temperature reached in the tub (53.4 °C). The model accuracy is validated with experimental data (within ±1 K), and the model functions as a design tool via a parametric study to evaluate the next-generation design and the effect of the number of thermoelectric modules and thermoelectric driving force (i.e., current). Overall, this study demonstrates the potential for TEHC technology to improve energy efficiency and drying performance in household dishwashers.
Influence of Surface Aerosol Injection on Stratocumulus‐to‐Cumulus Transition: Cloud‐Surface Coupling and Background Aerosol Concentrations
The influence of surface aerosol injection on the stratocumulus‐to‐cumulus transition (SCT) is explored using large‐eddy simulations. We examine how cloud‐surface coupling (or the strength of the marine boundary layer (MBL) stratification that limits vertical turbulent mixing and convection) impacts the vertical transport of aerosols, and how injected aerosols influence cloud properties and associated cloud radiative effects during the SCT. By injecting aerosols at different stages of the SCT, noting that cloud is more decoupled from the surface over time due to entrainment warming, we find that cloud‐surface coupling significantly affects aerosol vertical transport. However, injection timing (before drizzle if any) does not notably affect the SCT and the efficiency of marine cloud brightening, because aerosol number concentrations due to injections at different times rapidly converge before the transition onset. By varying the background aerosol concentration, we find that injected aerosols can significantly extend the persistence of stratocumulus decks by suppressing precipitation in clean environments but have little impact on stratocumulus breakup with higher background aerosol concentrations due to saturated aerosol effects. In clean MBLs, the SCT‐delay‐induced increase in cloud fraction dominates the overall cooling effects in response to aerosols, followed by Twomey effects. These cooling effects are slightly offset by decreased liquid water path (LWP) due to entrainment drying. In polluted MBLs, the Twomey effect is more dominant, followed by cloud fraction adjustments, and these coolings are also partly offset by LWP adjustments. All the simulations are made in relatively small domains in which injected aerosols are homogenized over a short time scale.