The impact of low-Z and high-Z metal implants in IMRT: A Monte Carlo study of dose inaccuracies in commercial dose algorithms

Purpose: The aim of the study was to evaluate the dosimetric impact of low-Z and high-Z metallic implants on IMRT plans. Methods: Computed tomography (CT) scans of three patients were analyzed to study effects due to the presence of Titanium (low-Z), Platinum and Gold (high-Z) inserts. To eliminate artifacts in CT images, a sinogram-based metal artifact reduction algorithm was applied. IMRT dose calculations were performed on both the uncorrected and corrected images using a commercial planning system (convolution/superposition algorithm) and an in-house Monte Carlo platform. Dose differences between uncorrected and corrected datasets were computed and analyzed using gamma index (Pγ{sub <1}) and setting 2 mm and 2% as distance to agreement and dose difference criteria, respectively. Beam specific depth dose profiles across the metal were also examined. Results: Dose discrepancies between corrected and uncorrected datasets were not significant for low-Z material. High-Z materials caused under-dosage of 20%–25% in the region surrounding the metal and over dosage of 10%–15% downstream of the hardware. Gamma index test yielded Pγ{sub <1}>99% for all low-Z cases; while for high-Z cases it returned 91% < Pγ{sub <1}< 99%. Analysis of the depth dose curve of a single beam for low-Z cases revealed that, although the dose attenuation is altered inside the metal, it does not differ downstream of the insert. However, for high-Z metal implants the dose is increased up to 10%–12% around the insert. In addition, Monte Carlo method was more sensitive to the presence of metal inserts than superposition/convolution algorithm. Conclusions: The reduction in terms of dose of metal artifacts in CT images is relevant for high-Z implants. In this case, dose distribution should be calculated using Monte Carlo algorithms, given their superior accuracy in dose modeling in and around the metal. In addition, the knowledge of the composition of metal inserts improves the accuracy of the Monte Carlo dose calculation significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a source inside a catheter located at the skin surface with and without backscatter bolus; and a typical interstitial implant consisting of an HDR source in a catheter located at a depth of 0.5 cm. Commercially available HDR{sup 60}Co and {sup 192}Ir sources and a hypothetical {sup 169}Yb source were considered. The Geant4 Monte Carlo radiation transport code was used to estimate dose rate distributions for the configurations considered. These results were then compared to those obtained with the TG-43 dose calculation formalism. In particular, the influence of adding bolus material over the implant was studied. Results: For a 5 cm × 5 cm{sup 192}Ir superficial mould and 0.5 cm prescription depth, dose differences in comparison to the TG-43 method were about −3%. When the source was positioned at the skin surface, dose differences were smaller than −1% for {sup 60}Co and {sup 192}Ir, yet −3% for {sup 169}Yb. For the interstitial implant, dose differences at the skin surface were −7% for {sup 60}Co, −0.6% for {sup 192}Ir, and −2.5% for {sup 169}Yb. Conclusions: This study indicates the following: (i) for the superficial mould, no bolus is needed; (ii) when the source is in contact with the skin surface, no bolus is needed for either {sup 60}Co and {sup 192}Ir. For lower energy radionuclides like {sup 169}Yb, bolus may be needed; and (iii) for the interstitial case, at least a 0.1 cm bolus is advised for {sup 60}Co to avoid underdosing superficial target layers. For {sup 192}Ir and {sup 169}Yb, no bolus is needed. For those cases where no bolus is needed, its use might be detrimental as the lack of radiation scatter may be beneficial to the patient, although the 2% tolerance for dose calculation accuracy recommended in the AAPM TG-56 report is not fulfilled.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-280: Reconstructed Rectal Wall Dose Map-Based Verification of Rectal Dose Sparing Effect According to Rectum Definition Methods and Dose Perturbation by Air Cavity in Endo-Rectal Balloon

Purpose: Dosimetric effect and discrepancy according to the rectum definition methods and dose perturbation by air cavity in an endo-rectal balloon (ERB) were verified using rectal-wall (Rwall) dose maps considering systematic errors in dose optimization and calculation accuracy in intensity-modulated radiation treatment (IMRT) for prostate cancer patients. Methods: When the inflated ERB having average diameter of 4.5 cm and air volume of 100 cc is used for patient, Rwall doses were predicted by pencil-beam convolution (PBC), anisotropic analytic algorithm (AAA), and AcurosXB (AXB) with material assignment function. The errors of dose optimization and calculation by separating air cavity from the whole rectum (Rwhole) were verified with measured rectal doses. The Rwall doses affected by the dose perturbation of air cavity were evaluated using a featured rectal phantom allowing insert of rolled-up gafchromic films and glass rod detectors placed along the rectum perimeter. Inner and outer Rwall doses were verified with reconstructed predicted rectal wall dose maps. Dose errors and extent at dose levels were evaluated with estimated rectal toxicity. Results: While AXB showed insignificant difference of target dose coverage, Rwall doses underestimated by up to 20% in dose optimization for the Rwhole than Rwall at all dose range except for the maximum dose. As dose optimization for Rwall was applied, the Rwall doses presented dose error less than 3% between dose calculation algorithm except for overestimation of maximum rectal dose up to 5% in PBC. Dose optimization for Rwhole caused dose difference of Rwall especially at intermediate doses. Conclusion: Dose optimization for Rwall could be suggested for more accurate prediction of rectal wall dose prediction and dose perturbation effect by air cavity in IMRT for prostate cancer. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (MSIP) (Grant No. 200900420)

60 APPLIED LIFE SCIENCES↗

Comparison between DVH-based doses and ICRU point-based doses to the rectum and the bladder using CT-based high-dose rate brachytherapy to the cervix

Traditionally, doses to the bladder and the rectum were quantified using the bladder and rectal reference points defined by the International Commission on Radiation Units and Measurements (ICRU) in Report No. 38. In this study, we compared the 0.1-, 1.0-, 2.0-cc doses to the bladder and the rectum with the corresponding ICRU point doses using computed tomography (CT)-based planning in the intracavitary brachytherapy of carcinoma of the cervix. CT datasets of 136 consecutive intracavitary brachytherapy insertions between January and May 2015 were analyzed. The bladder and the rectum were contoured on consecutive CT slices as per Groupe Europeen de Curietherapie and the European Socie Ty for Radiotherapy and Oncology recommendations. Dose volume histograms were generated and doses of 0.1, 1.0, and 2.0 cc to the bladder and the rectum were recorded. ICRU bladder and rectal points were identified in the treatment plan. Mean doses of 0.1, 1.0, and 2.0 cc to the bladder was found to be 2.02, 1.57, and 1.35 times the ICRU point dose, respectively. The maximum dose received by the bladder was found to be 5.83 times the average ICRU point dose. Mean doses of 0.1, 1.0, and 2.0 cc to the rectum were found to be 1.12, 0.90, and 0.78 times the ICRU rectal point dose, respectively. The maximum dose received by the rectum was 4.79 times the average ICRU point dose. The Pearson correlation coefficient value (r) was found to be 0.639 for D2cc and ICRU bladder point values. The Pearson correlation coefficient value was found to be 0.752 for D2cc and ICRU rectal point values. Our results show that the ICRU bladder points underestimated the dose to the bladder, which is in agreement with other studies. ICRU rectal point doses were higher than the corresponding D2cc doses. However, there was a good correlation between D2cc and ICRU point doses for both the bladder and the rectum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-17A-08: The Relative Accuracy of 4D Dose Accumulation for Lung Radiotherapy Using Rigid Dose Projection Versus Dose Recalculation On Every Breathing Phase

Purpose: To investigate the accuracy of 4D dose accumulation using projection of dose calculated on the end-exhalation, mid-ventilation, or average intensity breathing phase CT scan, versus dose accumulation performed using full Monte Carlo dose recalculation on every breathing phase. Methods: Radiotherapy plans were analyzed for 10 patients with stage I-II lung cancer planned using 4D-CT. SBRT plans were optimized using the dose calculated by a commercially-available Monte Carlo algorithm on the end-exhalation 4D-CT phase. 4D dose accumulations using deformable registration were performed with a commercially available tool that projected the planned dose onto every breathing phase without recalculation, as well as with a Monte Carlo recalculation of the dose on all breathing phases. The 3D planned dose (3D-EX), the 3D dose calculated on the average intensity image (3D-AVE), and the 4D accumulations of the dose calculated on the end-exhalation phase CT (4D-PR-EX), the mid-ventilation phase CT (4D-PR-MID), and the average intensity image (4D-PR-AVE), respectively, were compared against the accumulation of the Monte Carlo dose recalculated on every phase. Plan evaluation metrics relating to target volumes and critical structures relevant for lung SBRT were analyzed. Results: Plan evaluation metrics tabulated using 4D-PR-EX, 4D-PR-MID, and 4D-PR-AVE differed from those tabulated using Monte Carlo recalculation on every phase by an average of 0.14±0.70 Gy, - 0.11±0.51 Gy, and 0.00±0.62 Gy, respectively. Deviations of between 8 and 13 Gy were observed between the 4D-MC calculations and both 3D methods for the proximal bronchial trees of 3 patients. Conclusions: 4D dose accumulation using projection without re-calculation may be sufficiently accurate compared to 4D dose accumulated from Monte Carlo recalculation on every phase, depending on institutional protocols. Use of 4D dose accumulation should be considered when evaluating normal tissue complication probabilities as well as in clinical situations where target volumes are directly inferior to mobile critical structures.

60 APPLIED LIFE SCIENCES↗

Comparison of calculated dose distributions reported as dose-to-water and dose-to-medium for intensity-modulated radiotherapy of nasopharyngeal cancer patients

Advanced dose calculation algorithms for radiation therapy treatment planning can report external beam photon dose 2-sided, in terms of dose-to-medium (D{sub m}) and dose-to-water (D{sub w}). The purpose of our study was to determinate the effect of D{sub w} and D{sub m} reporting modes built in Elekta Monaco treatment planning system on intensity-modulated radiotherapy dose distributions for patients with nasopharyngeal cancer. For 13 patients involved in this retrospective study, 2 plans were created: 1 using D{sub w} and another according to D{sub m} reporting mode. Treatment plans were normalized such that 100% planning target volume should be covered by 95% of prescribed dose. Dose-volume constraints were assigned according to international standards. The comparison between dose distributions was performed evaluating quantities important for respective volumes of interest. For target volumes, heterogeneity index and conformity index methodology were used along with the maximum dose concept. Also, for the comparisons over particular organ at risk, maximum dose or mean dose as well as dose-volume concepts were used. For all target volumes and majority of organs at risk, the differences between 2 reporting modes are statistically insignificant, but this is not the case for bony structured organs at risks: mandible and cochlea. It was observed that D{sub w} is higher than D{sub m} with mean difference of 9.91% (p = 0.000009) of the mandible volume covered with 70 Gy. The same trend was observed for left and right cochlea with difference in mean dose of 8.74% (p = 0.037) and 6.87% (p = 0.029), respectively. The comparative analysis of dosimetric parameters in this study shows that the selection of reporting modes in Monaco treatment planning system can produce dose differences up to 15% in high-density volumes such as mandible and cochlea, which might have clinical consequences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-196: Comparative Analysis of Surface Dose Measurements Using MOSFET Detector and Dose Predicted by Eclipse - AAA with Varying Dose Calculation Grid Size

Purpose: Skin dose can be the limiting factor and fairly common reason to interrupt the treatment, especially for treating head-and-neck with Intensity-modulated-radiation-therapy(IMRT) or Volumetrically-modulated - arc-therapy (VMAT) and breast with tangentially-directed-beams. Aim of this study was to investigate accuracy of near-surface dose predicted by Eclipse treatment-planning-system (TPS) using Anisotropic-Analytic Algorithm (AAA)with varying calculation grid-size and comparing with metal-oxide-semiconductor-field-effect-transistors(MOSFETs)measurements for a range of clinical-conditions (open-field,dynamic-wedge, physical-wedge, IMRT,VMAT). Methods: QUASAR™-Body-Phantom was used in this study with oval curved-surfaces to mimic breast, chest wall and head-and-neck sites.A CT-scan was obtained with five radio-opaque markers(ROM) placed on the surface of phantom to mimic the range of incident angles for measurements and dose prediction using 2mm slice thickness.At each ROM, small structure(1mmx2mm) were contoured to obtain mean-doses from TPS.Calculations were performed for open-field,dynamic-wedge,physical-wedge,IMRT and VMAT using Varian-21EX,6&15MV photons using twogrid-sizes:2.5mm and 1mm.Calibration checks were performed to ensure that MOSFETs response were within ±5%.Surface-doses were measured at five locations and compared with TPS calculations. Results: For 6MV: 2.5mm grid-size,mean calculated doses(MCD)were higher by 10%(±7.6),10%(±7.6),20%(±8.5),40%(±7.5),30%(±6.9) and for 1mm grid-size MCD were higher by 0%(±5.7),0%(±4.2),0%(±5.5),1.2%(±5.0),1.1% (±7.8) for open-field,dynamic-wedge,physical-wedge,IMRT,VMAT respectively.For 15MV: 2.5mm grid-size,MCD were higher by 30%(±14.6),30%(±14.6),30%(±14.0),40%(±11.0),30%(±3.5)and for 1mm grid-size MCD were higher by 10% (±10.6), 10%(±9.8),10%(±8.0),30%(±7.8),10%(±3.8) for open-field, dynamic-wedge, physical-wedge, IMRT, VMAT respectively.For 6MV, 86% and 56% of all measured values agreed better than ±20% for 1mm and 2.5mm grid-sizes respectively. For 18MV, 56% and 18% of all measured-values agreed better than ±20% for 1mm and 2.5mm grid-sizes respectively. Conclusion: Reliable Skin-dose calculations by TPS can be very difficult due to steep dose-gradient and inaccurate beam-modelling in buildup region.Our results showed that Eclipse over-estimates surface-dose.Impact of grid-size is also significant,surface-dose increased up to 40% from 1mm to 2.5mm,however, 1mm calculated-values closely agrees with measurements. Due to large uncertnities in skin-dose predictions from TPS, outmost caution must be exercised when skin dose is evaluated,a sufficiently smaller grid-size(1mm)can improve the accuracy and MOSFETs can be used for verification.

60 APPLIED LIFE SCIENCES↗

Data integration reveals key homeostatic mechanisms following low dose radiation exposure

The goal of this study was to define pathways regulated by low dose radiation to understand how biological systems respond to subtle perturbations in their environment and prioritize pathways for human health assessment. Using an in vitro 3-D human full thickness skin model, we have examined the temporal response of dermal and epidermal layers to 10 cGy X-ray using transcriptomic, proteomic, phosphoproteomic and metabolomic platforms. Bioinformatics analysis of each dataset independently revealed potential signaling mechanisms affected by low dose radiation, and integrating data shed additional insight into the mechanisms regulating low dose responses in human tissue. We examined direct interactions among datasets (top down approach) and defined several hubs as significant regulators, including transcription factors (YY1, MYC and CREB1), kinases (CDK2, PLK1) and a protease (MMP2). These data indicate a shift in response across time — with an increase in DNA repair, tissue remodeling and repression of cell proliferation acutely (24–72 h). Pathway-based integration (bottom up approach) identified common molecular and pathway responses to low dose radiation, including oxidative stress, nitric oxide signaling and transcriptional regulation through the SP1 factor that would not have been identified by the individual data sets. Significant regulation of key downstream metabolites of nitrative stress was measured within these pathways. Among the features identified in our study, the regulation of MMP2 and SP1 was experimentally validated. Our results demonstrate the advantage of data integration to broadly define the pathways and networks that represent the mechanisms by which complex biological systems respond to perturbation. - Highlights: • Low dose ionizing radiation altered homeostasis in 3D skin tissue model. • Global gene/protein/metabolite data integrated using complementary statistical approaches • Time and location-specific change in matrix regulation, ROS/RNS and DNA repair pathways detected • Low dose exposure alters metabolites involved in nitric oxide biosynthesis and wound healing. • Computationally predicted regulators of primary mechanisms were experimentally validated.

60 APPLIED LIFE SCIENCES↗

Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations

Here, an anthropomorphic phantom was equipped with three smartphones and irradiated in five separate exposure geometries in air using a 137 Cs source. The phantom was fitted internally with thermoluminescence dosimeters (TLD-700 chips) to measure the absorbed dose to the individual organs, while the absorbed doses in the phones were evaluated using optically stimulated luminescence (OSL) from the phones’ surface mount resistors (SMRs), along with reference dosimeters, namely Luxel OSL films and TLD-700 chips. The results indicate a strong dependence on the phone location with respect to the source due to shielding and scattering from the body. Dose conversion factors were calculated for several plausible exposure scenarios in order to correlate the absorbed doses measured in the phones to the average body dose received by the phantom. The measured conversion factors were compared with calculated factors using MCNP6.2 Monte Carlo simulations and an ADAM voxel phantom. Experiments were conducted to assess how the phone orientation and angle impacts the dose received by the phone components. The overall results indicate that the doses measured can vary significantly depending upon exposure geometry (including phone position and angle). However, in rotational irradiation symmetry, the phone doses lead to an over-estimate of the average whole-body dose by an average of ~10%, independent of the phone locations tested in this study. This result, if confirmed in future studies, may be acceptable for triage.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-12A-05: Radiation Dose in High-Pitch Pediatric Cardiac CTA: Correlation Between Lung Dose and CTDIvol, DLP, and Size Specific Dose Estimates (SSDE)

Purpose: To investigate the radiation dose for pediatric high pitch cardiac CTA Methods: A total of 14 cases were included in this study, with mean age of 6.2 years (ranges from 2 months to 15 years). Cardiac CTA was performed using a dual-source CT system (Definition Flash, Siemens). Tube voltage (70, 80 and 100kV) was chosen based on patient weight. All patients were scanned using a high-pitch spiral mode (pitch ranges from 2.5 to 3) with tube current modulation technique (CareDose4D, Siemens). For each case, the three dimensional dose distributions were calculated using a Monte Carlo software package (IMPACT-MC, CT Image GmbH). Scanning parameters of each exam, including tube voltage, tube current, beamshaping filters, beam collimation, were defined in the Monte Carlo calculation. Tube current profile along projection angles was obtained from projection data of each tube, which included data within the over-scanning range along z direction. The volume of lungs was segmented out with CT images (3DSlicer). Lung doses of all patients were calculated and compared with CTDIvol, DLP, and SSDE. Results: The average (range) of CTDIvol, DLP and SSDE of all patients was 1.19 mGy (0.58 to 3.12mGy), 31.54 mGy*cm (12.56 to 99 mGy*cm), 2.26 mGy (1.19 to 6.24 mGy), respectively. Radiation dose to the lungs ranged from 0.83 to 4.18 mGy. Lung doses correlated with CTDIvol, DLP and SSDE with correlation coefficients(k) at 0.98, 0.93, and 0.99. However, for the cases with CTDIvol less than 1mGy, only SSDE preserved a strong correlation with lung doses (k=0.83), while much weaker correlations were found for CTDIvol (k=0.29) and DLP (k=-0.47). Conclusion: Lung doses to pediatric patients during Cardiac CTA were estimated. SSDE showed the most robust correlation with lung doses in contrast to CTDIvol and DLP.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-08: Evaluation of Dose Mass Histogram as a More Representative Dose Description Method Than Dose Volume Histogram in Lung Cancer Patients

Purpose: Dose-volume-histogram (DVH) is widely used for plan evaluation in radiation treatment. The concept of dose-mass-histogram (DMH) is expected to provide a more representative description as it accounts for heterogeneity in tissue density. This study is intended to assess the difference between DVH and DMH for evaluating treatment planning quality. Methods: 12 lung cancer treatment plans were exported from the treatment planning system. DVHs for the planning target volume (PTV), the normal lung and other structures of interest were calculated. DMHs were calculated in a similar way as DVHs expect that the voxel density converted from the CT number was used in tallying the dose histogram bins. The equivalent uniform dose (EUD) was calculated based on voxel volume and mass, respectively. The normal tissue complication probability (NTCP) in relation to the EUD was calculated for the normal lung to provide quantitative comparison of DVHs and DMHs for evaluating the radiobiological effect. Results: Large differences were observed between DVHs and DMHs for lungs and PTVs. For PTVs with dense tumor cores, DMHs are higher than DVHs due to larger mass weighing in the high dose conformal core regions. For the normal lungs, DMHs can either be higher or lower than DVHs depending on the target location within the lung. When the target is close to the lower lung, DMHs show higher values than DVHs because the lower lung has higher density than the central portion or the upper lung. DMHs are lower than DVHs for targets in the upper lung. The calculated NTCPs showed a large range of difference between DVHs and DMHs. Conclusion: The heterogeneity of lung can be well considered using DMH for evaluating target coverage and normal lung pneumonitis. Further studies are warranted to quantify the benefits of DMH over DVH for plan quality evaluation.

60 APPLIED LIFE SCIENCES↗

Androgen Suppression Combined with Elective Nodal and Dose Escalated Radiation Therapy (the ASCENDE-RT Trial): An Analysis of Survival Endpoints for a Randomized Trial Comparing a Low-Dose-Rate Brachytherapy Boost to a Dose-Escalated External Beam Boost for High- and Intermediate-risk Prostate Cancer

Purpose: To report the primary endpoint of biochemical progression-free survival (b-PFS) and secondary survival endpoints from ASCENDE-RT, a randomized trial comparing 2 methods of dose escalation for intermediate- and high-risk prostate cancer. Methods and Materials: ASCENDE-RT enrolled 398 men, with a median age of 68 years; 69% (n=276) had high-risk disease. After stratification by risk group, the subjects were randomized to a standard arm with 12 months of androgen deprivation therapy, pelvic irradiation to 46 Gy, followed by a dose-escalated external beam radiation therapy (DE-EBRT) boost to 78 Gy, or an experimental arm that substituted a low-dose-rate prostate brachytherapy (LDR-PB) boost. Of the 398 trial subjects, 200 were assigned to DE-EBRT boost and 198 to LDR-PB boost. The median follow-up was 6.5 years. Results: In an intent-to-treat analysis, men randomized to DE-EBRT were twice as likely to experience biochemical failure (multivariable analysis [MVA] hazard ratio [HR] 2.04; P=.004). The 5-, 7-, and 9-year Kaplan-Meier b-PFS estimates were 89%, 86%, and 83% for the LDR-PB boost versus 84%, 75%, and 62% for the DE-EBRT boost (log-rank P<.001). The LDR-PB boost benefited both intermediate- and high-risk patients. Because the b-PFS curves for the treatment arms diverge sharply after 4 years, the relative advantage of the LDR-PB should increase with longer follow-up. On MVA, the only variables correlated with reduced overall survival were age (MVA HR 1.06/y; P=.004) and biochemical failure (MVA HR 6.30; P<.001). Although biochemical failure was associated with increased mortality and randomization to DE-EBRT doubled the rate of biochemical failure, no significant overall survival difference was observed between the treatment arms (MVA HR 1.13; P=.62). Conclusions: Compared with 78 Gy EBRT, men randomized to the LDR-PB boost were twice as likely to be free of biochemical failure at a median follow-up of 6.5 years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effective dose and persistence of Rhodamine-B in wild pig Vibrissae

Due to substantial ecological and economic damage attributed to wild pigs (Sus scrofa), there is international interest in using pharmaceutical baits to control populations. To assess the efficacy and specificity of baiting programs, one may use chemical biomarkers to evaluate uptake of pharmaceutical baits. In particular, Rhodamine B (RB) is known to be an effective biomarker in wild pigs. However, significant data gaps exist regarding the minimum effective dosage and the persistence of RB in wild pigs. To investigate this we used a controlled double-blind study, administering a one-time dose of RB at three treatment levels (5, 15, or 30 mg/kg) to 15 pigs, with five pigs per treatment group. Facial vibrissae were collected pre-RB ingestion as a control and every 2 weeks post-RB ingestion for 12 weeks. We examined samples for RB presence and used a generalized linear mixed model (GLMM) to determine the influence of treatment dose on persistence of RB. Additionally, we measured distance moved by the RB mark away from the vibrissae root and used a GLMM to assess movement rates of RB bands along growing vibrissae. Here, we found consistently greater persistence of RB in the 15 and 30 mg/kg treatments across the sampling period (p = 0.005 and p = <0.0001, respectively). A significant, positive movement trend in RB bands was observed within the 15 and 30mg/kg groups. Based on our results, a 15 mg/kg dosage can be considered a minimum effective dose for wild pigs and will reliably produce a detectable RB mark up to and likely beyond 12 weeks post-ingestion.

59 BASIC BIOLOGICAL SCIENCES↗

Dose to the Bladder Neck Is the Most Important Predictor for Acute and Late Toxicity After Low-Dose-Rate Prostate Brachytherapy: Implications for Establishing New Dose Constraints for Treatment Planning

Purpose: To identify an anatomic structure predictive for acute (AUT) and late (LUT) urinary toxicity in patients with prostate cancer treated with low-dose-rate brachytherapy (LDR) with or without external beam radiation therapy (EBRT). Methods and Materials: From July 2002 to January 2013, 927 patients with prostate cancer (median age, 66 years) underwent LDR brachytherapy with Iodine 125 (n=753) or Palladium 103 (n=174) as definitive treatment (n=478) and as a boost (n=449) followed by supplemental EBRT (median dose, 50.4 Gy). Structures contoured on the computed tomographic (CT) scan on day 0 after implantation included prostate, urethra, bladder, and the bladder neck, defined as 5 mm around the urethra between the catheter balloon and the prostatic urethra. AUT and LUT were assessed with the Common Terminology Criteria for Adverse Events, version4. Clinical and dosimetric factors associated with AUT and LUT were analyzed with Cox regression and receiver operating characteristic analysis to calculate area under the receiver operator curve (ROC) (AUC). Results: Grade ≥2 AUT and grade ≥2 LUT occurred in 520 patients (56%) and 154 patients (20%), respectively. No grade 4 toxicities were observed. Bladder neck D2cc retained a significant association with AUT (hazard ratio [HR], 1.03; 95% confidence interval [CI], 1.03-1.04; P<.0001) and LUT (HR, 1.01; 95% CI, 1.00-1.03; P=.014) on multivariable analysis. In a comparison of bladder neck with the standard dosimetric variables by use of ROC analysis (prostate V100 >90%, D90 >100%, V150 >60%, urethra D20 >130%), bladder neck D2cc >50% was shown to have the strongest prognostic power for AUT (AUC, 0.697; P<.0001) and LUT (AUC, 0.620; P<.001). Conclusions: Bladder neck D2cc >50% was the strongest predictor for grade ≥2 AUT and LUT in patients treated with LDR brachytherapy. These data support inclusion of bladder neck constraints into brachytherapy planning to decrease urinary toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for{sup 103}Pd and highest for {sup 131}Cs, except for the tumor where the average dose is highest for {sup 103}Pd and lowest for {sup 131}Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of dose size in single fraction spatially fractionated (grid) radiotherapy for melanoma

Purpose: To evaluate the impact of dose size in single fraction, spatially fractionated (grid) radiotherapy for selectively killing infiltrated melanoma cancer cells of different tumor sizes, using different radiobiological models. Methods: A Monte Carlo technique was employed to calculate the 3D dose distribution of a commercially available megavoltage grid collimator in a 6 MV beam. The linear-quadratic (LQ) and modified linear quadratic (MLQ) models were used separately to evaluate the therapeutic outcome of a series of single fraction regimens that employed grid therapy to treat both acute and late responding melanomas of varying sizes. The dose prescription point was at the center of the tumor volume. Dose sizes ranging from 1 to 30 Gy at 100% dose line were modeled. Tumors were either touching the skin surface or having their centers at a depth of 3 cm. The equivalent uniform dose (EUD) to the melanoma cells and the therapeutic ratio (TR) were defined by comparing grid therapy with the traditional open debulking field. The clinical outcomes from recent reports were used to verify the authors’ model. Results: Dose profiles at different depths and 3D dose distributions in a series of 3D melanomas treated with grid therapy were obtained. The EUDs and TRs for all sizes of 3D tumors involved at different doses were derived through the LQ and MLQ models, and a practical equation was derived. The EUD was only one fifth of the prescribed dose. The TR was dependent on the prescribed dose and on the LQ parameters of both the interspersed cancer and normal tissue cells. The results from the LQ model were consistent with those of the MLQ model. At 20 Gy, the EUD and TR by the LQ model were 2.8% higher and 1% lower than by the MLQ, while at 10 Gy, the EUD and TR as defined by the LQ model were only 1.4% higher and 0.8% lower, respectively. The dose volume histograms of grid therapy for a 10 cm tumor showed different dosimetric characteristics from those of conventional radiotherapy. A significant portion of the tumor volume received a very large dose in grid therapy, which ensures significant tumor cell killing in these regions. Conversely, some areas received a relatively small dose, thereby sparing interspersed normal cells and increasing radiation tolerance. The radiobiology modeling results indicated that grid therapy could be useful for treating acutely responding melanomas infiltrating radiosensitive normal tissues. The theoretical model predictions were supported by the clinical outcomes. Conclusions: Grid therapy functions by selectively killing infiltrating tumor cells and concomitantly sparing interspersed normal cells. The TR depends on the radiosensitivity of the cell population, dose, tumor size, and location. Because the volumes of very high dose regions are small, the LQ model can be used safely to predict the clinical outcomes of grid therapy. When treating melanomas with a dose of 15 Gy or higher, single fraction grid therapy is clearly advantageous for sparing interspersed normal cells. The existence of a threshold fraction dose, which was found in the authors’ theoretical simulations, was confirmed by clinical observations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescription doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged value of F{sub n} was 1.75/1.18. F{sub r} of 1.1 has been applied to gynecological cancer implants with expected acute reactions and outcomes as expected based on extensive experience with permanent implants. The calculation also gave the average Cs-131 dose of 126 Gy converted from the I-125 dose of 144 Gy for prostate implants. Conclusions: Inclusion of an allowance for resensitization led to significant dose corrections for Cs-131 permanent implants, and should be applied to prescription dose calculation. The adjustment of the Cs-131 prescription doses with resensitization correction for gynecological permanent implants was consistent with clinical experience and observations. However, the Cs-131 prescription doses converted from other implant doses can be further adjusted based on new experimental results, clinical observations, and clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗