Investigation of Power Flow in a Tapered Transmission Line Modification to HERMES -III using an Array of Dose- and Dose-rate Detectors in the Near- and Far-field
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract Electron counting can be performed algorithmically for monolithic active pixel sensor direct electron detectors to eliminate readout noise and Landau noise arising from the variability in the amount of deposited energy for each electron. Errors in existing counting algorithms include mistakenly counting a multielectron strike as a single electron event, and inaccurately locating the incident position of the electron due to lateral spread of deposited energy and dark noise. Here, we report a supervised deep learning (DL) approach based on Faster region-based convolutional neural network (R-CNN) to recognize single electron events at varying electron doses and voltages. The DL approach shows high accuracy according to the near-ideal modulation transfer function (MTF) and detector quantum efficiency for sparse images. It predicts, on average, 0.47 pixel deviation from the incident positions for 200 kV electrons versus 0.59 pixel using the conventional counting method. The DL approach also shows better robustness against coincidence loss as the electron dose increases, maintaining the MTF at half Nyquist frequency above 0.83 as the electron density increases to 0.06 e−/pixel. Thus, the DL model extends the advantages of counting analysis to higher dose rates than conventional methods.
Efforts to map atomic-scale chemistry at low doses with minimal noise using electron microscopes are fundamentally limited by inelastic interactions. Here, fused multi-modal electron microscopy offers high signal-to-noise ratio (SNR) recovery of material chemistry at nano- and atomic-resolution by coupling correlated information encoded within both elastic scattering (high-angle annular dark-field (HAADF)) and inelastic spectroscopic signals (electron energy loss (EELS) or energy-dispersive x-ray (EDX)). By linking these simultaneously acquired signals, or modalities, the chemical distribution within nanomaterials can be imaged at significantly lower doses with existing detector hardware. In many cases, the dose requirements can be reduced by over one order of magnitude. This high SNR recovery of chemistry is tested against simulated and experimental atomic resolution data of heterogeneous nanomaterials.
Slides for a presentation discussing methodologies and instruments used to test radiation in the lunar environment.
Estimates of organ-absorbed and committed doses to individuals exposed to radioactive materials via acute inhalation often rely on internal dose coefficients and detector responses from reference human computational models. To achieve more accurate dose assessments to United States Armed Forces service members exposed in-field, computational models with varying morphometric parameters representative of this population are necessary. The International Commission on Radiological Protection (ICRP) Publication 145 provides detailed mesh reference computational phantoms (MRCPs) for adult males and females, with morphometric parameters matched to the 50th percentile. Previously, these phantoms were 2D and 3D scaled to match desired height, mass, and secondary anthropomorphic parameters in the creation of the University of Florida / Memorial Sloan Kettering (UF/MSK) computational phantom library. To achieve body fat percentage targets required for accession into the US Armed Forces, muscle and fat volumes were adjusted accordingly, thus, creating the UF/Department of Defence computational phantom library presented in this study. A comprehensive library of mesh-type computational human phantoms was created, including 57 adult males and 49 adult females with morphometric parameters aligned with United States Armed Forces service members. Phantoms were restricted to a body mass index between 19 and 27.5, with body fat percentages below 26% for males and 36% for females. Specific absorbed fractions were computed for selected source and target combinations, demonstrating how variations in height and body mass influence energy absorption in target regions relative to the ICRP MRCPs. Radiation detector responses were also computed, revealing that higher body masses resulted in decreased registered counts in the detection volume. These findings highlight the importance of incorporating morphometric variability in computational phantoms to achieve more accurate dose assessments and radiation detection responses for United States Armed Forces service members who inhale radioactive materials in-field.
In this paper we discuss the latest developments for the FCC-ee interaction region layout, which represents one of the key ingredients to establish the feasibility of the FCC-ee. The collider has to achieve extremely high luminosities over a wide range of center-of-mass energies with two or four interaction points. The complex final focus hosted in the detector region has to be carefully designed, and the impact of beam losses and of any type of synchrotron radiation generated in the interaction region, including beamstrahlung, have to be evaluated in detail with simulations. We give an overview of the progress of the whole machine-detector-interface-related studies, among which are the updated mechanical model of the interaction region, the plans for a novel R&D activity of a IR mockup which is just starting, the collimation scheme and evaluation of beam induced backgrounds in the detectors, evaluation of radiation dose in the experimental area, and MDI integration with the detector.
Here the performance characteristics of single-crystalline diamond detectors at varying rates of heavy-ions below 50 MeV/u have been investigated. When tested with a 228 Th source, the energy resolution of these detectors is better than 1.0% FWHM for 8.8 MeV α-particles. With a slight reduction in the energy resolution, simultaneous timing resolution of 314 ps has been achieved. Isotopic resolution has been achieved up to magnesium using a diamond telescope at low rates with a 20 MeV/u 20 Ne + 12 C reaction. At moderate rates of direct 7.5 MeV/u 78 Kr, polarization effects are observed, though this effect can be diminished by increasing the applied voltage on the detector up to a limit. After an accumulated dose of 6.9 × 10 8 direct 78 Kr particles transmitting through the detector, a degradation in the energy resolution of the 8.8 MeV peak from 1.6% to 5.3% is observed, indicating that permanent damage has been done to the detector.
Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in a single pad configuration, 2 × 2 arrays, and related p-i-n diodes, and exposed to Co-60 sources for study. Devices were fabricated with a range of dopant layer concentrations, and for the arrays, a variety of inter-pad distances and distances from the active area to the edge. Measurements of capacitance versus voltage and leakage current versus voltage have been made to compare pre- and post-irradiation characteristics in gain layer depletion voltage, full bulk depletion voltage, and breakdown voltage. Conclusions are drawn regarding the effects of the gammas on both surface and interface states and on their contribution to acceptor removal through non-ionizing energy loss from Compton electrons or photoelectrons. Comparison of the performances of members of the set of devices can be used to optimize gain layer parameters.
We report spectroscopic-grade single crystal detectors can register the energies of individual X-ray interactions enabling photon-counting systems with superior resolution over traditional photoconductive X-ray detection systems. Current technical challenges have limited the preparation of perovskite semiconductors for energy-discrimination X-ray photon-counting detection. Here, this work reports the deployment of a spectroscopic-grade CsPbBr 3 Schottky detector under reverse bias for continuum hard X-ray detection in both the photocurrent and spectroscopic schemes. High surface barriers of approximate to ≈ 1 eV are formed by depositing solid bismuth and gold contacts. The spectroscopic response under a hard X-ray source is assessed in resolving the characteristic X-ray peak. The methodology in enhancing X-ray sensitivity by controlling the X-ray energies and flux, and voltage, is described. The X-ray sensitivity varies between a few tens to over 8000 μC Gy air -1 cm -2 . The detectable dose rate of the CsPbBr 3 detectors is as low as 0.02 nGy air s -1 in the energy discrimination configuration. Finally, the unbiased CsPbBr 3 device forms a spontaneous contact potential difference of about 0.7 V enabling high quality of the CsPbBr 3 single crystals to operate in "passive" self-powered X-ray detection mode and the X-ray sensitivity is estimated as 14 μC Gy air -1 cm -2 . The great potential of spectroscopic-grade CsPbBr 3 devices for X-ray photon-counting systems is anticipated in this work.
Recently, metal halide perovskites have emerged as promising semiconductor candidates for sensitive X-ray photon detection due to their suitable band gap energies, excellent charge transport properties, and low material cost afforded by their low-temperature solution-processing preparation. Furthermore, we report an improved methodology for single crystal growth and thermal and electrical properties of a two-dimensional (2D) layered halide material Rb 4 Ag 2 BiBr 9 , which has been identified as a potential candidate for X-ray radiation detection applications. The measured heat capacity for Rb 4 Ag 2 BiBr 9 implies that there are no structural phase transitions upon cooling. Temperature dependence of thermal transport measurements further suggests remarkably low thermal conductivities of Rb 4 Ag 2 BiBr 9 that are comparable to the lowest reported in literature. The bulk crystal resistivity is determined to be 2.59 × 10 9 Ω·cm from the current–voltage (I–V) curve. Density of trap states is estimated to be ~10 10 cm –3 using the space-charge-limited-current measurements. The fabricated Rb 4 Ag 2 BiBr 9 -based X-ray detector shows good operational stability with no apparent current drift, which may be ascribed to the 2D crystal structure of Rb 4 Ag 2 BiBr 9 . Finally, by varying the X-ray tube current to change the corresponding dose rate, the Rb4Ag2BiBr9 X-ray detector sensitivity is determined to be 222.03 μC Gy –1 cm –2 (at an electric field of E = 24 V/mm).
The Large Hadron Collider at CERN will undergo an upgrade inorder to increase its luminosity to7.5 × 10$^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosityduring this High-Luminosity running phase, starting around 2029,means a higher rate of proton-proton interactions, hence a largerionizing dose and particle fluence for the detectors. The currenttracking system of the CMS experiment will be fully replaced inorder to cope with the new operating conditions. Prototype planarpixel sensors for the CMS Inner Tracker with square50 μm × 50 μm and rectangular100 μm × 25 μm pixels read out by theRD53A chip were characterized in the lab and at the DESY-II testbeamfacility in order to identify designs that meet the requirements ofCMS during the High-Luminosity running phase. A spatial resolutionof approximately 3.4 μm (2 μm) is obtained using themodules with 50 μm × 50 μm(100 μm × 25 μm) pixels at the optimalangle of incidence before irradiation. After irradiation to a 1 MeVneutron equivalent fluence ofΦ$_{eq}$ = 5.3 × 10$^{15}$ cm$^{-2}$, a resolution of9.4 μm is achieved at a bias voltage of 800 V using a modulewith 50 μm × 50 μm pixel size. All modulesretain a hit efficiency in excess of 99% after irradiation tofluences up to 2.1 × 10$^{16}$ cm$^{-2}$. Further studies ofthe electrical properties of the modules, especially crosstalk, arealso presented in this paper.
The Criticality Accident Alarm System (CAAS) for the Uranium Processing Facility (UPF) provides coverage for two primary processing facilities. For UPF, detailed documentation and drawings of the design are readily available. While this design information allows for some CAAS modeling features to match the actual design with a high level of accuracy, assumptions and simplifications are necessary as it is unrealistic and unnecessary to replicate many aspects of the design. A set of modeling guidelines and techniques were used to develop consistency between the MCNP6 models. While ensuring conservatism, overly conservative choices must be avoided to demonstrate the minimum accident of concern can be detected. To ensure proper modeling choices were made for the final models, a group of parametric studies were performed to evaluate the impact on the dose rates detected at the individual detectors. Some of these modeling choices and/or associated parametric studies include: - Modeling the grid steel area above the detectors as homogeneous stainless steel and determining the impact on detectability with an increasing density. - Modeling the presence of equipment in close proximity to the CAAS detectors. - Determining an appropriate material density to represent miscellaneous items not specifically modeled. - Evaluating the impact of sprinkler activation. The results of UPF CAAS analyses show that the modeling assumptions made based on the detailed design and parametric studies are appropriate and demonstrate accurate yet conservative models have been developed for detecting minimum accident of concern within the UPF.
This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.
Skipper CCDs are a mature detector technology that has been suggested for future space telescope instruments requiring sub-electron readout noise in the near-ultraviolet to the near-infrared. While modern skipper CCDs inherit from the radiation-tolerant p-channel detectors developed by LBNL, the effects of high doses of ionizing radiation on skipper CCDs (such as those expected in space) remains largely unmeasured. We report preliminary results on the performance of p-channel skipper CCDs following irradiation with 217-MeV protons at the Northwestern Medicine Proton Center. The total nonionizing energy loss (NIEL) experienced by the detectors exceeds 6 years at the Sun-Earth Lagrange Point 2 (L2). We demonstrate that the skipper amplifier continues to function as expected following this irradiation. Owing to the low readout noise of these detectors, controlled irradiation tests can be used to sensitively characterize the charge transfer inefficiency, dark current, and the density and time constants of charge traps as a function of proton fluence. We conclude with a brief outlook toward future tests of these detectors at other proton and gamma-ray facilities.
The effects of 63 MeV proton and 60Co gamma irradiation on the operation of 4.3 μm cutoff nBn photodetectors are demonstrated separately, and both are shown to yield a total ionizing dose (TID) effect. The effect is shown here in an InAsSbBi nBn detector and has been observed in other bulk alloy nBn detectors, and is unusual as it is notably absent in superlattice nBn detectors. The non-antireflection coated detectors exhibit a pre-radiation quantum efficiency of 17% at 3.3 μm wavelength and a dark current density of 50 μA/cm2, or roughly 300× the Rule 07 expectation, at their ideal operating voltage of −0.4 V bias at 150 K. Step-wise proton irradiation and in situ measurement indicate that the dark current increases to about 400× Rule 07 at the highest proton dose level of 150 krad(Si) (9.10 × 1011 p+/cm2), while the quantum efficiency is degraded at a relatively faster rate than the majority of analogous detectors characterized by our lab. Both the photocurrent and dark current are also shown to exhibit a turn-on voltage magnitude reduction of 100 mV following either gamma or proton irradiation, a trend which is attributable to negative trapped charge at the barrier interface (TID effect). This theory is further supported by an observed capacitance density magnitude reduction with dose and affirmed with Silvaco TCAD simulations. Following both proton exposure and subsequent anneal and gamma exposure and subsequent anneal; dark current, photocurrent, and CV all approach their pre-radiation baseline values.
Here. a novel dual-reflection configuration is introduced for the International Tokamak Experimental Reactor (ITER) core x-ray spectrometer to fit the allocated space where it will be placed accompanied by moving the detectors backward to reduce the incident radiation dose. The highly oriented pyrolytic graphite, which has a mosaic structure of microscopic crystallites, is chosen for the front reflector motivated by higher x-ray throughput and stronger misalignment tolerance compared to the perfect crystal reflector. In the ITER core x-ray spectrometer, a combination of several reflector-deflected Lines of Sight (LOSs) and a direct LOS is proposed for the first time named X-Ray Crystal Spectroscopy Core (XRCS-Core). The system is optimized to observe lines from externally seeded xenon and the intrinsic tungsten impurity, meeting both port integration needs and measurement requirements. Its spectral performance is simulated using an analytical-raytracing mixed code——XRSA, showing good imaging quality with a spectral resolution higher than 8000. The XRCS-Core system is thought to be applicable in various ITER scenarios through the assessment taking into account the spectrometers’ specifications and the chosen lines’ emissivity in different plasma parameters.
For safe and reliable use of computer codes by the community, accuracy must be clearly evaluated. In particular, the nuclear reactor engineering and licensing field needs accurate tools for radiation shielding modeling. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is one such tool, with built-in variance reduction methods distributed within the SCALE code, and its validity is demonstrated in this report for the released version 6.2.4. Representative benchmarks corresponding to shielding analysis are selected for the validation study. Typical experimental results analyzed from those benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma doses, foil neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between experiment and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, MAVRIC agrees well with the experiment results. MAVRIC is also compared to Monte Carlo N-Particle (MCNP) calculations when available, and both codes generally produce good agreements within estimated uncertainties. The selected benchmarks are obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP Handbook), the Shielding Integral Benchmark Archive & Database (SINBAD), and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to incrementally expand the shielding validation suite incrementally.
Safe and reliable use of scientific and engineering computer codes requires validation for the types of applications in which they will be used. An example in the nuclear reactor engineering and licensing field is radiation transport employed in shielding analyses. The validity of computer codes for shielding applications is demonstrated in this report for SCALE version 6.3.0. Representative benchmarks corresponding to shielding analyses are selected for the validation study. Typical measurement results analyzed from these benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma dose rates, neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between measurement and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, the Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) radiation transport computer code with built-in variance reduction methods distributed with the SCALE computer code system agrees well with the measurement results. In selected benchmarks, MAVRIC is also compared to Monte Carlo N- Particle® (MCNP® ) 1 calculations. Both computer codes generally agree well within the estimated uncertainties. With the release of SCALE 6.3.0, Shift was integrated as an alternative transport solver in MAVRIC, denoted MAVRIC-Shift. Although the traditional MAVRIC using Monaco was used primarily in this validation study, many results have also been generated using MAVRIC-Shift. Agreement between MAVRIC-Monaco and MAVRIC-Shift is generally very good. The benchmarks presented in this report were obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook, the Shielding Integral Benchmark Archive & Database, and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to expand the shielding validation suite.