Engineering PapersSearch

SEARCH · Engineering Papers

Results for “diurnal shift in fire activities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Toward an AI-Powered Software Pipeline for Real-Time Tracking and Analysis of Wildfire and Smoke

Real-time tracking of wildfires and smoke is crucial for effective response, minimizing damage, protecting lives, and efficiently managing resources during fire emergencies. We develop a web-based AI-powered pipeline that detects wildfires in aerial video and estimates deployment-relevant behavior metrics, including cumulative burned area, burned-area growth rate, fire spread direction, and smoke dispersion. The system combines a YOLO-based detector with YCbCr-based fire segmentation, HSV-based smoke segmentation, Farneback optical flow, and centroid-based spatiotemporal tracking. Using ground sampling distance (GSD), pixel-level fire masks are converted to physical burned-area measurements by correlating fire pixel counts with camera altitude and tilt angle. We benchmark YOLO variants and non-YOLO baselines (GoogLeNet, CNN, DBN, Autoencoder, U-Net, and AlexNet) on the IEEE FLAME dataset and a newly created aerial frame dataset, Wildfire-DB. Cross-dataset evaluation uses a strict threshold-transfer protocol: decision thresholds are selected on FLAME validation and transferred unchanged to Wildfire-DB to quantify generalization under domain shift. YOLOv6 achieves the strongest cross-dataset frame-level fire detection on Wildfire-DB (ROC-AUC 0.8200, PR-AUC 0.8044, and transferred-threshold F1 0.7596). For tracking-oriented deployment requiring oriented localization, YOLO11-OBB provides the most reliable cross-dataset behavior among OBB-capable models while remaining computationally feasible. To analyze the feasibility of UAV deployment, we further measure inference efficiency using synchronized GPU and CPU power logs on a fixed workload of 1569 frames. YOLO-family models process the video in 5.73–12.47 seconds with net energy of 1247.28–1775.39 J, substantially lower latency and energy than heavier classification and reconstruction baselines. Overall, model optimality depends on operational objectives: YOLOv6 is best for cross-dataset detection robustness, whereas YOL...

Color segmentation

Tuning the Coordination Environment of Rh Single Atoms on Highly Dispersed Reducible Oxides for Enhanced Reverse Water-Gas Shift Performance

Controlling the dynamic mobility of catalyst surface active sites and their interactions with the surrounding environment is critical in generating active surfaces that directly influence the catalytic activity and selectivity. Here, we report a strategy for tailoring the dispersion and electronic environment of single atom Rh catalysts by decorating the alumina support with highly dispersed (HD) cerium and molybdenum oxides. The resulting catalysts exhibit markedly different behavior in the Reverse Water Gas Shift (RWGS) reaction. In particular, Rh/MoOx(HD)/Al2O3 maintains atomically dispersed Rh even at elevated temperatures (up to 400 °C), achieving CO selectivity of up to 100% and resists sintering via the formation of a newly developed structure featuring Rh single atoms embedded in MoOx clusters. In situ spectroscopy and microscopy analyses confirm the stabilization of Rh and the dynamic evolution of Rh–Mo coordination under reaction conditions. Our findings highlight the power of support modification in steering active site structure and activity, offering a pathway toward enhanced and tunable single atom catalysts for CO2 valorization.

CO selectivity

Fire Protection Design

The purpose of this project is to design the demolition and installation of a deluge valve swap from a DV-5 to a DV-5A valve.

99 GENERAL AND MISCELLANEOUS

Case study of UAS ignition of prescribed fire in a mixedwood on the William B. Bankhead National Forest, Alabama

Abstract Background For at least four decades, practitioners have recognized advantages of aerial versus ground ignition for maximizing the effectiveness of prescribed fires. For example, larger areas can be ignited in less time, or ignition energy may be variously targeted over an area in accordance with the uneven distribution of fuels. The maturation of wireless communication, geopositioning systems, and unmanned aerial systems (UAS) has enhanced those advantages, and UAS approaches also provide further advantages relative to helicopter ignitions, such as reduced risk to human safety, lower operating costs, and higher operational flexibility. In a long running study at the Bankhead National Forest in northcentral Alabama, prescribed fire has been used for nearly 20 years. Most of the burns have been hand-ignited via drip torches, while some have been aerially ignited via helicopter. In March 2022, for the first time, a UAS was used to ignite prescribed fires across a landscape that included a long-term research stand. This field note relates comparisons of both fire behavior and fuel consumption metrics for the UAS-ignited burn versus previous burns on the same stand, and versus burns of other research stands in the same year. Results The UAS-ignited prescribed fire experienced burn effects similar to those from ground-ignited prescribed fires on the same stand in previous years, as well as those from ground-ignited prescribed fires on other stands in the same year. Conclusion This post hoc analysis suggests that UAS ignition approaches may be sufficient for achieving prescribed burn goals, thereby enabling practitioners to realize the advantages offered by that ignition mode.

Environmental Sciences & Ecology

Prioritizing Uncertainties in Hydrogen Contribution to Risk in Post-Crash Outcomes for Rail

This report presents analysis from Sandia National Laboratories predicting contributions to risk associated with the use of hydrogen technology for rail. Event sequence diagrams are used to describe possible accident scenarios and progressions. Initiating event frequencies and branch event probabilities for each scenario are quantified with uncertainty using distributions fit to Federal Railroad Administration and U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration data on applicable accidents from 2000 to 2020. Uncertainty is propagated through the event sequence diagram to estimate the frequency and conditional probability of accident end states. The analysis identifies four scenarios with significant contributions to risk from hydrogen that are predicted to occur relatively frequently, which may inform priorities for reducing uncertainty. These scenarios are 1) overpressure events resulting from collisions with hydrogen release due to mechanical damage and delayed ignition, 2) jet fire events resulting from collisions with hydrogen release due to mechanical damage and immediate ignition, 3) jet fires resulting from fire or explosion initiating events involving the hydrogen tank and correct operation of the thermally-activated pressure relief device (TPRD) subsequent to the thermal insult, and 4) pressure burst resulting from fire or explosion initiating events involving the hydrogen tank and failure of the TPRD. Delayed and immediate hydrogen ignition probabilities are identified as being highly uncertain and potential candidates for reducing conservatism in the predicted frequencies for these two scenarios.

08 HYDROGEN

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Enhancing NO Reduction by CO Over NiO/CeO 2 Catalyst by Optimizing the Metal Oxide–Support Interaction

Noble metal catalysts are widely used in three-way catalysts (TWCs) due to their high efficiency, but their scarcity and high cost drive the need for effective, low-cost alternatives. Here, in this work, a series of NiO/CeO 2 catalysts were engineered by modulating the OH content and crystallite size of the CeO 2 support. This approach yielded Ni species ranging from isolated single atoms to small clusters and larger aggregates, with varied NiO/CeO 2 interaction strengths. Evaluation of their performance in NO reduction by CO, CO oxidation, and the water–gas shift reaction revealed that the NiO/CeO 2 -300 catalyst, featuring small CeO 2 crystallites and highly dispersed NiO clusters, delivered superior activity for NO reduction and CO oxidation. It was demonstrated that small NiO clusters, due to their efficient CO adsorption and activation, were more active than Ni single atoms. Furthermore, the presence of water was found to influence the catalyst stability, with NiO clusters less stable than single atoms likely due to the hydroxylation effect leading to the formation of Ni(OH) 2 . Oxygen storage capacity measurements revealed that performance was governed by a combination of CeO 2 crystallite size and the abundance of NiO/CeO 2 interfaces. These findings demonstrated that the catalytic performance of Ni/CeO 2 systems could be maximized by optimizing the Ni nanostructure and its interaction with CeO 2 support, positioning them as a promising, multifunctional nonprecious alternative for three-way catalysis application.

36 MATERIALS SCIENCE

Flame retardant biogenic building insulation materials from hemp fiber

Biogenic thermal insulation materials are in high demand because of its carbon-sequestration nature. However, high flammability, moisture condensation, and relatively high thermal conductivity of biogenic material are major concerns for sustainable building applications. In this study, we report the fire-retardant cellulose xerogel insulation nanocomposites derived from hemp fiber recycling and silica xerogel, in which the boric acid treatment improves its fire retardancy. The as-prepared materials show a low thermal conductivity of 31.3 mW/m K, high flexural modulus of 665 MPa, hydrophobicity with the water contact angle of 115°, and fire retardancy with 30% weight loss over a period of burning time 10 min. Overall, this work provides an effective method for the synthesis of fire-retardant biogenic thermal insulation materials and shows a promising way for next-generation bio-based insulation materials.

36 MATERIALS SCIENCE

Methods and recommendations for large-scale deflagration testing of battery energy storage system enclosures

UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.

Gaudet, Benjamin [UL Solutions] (ORCID:00090006419

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped

Revealing Hidden Quinones Through Diagnostic MS² Fragmentation of Peptide–Quinone Adducts

Quinones are redox-active components of natural organic matter that mediate electron transfer and influence biogeochemical processes, but many quinones in pyrogenic organic matter (PyOM) remain unresolved because they ionize poorly by mass spectrometry. Here, we present a peptide-tagging approach to improve detection of cysteine-reactive electrophiles in PyOM, with quinones expected to be a dominant subset based on reaction chemistry and selectivity experiments. A cysteine-containing peptide was used to form Michael-addition adducts, enhancing electrospray ionization and enabling untargeted screening by high-performance liquid chromatography-high-resolution tandem mass spectrometry. The method was benchmarked with five quinone standards and applied to extracts from charred plant material as a discovery-level screen for cysteine-reactive targets. We identified 98 quinone-candidate adducts (mean neutral mass ~603 Da), of which more than 70% were not detectable in native MS1 data. Among formula-assigned features, hidden quinone candidates had median (O+N)/C of 0.391 and normalized oxidation state of carbon of -0.281, consistent with relatively low polarity and low oxidation state. These results reveal a previously inaccessible pool of hidden redox-active compounds in PyOM and provide a framework for prioritizing quinone-like electrophiles for confirmation and incorporation into models of fire-driven biogeochemical cycling.

LC-MS/MS

Active Fluids Form System-Spanning Filamentary Networks

Recent experimental realizations of liquid-liquid phase separation of active liquid crystals have offered an insight into the interaction between phase separation, ubiquitous in soft matter and biology, and chaotic active flows. Here, in this Letter, we use continuum theory to examine phase separation of an active liquid crystal and a passive fluid and report two new results. First, we provide an analytical derivation of the activity-induced suppression of the phase boundary of the coexistence region—a result first reported in simulations and experiments. We show that the shift in the critical point is a result of the balance between self-stirring active flows and phase-separating diffusive fluxes. Second, we show that this same balance is responsible for dramatically changing the morphology of the phase separated state, resulting in the emergence of a new mixed active phase consisting of a dynamical filamentous active network that invades the entire system area, trapping droplets of passive material. This structure exists even for very low volume fractions of active material. Our work provides an important step towards the goal of understanding how to use activity as a new handle for sculpting interfaces.

active nematics

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE