Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

Developments to the Distributed Holdup Monitoring System in Fiscal Year 2025

Permanently installed holdup monitoring would provide a myriad of benefits to nuclear facilities, ranging among decreased facility burden, increased safety bases, and increased accuracy of relevant material controls and accountancy metrics. However, the cost per detection system must be affordable to provide reliable coverage. For this project, the target unit price per system has been $\$$1,000. Recent work has focused on pushing costs lower through developing a plastic scintillator and silicon photomultiplier (SiPM)–based front end, which are components that are not commercially available in conjunction with each other. Other work has included further system development and use of a low-cost SiPM. Finally, a limited deployment at a processing facility was achieved. Results from this deployment and the development process are discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-cost embedded optical sensing systems for distribution transformer monitoring

There is a mounting need for low-cost monitoring with online sensing technologies to maintain grid reliability and uptime. Here we introduce an innovative low-cost, embedded optical sensing technology initially focused on transformers that was developed and demonstrated at a major electric utility, Con Edison. A version of it that can be retrofitted onto existing transformers in the field was also developed. Two new 500 kVA distribution network transformers were built with embedded fiber-optic (FO) sensors and qualified per industry standards. Vibration, temperature, and corrosion were key parameters monitored. The first transformer with embedded FO sensors was installed at a Con Edison facility and monitored at our team’s office. The second one was installed in an urban street-side underground location with online data processing/feature extraction algorithms and monitored through a wireless router. Additionally, an older transformer was also retrofitted. Data analysis was done on these transformers showing promising correlations with their corresponding loading cycles. Furthermore, key events such as the transformer primary-side energizing, and other events were detected. In general, the technology was demonstrated over 6 months across the 3 transformers instrumented with promising results. Thus, it has the potential to enable predictive maintenance for transformers and other grid assets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Distributed Optical Fiber Sensor Systems for Pipeline Integrity Monitoring

Distributed fiber optic sensors allow the measurement of structural parameters such as static/dynamic strain, temperature, pressure, and vibrations at thousands of locations along a single fiber cable. Deep neural network (DNN) algorithms were developed for rapid data processing speed and vibration event classification.

Lalam, Nageswara↗

All-digital Sensor System for Distributed Downhole Pressure Monitoring in Unconventional Fields

This project developed and validated (through field tests) a new low-cost all-digital pressure sensing technology for in situ distributed downhole pressure monitoring in unconventional oil and gas (UOG) fields. The all-digital sensing technology uses a built-in non-electric analog-to-digital converter (ADC) to transform the pressure information into a combination of binary (ON/OFF) states. As such, the system does not need downhole electronics for signal conditioning and telemetry. The all-digital sensors can be remotely logged over a long distance, and many sensors can be multiplexed for distributed sensing. Based on a review of unconventional wells in the Lower 48 states, the specification of the sensor is to measure pressure up to 69 MPa (10,000 psi) and temperature up to 250°C. A sensor with a helical bourdon sensing element and a digital signal decoder of 50 mm diameter and 109 mm length was constructed. The helical bourdon sensing element was made of 304L stainless steel and filled with motor oil. The digital converter was made up of 8 digital reading pads constructed of high-temperature epoxy with conductive inserts made of stainless steel. The sensor had a linear response to pressure with an accuracy of 0.14 MPa (20 psi). To withstand the high pressure, the sensor was enclosed in a stainless-steel pressure housing with a wall thickness of 5.5 mm, a diameter of 73 mm, and a length of 724 mm. In the laboratory tests, the sensor exhibited no temperature-related effects on the results. The sensor did not show drift over a 14-day test period at elevated pressure. A field test was conducted where the sensor was deployed in a test wellbore at the Quest drilling test facility to a depth of 0 feet over three weeks. The sensor was attached to the production rods, along with a downhole reference sensor of PPS27 type, which is a permanent downhole monitoring system. During the testing phase, the test well annular blow-out preventer was closed, and the well was pressurized at the surface to 11 MPa (1600 psi). The sensor read the elevated bottom hole pressure of 1500 psi. A multiplexing unit was created for the sensor to deploy multiple sensors on one data transmission line in a distributed approach. The multiplexing unit was tested in a simulated environment of 3048 m (10,000 ft) with five sensors distributed. The sensors were pressurized at different intervals. The multiplexed sensors recorded the correct pressure, and the multiplexing did not interfere with the readings. The proposed concept of an all-digital pressure sensor for harsh downhole environments was designed, manufactured, and tested in the laboratory and tested at the field to a up to 69 MPa and 250°C. This technology has high-temperature tolerance and has potential in downhole areas outside oil and gas, such as carbon capture and storage (CCS) and geothermal wells. The sensor concept has been proven in this project, but to create a commercially viable product, manufacturing a sensor with a smaller diameter needs to be performed.

02 PETROLEUM↗

Distributed Optical Fiber Sensor Systems: Application to Natural Gas Pipeline Monitoring

Distributed fiber optic sensing is a cutting-edge technology that has found extensive applications in the monitoring of pipelines. Considering the low backscattering level of standard single-mode fiber as fiber under test, a Rayleigh enhanced optical fiber embedded within the tight-buffered cable is demonstrated in field testing. We analyzed the increased backscattering fiber cable's vibration performance to the conventional single-mode telecom fiber using a custom-built Φ-OTDR interrogator system. Thereafter, using a 4-inch steel pipeline with a flow rate of 5, 10, 15, and 20 ft/s and a fixed pressure level of 1000 psi, we field-tested the sensor system for monitoring natural gas pipeline acoustic vibrations. We also field tested Brillouin optical time domain analysis (BOTDA) system for pipeline hoop strain monitoring under various pressure conditions. The pilot-scale testing results presented in this study suggested that pipeline operators can accurately perform flow monitoring, leak detection, and pressure monitoring for pipeline integrity monitoring.

Lalam, Nageswara↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

An automated system for continuous monitoring of CO 2 geosequestration using multi-well offset VSP with permanent seismic sources and receivers: Stage 3 of the CO2CRC Otway Project

Time-lapse seismic is an essential tool for monitoring CO 2 injection into the subsurface but suffers from high cost and long intervals between surveys. An alternative approach is continuous monitoring using permanent sources and receivers capable of mapping CO 2 plume evolution on an almost daily basis and drastically reduce human effort, cost and survey turnaround. As part of the CO2CRC Otway project, a continuous monitoring system is employed to monitor a small (15,000 tonnes) CO 2 injection within the CO2CRC Otway Project. The permanent monitoring system employs distributed acoustic sensors (DAS) installed in boreholes as seismic receivers and seismic orbital vibrators (SOV) as seismic sources. The monitoring approach is based on vertical seismic profiling using five wells equipped with DAS cemented behind the casing and nine SOVs and is acquiring the data continuously in an autonomous manner. The data is then automatically processed on-site producing a seismic image every 2.5 days, which is then transmitted to a remote office. The data has good repeatability with NRMS of about ~10-15%.

58 GEOSCIENCES↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A data-driven sensor placement approach for detecting voltage violations in distribution systems

Stochastic fluctuations in power injections from distributed energy resources (DERs) combined with load variability can cause constraint violations (e.g., exceeded voltage limits) in electric distribution systems. To monitor grid operations, sensors are placed to measure important quantities such as the voltage magnitudes. Here, in this paper, we consider a sensor placement problem which seeks to identify locations for installing sensors that can capture all possible violations of voltage magnitude limits. We formulate a bilevel optimization problem that minimizes the number of sensors and avoids false sensor alarms in the upper level while ensuring detection of any voltage violations in the lower level. This problem is challenging due to the nonlinearity of the power flow equations and the presence of binary variables. Accordingly, we employ recently developed conservative linear approximations of the power flow equations that overestimate or underestimate the voltage magnitudes. By replacing the nonlinear power flow equations with conservative linear approximations, we can ensure that the resulting sensor locations and thresholds are sufficient to identify any constraint violations. Additionally, we apply various problem reformulations to significantly improve computational tractability while simultaneously ensuring an appropriate placement of sensors. Lastly, we improve the quality of the results via an approximate gradient descent method that adjusts the sensor thresholds. We demonstrate the effectiveness of our proposed method for several test cases, including a system with multiple switching configurations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Area Distribution System State Estimation Using Decentralized Physics-Aware Neural Networks

The development of active distribution grids requires more accurate and lower computational cost state estimation. In this paper, the authors investigate a decentralized learning-based distribution system state estimation (DSSE) approach for large distribution grids. The proposed approach decomposes the feeder-level DSSE into subarea-level estimation problems that can be solved independently. The proposed method is decentralized pruned physics-aware neural network (D-P2N2). The physical grid topology is used to parsimoniously design the connections between different hidden layers of the D-P2N2. Monte Carlo simulations based on one-year of load consumption data collected from smart meters for a three-phase distribution system power flow are developed to generate the measurement and voltage state data. The IEEE 123-node system is selected as the test network to benchmark the proposed algorithm against the classic weighted least squares and state-of-the-art learning-based DSSE approaches. Numerical results show that the D-P2N2 outperforms the state-of-the-art methods in terms of estimation accuracy and computational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Comparative Vacuum Monitoring and Piezoelectric Sensors for Structural Health Monitoring of Rotorcraft Components

The costs associated with the increasing maintenance and surveillance needs of aging structures are rising at an unexpected rate. Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today’s extensive fleet of aging aircraft and space vehicles. Aircraft maintenance and repairs represent about a quarter of a commercial fleet’s operating costs. The application of Structural Health Monitoring (SHM) systems using distributed sensor networks can reduce these costs by facilitating rapid and global assessments of structural integrity. The use of in-situ sensors for real-time health monitoring can overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. The ease of monitoring an entire on-board network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. SHM systems also allow for condition-based maintenance practices to be substituted for the current time-based or cycle-based maintenance approach thus optimizing maintenance labor. The Federal Aviation Administration has conducted a series of SHM validation and certification programs intended to comprehensively support the evolution and adoption of SHM practices into routine aircraft maintenance practices. This report presents one of those programs involving a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Sikorsky, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp., Acellent Technologies Inc., and the Federal Aviation Administration (FAA) carried out a trial validation and certification program to evaluate Comparative Vacuum Monitoring (CVM) and Piezoelectric Transducers (PZT) as a structural health monitoring solution to specific rotorcraft applications. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM and PZT systems into rotorcraft maintenance programs and the document revisions necessary to allow for their routine use as an alternate means of performing periodic structural inspections. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically relevant experimental effort to quantify the reliability of a CVM system applied to Sikorsky S-92 fuselage frame application and a PZT system applied to an S-92 main gearbox mount beam application. The applications included both local and global damage detection assessments. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for SHM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and is acceptable to both the aviation industry and regulatory bodies. The validation work completed in this program demonstrated the ability of both CVM and PZT SHM systems to detect cracks in rotorcraft components. It proved the ability to use final system response parameters to provide a Green Light/Red Light (“GO” – “NO GO”) decision on the presence of damage. In additional to quantifying the performance of each SHM system for the trial applications on the S-92 platform, this study also identified specific methods that can be used to optimize damage detection, guidance on deployment scenarios that can affect performance and considerations that must be made to properly apply CVM and PZT sensors. These results support the main goal of safely integrating SHM sensors into rotorcraft maintenance programs. Additional benefits from deploying rotorcraft Health and Usage Monitoring Systems (HUMS) may be realized when structural assessment data, collected by an SHM system, is also used to detect structural damage to compliment the operational environment monitoring. The use of in-situ sensors for health monitoring of rotorcraft structures can be a viable option for both flaw detection and maintenance planning activities. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM and PZT technology. It will also streamline future regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Optimization of the number and locations of the calibration stations needed to monitor soil moisture using distributed temperature sensing systems: A proof-of-concept study

The single-probe heat-pulse (SPHP) technique combined with the Fiber-optic Distributed Temperature Sensing (DTS) technology can offer novel high-resolution measurements of soil moisture (θ) over spatial scales ranging from several centimeters to several kilometers. However, the key limitation of this method is in obtaining the calibration relationship between θ and soil thermal conductivity (λ) across a specific field. In a previous study, a new methodology using a Gaussian processes model was presented to account for the spatial variability in the λ-θ relationship. The model aggregated θ measurements from soil moisture sensors scattered over the SPHP transect with the corresponding DTS λ measurements at their locations. In this study, a novel methodology is tested to optimize the number and locations of soil moisture sensors required to account for the spatial variability of the λ - θ relationship to achieve higher accuracy from the SPHP technique. The proposed methodology utilizes hierarchical clustering to analyze the information contained in the spatial structure of the SPHP measurements as the soil dries from a nearly-saturated condition. The proposed methodology was tested using data from a field in Oklahoma. Monte-Carlo simulation was performed to validate the performance of the proposed methodology. The predictions obtained from the proposed methodology resulted in θ measurements accuracy comparable to those obtained from the 10% best Monte-Carlo iterations of randomly assigned soil moisture locations. Further, this study demonstrates that the proposed methodology is more efficient than the traditional practice of randomly spreading calibration soil moisture sensors along the SPHP transect.

54 ENVIRONMENTAL SCIENCES↗