Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed services”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers: Preprint

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network--that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest--in the sense of electrical distance--from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for real-time operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anticipating water distribution service outages from increasing temperatures

With projected temperature increases and extreme events due to climate change for many regions of the world, characterizing the impacts of these emerging hazards on water distribution systems is necessary to identify and prioritize adaptation strategies for ensuring reliability. To aid decision-making, new insights are needed into how water distribution system reliability to climate-driven heat will change, and the proactive maintenance strategies available to combat failures. To this end, we present the model Perses, a framework that joins a water distribution network hydraulic solver with reliability models of physical assets or components to estimate temperature increase-driven failures and resulting service outages in the long term. A theoretical case study is developed using Phoenix, Arizona temperature profiles, a city with extreme temperatures and a rapidly expanding infrastructure. By end-of-century under hotter futures there are projected to be 1%–5% more pump failures, 2%–5% more PVC pipe failures, and 3%–7% more iron pipe failures (RCP 4.5–8.5) than a baseline historical temperature profile. Service outages, which constitute inadequate pressure for domestic and commercial use are projected to increase by 16%–26% above the baseline under maximum temperature conditions. The exceedance of baseline failures, when compounded across a large metro region, reveals potential challenges for budgeting, management, and maintenance. An exploration of the mitigation potential of adaptation strategies shows that expedited repair times are capable of offsetting the additional outages from climate change, but will come with a cost.

54 ENVIRONMENTAL SCIENCES↗

Scheduler Modeling of Distributed Energy Resources for Providing Ancillary Services

Distribution energy resources (DERs) have been integral components of modern power systems, and their capability to provide grid services has been widely studied. To promote the deployment of these resources in providing grid services in real-world utility operations, this paper proposes a day-ahead scheduler model for a distribution system connected DER plant. A certain amount of generation capacity of this DER plant is reserved for frequency services, and some ancillary services for the distribution system-including peak load reduction, voltage regulation, and power factor control-are integrated into the model. The model is tested on a real-world distribution system. From the simulation results, the energy and reserve schedule of the solar photovoltaic (PV) unit and battery energy storage system (BESS) can be determined, and voltage and power factor are well maintained. Additionally, in order to demonstrate the specific characteristics of the co-located and hybrid operation modes for the PV and BESS, these two modes are analyzed both theoretically and through real-time simulation. Simulation results show that most of PV's variability is transferred to the net power in the co-located mode, whereas it is transferred to the BESS in the hybrid mode. This proposed scheduler model and the comparison of co-located and hybrid modes can provide practical guidance for the applications of DER plant in the real-world utility.

14 SOLAR ENERGY↗

An Integrated Indexing and Search Service for Distributed File Systems

Data services such as search, discovery, and management in scalable distributed environments have traditionally been decoupled from the underlying file systems, and are often deployed using external databases and indexing services. However, modern data production rates, looming data movement costs, and the lack of metadata, entail revisiting the decoupled file system-data services design philosophy. In this article, we present TagIt, a scalable data management service framework aimed at scientific datasets, which can be integrated into prevalent distributed file system architectures. A key feature of TagIt is a scalable, distributed metadata indexing framework, which facilitates a flexible tagging capability to support data discovery. Furthermore, the tags can also be associated with an active operator, for pre-processing, filtering, or automatic metadata extraction, which we seamlessly offload to file servers in a load-aware fashion. We have integrated TagIt into two popular distributed file systems, i.e., GlusterFS and CephFS. Our evaluation demonstrates that TagIt can expedite data search operation by up to 10× over the extant decoupled approach.

97 MATHEMATICS AND COMPUTING↗

Integrated Transmission and Distribution Co-Simulation Platform for Demonstration of Bulk Grid Services Using Distributed Energy Resources

In September 2020, the Federal Energy Regulatory Commission (FERC) released Order 2222, which opens wholesale markets to small-capacity distributed energy resources (DERs), recognizing their potential in improving operational efficiency by providing bulk grid services. Therefore, a co-simulation capability that can connect transmission and distribution (T&D) simulations and evaluate the impacts of DER provision of bulk grid services is needed. In this paper, we present a new integrated T&D co-simulation platform that incorporates T&D system simulators, DER aggregator/group strategies, and a co-simulation coordinator. Industry-standard communication protocols are employed to mimic real-world conditions. Secondary frequency regulation is selected as the representative bulk grid service, and we simulate the responses of DERs to the frequency regulation signals. The simulation results for a solar-rich distribution feeder in Colorado, USA, demonstrate how the T&D co-simulation setup is used to evaluate the contributions of DERs to minimize the bulk grid frequency deviation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

National Laboratory of the Rockies: Pennsylvania Public Utility Commission/ Technical Utility Services Bureau Distribution System Resilience Deep Dive 2025

The following is a summary of the National Laboratory of the Rockies (NLR) - Pennsylvania PUC/ Technical Utility Services Bureau (TUS) Distribution System Resiliency Deep-Dive project. This is work that NLR performed to provide the support that the TUS requested under the Resources and Support for State Energy Offices & Regulators (RASOR) program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Feedback Optimization of Incentives for Distribution Grid Services

Energy prices and net power injection limitations regulate the operations in distribution grids and typically ensure that operational constraints are met. Nevertheless, unexpected or prolonged abnormal events could undermine the grid's functioning. During contingencies, customers could contribute effectively to sustaining the network by providing services. Herein this paper proposes an incentive mechanism that promotes users' active participation by essentially altering the energy pricing rule. The incentives are modeled via a linear function whose parameters can be computed by the system operator (SO) by solving an optimization problem. Feedback-based optimization algorithms are then proposed to seek optimal incentives by leveraging measurements from the grid, even in the case when the SO does not have a full grid and customer information. Numerical simulations on a standard testbed validate the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Market-based Co-optimization of Energy and Ancillary Services with Distributed Energy Resource Flexibilities

Energy storage systems and flexible loads have attracted significant interests due to their capabilities to provide various grid services. In this paper, the flexibilities are optimally allocated among multiple distributed energy resource aggregators with energy storage systems and flexible buildings by the utility coordinator through market-based co-optimization. An iterative market clearing algorithm is developed to determine the optimal energy and ancillary service prices, with consideration of both local dynamics and network constraints. Simulation results demonstrate the effectiveness of the proposed algorithm and the benefits of co-optimizing the energy and ancillary service markets.

Ma, Ke↗

Steady-State Analysis of Microgrid Distributed Control Under Denial of Service Attacks

Distributed control is an effective method to coordinate multiple components in a microgrid. It usually has mandatory requirements for communication graph topology; changing the topology unexpectedly could disrupt the operation of a distributed controller. A denial of service (DoS) attack blocks communication channels to cause variations in communication graph. Unforeseen topology changes render a controller to receive incomplete system information. Control decisions made based on incorrect information can lead to significantly reduced grid supporting capability. As a result, the vital power balance between generation and load may be challenged. Determining power balance requires steady-state power flow analysis; however, the cyber-induced steady-state analysis is not well studied in the literature. Here, in this article, we show that a cyber–physical microgrid with unknown DoS attacks has augmented uncertain power flow equations, whose special structure creates new computational issue to determining power balance. To deal with the issue, we develop a novel cyber-induced microgrid model: the cyber–physical system is transformed into a pure physical model, where the disruption effects of DoS in the cyber layer are shown to be equivalent to the variations of the physical model parameters. With the transformed system, we develop a sufficient condition to ascertain the system power balance under unknown DoS attacks. In addition, practical insights for resilient distributed control design are shown as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Market Design for Peer-to-Peer Energy Trade and Ancillary Services in Distribution Grids

A novel peer-to-peer (P2P) market design is proposed in this work for the distribution grid level. Envisioning that the grid constraints violations are the major challenge for P2P energy sharing, we propose they are handled through the ancillary service (AS) market. By calculating the decomposable distribution locational marginal prices (DLMPs), the essential price signals of procuring AS can be recovered to determine the grid usage prices (GUPs) to each P2P transaction. Hence, the GUPs, due to their decomposable properties, act as incentive signals for the P2P market to support the grid operation in terms of loss reduction, voltage support and congestion management. The proposed market design comprises: i) an interactive market design of P2P trade & AS and, ii) a fully decentralized peer-centric market clearing model for P2P energy trade. The duality analysis provides the composition of market equilibrium prices of P2P trading and their interpretations. The case studies demonstrate the effectiveness of the proposed P2P trade to support grid operational objectives.

Zhang, Kai↗

Sensors with Intelligent Measurement Platform for Monitoring and Control in Distribution Circuits

This paper presents a medium-voltage intelligent measurement platform that provides post-processing of raw measurements received from commercially-available voltage/current sensors to enhance accuracy and bandwidth of the monitoring system. Furthermore, this platform integrates into a Data Distribution Service (DDS) messaging bus for distributed control and interoperability. The authors present the design, specifications, and major components included in the platform, and argue for applications and use cases that most benefit from this new approach. A laboratory testbed has been created to demonstrate the functionality, for which test results are presented for selected test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep reinforcement learning assisted co-optimization of Volt-VAR grid service in distribution networks

With the increasing penetration of distributed energy resources in distribution networks, Volt-VAR control and optimization (VVC/VVO) have become very important to ensure an acceptable quality of service to all customers. System operators can rely on slow-responding utility devices, including capacitor banks and on-load tap changing transformers, along with fast-responding battery and photovoltaic (PV) inverters for the VVC/VVO implementation. Because of variations in response time of these two classes of devices, and different control actions (discrete versus continuous), coordinated and optimal scheduling and operation have become of utmost importance. Here, this paper develops a look-ahead deep reinforcement learning (DRL)-based multi-objective VVO technique to improve the voltage profile of active distribution networks, decrease network and inverter power loss, and save the operational cost of the grid. It proposes a deep deterministic policy gradient (DDPG)-based approach to schedule the optimal reactive and/or active power set-points of fast-responding inverters, and a deep Q-network (DQN)-based DRL agent to schedule the discrete decisions variables of slow-responding assets. The reactive power output of PV and battery smart inverters are scheduled at 30-minute intervals and the capacitors’ commitment status is scheduled with several hour intervals. The proposed framework is validated on the modified IEEE 34-bus and 123-bus test cases with embedded PV and PV-plus-storage. To validate the efficacy of the proposed VVO, it is compared with several scenarios, including the base case without VVO, localized droop control of DERs, DDPG-only, and twin delayed DDPG (TD3) agent-based DRL techniques. The results justify the superior performance of the proposed method to improve the voltage profile, reduce network power loss, and minimize the look-ahead grid operational cost while minimizing the undesirable power losses in inverters as a result of power factor adjustments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NERSC_Lightweight Distributed Metric Service (NERSC_LDMS) v4.4.2

Miscellany This LDMS Loftsman/Helm Chart horizontally scales LDMS daemons in order to achieve a 1Hz sample rate from over 5,000 nodes, collecting 38k metrics per minute on Perlmutter. This LMDS Configuration relies on already running `ldmsd` producers running on nodes, which produce metrics via sampler plugins. The Helm chart distributes the collection of metrics from producer acrross many aggregator and storage `ldmsd` daemons, ensuring no damon is overloaded and data loss is avoided.

Stile, John [Lawrence Berkeley National Laboratory↗

LDMS-GPU: Lightweight Distributed Metric Service (LDMS) for NVIDIA GPGPUs

GPUs are now a fundamental accelerator for many high-performance computing applications. They are viewed by many as a technology facilitator for the surge in fields like machine learning and Convolutional Neural Networks. To deliver the best performance on a GPU, we need to create monitoring tools to ensure that we optimize the code to get the most performance and efficiency out of a GPU. Since NVIDIA GPUs are currently the most commonly implemented in HPC applications and systems, NVIDIA tools are the solution for performance monitoring. The Light-Weight Distributed Metric System (LDMS) at Sandia is an infrastructure widely adopted for large-scale systems and application monitoring. Sandia has developed CPU application monitoring capability within LDMS. Therefore, we chose to develop a GPU monitoring capability within the same framework. In this report, we discuss the current limitations in the NVIDIA monitoring tools, how we overcame such limitations, and present an overview of the tool we built to monitor GPU performance in LDMS and its capabilities. Also, we discuss our current validation results. Most of the performance counter results are the same in both vendor tools and our tool when using LDMS to collect these results. Furthermore, our tool provides these statistics during the entire runtime of the tool as a time series and not just aggregate statistics at the end of the application run. This allows the user to see the progress of the behavior of the applications during their lifetime.

97 MATHEMATICS AND COMPUTING↗