Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed power generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High performance protonic ceramic fuel cell systems for distributed power generation

The technology landscape around distributed generation continues to evolve in response to increasing demand for high-efficiency, low-emission, low-cost power generation. While emerging distributed power technologies, such as solid oxide fuel cells (SOFCs), continue to advance, they still face challenges due to their high capital costs, and shorter lifetimes that typically arise from electrochemical stack performance degradation at high operating temperatures (>750 °C). Recent advancements in protonic ceramic fuel cells (PCFCs) offer the potential to mitigate drawbacks of their higher temperature SOFC counterparts by enabling lower operating temperatures (550 °C–600 °C) with acceptable power densities. Here the present work leverages the recent progress in protonic ceramic cell and stack technology development to generate viable system configurations and evaluate the energetic performance potential of PCFC-based systems for stationary power generation. Process system engineering of two water-neutral system concepts, which provide 25 kW of electric power and process hot water, are presented and evaluated through sensitivity studies. Stack design parameters are altered and used to gauge the effect on system performance characteristics, including fuel cell stack and balance-of-plant sizing requirements, and electric and cogeneration efficiencies. The study finds that the potentially high per-pass fuel utilization capability of PCFC stacks could enable unprecedented electric efficiencies approaching 70% without hybridization with other prime movers.

25 ENERGY STORAGE↗

Distributed power generation via gasification of biomass and municipal solid waste: A review

The access to electricity has increased worldwide, growing from 60 million additional consumers per year in 2000-2012 to 100 million per year in 2012-2016. Despite this growth, approximately 675 million people will still lack access to electricity in 2030, indicating that electricity demand will continue to increase. Unfortunately, traditional large fossil power technologies based on coal, oil and natural gas lead to a major concern in tackling worldwide carbon dioxide emissions, and nuclear power remains unpopular due to public safety concerns. Distributed power generation utilizing CO 2 -neutral sources, such as gasification of biomass and municipal solid wastes (MSW), can play an important role in meeting the world energy demand in a sustainable way. Furthermore, this review focuses on the recent technology developments on seven power generation technologies (i.e. internal combustion engine, gas turbine, micro gas turbine, steam turbine, Stirling engine, organic rankine cycle generator, and fuel cell) suitable for distributed power applications with capability of independent operation using syngas derived from gasification of biomass and MSW. Technology selection guidelines is discussed based on criteria, including hardware modification required, size inflexibility, sensitivity to syngas contaminants, operational uncertainty, efficiency, lifetime, fast ramp up/down capability, controls and capital cost. Major challenges facing further development and commercialization of these power generation technologies are discussed.

09 BIOMASS FUELS↗

Red-Ox Robust SOFC Stacks for Affordable, Reliable Distributed Generation Power Systems

While SOFC systems are expected to operate reliably and with limited degradation in steady state or transient performance, SOFC stacks may ultimately fail due to the loss of structural integrity of one or several of the cells as a result of the weakening of the materials and interfaces due to physico-chemical changes that occur during continuous operation as a result of plastic and creep deformations, modification of the temperature profile, and/or degradation of the electrochemical performance of the cells. Degradation mechanisms originating from the cell components include coarsening of the microstructure over time; decomposition of materials; chemical reaction of electrode materials with electrolyte at the interface; delamination from each other; and for the anode, coking and sulfur poisoning. Of all the reliability issues that may occur for SOFCs, the main limitation for Ni-based cermet anodes (e.g., NiO-YSZ) is the poor stability during reduction-oxidation (red-ox) cycling. This project was aimed at the development of ceramic anode SOFCs based on SFCM (SrFe0.2Co0.4Mo0.4O3), which is a conductive perovskite that is red-ox stable. Additionally, the project involved the development of a red-ox robust stack. Scale up of SFCM-based cells to a large format (10 cm by 10 cm) cell size was achieved as well as a maximum power density of 0.9 W/cm 2 at 600 °C (>0.6 W/cm 2 at 0.6 V). Up to a 10-cell stack was successfully assembled and demonstrated, and cells showed similar performance in reformed, pipeline natural gas as in hydrogen. Finally, a 3-cell stack was red-ox cycled without degradation for 40 cycles at ~600 °C.

03 NATURAL GAS↗

Distributed Minimization of the Power Generation Cost in Prosumer-Based Distribution Networks: Preprint

Traditionally, electrical power was generated in big power plants. The cost of producing energy was related to the cost of fuel, e.g., carbon or gas, and by the cost of maintaining the power plants. With the advent of distributed energy resources, power can be produced directly at the edge of the electrical network by a new type of agents: the prosumers. Prosumers are entities that both consume and generate power, e.g., by means of photovoltaic panels. The cost of the power produced by prosumers is no longer related to fuel consumption since energy coming from distributed generators is essentially free. Rather, the cost is related to the remuneration that is due to the prosumers for the services they provide. The proposed control strategy minimizes the active power generation cost in the aforementioned scenario. The control scheme requires that the prosumers measure their voltage and then adjust the amount of injected power, according to a continuous time feedback control law that is indeed a projected gradient descent strategy. Simulations are provided in order to illustrate the algorithm behavior.

distributed control↗

Technology survey of electrical power generation and distribution for MIUS application

Candidate electrical generation power systems for the modular integrated utility systems (MIUS) program are described. Literature surveys were conducted to cover both conventional and exotic generators. Heat-recovery equipment associated with conventional power systems and supporting equipment are also discussed. Typical ranges of operating conditions and generating efficiencies are described. Power distribution is discussed briefly. Those systems that appear to be applicable to MIUS have been indicated, and the criteria for equipment selection are discussed.

Gill, W. L.↗

Single phase inverter for a three phase power generation and distribution system

A breadboard design of a single-phase inverter with sinusoidal output voltage for a three-phase power generation and distribution system was developed. The three-phase system consists of three single-phase inverters, whose output voltages are connected in a delta configuration. Upon failure of one inverter the two remaining inverters will continue to deliver three-phase power. Parallel redundancy as offered by two three-phase inverters is substituted by one three-phase inverter assembly with high savings in volume, weight, components count and complexity, and a considerable increase in reliability. The following requirements must be met: (1) Each single-phase, current-fed inverter must be capable of being synchronized to a three-phase reference system such that its output voltage remains phaselocked to its respective reference voltage. (2) Each single-phase, current-fed inverter must be capable of accepting leading and lagging power factors over a range from -0.7 through 1 to +0.7.

Lindena, S. J.↗

Resilient distribution system leveraging distributed generation and microgrids: a review

With the aging of electricity transmission and distribution infrastructures and increasing intensity of extreme weather events, the aggravated vulnerability of electric distribution systems to extreme weather events has motivated the study of resilient distribution systems. This study presents a review of the state-of-the-art research on distribution grid resilience. First, the definition and quantifying metrics of resilience in the electrical distribution system are summarised. Second, the long-term and short-term measures to enhance the distribution system resilience are discussed. In particular, the recent studies on distributed generation and microgrid-assisted resilience enhancements are reviewed. Finally, recommendations for future research are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Modular Sub-Atmospheric Hybrid Heat Engine (Final Report)

The Phase 1 Final Technical Report describes the results of the work completed during the “Advanced Modular Sub-Atmospheric Hybrid Heat Engine” project. A key part of the Phase 1 work was the completion of a thermodynamic cycle analysis for the MHHE at the selected module size. The hybrid heat engine has been developed as a modular unit (sized in the range of 500kW – 60MW) that can be used with modular coal or biomass gasifiers, with distributed power generation systems, with large power plants comprised of multiple generating units, and with natural gas compression stations. The MHHE will provide cleaner, more efficient, and lower cost generation with better load following capabilities than existing competing technologies with a singular generating source such as solar farm, gas turbine, or combustion engine. The drivers of the MHHE technology are: benefits of modular power generation (reduced equipment cost, construction cost and implementation time, connection ready on delivery, flexible scalability, serviceability), fuel flexibility, lowest cost power generation and reduced emissions.A logical progression of work and a clear path forward toward meeting the FOA goals and objectives have been established. Namely, a preliminary market analysis and primary fuel identification was completed first and then the modularity of the system was defined. The benefits of the proposed hybrid and modular heat engine were described when applied to modular coal gasifiers, distributed power generators, and larger power plants. Based on the market analysis, modularity, and chosen primary fuel, a conceptual design and layout of the hybrid heat engine was developed, analyzed, and characterized. The technology gaps already identified have been reviewed and expanded upon, and a test plan to address these gaps through bench scale testing in Phase 2 has been developed. Cost estimate methodology and considerations in support of a potential Phase 2 project have been described.

08 HYDROGEN↗

Critical values of cyber parameters in a dynamic microgrid system

An islanded microgrid can be used to serve critcal load as a resiliency source when a severe outage occurs. In an islanded mode, control of a microgrid relies on the communication system significantly. Hence, microgrids are cyberphysical systems and, therefore, the cyber system plays a crucial role in the performance of the cyber-power system. A microgrid control scheme is proposed for power dispatch and regulation based on the droop and proportional-integral (PI) feedback control. The proposed control strategy is validated for transient stability following dynamic events. To evaluate the impact of a networked control system on control performance, a cyber model is developed to represent data acquisition periods and communication delays. An analytical method is proposed to determine the critical values for the data reporting periods and communication delays. The analytical method based on a state space model of a networked control system is applicable for large-scale systems. A 2-dimensional stability region of a microgrid in the space of cyber parameters can be obtained by the proposed method, and the critical values of cyber parameters are determined based on the stability region. Simulation results validate that the design of a microgrid as a cyber-physical system needs to be guided by critical values for the data reporting period and communication delay to prevent system instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar power generation and distribution

The production of electricity from solar energy is discussed. The economics of the proposed generation and distribution systems are analyzed. The use of photovoltaics for converting solar energy to home heating is proposed. The problems of energy distribution are analyzed from the standpoint of equipment costs and complexity.

Source record↗

Final Report for ARPA-E NODES "Real-Time Optimization and Control of Next-Generation Distribution Infrastructure" Project

The project examined next-generation power distribution systems with high levels of power- electronics-interfaced distributed energy resources (DERs) that include: renewable energy systems (RESs), energy-storage devices, electric vehicles, fuel cells, small-scale diesel generators, and controllable loads. The project developed a comprehensive distribution- network management framework that unifies real-time voltage and frequency control with network-wide energy management under an integrated framework. The aim of the project was to: i) systematically optimize network-wide operation and congruently regulate voltages and frequency in the face of high volatility induced by rapidly varying RES and uncontrolled loads; ii) facilitate high renewable integration beyond 50% on an energy basis; iii) meet power-quality requirements and operational constraints; and, iv) respect response, ramp- time, and hold-time requirements for synthetic frequency and regulating reserves via fast- and longer-term dynamic energy management.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control/electrical power generation subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Electrical Power Distribution and Control (EPD and C)/Electrical Power Generation (EPG) hardware. The EPD and C/EPG hardware is required for performing critical functions of cryogenic reactant storage, electrical power generation and product water distribution in the Orbiter. Specifically, the EPD and C/EPG hardware consists of the following components: Power Section Assembly (PSA); Reactant Control Subsystem (RCS); Thermal Control Subsystem (TCS); Water Removal Subsystem (WRS); and Power Reactant Storage and Distribution System (PRSDS). The IOA analysis process utilized available EPD and C/EPG hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

Patton, Jeff A.↗

Influence of Inverter-Based Resources on Microgrid Protection: Part 1: Microgrids in Radial Distribution Systems

Microgrids are being deployed at a rising rate, primarily as a means of increasing power system resilience. Commonly, a microgrid today includes at least some inverter-based resources (IBRs), and many microgrids have modes or conditions under which they are entirely energized by IBRs. Also, most microgrids today are deployed on radial distribution circuits, but it is conceivable that they could also be considered for deployment on secondary network systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Networked Microgrids for Grid Resilience, Robustness, and Efficiency: A Review

Networked microgrids (NMGs) are clusters of microgrids that are physically connected and functionally interoperable. The massive and unprecedented deployment of smart grid technologies, new business models, and involvement of new stakeholders enable NMGs to be a conceptual operation paradigm for future distribution systems. Much work needs to be done, however, to enable NMGs to achieve seamless coordination, including physical, communication, and functional integration. In this paper, we review and summarize the state-of-the-art methodologies for operation and control of NMGs. Furthermore, we also specifically discuss the notion of dynamic boundaries for advanced microgrid applications. In addition, we introduce the opportunities, challenges, and possible solutions regarding NMGs for improving grid resilience, robustness, and efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗