Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed generator (DG)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Distributed Generation (DG) for Resilience Planning Guide

This planning guide provides information and resources on how distributed generation, with a focus on combined heat and power, can help communities meet resilience goals and ensure critical infrastructure remains operational regardless of external events.

distributed generation, combined heat and power, C↗

(DG)2 (Distributed Generation for Distribution Grids) [SWR-18-63]

(DG)2 is an impact analysis tool for electrical utilities to perform spatio-temporal analysis with solar and battery energy storage systems. The purpose of the tool is to help distribution utilities with identifying impacts and costs associated with locating a MW-scale solar farm and energy storage system at a certain location over other choices. This tool also assists utilities to assess the amount of reverse power flow at the transmission lines.

Latif, Aadil↗

Preliminary Feasibility Assessment of Integrating CCHP with NW Food Processing Plant #1: Modeling Documentation

The Pacific Northwest National Laboratory (PNNL) has launched a project funded by the Bonneville Power Association (BPA) to identify strategies for increasing industrial energy efficiency and reducing energy costs of Northwest Food Processors Association (NWFPA) plants through deployment of novel combinations and designs of variable-output combined heat and power (CHP) distributed generation (DG), combined cooling, heating and electric power (CCHP) DG and energy storage systems. Detailed evaluations and recommendations of CHP and CCHP DG systems will be performed for several Northwest (NW) food processing sites. The objective is to reduce the overall energy use intensity of NW food processors by 25% by 2020 and by 50% by 2030, as well as reducing emissions and understanding potential congestion reduction impacts on the transmission system in the Pacific Northwest.

Bonneville Power Association↗

Assessment of the Distributed Generation Market Potential for Solid Oxide Fuel Cells

The focus of the solid oxide fuel cell (SOFC) program at the National Energy Technology Laboratory (NETL) is to develop low-cost, highly efficient solid oxide fuel cell power systems that are capable of simultaneously producing electric power with carbon capture when integrated with gasification. To accomplish this goal, research and demonstration projects are being undertaken to enhance the reliability and the robustness of the SOFC system. NETL’s SOFC technology roadmap is focused on developing and demonstrating progressively larger megawatt electric (MWe) class natural-gas-based systems to validate and advance SOFC technology for natural gas and gasified coal-based utility scale power generation. As the SOFC technology advances from its current state to utility scale, it is possible that MWe class systems could penetrate the distributed generation (DG) market segment. If the SOFC technology were to penetrate the DG market, this would have the added benefit of lowering system costs by establishing operational experience and a manufacturing base. This report analyzed the strengths of the SOFC system in conjunction with relevant DG market segments in the United States (U.S.) and determined that natural gas compressor stations, grid strengthening, and data centers were potential early market-entry opportunities. These three DG market segments are projected to demand two gigawatts (GWs) of additional power between now and 2018 and 25 GWs between now and 2040. Historical experiences with related technology, including effects of increased production capacity on capital costs, were used to evaluate the market penetration necessary for a cost competitive DG SOFC system. This analysis showed that the DG SOFC system becomes cost competitive with other fossil-fuel based DG technologies after 25 MWe of installed capacity, around 2025, based on the demonstration of the first SOFC DG unit in the year 2020. The SOFC DG application validates and enables the technology for utility scale systems with carbon capture and forms an essential first phase of the NETL technology development roadmap, which is based on the vision to develop a commercially competitive utility-scale system with carbon capture.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal investment strategies for distributed generation in distribution networks with real option analysis

Efficient and well‐timed investment in distributed generation (DG) in distribution networks in the electricity market environment presents a big challenge for distribution companies. In this study, a real option valuation framework is proposed to determine the optimal investment strategies for DG including the investment location, size, and timing. Within the proposed framework, the profit from investing in DG is modelled, where the benefits include the operation cost savings and capacity update deferral benefit compared with a no‐DG‐investment scenario over the study period. Future power demands and electricity prices are modelled as stochastic variables. The candidate DG investment plans are considered as multiple mutually exclusive options, and the corresponding managerial flexibility for seizing opportunities and mitigating risk of loss upon an unfavourable unfolding of future uncertainties is assessed with real option analysis using the extended least square Monte Carlo method. The distribution of future investment strategies and optimal initial investment threshold levels under various scenarios are analysed in a case study to demonstrate the characteristics of the proposed framework and methodology.

Zou, Bo↗

Forming Interphase Microgrids in Distribution Systems Using Cooperative Inverters

Interphase-microgrids formed by three islanded single-phase feeders in distribution systems are proposed in this paper. Loss of utility caused by natural and human-made disasters may isolate each residential subdivision from the utility. In this case, the household loads are supplied by distributed generation (DG) units which may not be enough to meet the load demand. This can lead to deviations in voltage and frequency, and the deviations may vary for each phase. The proposed solution is to form an interphase-microgrid by seamlessly interconnecting the islanded single-phase feeders. This interphase-microgrid can effectively balance the load demands and DG generation in distribution systems after losing the utility supply. This paper presents different case studies to demonstrate the viability of forming interphase-microgrids for residential distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategic Placement and Sizing of Distributed Generation for Resilience Enhancement of Distribution Grids With Microgrid Formation

The rise in frequency and severity of extreme weather events highlights the need for resilient power distribution networks. Microgrids can help improve the resilience of distribution grids by providing continuous power supply using local distribution generation (DG) when the distribution grid fails. In this paper, we propose an approach for optimal placement and sizing of DG to form multiple microgrids throughout the distribution network by restoration actions such as switching operations in case of distribution grid outages caused by extreme weather events. Considering the randomness of damaged distribution lines, the DG placement and sizing problem is formulated as a two-stage stochastic mixed-integer program, with the first stage determining the placement and size of DG, and the second stage focusing on minimizing the amount of load shedding through network restoration and microgrid formations for each scenario. Due to the large number of scenarios, the sample average approximation (SAA) method is employed to solve the problem. The results of case studies on a modified IEEE 33 bus distribution grid demonstrate the effectiveness of the proposed DG placement and sizing strategy in improving the resilience of distribution grids by allowing the formation of multiple microgrids. In addition, the robustness and accuracy of the SAA method are validated through various case studies.

Distributed generation planning↗

Advanced Energy Storage Management in Distribution Network

With increasing penetration of distributed generation (DG) in the distribution networks (DN), the secure and optimal operation of DN has become an important concern. In this paper, an iterative mixed integer quadratic constrained quadratic programming model to optimize the operation of a three phase unbalanced distribution system with high penetration of Photovoltaic (PV) panels, DG and energy storage (ES) is developed. The proposed model minimizes not only the operating cost, including fuel cost and purchasing cost, but also voltage deviations and power loss. The optimization model is based on the linearized sensitivity coefficients between state variables (e.g., node voltages) and control variables (e.g., real and reactive power injections of DG and ES). To avoid slow convergence when close to the optimum, a golden search method is introduced to control the step size and accelerate the convergence. The proposed algorithm is demonstrated on modified IEEE 13 nodes test feeders with multiple PV panels, DG and ES. Numerical simulation results validate the proposed algorithm. Various scenarios of system configuration are studied and some critical findings are concluded.

linearization↗

Design and Analysis of a Region-Wide Remotely Controllable Electrical Lock-Out System

Electric utilities have a main responsibility to protect the lives and safety of their workers when they are working on low-, medium-, and high-voltage power lines and distribution circuits. With the anticipated widespread deployment of smart grids, a secure and highly reliable means of maintaining isolation of customer-owned distributed generation (DG) from the affected distribution circuits during maintenance is necessary to provide a fully de-energized work area, ensure utility personnel safety, and prevent hazards that can lead to accidents such as accidental electrocution from unanticipated power sources. Some circuits are serviced while energized (live line work) while others are de-energized for maintenance. For servicing de-energized circuits and equipment, lock-out tag-out (LOTO) programs provide a verifiable procedure for ensuring that circuit breakers are locked in the off state and tagged to indicate that status to operational personnel so that the lines will be checked for voltage to verify they are de-energized. The de-energized area is isolated from any energized sources, which traditionally are the substations. This procedure works well when all power sources and their interconnections are known armed with this knowledge, utility personnel can determine the appropriate circuits to de-energize for isolating the target line or equipment. However, with customer-owned DG tied into the grid, the risk of inadvertently reenergizing a circuit increases because circuit connections may not be adequately documented and are not under the direct control of the local utility. Thus, the active device may not be properly de-energized or isolated from the work area. Further, a remote means of de-energizing and locking out energized devices provides an opportunity for greatly reduced safety risk to utility personnel compared to manual operations. In this paper, we present a remotely controllable LOTO system that allows individual workers to determine the configuration and status of electrical system circuits and permit them to lock out customer-owned DG devices for safety purposes using a highly secure and ultra-reliable radio signal. The system consists of: (1) individual personal lockout devices, (2) lockout communications and logic module at circuit breakers, which are located at all DG devices, and (3) a database and configuration control process located at the utility operations center. The lockout system is a close permissive, i.e., loss of control power or communications will cause the circuit breaker to open. Once the DG device is tripped open, a visual means will provide confirmation of a loss of voltage and current that verifies the disconnected status of the DG. Further the utility personnel will be able to place their own lock electronically on the system to ensure a lockout functionally. The proposed LOTO system provides enhanced worker safety and protection against unintended energized lines when DG is present. The main approaches and challenges encountered through designing the proposed region-wide LOTO system are discussed in this paper. These approaches include: (1) evaluating the reliability of the proposed approach under N-modular redundancy with voter/spares configurations and (2) conducting a system level risk assessment study using the failure modes and effects analysis (FMEA) technique to identify and rank failure modes by probability of occurrence, probability of detection, and severity of consequences. This ranking allows a cost benefits analysis to be conducted such that dollars and efforts will be applied to the failures that provide greatest incremental gains in system capability (resilience, survivability, security, reliability, availability, etc.) per dollar spent whether capital, operations, or investment. Several simulation scenarios and their results are presented to demonstrate the viability of these approaches.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Resilience-Oriented DG Siting and Sizing Considering Stochastic Scenario Reduction

In this paper, a fuel-based distributed generator (DG) allocation strategy is proposed to enhance the distribution system resilience against extreme weather. The long-term planning problem is formulated as a two-stage stochastic mixed-integer programming (SMIP). The first stage is to make decisions of DG siting and sizing under the given budget constraint. In the second stage, a post-extreme-event-restoration (PEER) is employed to minimize the operating cost in an uncertain fault scenario. In particular, this study proposes a method to select the most representative scenarios for the SMIP. First, a Monte Carlo Simulation (MCS) is introduced to generate sufficient scenarios considering random fault locations and load profiles. Then, the number of scenarios is reduced by the K-means clustering algorithm. The advantage of scenario reduction is to make a trade-off between accuracy and computational efficiency. Finally, the SMIP is solved by the progressive hedging algorithm. Here, the case studies of the IEEE 33-bus and 123-bus test systems demonstrate the effectiveness of the proposed algorithm in reducing the expected energy not served (EENS), which is a critical criterion of resilience.

42 ENGINEERING↗

Distributed Online Voltage Control in Distribution Network: A Two-Stage Real-Time Implementation

The increasing integration of renewable-based distributed generation (DG) brings growing challenges to distribution network (DN) voltage control. To address this issue, a two-stage distributed online voltage control framework (TDO-VC) is proposed in this paper. In the proposed method, legacy voltage control devices are controlled in the upper stage on an hourly timescale, while DGs operate autonomously online in the lower stage to remove instantaneous voltage violations. The idea of receding horizon control is applied in the upper stage to comprehensively consider the current and future renewable generation, and the generalized fast dual ascent (Gf-DA) is employed in the lower stage to effectively manage DGs through near real-time optimization. The effectiveness of the proposed TDO-VC is demonstrated by rigorous theoretical analysis and case studies on IEEE-123 bus system.

Distributed generation↗

Updating Technical Screens for PV Interconnection: Preprint

Solar photovoltaics (PV) is the dominant type of distributed generation (DG) technology interconnected to electric distribution systems in the United States, and deployment of PV systems continues to increase rapidly. Considering the rapid growth and widespread deployment of PV systems in United States electric distribution grids, it is important that interconnection procedures be as streamlinedas possible to avoid unnecessary interconnection studies, costs, and delays. Because many PV interconnection applications involve high penetration scenarios, the process needs to allow for a sufficiently rigorous technical evaluation to identify and address possible system impacts. Existing interconnection procedures are designed to balance the need for efficiency and technical rigor for all DG.However, there is an implicit expectation that those procedures will be updated over time in order to remain relevant with respect to evolving standards, technology, and practical experience. Modifications to interconnection screens and procedures must focus on maintaining or improving safety and reliability, as well as accurately allocating costs and improving expediency of the interconnectionprocess. This paper evaluates the origins and usefulness of the capacity penetration screen, offers potential short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen.

14 SOLAR ENERGY↗

Formulating a simplified equivalent representation of distribution circuits for PV impact studies.

With an increasing number of Distributed Generation (DG) being connected on the distribution system, a method for simplifying the complexity of the distribution system to an equivalent representation of the feeder is advantageous for streamlining the interconnection study process. The general characteristics of the system can be retained while reducing the modeling effort required. This report presents a method of simplifying feeders to only specified buses-of-interest. These buses-of-interest can be potential PV interconnection locations or buses where engineers want to verify a certain power quality. The equations and methodology are presented with mathematical proofs of the equivalence of the circuit reduction method. An example 15-bus feeder is shown with the parameters and intermediate example reduction steps to simplify the circuit to 4 buses. The reduced feeder is simulated using PowerWorld Simulator to validate that those buses operate with the same characteristics as the original circuit. Validation of the method is also performed for snapshot and time-series simulations with variable load and solar energy output data to validate the equivalent performance of the reduced circuit with the interconnection of PV.

Reno, Matthew J.↗

Cost Recovery for Standby and Ancillary Services for Distributed Generation: Considerations for New Mexico

A New Mexico statute allows investor-owned utilities to recover costs of “standby and ancillary services” resulting from distributed generation (DG). In attempting to do so, it is important to recognize both the physical and economic impacts, positive and negative, that distributed generation creates. Distributed generation has different impacts on ancillary and standby services depending on the location, capacity, and production patterns of the systems. Low penetrations of small distributed generation systems will not create significant contingencies for utilities. System impact of fluctuations in DG production may be no larger than normal fluctuations caused by customer demand, such as an air conditioner cycling. Higher penetrations and large DG system may produce noticeable impacts; so magnitude is critical when determining potential additional recoverable utility costs. Understanding DG impact on ancillary services is a relatively new and emerging area of study and as such there are not well-established formulas or protocols. Discretion is required. A hosting capacity analysis can help determine how much DG can be implemented before the impacts become substantive. Standby rates are traditionally used for large industrial generators or combined heat and power systems and threshold system size levels are often used in determining applicability of standby rates. System size thresholds may also be appropriate for standby rates and DG. Relatively small, geographically diverse DG systems are unlikely to create a noticeable coincident outage, so developing a standby charge based on assumed coincidence may not be appropriate. Individual lines and feeders may have considerable excess capacity during coincident outages, or they may be fully utilized and facing upgrades in the near future, which could vary over time. Understanding specific events that create concern for utilities is critical to developing an appropriate rate mechanism (e.g., single residential or community system outage, cascading event, clouds, eclipse). Any modeling or studies of the grid should also recognize the unique situation created when DG is coupled with a smart inverter or storage. These devices change the value proposition and can help mitigate some of the voltage and ramping issues DG can pose for a utility. Utilities can recover their fixed costs in a variety of ways, and some are better suited for DG than others. Beyond charging for standby and ancillary services, other options include fixed customer charges, demand charges, minimum bills, time-of-use rates and updated net energy-metering policies. Studies and analyses of the specific impacts that DG has on the grid should inform utilities’ decision-making process because distributed generation creates both costs and benefits for the grid. Any charge specific to DG customers should be backed up with analysis. At the heart of this conversation is utilities attempting to recover fixed costs. Allowing utilities to indiscriminately recover all stranded fixed costs can negatively affect long-term market efficiency by blunting utility incentives to lower costs and acting as a barrier to entry and exit. The current status of New Mexico’s grid, impending infrastructure updates, and likely customer adoption patterns for DG (backed up by transparent analysis) should remain at the forefront when considering charges for standby and ancillary services. Recognizing that utility regulation is largely a reactive process, it is recommended that applications for DG related standby or ancillary services cost recovery mechanisms be thoroughly reviewed by an experienced economist. If the commission has no such skill set on staff, one might be hired.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Compensation for Distributed Solar. A Survey of Options to Preserve Stakeholder Value

Compensation mechanisms for electricity generation systems installed behind the meter are under scrutiny in several jurisdictions in the United States. Legislators in 29 states introduced bills to amend net metering provisions in 2014, and in 33 states in the 2015 legislative session as of August 20, 2015. Some utilities have also sought to increase the revenue they receive from net-metered customers through rate redesign. The circumstances that have triggered the recent push for change include a growing percentage of net-metered customers, potential effects of distributed generation on cost allocation, decreasing photovoltaic (PV) system costs, the challenges of integrating high levels of solar generation in the distribution network, and increasing pressure on utility business models. This report presents a survey of options to charge and compensate PV customers, as well as options that may preserve utility revenues in scenarios with increased DG. These options could be used as building blocks to create a distributed generation (DG) compensation policy that may preserve the value of the different stakeholders and balance their interests.

14 SOLAR ENERGY↗

ANALYSIS OF DISTRIBUTION FEEDER LOSSES DUE TO ADDITION OF DISTRIBUTED PHOTOVOLTAIC GENERATORS

Distributed generators (DG) are small scale power supplying sources owned by customers or utilities and scattered throughout the power system distribution network. Distributed generation can be both renewable and non-renewable. Addition of distributed generation is primarily to increase feeder capacity and to provide peak load reduction. However, this addition comes with several impacts on the distribution feeder. Several studies have shown that addition of DG leads to reduction of feeder loss. However, most of these studies have considered lumped load and distributed load models to analyze the effects on system losses, where the dynamic variation of load due to seasonal changes is ignored. It is very important for utilities to minimize the losses under all scenarios to decrease revenue losses, promote efficient asset utilization, and therefore, increase feeder capacity. This paper will investigate an IEEE 13-node feeder populated with photovoltaic generators on detailed residential houses with water heater, Heating Ventilation and Air conditioning (HVAC) units, lights, and other plug and convenience loads. An analysis of losses for different power system components, such as transformers, underground and overhead lines, and triplex lines, will be performed. The analysis will utilize different seasons and different solar penetration levels (15%, 30%).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic assessment of distributed generation hosting capacity and energy efficiency in active distribution networks

Active network management (ANM) aims to increase the capacity of variable distributed generation (DG), which can be connected to existing distribution networks. In this study, it is proposed to simultaneously consider the efficient use of energy resources when high shares of DG are procured through the ANM approach. To that end, a multi-period and multiobjective optimisation algorithm, based on the linearised optimal power flow, is formulated. The algorithm seeks to maximise the installed capacity of DG while minimising the energy losses and consumption of voltage-dependent loads. The objectives are optimised considering the coordinated operation of voltage regulators and on-load tap changers, and the management of DG generation curtailment and reactive power compensation from DG. Additionally, the effects of load and generation uncertainties are addressed through a two-stage stochastic programming formulation of the multiobjective problem. The result is a set of non-inferior solutions, which allows exploring the degree of conflict among the objectives. The proposed approach was tested on two IEEE test feeders and the solutions show a significant improvement in the system's energy efficiency with a low impact on the amount of connected DG.

Quijano, Darwin Alexis↗

Resilient Operating Constraints for Power Distribution Systems under Setpoint Attacks

Integration and operation of distributed generation (DG) and energy storage (ES) in power distribution systems are enabled by communication networks and embedded sensor and control devices that increase the vulnerability of the systems to cyber-threats, broadening the attack surface and making adversary actions more unpredictable. This paper proposes a methodology that uses ellipsoidal approximations to quantify the potential damage caused by successful attacks that affect, directly or indirectly, the desired operation setpoints and may drive the power distribution operation to unsafe states by violating the limits of voltage or line flows. More specifically, a new methodology is introduced to find the optimal non-symmetric operating constraints that can be imposed to each DG and ES in order to guarantee that the power distribution system is resilient to any malicious setpoints. The proposed method takes as inputs the system topology, DG and ES capabilities, and load limits to solve a convex optimization problem formulated using linear matrix inequalities (LMIs) and the power flow equations. The proposed solution is agnostic to the attacker's action or load profile and it does not require any assumption about the location or means of the attack. The numerical results on a test distribution feeder with several DG and ES illustrate how the proposed resilient operating constraints guarantee the security of the power distribution system under setpoint attacks.

Giraldo, Jairo↗