Engineering PapersSearch

SEARCH · Engineering Papers

Results for “direct detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation

Integrated photonic Galton board and its application for photon counting

The Galton board is a desktop probability machine traditionally used to visualize the principles of statistical physics from classical particles. Here, we demonstrate a photonic Galton board that enables on-chip observation of statistics from single-photon interference. The photonic Galton board consists of a directional coupler matrix terminated by an array of superconducting nanowire detectors to provide spatiotemporal resolution. This design also allows for photon-number-resolving capability, making it suitable for high-speed photon counting. Our results demonstrate the compatibility between single-photon detector array and photonic integrated circuits, paving the way for implementing on-chip large-scale quantum optics experiments and photonic quantum computing.

Qin, Hezheng (ORCID:0009000139348800)

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS

Real-time Anomaly Detection for Liquid Argon Time Projection Chambers

We present a real-time anomaly detection framework for liquid argon time projection chambers (LArTPCs), targeting applications in particle physics experiments such as the Short Baseline Near Detector (SBND) or the future Deep Underground Neutrino Experiment (DUNE). These experiments employ detectors that generate and stream high-resolution but sparse images of neutrino and other particle interactions. Our approach utilizes anomaly detection with autoencoders, compressed through knowledge distillation (KD), to enable the detection of anomalous signals in the data through efficient inference on resource-constrained hardware. The framework is targeted for deployment on computing platforms equipped with field-programmable gate arrays (FPGAs), GPUs, or CPUs, allowing low-latency selection of relevant activity directly from the raw detector data stream. We demonstrate that our approach is suitable for the detection and localization of anomalously "high-multiplicity" activity, and outline promising applications for LArTPC online data filtering and triggering.

FOS: Physical sciences

Identifying environmentally induced calibration changes in cryogenic RF axion detector systems using deep neural networks

The axion is a compelling hypothetical particle that could account for the dark matter in our universe while simultaneously solving the strong CP problem in quantum chromodynamics. The most sensitive axion detection technique demonstrated so far makes use of a high Q cavity immersed in a strong magnetic field, where axions are converted to microwave photons. This is called an axion haloscope and has primarily targeted the 1–10 GHz range. As searches scan up in axion mass, toward the parameter space favored by theoretical predictions, individual cavity sizes decrease in order to achieve higher frequencies. This shrinking cavity volume translates directly to a loss in signal-to-noise, motivating the plan to replace individual cavity detectors with arrays of cavities. When the transition from one to (N) multiple cavities occurs, haloscope searches are anticipated to become much more complicated to operate, requiring N times as many measurements but also the new requirement that N detectors operate in unison, which can be achieved by locking them to a common frequency. To offset this anticipated increase in detector complexity, we aim to develop new tools for diagnosing experiments using neural networks. Current experiments monitor scattering parameters of their receiver for periodically measuring cavity quality factor and coupling. However, off-resonant data remain relatively useless. In this paper, we ask if it is possible that off-resonant information contained in vector network analyzer scans could be used to diagnose equipment failures/anomalies and measure physical conditions (e.g., temperatures and ambient magnetic field). We demonstrate a proof-of-concept that AI techniques can help manage the complexity of an axion haloscope search for operators.

Engel, Andrew W. [Pacific Northwest National Labor

The Distribution of Ultrahigh-energy Cosmic Rays along the Supergalactic Plane Measured at the Pierre Auger Observatory

Ultrahigh-energy cosmic rays are known to be mainly of extragalactic origin, and their propagation is limited by energy losses, so their arrival directions are expected to correlate with the large-scale structure of the local Universe. In this work, we investigate the possible presence of intermediate-scale excesses in the flux of the most energetic cosmic rays from the direction of the supergalactic plane region using events with energies above 20 EeV recorded with the surface detector array of the Pierre Auger Observatory up to 2022 December 31, with a total exposure of 135,000 km 2 sr yr. The strongest indication for an excess that we find, with a posttrial significance of 3.1σ, is in the Centaurus region, as in our previous reports, and it extends down to lower energies than previously studied. We do not find any strong hints of excesses from any other region of the supergalactic plane at the same angular scale. In particular, our results do not confirm the reports by the Telescope Array Collaboration of excesses from two regions in the Northern Hemisphere at the edge of the field of view of the Pierre Auger Observatory. With a comparable integrated exposure over these regions, our results there are in good agreement with the expectations from an isotropic distribution.

Abdul Halim, A. [Univ. of Adelaide, SA (Australia)

Upgrade to Fixed and Translating Scintillation-based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating detectors collected under varying beam conditions validate the utility of the upgrade.

Chen, E. V. [Fermilab]

Rapid neutron and gamma-ray source localization using machine learning

Rapid localization of radiation sources is critical for applications including nuclear emergency response, safeguards, and security. However, conventional imaging systems such as neutron scatter cameras and Compton cameras depend on rare coincidence events, which often result in long acquisition times. In this work, we address the challenge of rapid source localization by developing a machine learning approach to predict the direction of a single radiation source using only count rates from an array of neutron and gamma-ray detectors. The proposed model is a fully connected neural network (FCNN) trained using Monte Carlo simulation data from a 252 Cf source. The model hyperparameters are optimized with a small set of routine 252 Cf measurements. We benchmarked the performance of the trained and optimized machine learning model using additional 252 Cf , 137 Cs , and PuBe measurements under laboratory conditions with varying source-detector configurations. For these measurements, the machine learning model achieved a mean localization error smaller than 30° with 3 x 10 3 system counts, corresponding to 8 s measurement time for the imaging system used in this work. In this low-statistics regime, the method outperformed traditional scatter-based imaging by more than 75% in localization accuracy for the evaluated measurement configurations. These results demonstrate that a machine learning-based approach can significantly reduce the time required for accurate single-source localization, providing a robust and computationally efficient alternative to traditional imaging systems in time-critical nuclear security and emergency response scenarios.

Gamma-ray imaging

Reply to “Comment on ‘The Reduced Detection Rate of Signals That Are Hidden by Earthquakes: Case Studies with Spotlight Detectors That Operate at Seismic Arrays,’ by Joshua D. Carmichael, Brent G. Delbridge, and Richard Alfaro-Diaz” by Paul G. Richards

We reply to a comment that Paul G. Richards (Richards, 2026) directed to an article by Carmichael et al. (2025). Richards expressed concern over two issues. The first issue relates to the size of the explosions discussed in the article. The second relates to the probability that earthquakes and explosions sourced near the same location coincide in time, by chance. We do not address the first issue because the original article does not assign significance to the size of the explosions from the point of view of an experimental party. We do respond to Richards’ comment on the second issue and claim that it can be explained through a clarification about conditional versus joint probabilities. Our present discussion, therefore, describes the difference between the conditional probability that a correlator fails, given that an explosion and earthquake coincidently occur in the same place, and the joint probability that a correlator fails while an earthquake and explosion also coincidentally occur in the same place. This latter, joint probability appears to be rare. We clarify that our original article did not treat the joint probability, only the conditional probability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF

Antenna arrays for neutrino mass measurements with cyclotron radiation emission spectroscopy

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurements of kinetic energies of charged particles, pioneered by the Project 8 experiment to measure the neutrino mass using the tritium end-point method. It was recently employed for the first time to measure the molecular tritium spectrum and place a limit on the neutrino mass using a cubic-centimeter-scale detector. Future direct neutrino mass experiments are developing the technique to overcome the systematic and statistical limitations of current detectors. Here, this paper describes one such approach, namely the use of antenna arrays for CRES in free space. Phenomenology, detector design, simulation, and performance estimates are discussed, culminating with an example design with a projected sensitivity of 𝑚 𝛽 < ⁢0.04 eV/𝑐 2 . Prototype antenna array measurements are also shown for a demonstrator-scale setup as a benchmark for the simulation. By consolidating these results, this paper serves as a comprehensive reference for the development and performance of antenna arrays for CRES.

Physics - Nuclear physics and radiation physics

X-ray Computed Tomography Data of Dense Metallic Components

The data shared in here are X-ray computed tomography (XCT) scans of a hexagonal fuel nozzle in 3 sections with the Metrotom 800 system at the Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory. The data are used in the paper "Tomographic Sparse View Selection using the View Covariance Loss, by Lin et al. (doi:10.1109/TPAMI.2025.36000720), accepted to the international conference on computational imaging (ICCP 2025). Figures 4-7 in the paper describe the part/XCT scan. File name Descriptions: Bottom section: TCR- Single Channeled SRC L 2019-3-18 12-26-41.hdf5 Medium section: TCR- Single Channeled SRC M 2019-3-18 13-8-9.hdf5 Top section: TCR- Single Channeled SRC T 2019-3-18 13-45-39.hdf5 Each hdf5 file contains projection data, and all the relevant X-ray CT scan setting. The full list of included attributes: distance_unit: Units of all distances specified angle_unit : Units of the angles angles: Array of all angles used voxel_size_xy: Baseline recon (if any) has this voxel size in the in-plane direction voxel_size_z: Baseline recon (if any) has this voxel size in the cross-plane direction det_pixel_size_col: Size of the detector pixels in the column dimension det_pixel_size_row: Size of the detector pixels in the row dimension src_iso_dist: Source to iso-center distance iso_det_dist: Iso-center to detector distance det_angle: If the detector is rotated/tilted, this angle corresponds to that value det_row_offset: Center of rotation offset in the vertical direction det_col_offset: Center of rotation offset in the horizontal direction reconstruction: A baseline reconstruction stored as 3D array BHC params: Beam-hardening parameters - Van De Casteel Model - if it has been used to pre-process the projections We also provided a python script (hdf_io.py) that allows the user to read the relevant data from each hdf5 file.

Ziabari, Amir [Oak Ridge National Laboratory]

Upgrade to Fixed and Translating Scintillation-Based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and op-erational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating de-tectors collected under varying beam conditions validate the utility of the upgrade.

Chen, Erin V. [Fermilab] (ORCID:0000000215467899)

Demonstration of neutron time-of-flight diffraction with an event-mode imaging detector

Neutron diffraction beamlines have traditionally relied on deploying large detector arrays of 3 He tubes or neutron-sensitive scintillators coupled with photomultipliers to efficiently probe crystallographic and microstructure information of a given material. Given the large upfront cost of custom-made data acquisition systems and the recent scarcity of 3 He, new diffraction beamlines or upgrades to existing ones demand innovative approaches. This paper introduces a novel Timepix3-based event-mode imaging neutron diffraction detector system as well as first results of a silicon powder diffraction measurement made at the HIPPO neutron powder diffractometer at the Los Alamos Neutron Science Center. Notably, these initial measurements were conducted simultaneously with the 3 He array on HIPPO, enabling direct comparison. Data reduction for this type of data was implemented in the MAUD code, enabling Rietveld analysis. Results from the Timepix3-based setup and HIPPO were benchmarked against McStas simulations, showing good agreement for peak resolution. With further development, systems such as the one presented here may substantially reduce the cost of detector systems for new neutron instrumentation as well as for upgrades of existing beamlines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Synchronous detection of cosmic rays and correlated errors in superconducting qubit arrays

Quantum information processing at scale will require sufficiently stable and long-lived qubits, likely enabled by error-correction codes. Several recent superconducting-qubit experiments, however, reported observing intermittent spatiotemporally correlated errors that would be problematic for conventional codes, with ionizing radiation being a likely cause. Here, we directly measured the cosmic-ray contribution to spatiotemporally correlated qubit errors. We accomplished this by synchronously monitoring cosmic-ray detectors and qubit energy-relaxation dynamics of 10 transmon qubits distributed across a 5 × 5 × 0.35 mm 3 silicon chip. Cosmic rays caused correlated errors at a rate of $1/\left(592\begin{array}{c}+48\\ -41\end{array}\,{\rm{s}}\right)$, accounting for 17.1 ± 1.3% of all such events. Our qubits responded to essentially all of the cosmic rays and their secondary particles incident on the chip, consistent with the independently measured arrival flux. Moreover, we observed that the landscape of the superconducting gap in proximity to the Josephson junctions dramatically impacts the qubit response to cosmic rays. Given the practical difficulties associated with shielding cosmic rays, our results indicate the importance of radiation hardening—for example, superconducting gap engineering—to the realization of robust quantum error correction.

Science & Technology - Other Topics

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION

Forward modeling approach to nuclear reaction cross sections: Applications in neutron inelastic scattering

The development of nuclear reaction models for the production of evaluated nuclear data has traditionally been performed by comparing measured cross sections with predictions from reaction model codes whose physical input parameters are adjusted to obtain the best agreement between measured and modeled results. To more directly probe reaction model inputs, this work introduces a forward modeling approach to experimental reaction cross-section determination, where the most important physical input parameters to reaction model calculations are obtained via 𝜒 2 minimization between measured and calculated observables. This was demonstrated using data collected by the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) at the 88-inch cyclotron at Lawrence Berkeley National Laboratory, a detection array consisting of organic liquid scintillators and high-purity germanium (HPGe) detectors. Using a broad-spectrum neutron beam and a 99.98%-enriched 56 Fe target, GENESIS was used to perform a simultaneous measurement of 56 Fe 𝛾-ray production cross sections and secondary neutron energy and angle distributions. The results of the forward modeling approach to the determination of energy-differential 𝛾-ray production cross sections for the yrast 4 + → 2 + and 6 + → 4 + transitions, as well as eight other off-yrast transitions, were compared against those obtained using conventional techniques, and the results are in good agreement. In addition to discrete 𝛾-ray yield total scattered neutron energy-angular distributions as a function of incident neutron energy were also obtained using forward modeling and found to agree with evaluated data, with the exception of elastic scattering at small angles. The fitted reaction model parameters obtained through forward modeling were also used to calculate the cross section for the unobserved (𝑛, 2⁢𝑛) reaction; excellent agreement with the current evaluation was obtained, providing a validation of the predictive capabilities of the forward model approach. This work bridges the gap between nuclear data experiment and evaluation by providing a new means for extracting inelastic neutron-scattering cross sections and neutron-induced 𝛾-ray production data while directly probing reaction model physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS