Engineering PapersSearch

SEARCH · Engineering Papers

Results for “detector non-linearity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development and Utility of a Four-Channel Scanner for Wildland Fire Research and Applications

The Airborne Infrared Disaster Assessment System (AIRDAS) is a four-channel scanner designed and built at NASA-Ames for the specific task of supporting research and applications on fire impacts on terrestrial and atmospheric processes and also of serving as a vital instrument in the assessment of natural and man-induced disasters. The system has been flown on numerous airframes including the Navajo, King-Air, C0130, and Lear Jet 310 and a 206. The system includes a configuration composed of a 386 PC computer workstation, a non-linear detector amplifier, a sixteen-bit digitizer, dichroic filters, and Exabyte 8500 5Gb Tape output, VHS tape output, a Rockwell GPS and a 2-axis gyro. The AIRDAS system collects digital data in four wavelength regions, which can be filtered: band 1 (0.61-0.68 microns), band 2 (1.57-1.7 microns), band 3 (3.6-5.5 microns), and band 4 (5.5-13.0 microns), an FOV of 108 degrees, an IFOV of 2.62 mrads, and a digitized swath width of 720 pixels. The inclusion of the non-linear detector amplifier allows for the accurate measurement of emitted temperature from fires and hot spots. Lab testing of the scanner has indicated temperature assessments of 800 C without detector saturation. This has advantages over previous systems which were designed for thermal measurement of earth background temperatures, and were ill-equipped for accurate determination of high intensity conditions. The scanner has been flown successfully on data collection missions since 1992 in the western US as well as Brazil. These and other research and applications responses will be presented along with an assessment of future directions with the system.a

Ambrosia, Vincent G.

High Resolution Doppler Lidar

This Grant supported the development of an incoherent lidar system to measure winds and aerosols in the lower atmosphere. During this period the following activities occurred: (1) an active feedback system was developed to improve the laser frequency stability; (2) a detailed forward model of the instrument was developed to take into account many subtle effects, such as detector non-linearity; (3) a non-linear least squares inversion method was developed to recover the Doppler shift and aerosol backscatter without requiring assumptions about the molecular component of the signal; (4) a study was done of the effects of systematic errors due to multiple etalon misalignment. It was discovered that even for small offsets and high aerosol loadings, the wind determination can be biased by as much as 1 m/s. The forward model and inversion process were modified to account for this effect; and (5) the lidar measurements were validated using rawinsonde balloon measurements. The measurements were found to be in agreement within 1-2 m/s.

Source record

Detector noise statistics in the non-linear regime

The statistical behavior of an idealized linear detector in the presence of threshold and saturation levels is examined. It is assumed that the noise is governed by the statistical fluctuations in the number of photons emitted by the source during an exposure. Since physical detectors cannot have infinite dynamic range, our model illustrates that all devices have non-linear regimes, particularly at high count rates. The primary effect is a decrease in the statistical variance about the mean signal due to a portion of the expected noise distribution being removed via clipping. Higher order statistical moments are also examined, in particular, skewness and kurtosis. In principle, the expected distortion in the detector noise characteristics can be calibrated using flatfield observations with count rates matched to the observations. For this purpose, some basic statistical methods that utilize Fourier analysis techniques are described.

Shopbell, P. L.

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Implementation and Assessment of Advanced Analog Vector-Matrix Processor

This paper discusses the design and implementation of an analog optical vecto-rmatrix coprocessor with a throughput of 128 Mops for a personal computer. Vector matrix calculations are inherently parallel, providing a promising domain for the use of optical calculators. However, to date, digital optical systems have proven too cumbersome to replace electronics, and analog processors have not demonstrated sufficient accuracy in large scale systems. The goal of the work described in this paper is to demonstrate a viable optical coprocessor for linear operations. The analog optical processor presented has been integrated with a personal computer to provide full functionality and is the first demonstration of an optical linear algebra processor with a throughput greater than 100 Mops. The optical vector matrix processor consists of a laser diode source, an acoustooptical modulator array to input the vector information, a liquid crystal spatial light modulator to input the matrix information, an avalanche photodiode array to read out the result vector of the vector matrix multiplication, as well as transport optics and the electronics necessary to drive the optical modulators and interface to the computer. The intent of this research is to provide a low cost, highly energy efficient coprocessor for linear operations. Measurements of the analog accuracy of the processor performing 128 Mops are presented along with an assessment of the implications for future systems. A range of noise sources, including cross-talk, source amplitude fluctuations, shot noise at the detector, and non-linearities of the optoelectronic components are measured and compared to determine the most significant source of error. The possibilities for reducing these sources of error are discussed. Also, the total error is compared with that expected from a statistical analysis of the individual components and their relation to the vector-matrix operation. The sufficiency of the measured accuracy of the processor is compared with that required for a range of typical problems. Calculations resolving alloy concentrations from spectral plume data of rocket engines are implemented on the optical processor, demonstrating its sufficiency for this problem. We also show how this technology can be easily extended to a 100 x 100 10 MHz (200 Cops) processor.

Gary, Charles K.

TM Geometric Performance: Line to Line Displacement Analysis (LLDA)

An early acquired TM data frame (track 23, frame 35 of 22 August 1982) was used to assess the geometric performance of the LANDSAT-4 thematic mapper instrument. The developed method consists in determining the displacements of adjacent lines by locating the maximum of the correlation profile between the two lines. Then the line to line displacement is used to characterize the TM instrument in respect to: scan to scan jitter and image skew, scan profile non-linearity, along scan jitter, detector to detector displacement, and band to band displacement. To verify the quality of the reported performance parameters, some extracted geometric parameters were used to correct the original raw data. Comparison between P-tape data and results of reprocessed data shows no significant differences in an area of 1024 x 1024 pixels.

Fusco, L.

The human oculomotor response to simultaneous visual and physical movements at two different frequencies

In order to investigate interactions in the visual and vestibular systems' oculomotor response to linear movement, we developed a two-frequency stimulation technique. Thirteen subjects lay on their backs and were oscillated sinusoidally along their z-axes at between 0.31 and 0.81 Hz. During the oscillation subjects viewed a large, high-contrast, visual pattern oscillating in the same direction as the physical motion but at a different, non-harmonically related frequency. The evoked eye movements were measured by video-oculography and spectrally analysed. We found significant signal level at the sum and difference frequencies as well as at other frequencies not present in either stimulus. The emergence of new frequencies indicates non-linear processing consistent with an agreement-detector system that have previously proposed.

NASA Discipline Neuroscience

Acquisition and Tracking Behavior of Phase-Locked Loops

Phase-locked or APC loops have found increasing applications in recent years as tracking filters, synchronizing devices, and narrowband FM discriminators. Considerable work has been performed to determine the noise-squelching properties of the loop when it is operating in or near phase lock and is functioning as a linear coherent detector. However, insufficient consideration has been devoted to the non-linear behavior of the loop when it is out of lock and in the process of pulling in. Experimental evidence has indicated that there is a strong tendency for phase-locked loops to achieve lock under most circumstances. However, the analysis which has appeared in the literature iis limited to the acquisition of a constant frequency reference signal with only one phase-locked loop filter configuration. This work represents an investigation of frequency acquisition properties of phase-locked loops for a variety of reference-signal behavior and loop configurations

Viterbi, A. J.

Consortium for materials development in space

The status of the Consortium for Materials Development in Space (CMDS) is reviewed. Individual CMDS materials projects and flight opportunities on suborbital and orbital carriers are outlined. Projects include: surface coatings and catalyst production; non-linear optical organic materials; physical properties of immiscible polymers; nuclear track detectors; powdered metal sintering; iron-carbon solidification; high-temperature superconductors; physical vapor transport crystal growth; materials preparation and longevity in hyperthermal oxygen; foam formation; measurement of the microgravity environment; and commercial management of space fluids.

Source record

An algorithm for the estimation of bounds on the emissivity and temperatures from thermal multispectral airborne remotely sensed data

The effective flux incident upon the detectors of a thermal sensor, after it has been corrected for atmospheric effects, is a function of a non-linear combination of the emissivity of the target for that channel and the temperature of the target. The sensor system cannot separate the contribution from the emissivity and the temperature that constitute the flux value. A method that estimates the bounds on these temperatures and emissivities from thermal data is described. This method is then tested with remotely sensed data obtained from NASA's Thermal Infrared Multispectral Scanner (TIMS) - a 6 channel thermal sensor. Since this is an under-determined set of equations i.e. there are 7 unknowns (6 emissivities and 1 temperature) and 6 equations (corresponding to the 6 channel fluxes), there exist theoretically an infinite combination of values of emissivities and temperature that can satisfy these equations. Using some realistic bounds on the emissivities, bounds on the temperature are calculated. These bounds on the temperature are refined to estimate a tighter bound on the emissivity of the source. An error analysis is also carried out to quantitatively determine the extent of uncertainty introduced in the estimate of these parameters. This method is useful only when a realistic set of bounds can be obtained for the emissivities of the data. In the case of water the lower and upper bounds were set at 0.97 and 1.00 respectively. Five flights were flown in succession at altitudes of 2 km (low), 6 km (mid), 12 km (high), and then back again at 6 km and 2 km. The area selected with the Ross Barnett reservoir near Jackson, Mississippi. The mission was flown during the predawn hours of 1 Feb. 1992. Radiosonde data was collected for that duration to profile the characteristics of the atmosphere. Ground truth temperatures using thermometers and radiometers were also obtained over an area of the reservoir. The results of two independent runs of the radiometer data averaged 7.03 plus or minus .70 for the first run and 7.31 plus or minus .88 for the second run. The results of the algorithm yield a temperature of 7.68 for the low altitude data to 8.73 for the high altitude data.

Jaggi, S.

A machine learning framework for accurate and robust analysis of radiation detector pulses

The microscopic properties of atomic nuclei are used to study various scientific questions. They are essential for understanding the fundamental forces of nature and the chemical evolution of the universe. Detecting decay radiation from radioactive nuclei makes it possible to probe these fundamental nuclear properties. Detector waveform traces may contain additional information about the radiation. Generally, advanced signal processing techniques are needed to extract this additional information, often involving fitting the waveform with model response functions using non-linear least-squares optimization with second-order gradient methods. While this is a powerful technique, it is also computationally expensive, leading to slow processing time, which scales with the volume of data. To address this problem, we have developed a machine learning (ML) approach that infers the characteristics of traces from a model detector response function. In particular, we are interested in classifying whether a single recorded trace consists of one or two pulse constituents and estimating the pulse parameters. Furthermore, our proposed ML method can precisely extract the pulses’ parameters, such as energy and timing information, and accurately classify the pulse multiplicity of a trace. Unlike non-learning-based approaches, our ML approach uses neural networks that are significantly faster at inference, as they do not require any optimization during this stage.

Curve fitting

Near UV atmospheric absorption measurements from the DC-8 aircraft during the 1987 airborne Antarctic ozone experiment

During the Airborne Antarctic Ozone Experiment from 28 August to 30 September 1987 near UV zenith scattered sky measurements were made over Antarctic from the NASA DC-8 aircraft using a one third m spectrograph equipped with a diode-array detector. Scattered sky light data in the wavelength range 348 nm to 388 nm was spectrally analyzed for O3, NO2, OClO, and BrO column abundances. Slant column abudances of O3, NO2, OClO and BrO were determined, using a computer algorithm of non-linear and linear least square correlation of Antarctic scattered sky spectra to laboratory absorption cross section data. Using measured vertical electrochemical sonde ozone profiles from Palmer, Halley Bay, and the South Pole Stations the slant columns of O3 were converted into vertical column abundances. The vertical column amounts of NO2, OClO, and BrO were derived using vertical profiles calculated by a chemical model appropriate for Antarctica. NO2 vertical column abundances show steep latitudinal decrease with increasing latitude for all 13 flights carried out during the mission. In the regions where NO2 abudances are low, OClO and BrO were observed. The spatial and temporal vertical column abundances of these species are discussed in the context of the chemistry and dynamics in the antarctic polar vortex during the austral spring.

Wahner, A.

Particle Velocity Measuring System

Method and apparatus are provided for determining the velocity of individual food particles within a liquid/solid food mixture that is cooked by an aseptic cooking method whereby the food mixture is heated as it flows through a flowline. At least one upstream and at least one downstream microwave transducer are provided to determine the minimum possible travel time of the fastest food particle through the flowline. In one embodiment, the upstream detector is not required. In another embodiment, a plurality of small dipole antenna markers are secured to a plurality of food particles to provide a plurality of signals as the markers pass the upstream and downstream transducers. The dipole antenna markers may also include a non-linear element to reradiate a harmonic frequency of a transmitter frequency. Upstream and downstream transducers include dipole antennas that are matched to the impedance of the food slurry and a signal transmission cable by various impedance matching means including unbalanced feed to the antennas.

Arndt, G. Dickey

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.

Study of spectral/radiometric characteristics of the thematic mapper for land use applications

The previous characterization of scan-related low-frequency noise was confirmed and extended through analysis of reflective-band data from another nighttime acquisition. Amplitude and phase relationships of the level shifts were determined for each detector in each of free full frames. Analysis of scan-direction-related signal droop effects in nighttime data from the reflective bands was begun with encouraging initial observations. Also, an effort to characterize high-frequency noise in the reflective bands through Fourier analysis of nighttime data was initiated. Recommendations are made relative to the choice of radiometric calibration constants in the thematic mapper image processing system for the routine processing of TM data. Non-linear (piece-wise linear) calibration curves are recommended.

Malila, W. A.

The Nagoya cosmic-ray muon spectrometer 3, part 4: Track reconstruction method

One of the greatest problems in measuring particle trajectories with an optical or visual detector system, is the reconstruction of trajectories in real space from their recorded images. In the Nagoya cosmic-ray muon spectrometer, muon tracks are detected by wide gap spark chambers and their images are recorded on the photographic film through an optical system of 10 mirrors and two cameras. For the spatial reconstruction, 42 parameters of the optical system should be known to determine the configuration of this system. It is almost impossible to measure this many parameters directly with usual techniques. In order to solve this problem, the inverse transformation method was applied. In this method, all the optical parameters are determined from the locations of fiducial marks in real space and the locations of their images on the photographic film by the non-linear least square fitting.

Shibata, S.

Pulsations, Shocks, and Mass Loss

This grant provided long-term support for my investigation of the outflows powered by young stars. Several major research results emerged during the course of this research, including: (1) The discovery of giant Herbig-Haro outflows from young stars that can extend for many parsecs from their sources. The first parsec-scale outflow to be recognized led to the realization that Herbig-Haro outflows, even those produced by low mass young stellar objects, can extend orders of magnitude farther from their sources than previously thought. Our preconceptions were to a large extent driven by the narrow fields-of-view then provided by CCD detectors. With the recent advent of large format CCDs and CCD mosaics, we have come to realize that most outflows attain parsec-scale dimensions. Even at the distance of the Orion star forming clouds, such flows can subtend a degree on the sky. Our work has led to the recognition of over two dozen giant. (2) The discovery that outflows are highly clustered. Even regions of relatively isolated star formation such as those in Taurus frequently produce multiple outflows. (3) The discovery of a new family of externally irradiated jets. During the last year of support from this grant, we made the startling discovery that there is a class of jets from young stars that are illuminated by the ionizing radiation field of nearby massive stars. The first four examples were discovered in the vicinity of the a Orionis sub-group of the Orion OB Association which is believed to be at least 2 million years old. Since the jets are photo-ionized, their densities can be reliably estimated. Most HH jets are shock excited, and are therefore notoriously difficult to characterize since their visibility and observed properties depend on the complex and highly non-linear processes associated with shocks. Furthermore, many irradiated jets are one sided rather than bipolar. Thus, irradiated jets may for the first time be used to accurately diagnose jet densities and mass loss rates, and to probe the physics of jet collimation, and may indicate that the jet production phase of certain young stars may last more than a million years. These three discoveries provide us with fundamental new insights into the star formation process, into the physical conditions inside and near star forming clouds, and into new ways to probe the physics and chemistry of such clouds.

Bally, John

Charge Resolution of the Silicon Matrix of the ATIC Experiment

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CRT particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2001. The ATIC flight collected approximately 25 million events. The silicon matrix of the ATIC spectrometer is designed to resolve individual elements from proton to iron. To provide this resolution careful calibration of each pixel of the silicon matrix is required. Firstly, for each electronic channel of the matrix the pedestal value was subtracted taking into account its drift during the flight. The muon calibration made before the flight was used then to convert electric signals (in ADC channel number) to energy deposits in each pixel. However, the preflight muon calibration was not accurate enough for the purpose, because of lack of statistics in each pixel. To improve charge resolution the correction was done for the position of Helium peak in each pixel during the flight . The other way to set electric signals in electronics channels of the Si-matrix to one scale was correction for electric channel gains accurately measured in laboratory. In these measurements it was found that small different nonlinearities for different channels are present in the region of charge Z > 20. The correction for these non-linearities was not done yet. In linear approximation the method provides practically the same resolution as muon calibration plus He-peak correction. For searching a pixel with the signal of primary particle an indication from the cascade in the calorimeter was used. For this purpose a trajectory was reconstructed using weight centers of energy deposits in BGO layers. The point of intersection of this trajectory with Si-matrix and its RMS was determined. The pixel with maximal signal in 3sigma region was taken as sought. The signal in this pixel was corrected by trajectory zenith angle. The preliminary results on charge resolution of the Si-matrix in the range from protons to iron are presented.

Zatsepin, V. I.