Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector alignment and calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

The CMS Phase-1 Pixel Detector Upgrade

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

AI-assisted detector design for the EIC (AID(2)E)

Artificial Intelligence is poised to transform the design of complex, large-scale detectors like ePIC at the future Electron Ion Collider. Featuring a central detector with additional detecting systems in the far forward and far backward regions, the ePIC experiment incorporates numerous design parameters and objectives, including performance, physics reach, and cost, constrained by mechanical and geometric limits. This project aims to develop a scalable, distributed AI-assisted detector design for the EIC (AID(2)E), employing state-of-the-art multiobjective optimization to tackle complex designs. Supported by the ePIC software stack and using G EANT 4 simulations, our approach benefits from transparent parameterization and advanced AI features. The workflow leverages the PanDA and iDDS systems, used in major experiments such as ATLAS at CERN LHC, the Rubin Observatory, and sPHENIX at RHIC, to manage the compute intensive demands of ePIC detector simulations. Tailored enhancements to the PanDA system focus on usability, scalability, automation, and monitoring. Ultimately, this project aims to establish a robust design capability, apply a distributed AI-assisted workflow to the ePIC detector, and extend its applications to the design of the second detector (Detector-2) in the EIC, as well as to calibration and alignment tasks. Additionally, we are developing advanced data science tools to efficiently navigate the complex, multidimensional trade-offs identified through this optimization process.

97 MATHEMATICS AND COMPUTING↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗

Design, construction and commissioning of a technological prototype of a highly granular SiPM-on-tile scintillator-steel hadronic calorimeter

The CALICE collaboration is developing highly granular electromagnetic and hadronic calorimeters for detectors at future energy frontier electron-positron colliders. After successful tests of a physics prototype, a technological prototype of the Analog Hadron Calorimeter has been built, based on a design and construction techniques scalable to a collider detector. The prototype consists of a steel absorber structure and active layers of small scintillator tiles that are individually read out by directly coupled SiPMs. Each layer has an active area of 72 × 72 cm^2 and a tile size of 3 × 3 cm^2. With 38 active layers, the prototype has nearly 22,000 readout channels, and its total thickness amounts to 4.4 nuclear interaction lengths. The dedicated readout electronics provide time stamping of each hit with an expected resolution of about 1 ns. The prototype was constructed in 2017 and commissioned in beam tests at DESY. It recorded muons, hadron showers and electron showers at different energies in test beams at CERN in 2018. In this paper, the design of the prototype, its construction and commissioning are described. The methods used to calibrate the detector are detailed, and the performance achieved in terms of uniformity and stability is presented.

47 OTHER INSTRUMENTATION↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. Here, the expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

47 OTHER INSTRUMENTATION↗

A laserball calibration device for the SNO+ scintillator phase

Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype acoustic positioning system for the Pacific Ocean Neutrino Experiment

We present the design and initial performance characterization of the prototype acoustic positioning system intended for the Pacific Ocean Neutrino Experiment. It comprises novel piezo-acoustic receivers with dedicated filtering- and amplification electronics installed in P-ONE instruments and is complemented by a commercial system comprised of cabled and autonomous acoustic pingers for sub-sea installation manufactured by Sonardyne Ltd. We performed an in-depth characterization of the acoustic receiver electronics and their acoustic sensitivity when integrated into P-ONE pressure housings. These show absolute sensitivities of up to -125 dB re V2/μPa2 in a frequency range of 10–40 kHz. We furthermore conducted a positioning measurement campaign in the ocean by deploying three autonomous acoustic pingers on the seafloor, as well as a cabled acoustic interrogator and a P-ONE prototype module deployed from a ship. Using a simple peak-finding detection algorithm, we observe high accuracy in the tracking of relative ranging times at approximately 230–280 μs at distances of up to 1600 m, which is sufficient for positioning detectors in a cubic-kilometer detector and which can be further improved with more involved detection algorithms. The tracking accuracy is further confirmed by independent ranging of the Sonardyne system and closely follows the ship's drift in the wind measured by GPS. The absolute positioning shows the same tracking accuracy with its absolute precision only limited by the large uncertainties of the deployed pinger positions on the seafloor.

Data analysis↗

SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. Finally, we find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.

47 OTHER INSTRUMENTATION↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

AI for Experimental Controls at Jefferson Lab

We report the AI for Experimental Controls project is developing an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Chamber (CDC) located inside the GlueX spectrometer in Hall D. We use a combination of environmental and experimental data, such as atmospheric pressure, gas temperature, and the flux of incident particles as inputs to a sequential Neural Network (NN) to recommend a high voltage setting and the corresponding calibration constants in order to maintain consistent gain and optimal resolution throughout the experiment. Utilizing AI in this manner represents an initial shift from offline calibration towards near real time calibrations performed at Jefferson Laboratory.

47 OTHER INSTRUMENTATION↗

Operation modes of the KATRIN experiment Tritium Loop System using 83m Kr

The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to search for the effective electron antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.). In order to achieve this goal, KATRIN measurement phases focusing on the neutrino mass search are alternated with phases of investigations of systematic effects. During these phases, metastable 83m Kr is used as a calibration source. The monoenergetic conversion electrons emitted accompanying the decay of 83m Kr allow a direct access to the starting conditions of β-electrons produced inside the windowless gaseous tritium source (WGTS) of KATRIN. To make use of 83m Kr in the WGTS, the Tritium Loop System, which provides a stable flow of tritium to the WGTS, needs to be operated in special modes. This paper focuses on the technical implementation of these modes and their performance with regard to the achievable 83m Kr-rates, gas densities, and gas compositions inside the WGTS.

47 OTHER INSTRUMENTATION↗

The LED calibration systems for the mDOM and D-Egg sensor modules of the IceCube Upgrade: Design, production, testing and use in module calibration

The IceCube Neutrino Observatory, instrumenting about 1 km 3 of deep, glacial ice at the geographic South Pole, is due to be enhanced with the IceCube Upgrade. The IceCube Upgrade, to be deployed during the 2025/26 Antarctic summer season, will consist of seven new strings of photosensors, densely embedded near the bottom center of the existing array. Aside from a world-leading sensitivity to neutrino oscillations, a primary goal is the improvement of the calibration of the optical properties of the instrumented ice. This calibration will be applied to the entire archive of IceCube data, improving the angular and energy resolution of the detected neutrino events. For this purpose, the Upgrade strings include a host of new calibration devices. Aside from dedicated calibration modules, several thousand LED flashers have been incorporated into the photosensor modules. We describe the design, production, and testing of these LED flashers before their integration into the sensor modules as well as the use of the LED flashers during lab testing of assembled sensor modules.

Analogue electronic circuits↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Detector alignment for X-ray crystallography using Millepede-II

I describe a method for accurately refining the geometrical parameters of segmented X-ray area detectors on the basis of serial crystallography data, using 'Millepede' – an algorithm created for a very similar problem in high-energy physics. The Millepede method for serial crystallography builds on the approach of Brewster et al. [Acta Cryst. (2018), D74, 877–894], in which the detector parameters are refined simultaneously with the parameters for each individual crystal. This accounts for the mutual dependency between the parameters and thereby avoids the bias and slow convergence problems that have afflicted older approaches in which the deviations between observed and calculated Bragg peak positions were taken directly as the updates for the detector panel positions. The Millepede method uses the special structure of the least-squares normal equations to reduce them to a much smaller form that can be solved very quickly, even compared with the sparse matrix methods used previously. This makes it practical to refine the detector geometry frequently and thereby maintain accurate calibration without specialized alignment campaigns. Tilts of detector panels out of the plane can be reliably refined, as can the overall distance of the detector in the beam direction. With a simulated test case, the new method produced panel shifts within 7% of the correct values with only one iteration, and produced almost exactly correct shifts after a second iteration. A simulated out-of-plane panel rotation was correctly determined to within 0.001°. Applied to experimental data from an X-ray free-electron laser, the method increased the indexable fraction of frames from 30% to 91% in a single iteration, and to 96% after two further iterations. Computing the geometry updates on the basis of 2060 crystals took only 0.819 s on desktop computing hardware, including the time taken to read the required data from disk. The scaling was found to be very close to linear for up to 100 980 sets of crystal parameters, which took only 78.2 s to process under the same conditions. The method has been applied as part of a real-time feedback system at a synchrotron radiation beamline, in which an out-of-plane detector tilt of 0.04° was detected and corrected. Possible further applications are also described here.

Millepede-II↗