At least 19 records

Self-benchmarking Guide for Data Centers: Metrics, Benchmarks, Actions

This guide describes energy efficiency metrics and benchmarks that can be used to track the performance of and identify potential opportunities to reduce energy use in data centers. This guide is primarily intended for personnel who have responsibility for managing energy use in existing data centers - including facilities managers, energy managers, and their engineering consultants. Additionally, data center designers may also use the metrics and benchmarks described in this guide for goal-setting in new construction or major renovation. This guide provides the following information: (1) A step-by-step outline of the benchmarking process. (2) A set of performance metrics for the whole building as well as individual systems. For each metric, the guide provides a definition, performance benchmarks, and potential actions that can be inferred from evaluating this metric. (3) A list and descriptions of the data required for computing the metrics. This guide is complemented by spreadsheet templates for data collection and for computing the benchmarking metrics. This guide builds on prior data center benchmarking studies supported by the California Energy Commission. Much of the benchmarking data are drawn from the LBNL data center benchmarking database that was developed from these studies. Additional benchmark data were obtained from engineering experts including facility designers and energy managers. This guide also builds on recent research supported by the U.S. Department of Energy's Save Energy Now program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementing the Data Center Energy Productivity Metric

As data centers proliferate in both size and number, their energy efficiency is becoming increasingly important. We discuss the properties of a number of the proposed metrics of energy efficiency and productivity. In particular, we focus on the Data Center Energy Productivity (DCeP) metric, which is the ratio of useful work produced by the data center to the energy consumed performing that work. We describe our approach for using DCeP as the principal outcome of a designed experiment using a highly instrumented, high performance computing data center. We found that DCeP was successful in clearly distinguishing between different operational states in the data center, thereby validating its utility as a metric for identifying configurations of hardware and software that would improve (or even maximize) energy productivity. We also discuss some of the challenges and benefits associated with implementing the DCeP metric, and we examine the efficacy of the metric in making comparisons within a data center and among data centers.

Sego, Landon H↗

Towards the Net-Zero Data Center: Development and Application of an Energy Reuse Metric

Data Centers are an ever increasing user of energy in our economy. While the performance per watt of our IT equipment continues to increase exponentially, this energy performance improvement is still outstripped by increasing demand. Because of this, the efficiency of data centers must continue to improve. Beyond just efficiency, many data centers now are working towards reuse of their waste energy in other areas in the data center or on the site or campus. How to account for this, through metrics and measurements, is the topic of this paper. The Energy Reuse Effectiveness metric or ERE is discussed; both the development and application of the metric are looked at in detail. The use of ERE in conjunction with PUE (Power Usage Effectiveness) is also considered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementing the Data Center Energy Productivity Metric in a High Performance Computing Data Center

As data centers proliferate in size and number, the improvement of their energy efficiency and productivity has become an economic and environmental imperative. Making these improvements requires metrics that are robust, interpretable, and practical. We discuss the properties of a number of the proposed metrics of energy efficiency and productivity. In particular, we focus on the Data Center Energy Productivity (DCeP) metric, which is the ratio of useful work produced by the data center to the energy consumed performing that work. We describe our approach for using DCeP as the principal outcome of a designed experiment using a highly instrumented, high-performance computing data center. We found that DCeP was successful in clearly distinguishing different operational states in the data center, thereby validating its utility as a metric for identifying configurations of hardware and software that would improve energy productivity. We also discuss some of the challenges and benefits associated with implementing the DCeP metric, and we examine the efficacy of the metric in making comparisons within a data center and between data centers.

Sego, Landon H.↗

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

Data centers are among the most energy intensive types of facilities, and they are growing dramatically in terms of size and intensity [EPA 2007]. As a result, in the last few years there has been increasing interest from stakeholders - ranging from data center managers to policy makers - to improve the energy efficiency of data centers, and there are several industry and government organizations that have developed tools, guidelines, and training programs. There are many opportunities to reduce energy use in data centers and benchmarking studies reveal a wide range of efficiency practices. Data center operators may not be aware of how efficient their facility may be relative to their peers, even for the same levels of service. Benchmarking is an effective way to compare one facility to another, and also to track the performance of a given facility over time. Toward that end, this article presents the key metrics that facility managers can use to assess, track, and manage the efficiency of the infrastructure systems in data centers, and thereby identify potential efficiency actions. Most of the benchmarking data presented in this article are drawn from the data center benchmarking database at Lawrence Berkeley National Laboratory (LBNL). The database was developed from studies commissioned by the California Energy Commission, Pacific Gas and Electric Co., the U.S. Department of Energy and the New York State Energy Research and Development Authority.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Data Center Energy Opportunities: Cloud and Infrastructure CoP - Data Center Energy and Efficiency with AI Adoption

The NLR portion of the "Cloud & Infrastructure CoP - Data Center Energy and Efficiency with AI Adoption" web meeting will cover data center locations, energy use and load growth, best practices, performance metrics, transition to direct liquid cooled data center equipment, and NLR's approach to optimizing data center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Best Practices Guide for Energy-Efficient Data Center Design

This guide provides an overview of best practices for energy-efficient data center design which spans the categories of information technology (IT) systems and their environmental conditions, data center air management, cooling and electrical systems, and heat recovery. IT system energy efficiency and environmental conditions are presented first because measures taken in these areas have a cascading effect of secondary energy savings for the mechanical and electrical systems. This guide concludes with a section on metrics and benchmarking values by which a data center and its systems energy efficiency can be evaluated. No design guide can offer “the most energy-efficient” data center design but the guidelines that follow offer suggestions that provide efficiency benefits for a wide variety of data center scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CHP REGIONAL APPLICATION CENTERS: A PRELIMINARY INVENTORY OF ACTIVITIES AND SELECTED RESULTS

Eight Regional CHP Application Centers (RACs) are funded by the U.S. Department of Energy (DOE) to facilitate the development and deployment of Combined Heat and Power (CHP) technologies in all 50 states. The RACs build end-user awareness by providing CHP-related information to targeted markets through education and outreach; they work with the states and regulators to encourage the creation and adoption of favorable public policies; and they provide CHP users and prospective users with technical assistance and support on specific projects. The RACs were started by DOE as a pilot program in 2001 to support the National CHP Roadmap developed by industry to accelerate deployment of energy efficient CHP technologies (U.S. Combined Heat and Power Association 2001). The intent was to foster a regional presence to build market awareness, address policy issues, and facilitate project development. Oak Ridge National Laboratory (ORNL) has supported DOE with the RAC program since its inception. In 2007, ORNL led a cooperative effort involving DOE and some CHP industry stakeholders to establish quantitative metrics for measuring the RACs accomplishments. This effort incorporated the use of logic models to define and describe key RAC activities, outputs, and outcomes. Based on this detailed examination of RAC operations, potential metrics were identified associated with the various key sectors addressed by the RACs: policy makers; regulatory agencies; investor owned utilities; municipal and cooperative utilities; financiers; developers; and end users. The final product was reviewed by a panel of representatives from DOE, ORNL, RACs, and the private sector. The metrics developed through this effort focus on major RAC activities as well as on CHP installations and related outcomes. All eight RACs were contacted in August 2008 and asked to provide data for every year of Center operations for those metrics on which they kept records. In addition, data on CHP installations and related outcomes were obtained from an existing DOE-supported data base. The information provided on the individual RACs was summed to yield totals for all the Centers combined for each relevant item.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data Center Facility Monitoring with Physics Aware Approach

U.S. Department of Energy's National Renewable Energy Laboratory (NREL) hosts one of the world's most energy-efficient HPC data centers; this system uses component-level warm-water liquid cooling to efficiently remove heat from the data center and capture it for reuse in the building or rejection to the atmosphere. Given the complexity of this system, building data-driven tools for holistically monitoring and operating the entire data center is a priority for ensuring maximal efficiency and resiliency. In this advanced smart facility, over one million metrics are recorded per minute using state-of-the-art streaming data architecture and software to capture and process the state of the system in real time. Here we detail two efforts to effectively analyze, visualize, and interpret this large volume streaming data. We have developed a novel, flexible system for identifying and visualizing individual metric anomalies and component performance across the data center through automatic metadata extraction and physically-motivated visualization for quick interpretation. Additionally, to directly connect system maintenance to data stream processing we explore a physics informed multi-metric drift and anomaly detection application to detect scale-build up in heat exchangers.

anomaly detection↗

LANL HPC Data Center Monitoring (Summer 2022 Talk) [Slides]

HPC Monitoring is tasked with the understanding of everything that happens in the Data Center. They get to that understanding by: collecting logs and metrics, processing data, analyzing data, displaying information, and receiving alerts on events. Their ultimate (and probably unreachable) goal is a holistic view of the Data Center and an understanding of how everything is correlated.

97 MATHEMATICS AND COMPUTING↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Breaking adsorption-energy scaling limitations of electrocatalytic nitrate reduction on intermetallic CuPd nanocubes by machine-learned insights

The electrochemical nitrate reduction reaction (NO 3 RR) to ammonia is an essential step toward restoring the globally disrupted nitrogen cycle. In search of highly efficient electrocatalysts, tailoring catalytic sites with ligand and strain effects in random alloys is a common approach but remains limited due to the ubiquitous energy-scaling relations. With interpretable machine learning, we unravel a mechanism of breaking adsorption-energy scaling relations through the site-specific Pauli repulsion interactions of the metal d-states with adsorbate frontier orbitals. The non-scaling behavior can be realized on (100)-type sites of ordered B2 intermetallics, in which the orbital overlap between the hollow *N and subsurface metal atoms is significant while the bridge-bidentate *NO 3 is not directly affected. Among those intermetallics predicted, we synthesize monodisperse ordered B2 CuPd nanocubes that demonstrate high performance for NO 3 RR to ammonia with a Faradaic efficiency of 92.5% at –0.5 V RHE and a yield rate of 6.25 mol h –1 g –1 at –0.6 V RHE . This study provides machine-learned design rules besides the d-band center metrics, paving the path toward data-driven discovery of catalytic materials beyond linear scaling limitations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Artificial Intelligence for Data Center Operations (AIOps): Cooperative Research and Development (Final Report)

High performance computing data centers will increasingly need to rely on automation to keep pace with exascale growth in compute capability and to manage and optimize the data center environment and facility resources. Artificial intelligence and machine learning approaches provide the means to improve HPC data center operational efficiency, by learning historical trends and training models to operate on real-time data collected from both IT and facilities sources. NREL has developed methods of real-time collection, aggregation and streaming of these data in the ESIF HPC Data Center and has collected a significant dataset of relevant metrics across computer systems, racks, environmental, building and utility sources for research into various predictive analytics problems. HPE's Advanced Technology Group (ATG) is doing comprehensive research into exascale monitoring and management for High Performance Computing (HPC) systems (hereinafter HPE's Data Monitoring/ Management Technology). NREL and HPE will collaborate to add Artificial Intelligence (AI) to NREL's real-time data collection/ aggregation/ streaming system and HPE's Data Monitoring/ Management System, with the goal of improving the operational efficiency of NREL's Energy Systems Integration Facility (ESIF) HPC Data Center through data analytics on both historical and real-time data from IT systems and facilities operations. This collaboration will consist of efforts in Data Management, Data Analytics, and AI/ML Optimization for both manual and autonomous intervention in data center operations. This will be a multi-year, multi-staged effort with a goal towards building capabilities for an Advanced Smart Facility, and demonstration of these techniques in the NREL ESIF HPC Data Center.

97 MATHEMATICS AND COMPUTING↗

Real-time Data Center Energy Efficiency At Pacific Northwest National Laboratory

The escalating consumption of power in data centers worldwide has brought the issue of data center energy efficiency to the forefront. Data center owners and operators now regard detailed knowledge of the energy efficiencies of their data centers as a competitive advantage. With funding from the Department of Energy (NNSA), PNNL has undertaken an in-depth analysis of the real-time energy efficiency for its Energy Smart Data Center Test Bed(ESDC-TB), which is housed in the mixed-use EMSL. The analysis is centered around the real-time display of The Green Grid’s proposed DCiE metric. To calculate this metric, PNNL relies on a variety of sources of data. At the ESDC-TB level, the data center is instrumented to the 100% level (all power consumption, and water temperatures and flow rates are measured). Most of this data is monitored in real-time, but the exception to this is with the CRAHs, which rely on a one-time power consumption measurement for the blowers (these are single speed blowers, so a one-time measurement suffices.). Outside of the data center (EMSL facility level), PNNL relies on the following: • Real-time data from the entire chiller plant (five chillers), six chilled water pumps, and one of four cooling towers (blowers only). • One-time power measurements for a single fixed speed pump that is representative of each grouping of pumps (the other pumps are assumed to possess the same power consumption levels). • One-time power measurements for a single two-speed cooling tower blower. This same blower model is deployed in three of the four cooling towers, so is assumed to be representative for all these blowers. • One-time power measurements for a single fixed speed cooling tower pump. This same pump model is deployed in all four cooling towers, so is assumed to be representative for all these pumps. A software tool named FRED was developed by PNNL to acquire, reduce, display, and archive all the data acquired from the ESDC-TB and EMSL. FRED provides the ability to display various levels of real-time data starting at the ESDC-TB and EMSL levels, then to lower levels as desired. For example, for the ESDC-TB, graphical screens are provided at the data center level, the rack level, the server level, and even the component level. In the near-term, FRED will also display the real-time DCiE. One of the major challenges to doing this in a mixed-use facility has been to quantify the power consumption of each major mechanical or electrical subsystem that is attributable to the IT equipment housed within the ESDC-TB (i.e., NW-ICE). PNNL has tackled this issue for its five chiller plant, and the analysis is presented in the paper. The analysis for all the remaining mechanical and electrical subsystems is now underway and will be presented in future publications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TUE, a New Energy-Efficiency Metric Applied at ORNL’s Jaguar. In: ISC 2013: Supercomputing. Lecture Notes in Computer Science

The metric, Power Usage Effectiveness (PUE), has been successful in improving energy efficiency of data centers, but it is not perfect. One challenge is that PUE does not account for the power distribution and cooling losses inside IT equipment. This is particularly problematic in the HPC (high performance computing) space where system suppliers are moving cooling and power subsystems into or out of the cluster. This paper proposes two new metrics: ITUE (IT-power usage effectiveness), similar to PUE but “inside” the IT and TUE (total-power usage effectiveness), which combines the two for a total efficiency picture. We conclude with a demonstration of the method, and a case study of measurements at ORNL’s Jaguar system. TUE provides a ratio of total energy, (internal and external support energy uses) and the specific energy used in the HPC. TUE can also be a means for comparing HPC site to HPC site.

data center↗

Figures of merit for production HPC

This report summarizes a set of figures of merit of interest in monitoring the hardware and hardware usage in a Sandia high performance computing (HPC) center. These figures are computable from high frequency monitoring data and other non-metric data and may aid administrators and customer support personnel in their decision processes. The figures are derived from interviews of the HPC center staff. The figures are in many cases simplistic data reductions, but they are our initial targets in creating dashboards that turn voluminous monitoring data into actionable information. Because simplistic reductions may obscure as well as reveal the situation under study, we also document the necessary 'drill-down' and %60exploration' views needed to make the data better understood quickly. These figures of merit may be compared to dashboarding tools documented by other HPC centers.

97 MATHEMATICS AND COMPUTING↗

DOE BSSD Performance Management Metrics Report Q2

The vision of the National Microbiome Data Collaborative (NMDC) centers on the concept of connecting data, people, and ideas to advance microbiome innovation and discovery. Building data infrastructure, while key to NMDC’s ability to execute on our vision, can only go so far in creating scientific impact. By fostering strong community partnerships and developing a set of robust community outreach and training programs, we are able to turn our products – the Submission Portal, NMDC EDGE, and the Data Portal – into tools that empower the scientific community. Our multi-pronged community building approach spans individual researchers, research teams, consortia and scientific societies, and institutions and federal agencies. To foster a collaborative and inclusive community-centered environment, we have identified three strategic objectives to promote an inclusive and connected community: (1) recognize and support the diverse research needs and perspectives of the microbiome research community; (2) promote best practices across the microbiome community, from researchers to funders, through community-driven practices (FAIR, CARE, and TRUST); and (3) build a microbiome ecosystem that enables scientific discovery and innovation across stakeholders. These strategic objectives allow our team to focus on impact across a diverse range of activities, from launching the American Society for Microbiology (ASM) Microbiome Data Prize to supporting the Ambassador and Champions programs fostering learning and building a collaborative network. We broadly communicate our work through social media (X/Twitter, LinkedIn, and Instagram), The Microbiome Standard (our quarterly newsletter), and Annual Reports. All our work is underpinned by a strong commitment to diversity, equity, and inclusion as articulated in our Action Plan that tracks progress towards key metrics. A core component of our engagement strategy is user research. User research ensures the Submission Portal, NMDC EDGE, Data Portal, and the new Field Notes mobile app are designed with and for the scientific community. Our user research efforts consist of asking researchers exploratory questions to collect information on researcher priorities, methodologies, and perceptions to ensure that we are aware of the current state of microbiome research. Our usability testing provides researchers with prototypes or test environments of the NMDC products, and we capture valuable information on how users interact with the products to make improvements. Given the diverse nature of microbiome work, we acknowledge that we are not aware of all pressing data challenges and thus rely on the research community to help us identify the most important issues to prioritize. To date, we have conducted 24 interviews and one beta-testing call with 10 participants across all NMDC products, which have generated 321 insights and 120 action items. Herein, we describe the ways we engage with the microbiome research community to advance the NMDC mission.

59 BASIC BIOLOGICAL SCIENCES↗