Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data center air management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Best Practices Guide for Energy-Efficient Data Center Design

This guide provides an overview of best practices for energy-efficient data center design which spans the categories of information technology (IT) systems and their environmental conditions, data center air management, cooling and electrical systems, and heat recovery. IT system energy efficiency and environmental conditions are presented first because measures taken in these areas have a cascading effect of secondary energy savings for the mechanical and electrical systems. This guide concludes with a section on metrics and benchmarking values by which a data center and its systems energy efficiency can be evaluated. No design guide can offer “the most energy-efficient” data center design but the guidelines that follow offer suggestions that provide efficiency benefits for a wide variety of data center scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Foreword: Special Section on Multiphysics Aspects of Power Electronics Packaging - Power Die, Power Module, and Converter Level - Part 1

Power electronics are increasingly being used to condition electricity for a wide array of applications, such as transportation (on land, air, and water), data centers, radio frequency, directed energy, wind, solar, and grid-tied applications. To increase power density, performance, efficiency, and reliability and reduce cost, innovations and developments are needed in the multiphysics packaging of power electronics at a die, module, and converter level. This includes fundamental research and development related to emerging high-voltage, high-temperature, and high-switching-frequency power electronics; packaging materials; thermal materials and interfaces; fluid-based thermal management technologies; reliability; condition monitoring; and prognostics. To address these important aspects, this Special Section on Multiphysics Aspects of Power Electronics Packaging includes several articles to be published in two parts. More details are given below on the articles included in the first part.

condition monitoring↗

Foreword: Special Section on Multiphysics Aspects of Power Electronics Packaging—Power Die, Power Module, and Converter Level: Part 2

Power electronics are increasingly being used to condition electricity for a wide array of applications, such as transportation (on land, air, and water), data centers, radio frequency, directed energy, wind, solar, and grid-tied applications. Here, to increase power density, performance, efficiency, and reliability-as well as to reduce cost-innovations and developments are needed in the multiphysics packaging of power electronics at a die, module, and converter level. This includes fundamental R&D related to emerging high-voltage, high-temperature, and high-switching-frequency power electronics, packaging materials, thermal materials and interfaces, fluid-based thermal management technologies, reliability, condition monitoring, and prognostics. Latest developments in this area are published as a Special Section on Multiphysics Aspects of Power Electronics Packaging. The first part was published in the May 2024 issue of the IEEE Transactions on Components, Packaging and Manufacturing Technology (Volume 14, Issue 5). The second part of that Special Section is being published in this issue. A brief summary of the papers included in the second part are given below.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AmeriFlux FLUXNET-1F US-GL1 Stannard Rock

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-GL1 Stannard Rock. This is the FLUXNET version of the carbon flux data for the site US-GL1 Stannard Rock produced by applying the standard ONEFlux (1F) software. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris [Environment and Climate Change Cana↗

Coastal-Urban-Rural Atmospheric Gradient Experiment (CoURAGE) Science Plan

Understanding the mechanisms governing the urban atmospheric environment is critical for informing urban populations regarding the impacts of climate change and associated mitigation and adaptation measures. Earth system (climate and weather) models have not yet been adapted to provide accurate predictions of climate and weather variability within cities, nor do they provide well-tested representations of the impacts of urban systems on the atmospheric environment. These limitations are largely due to limited field data available for testing and development of these models. We will deploy the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s first Mobile Facility (AMF1) to the mid-Atlantic region surrounding the city of Baltimore for the Coast-Urban-Rural Atmospheric Gradient Experiment (CoURAGE). This deployment will create a four-node regional atmospheric observatory network including Baltimore and its three primary surrounding environments – rural, urban, and bay. CoURAGE investigators will study the interactions among the Earth’s surface, the atmospheric boundary layer, aerosols and atmospheric composition, clouds, radiation, and precipitation at each site, and examine how the spatial gradients across the region interact to create the climate conditions in Baltimore. This study will determine the degree to which Baltimore’s atmospheric environment depends on interactive feedbacks in the atmospheric system and the degree to which conditions in Baltimore depend on the surrounding environment. Some topics of interest include how urban land management exacerbates heat waves, the impact of regional mesoscale winds (nocturnal jet, bay breeze) on urban air pollution and cloud cover, and the impact of the urban heat island and aerosol production on heavy precipitation events. Understanding this integrated coast-urban-rural system quantitatively and with good accuracy and precision is critical to informing climate adaptation and mitigation efforts in the city of Baltimore. The understanding gained should be applicable to many similar coastal, mid-latitude urban centers. Another important objective of CoURAGE is to improve the representation of the climate of coastal cities in Earth systems models (ESMs). CoURAGE investigators will use the observations to test current ESMs, identify weaknesses and work towards improved simulations of this complex environment. The ARM core facility will be deployed in the city of Baltimore, complementing the Baltimore Social-Environmental Collaborative (BSEC), a DOE urban integrated field laboratory (UIFL). Ancillary sites will be deployed to rural Maryland northwest of Baltimore, and to the southern end of Kent Island within Chesapeake Bay. The fourth node will be a long-term atmospheric observatory operated in Beltsville, Maryland by Howard University and the Maryland Department of the Environment. Measurements will be conducted for one year, starting in December of 2024. There will be two intensive operational periods (IOPs), one in summer and one in winter, when the ancillary sites will be enhanced with additional balloon launches, tethered balloon system (TBS) operation, and added atmospheric composition measurements.

54 ENVIRONMENTAL SCIENCES↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

An evaluation of air quality in major urban areas of India

Rapid economic growth and burgeoning population have contributed to enhanced levels of PM 2.5 concentrations in urban regions of India. Evaluation of ambient air quality facilitates the assessment of effectiveness of emission control measures and early identification of new sources. This study provides a comprehensive statistical analysis of PM 2.5 concentrations in key urban areas across India, including Delhi, Kolkata, Mumbai, Chennai, Hyderabad, and several regional centers. Data from 2017 to 2023 was analyzed using trend analysis, cluster analysis, principal component analysis, and geostatistical interpolation to understand spatiotemporal variations and sources. The analysis reveals significant differences in spatial distribution of PM 2.5 concentrations with high annual averages in urban regions in Indo-Gangetic plain (82–123 μg m −3 ) and relatively lower concentrations (29–46 μg m −3 ) in southern urban areas of Kerala, Tamil Nadu and Andhra Pradesh. Delhi state had the highest 24-averaged PM 2.5 concentrations (112 μg m −3 ) followed by urban regions in Uttar Pradesh, Bihar and West Bengal (94 μg m −3 ). Trend analysis from 2017 to 2023 revealed an overall 2.5% decline in site-wide PM2.5 concentrations, with the exception of Ludhiana, which exhibited a consistent annual increase of 10%. Principal component analysis (PCA) attributes 30% of the variance to wintertime emissions, 13% to biomass burning, and 18% to the regional haze in the northern Indo-Gangetic Plain. Different analyses clearly demonstrates the contribution of biomass burning to pollution in Delhi and surrounding cities. Transboundary pollution to Kolkata is likely from the highly polluted region in Indo-Gangetic Plain. Coastal cities of Mumbai and Chennai has relatively lower pollution attributed to the influence of sea breeze dilution, with mostly local contribution and some potential transport from upwind industry clusters. Hyderabad also has local contribution due to high density of vehicular traffic and local small industries. This study shows that mitigation efforts targeting clusters of regions should be undertaken to curb the high PM2.5 pollution. Policy measures should be implemented both at local and the intra-state level to address shared sources and transport of pollution.

Hysplitbacktrajectories↗

Machine learning enables reconstruction of past fire regimes from charcoal-derived fire intensity and fuel composition

Background Fire is a foundational ecological process that shapes ecosystem structure, diversity, and resilience. Quantifying paleofire regime attributes such as frequency, severity, and intensity is essential for understanding the historical range of variability in fire behavior and its ecological effects. While frequency and severity are often reconstructed in paleofire studies, quantitative reconstructions of fire intensity remain limited. Recent work has shown that maximum pyrolysis temperature—a proxy for fire intensity—and plant species type can be inferred from charcoal using transmission Fourier-transform infrared (FTIR) spectroscopy. However, the sample preparation for transmission FTIR is destructive and time-consuming, limiting application and reuse of materials for other analyses. We evaluated reflectance FTIR spectroscopy as a non-destructive alternative for reconstructing combustion temperature and plant species from laboratory-generated charcoal. We also examined the influence of contrasting airflow environments (ambient air versus nitrogen-rich) on pyrolysis temperature and plant species reconstruction prediction accuracies and compared predictive performance between a novel, neural network–based deep learning model with the traditional modern analogue technique (MAT) using k-nearest neighbor functions. As proof of concept, we apply our enhanced methodology to ancient charcoal to demonstrate applicability at improving long-term fire regime reconstructions and the ability to link paleofire records with contemporary fire ecology. Results Our analysis shows that transmission and reflectance FTIR spectra yield comparable spectral profiles. However, sample preparation for reflectance FTIR is minimal and non-destructive, unlike transmission FTIR which is destructive. We demonstrate that oxygen environments improved reconstruction accuracy relative to nitrogen-rich conditions. Finally, our deep learning neural network (DL) achieved testing accuracies of 98.7% for temperature and 96.2% for species identification, outperforming MAT’s k-NN approach (89.8% and 65.9%, respectively). A Shapley importance analysis identified 5 key spectral regions that greatly influenced the model’s temperature or species categorization. When applied to ancient charcoal, our results show historic fires from the most recent past primarily burned at low intensities (400–500 °C), reflective of natural fire regimes in ponderosa pine forests. Our results corroborate charcoal morphology data that suggests all ancient charcoal originated from burned woody plant types. Conclusions By combining reflectance FTIR spectroscopy with a deep learning approach, we provide the first accuracies high enough to confidently identify both species and temperature from laboratory-produced charcoal, improving quantitative reconstructions of fire intensity and fuel composition from paleofire records. This opens a wide range of research into the link between fire and larger drivers (i.e., climate or human) and greater ecological understanding of fire regimes beyond that of burn scars or recent observations. These methodological improvements have direct relevance for fire management by improving interpretation of historical fire behavior, informing fuel–fire relationships, and providing a scalable analytical framework applicable to both long-term ecological studies and contemporary fire science.

54 ENVIRONMENTAL SCIENCES↗

Data for "Land-based Resources for Engineered Carbon Dioxide Removal in the United States Exceed the Expected Needs"

Gigatonne-scale atmospheric carbon dioxide removal (CDR), alongside deep emission cuts, is critical to stabilizing the climate. However, some of the most scalable CDR technologies are also the most land intensive. Here, we examine whether adequate land resources exist in the contiguous United States to meet CDR targets when prioritizing grid emissions reduction, food production, and the protection of sensitive ecosystems. We focus on biomass carbon removal and storage (BiCRS) and direct air capture and storage (DACS) and show that suitable lands exceed the expected needs: 37.6 million hectares of land are available for BiCRS, resulting in 0.26 GtCO2 of CDR/year, and 34 million hectares are suitable for wind- and solar-powered DACS, resulting in 4.8 GtCO2 of CDR/year if facilities are co-located with geologic CO2 storage. We identify biomass and energy supply hotspots to meet CDR targets while ensuring land protection and minimizing land competition.

carbon↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Data for The Value of Reversible Carbon Storage in a Zero-Emissions World

Atmospheric carbon dioxide removal (CDR) is required to stabilize global temperature. CDR can be achieved via ecosystem-based approaches that are cost-effective but reversible (e.g., soil and forest management) or by more durable but expensive approaches (e.g., direct air capture coupled with geologic storage). Here, we examine trade-offs between these approaches, focusing on timing, climate impacts, and cost. We simulated reversible carbon accrual for a range of CDR contract structures using a general minimalist model of ecosystem carbon cycling, and parameterized it to simulate US agricultural soil management─specifically cover cropping─as a case study. We then quantified the resulting impact on atmospheric carbon and global temperature using a climate model emulator. We find that maintaining a patchwork of reversible CDR projects by replacing lapsed projects with new projects can reduce warming by 22–195 μ°C in 2100 and that the magnitude of this cooling effect depends on how effectively the patchwork is maintained. Long-term maintenance of reversible CDR projects requires institutional stability that cannot be guaranteed over multiple decades. Consequently, effective CDR ultimately requires replacing reversible projects with durable projects. To address this problem, we modeled the cost of replacing reversible agricultural soil CDR with geologic CDR. We found that using reversible CDR as a bridge to durable CDR is potentially more cost-effective as a global cooling strategy (0.20–0.81 billion USD per μ°C avoided) than perpetual maintenance of reversible CDR (0.32–1.31 billion USD per μ°C avoided) or an immediate transition to durable CDR (1.37–2.19 billion USD per μ°C avoided). However, we emphasize that institutional commitments to maintain reversible CDR projects cannot be guaranteed. Reliance on reversible CDR as a bridge to durable CDR therefore carries an unknown amount of risk and will only function if efforts to maintain reversible CDR are robust.

Carbon↗