Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cyclotron resonance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nonlinear electron acceleration by oblique whistler waves: Landau resonance vs. cyclotron resonance

This paper is devoted to the study of the nonlinear interaction of relativistic electrons and high amplitude strongly oblique whistler waves in the Earth's radiation belts. We consider electron trapping into Landau and fundamental cyclotron resonances in a simplified model of dipolar magnetic field. Trapping into the Landau resonance corresponds to a decrease of electron equatorial pitch-angles, while trapping into the first cyclotron resonance increases electron equatorial pitch-angles. For 100 keV electrons, the energy gained due to trapping is similar for both resonances. For electrons with smaller energy, acceleration is more effective when considering the Landau resonance. Moreover, trapping into the Landau resonance is accessible for a wider range of initial pitch-angles and initial energies in comparison with the fundamental resonance. Thus, we can conclude that for intense and strongly oblique waves propagating in the quasi-electrostatic mode, the Landau resonance is generally more important than the fundamental one.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The development of a room temperature electron cyclotron resonance ion source (Lanzhou electron cyclotron resonance ion source No. 4) with evaporative cooling technology at Institute of Modern Physics

LECR4 (Lanzhou electron cyclotron resonance ion source No. 4) has been successfully constructed at IMP and has also been connected with the Low Energy Beam Transport (LEBT) and Radio Frequency Quadrupole (RFQ) systems. These source magnet coils are cooled through evaporative cooling technology, which is the first attempt with an ECR ion source in the world. The maximum mirror field is 2.5 T (with iron plug) and the effective plasma chamber volume is 1.2 l. It was designed to be operated at 18 GHz and aimed to produce intense multiple charge state heavy ion beams for the linear injector project SSC-Linac at IMP. In February 2014, the first analyzed beam at 18 GHz was extracted. During about three months’ commissioning, some outstanding results have been achieved, such as 1.97 emA of O{sup 6+}, 1.7 emA of Ar{sup 8+}, 1.07 emA of Ar{sup 9+}, and 118 euA of Bi{sup 28+}. The source has also successfully delivered O{sup 5+} and Ar{sup 8+} ion beams for RFQ commissioning in April 2014. This paper will give a brief overview of the design of LECR4. Then, the latest results of this source at 18 GHz will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface-Induced Dissociation of Protein Complexes in a Hybrid Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

Mass spectrometry continues to develop as a valuable tool in the analysis of proteins and protein complexes. In protein complex mass spectrometry studies, surface-induced dissociation (SID) has been successfully applied in quadrupole time-of-flight (Q-TOF) instruments. SID provides structural information on non-covalent protein complexes that is complementary to other techniques. However, the mass resolution of Q-TOF instruments can limit the information that can be obtained for protein complexes by SID. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) provides ultrahigh resolution and ultrahigh mass accuracy measurements. In this study, an SID device was designed and successfully installed in a hybrid FT-ICR instrument in place of the standard gas collision cell. The SID-FT-ICR platform has been tested with several protein complex systems (homooligomers, a heterooligomer, and a protein-ligand complex, ranging from 53 kDa to 85 kDa), and the results are consistent with data previously acquired on Q-TOF platforms, matching predictions from known protein interface information. SID fragments with the same m/z but different charge states are well-resolved based on distinct spacing between adjacent isotope peaks, and the addition of metal cations and ligands can also be isotopically resolved with the ultrahigh mass resolution available in FT-ICR.

Environmental Molecular Sciences Laboratory↗

Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency

The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω{sub c}. In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω{sub c} quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω{sub +}), whereas the ω{sub c} and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω{sub +} quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω{sub c} frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω{sub +} frequencies can be reduced to negligible levels relative to peaks close to ω{sub c} frequencies. Due to reduced errors with which the ω{sub c} quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω{sub +} frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced production of electron cyclotron resonance plasma by exciting selective microwave mode on a large-bore electron cyclotron resonance ion source with permanent magnet

We are constructing a tandem type ECRIS. The first stage is large-bore with cylindrically comb-shaped magnet. We optimize the ion beam current and ion saturation current by a mobile plate tuner. They change by the position of the plate tuner for 2.45 GHz, 11–13 GHz, and multi-frequencies. The peak positions of them are close to the position where the microwave mode forms standing wave between the plate tuner and the extractor. The absorbed powers are estimated for each mode. We show a new guiding principle, which the number of efficient microwave mode should be selected to fit to that of multipole of the comb-shaped magnets. We obtained the excitation of the selective modes using new mobile plate tuner to enhance ECR efficiency.

43 PARTICLE ACCELERATORS↗

Novel Strategy To Analyze Fourier Transform Ion Cyclotron Resonance Mass Spectrometry Data of Biomass Pyrolysis Oil for Oligomeric Structure Assignment

Among the most prominent challenges for the analysis of biomass pyrolysis products is the characterization of the abundant oligomer fraction of bio-oil. This fraction is principally made up of pyrolytic lignins and dehydrated, highly modified sugar oligomers, called humins, in liquid phase. An emerging technique for analysis of this oligomer fraction is high-resolution Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS), which allows for accurate determination of C x H y O z formulae for detected oligomers. Additionally, using simple dehydration and fragmentation reaction schemes, similar formulae can be developed from cellulose-, hemicellulose- and lignin-derived oligomers, which are primary depolymerization products. In this paper, FT-ICR MS analysis is coupled with combinatoric dehydration and fragmentation modeling in order to match experimentally detected bio-oil oligomers with hypothetical pathways for their formation during pyrolysis. In this way, we present a novel strategy by which oligomeric structures can be proposed for bio-oils. Using this approach, it becomes possible to advance the understanding of both the molecular structures comprising the bio-oil oligomer fraction and the pathways by which these structures form during biomass pyrolysis reactions.

09 BIOMASS FUELS↗

Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry as a Platform for Characterizing Multimeric Membrane Protein Complexes

Membrane protein characterization is consistently hampered by challenges with expression, purification, and solubilization. Among several biophysical techniques employed for their characterization, native-mass spectrometry (MS) has emerged as a powerful tool for the analysis of membrane proteins and complexes. Here, two MS platforms, the FT-ICR and Q-ToF, have been explored to analyze the homotetrameric water channel protein, AquaporinZ (AqpZ), under non-denaturing conditions. This 97 kDa membrane protein complex can be readily liberated from the octylglucoside (OG) detergent micelle under a range of instrument conditions on both MS platforms. Increasing the applied collision energy of the FT-ICR collision cell yielded varying degrees of tetramer (97 kDa) liberation from the OG micelles, as well as dissociation into the trimeric (72 kDa) and monomeric (24 kDa) substituents. Tandem-MS on the Q-ToF yielded higher intensity tetramer signal and, depending on the m/z region selected, the observed monomer signal varied in intensity. Precursor ion selection of an m/z range above the expected protein signal distribution, followed by mild collisional activation, is able to efficiently liberate AqpZ with a high S/N ratio. The tetrameric charge state distribution obtained on both instruments demonstrated superpositioning of multiple proteoforms due to varying degrees of N-terminal formylation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiment study of an electron cyclotron resonant ion source based on a tapered resonance cavity

Electron cyclotron resonant plasma is one type of magnetised plasma generated by continuous microwave energy. It has the property of high degree of ionization and large volume at low gas pressure, which makes it useful for space propulsion and material processing. This article presents the experiment study of the plasma properties and ion beam extraction from an electron cyclotron resonant ion source based on a tapered resonance cavity. Optical emission spectroscopy based on a simple collisional radiation model was used for plasma diagnosis. Experiment results show that, at microwave power setting ranging from 7.06 to 17.40 W and mass flow rate ranging from 1 to 10 sccm, argon gas can be ionized. Ion beam of 109.1 mA from the ion source can be extracted at microwave power of 30 W, mass flow rate of 10 sccm, and accel voltage of 800 V. The diagnosed plasma temperature and density are 2.4–5.2 eV and 2 × 10{sup 16}–4.8 × 10{sup 17} m{sup −3}, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vacuum Pyrolysis of Hybrid Poplar Milled Wood Lignin with Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry Analysis of Feedstock and Products for the Elucidation of Reaction Mechanisms

The pyrolysis of lignocellulosic materials is a promising technique to produce fuels and chemicals. It is well known that the most abundant products of lignin pyrolysis are oligomeric molecules, known as pyrolytic lignin (PL). The chemical composition of PL has been extensively studied; however, there is still an important debate whether these oligomers are produced directly from the lignin or from the recombination of monomeric pyrolytic products. Existing theories are unable to describe the effect of vacuum on the distribution of pyrolysis products. Hybrid poplar milled wood lignin (MWL) was initially isolated and thoroughly characterized by Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS). Chemical formulas were assigned to each oligomeric compound detected. The MWL was also subjected to vacuum pyrolysis in a modified pyroprobe at 250, 750, and 1000 mbar (absolute pressure), and the resulting liquid products were analyzed by FT-ICR MS. A new strategy to assign structural representations to the oligomeric PL products is proposed, based on the plausible pyrolysis reaction mechanisms of depolymerization/fragmentation applied to original MWL oligomer formulas. Our results support the hypothesis that PL is formed from the removal of moieties from primary lignin pyrolysis products with between three and five aromatic rings. This depolymerization/fragmentation allows the oligomers to reduce their molecular weights to the point where they can be removed from the reaction zone by direct vaporization. Furthermore, this phenomenon highlights the importance of pressure on removal mechanisms and their impact on the molecular weight of the resulting products from lignin pyrolysis.

09 BIOMASS FUELS↗

Studies on a Q/A selector for the SECRAL electron cyclotron resonance ion source

Electron cyclotron resonance ion sources are widely used in heavy ion accelerators in the world because they are capable of producing high current beams of highly charged ions. However, the design of the Q/A selector system for these devices is challenging, because it must have a sufficient ion resolution while controlling the beam emittance growth. Moreover, this system has to be matched for a wide range of ion beam species with different intensities. In this paper, research on the Q/A selector system at the SECRAL (Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou) platform both in experiment and simulation is presented. Based on this study, a new Q/A selector system has been designed for SECRAL II. The features of the new design including beam simulations are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct determination of the electron effective mass of GaAsN by terahertz cyclotron resonance spectroscopy

We use cyclotron resonance THz-spectroscopy in pulsed magnetic fields up to 63 T to measure the electron effective mass in Si-doped GaAsN semiconductor alloys with nitrogen content up to 0.2%. This technique directly probes the transport properties of the N-modified conduction band, particularly the electron effective mass, which has been discussed controversially in the experimental and theoretical literature. We report a slight increase of the electron effective mass and nonparabolicity with N-content for different photon energies in agreement with the two-level band anticrossing model calculations. Furthermore, we show a pronounced electron mobility drop with increasing N-content.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the electrically detected cyclotron resonance of holes in silicon nanostructures

The cyclotron resonance in semiconductor nanostructures is electrically detected for the first time without an external cavity, a source, and a detector of microwave radiation. An ultranarrow p-Si quantum well on an n-Si (100) surface confined by superconducting heavily boron-doped {delta}-shaped barriers is used as the object of investigation and provides microwave generation within the framework of the nonstationary Josephson effect. The cyclotron resonance is detected upon the presence of a microcavity, which is incorporated into the quantum-well plane, by measuring the longitudinal magnetoresistance under conditions of stabilization of the source-drain current. The cyclotron-resonance spectra and their angular dependences measured in a low magnetic field identify small values of the effective mass of light and heavy holes in various 2D subbands due to the presence of edge channels with a high mobility of carriers.

36 MATERIALS SCIENCE↗