Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cyber physical simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A real-time multiphysics model of a pressurized solid oxide electrolysis cell (SOEC) for cyber-physical simulation

Solid oxide electrolysis cells (SOEC) can play important roles in integrated energy systems (IES) as the hydrogen production hub and the resilience energy hub. When tied to a microgrid with high renewable penetration, the SOEC is subjected to rapid load transitions in response to the intermittent renewable generations that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). The cyber-physical simulation approach can derisk operability research but requires a real-time dynamic SOEC model. In the present work, a real-time multiphysics model for pressurized SOEC is developed and validated in the pressure range from 1.4 to 8bar. Further, the accuracy of the single repeating unit (SRU) assumption in SOEC stack simulation is quantified. A guidance of more than 45 cells in one SOEC stack is recommended to safely apply the SRU assumption. Modeling results suggest that at a given current density, more power is consumed by SOEC at elevated operating pressures. The anode air and cathode stream have major impacts on thermal management, highlighting the potential benefit of integrating SOEC with other thermal processes in IES. To achieve high hydrogen production efficiency, the SOEC could operate at the maximum endothermic point to maximize the use of thermal energy. The real-time execution of the developed SOEC model is also demonstrated, which only takes 0.1% of the fixed time step of 5ms. The developed model establishes the basis for cyber-physical simulation of SOEC hybrid systems.

25 ENERGY STORAGE↗

Cyber-Physical Simulation of the Cold Startup of Solid Oxide Fuel Cell – Gas Turbine (SOFC-GT) Hybrid Systems

This work introduces experimental studies for the cold startup process (CPS) of the SOFC-GT hybrid system using the cyber-physical simulation approach. The physical gas turbine is coupled with a cyber-physical SOFC stack, which is represented using the integration of a real time dynamic SOFC model with physical components (e.g., pressure chamber, natural gas burner, etc.). Different ramp rates of the turbine speed were tested out during the startup processes. Bypass valves were also used to manipulate the airflow during SOFC-GT hybrid system start-up process. Different ramp rates enable the rapid start-up of the turbine to avoid surge and stall, meanwhile enable acceptable warm rate of the fuel cell stack without damaging the cell material. CPS can enable dynamic characterizations of highly integrated systems at lower cost.

Zhou, Nana↗

Cyber-Physical Simulation of an Innovative Solid Oxide Electrolysis Cell - Gas Turbine (SOEC-GT) Hybrid Energy System

To produce green hydrogen at scale and at low cost, the solid oxide electrolysis cell (SOEC) systems would be tied to renewable power sources (mainly solar and wind), leveraging zero-carbon electricity at low prices and even nearly free during overgeneration scenarios. However, due to the intermittency of renewable power generation, the SOEC system is subjected to rapid load transitions that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). This can result in fast degradation and thus greatly reduce the SOEC’s lifetime. Our team at the National Energy Technology Laboratory has demonstrated that the anode air flow can have a crucial role in SOEC thermal management. Typically, a higher air flow rate can help to mitigate the local temperature gradient distortion during rapid load transitions. To move a large amount of air, the gas turbine (GT; i.e., compressor-turbine-generator set) has been regarded as the most mature and efficient technology. In this presentation, we show the configuration and preliminary results of an innovative SOEC-GT hybrid energy system in a cyber-physical simulation (CPS) approach.

Zhang, Biao↗

NUMERICAL MODELING OF A SOLID OXIDE FUEL CELL FOR USE IN REAL-TIME SIMULATION AND CYBER-PHYSICAL SYSTEMS

Cyber-physical systems provide a mechanism with which to investigate the physical phenomena and behavior of traditionally cost-prohibitive or otherwise fragile equipment. For the National Energy Technology Laboratory (NETL), this approach resulted in the Hybrid Performance (Hyper) facility which features a gas turbine-SOFC hybrid cycle utilizing real turbomachinery and a simulated SOFC stack. This allows for the investigation of combined cycle performance and control strategies, in an exhaustive manner, both without fear of destroying delicate state-of-the-art fuel cells, and with the full accuracy of real-world turbomachinery. Issues arose between the transient response of the SOFC model being limited to a sample time of 80 milliseconds, due to the calculation time of the SOFC model taking on average 40 milliseconds to calculate for a given timestep with spikes in calculation time reaching the 80 millisecond threshold. In order to be able to match the speed of transients from the turbomachinery and likewise better discern transient behavior, it was determined that the SOFC model must be optimized to operate at a sample time of 5 milliseconds. Therefore, it is necessary to optimize the SOFC model in order to decrease the calculation time from around 40 milliseconds, down to at the most 5 milliseconds. To do this, both the electrochemical algorithm and the thermal algorithm used to simulate the physical behavior of the SOFC are investigated to determine where improvements can be made. To this end the rootfinding numerical recipes of the electrochemical algorithm are investigated as the complex electrochemistry requires a highly iterative nested dual convergence loop to resolve the voltage-current relationship, and likewise the temporal discretization of the thermal algorithm is modified for the sake of higher accuracy and stability. Ultimately the new electrochemical algorithm featuring higher order rootfinding schemes proves to be efficient enough to reach the sub 5 millisecond target, signifying an order of magnitude reduction in calculation time, and when coupled with the new temporal discretization similar calculation time characteristics show that a fully implicit, higher order temporal discretization can also successfully be used if desired. Ultimately this result means that the cyber-physical simulation system can operate at higher sample rates, and resolve transient events at significantly higher resolution and fidelity.

Arias, Jesus↗

Development of HELICS-Based High-Performance Cyber-Physical Co-Simulation Framework for Distributed Energy Resources Applications

The rapid growth of distributed energy resources (DERs) has prompted increasing interest in the monitoring and control of DERs through hybrid smart grid communications resulting in the typical smart grid cyber-physical system. To fully understand the interdependency between them, we propose to integrate the Network Simulator 3 (NS3) into the High Engine for Large-Scale Infrastructure Co-Simulation (HELICS), a new open-source, cyber-physical-energy co-simulation platform. This paper aims to the development and case study of the HELICS-based high performance distribution-communication co-simulation framework for the DER coordination. The novel co-simulation framework for the NS3 integrating into the HELICS is developed. The DER monitoring application about hybrid smart grid communication network design is simulated and validated on this proposed HELICS-based cyber-physical co-simulation platform.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

A Cryptographic Method for Defense Against MiTM Cyber Attack in the Electricity Grid Supply Chain

Critical infrastructures such as the electricity grid can be severely impacted by cyber-attacks on its supply chain. Hence, having a robust cybersecurity infrastructure and management system for the electricity grid is a high priority. This paper proposes a cyber-security protocol for defense against man-in-the-middle (MiTM) attacks to the supply chain, which uses encryption and cryptographic multi-party authentication. A cyber-physical simulator is utilized to simulate the power system, control system, and security layers. The correctness of the attack modeling and the cryptographic security protocol against this MiTM attack is demonstrated in four different attack scenarios.

Paul, Shuva↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of DER Communication Delay in AGC: Cyber-Physical Dynamic Co-Simulation: Preprint

Distributed energy resource (DER) frequency regulations are promising technologies for future grid operation. Unlike conventional generators, DERs might require open communication networks to exchange signals with control centers, possibly through DER aggregators; therefore, the impacts of the communication variations including the latency on the system frequency stability need to be investigated. This paper develops a cyber-physical dynamic simulation (CPDS) model based on the Hierarchical Engine for Large-Scale Co-Simulation (HELICS) to evaluate the impact of the communication variations, such as delays in DER frequency regulations. The feasible delay range can be obtained under different AGC parameter settings. The results show that the risk of instability generally increases with the communication delay and that the difference of AGC provided from DER and conventional generation units should be recognized when designing frequency regulation controllers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of Open Communication Networks on Load Frequency Control with Plug-In Electric Vehicles by Cyber-Physical Dynamic Co-Simulation

With the increasing electrification of the transportation sector to achieve the carbon neutrality objective, despite the challenges of charging electric vehicles (EV), there are also opportunities through smart charging EVs to improve system frequency stability; however, EV control technologies might require nontraditional communication support. This paper investigates the impacts of communication variations of EV on power system load frequency control through a cyber-physical dynamic system (CPDS) co-simulation. Here, the CPDS is built upon our previously developed transmission-and-distribution dynamic co-simulation model with the added communication variation functions (i.e., delay and packet loss). The case studies consider multiple communication variation scenarios when the system experiences an N-1 generation trip contingency. The scenarios include communication delays and packet loss using both homogeneous and heterogeneous assumptions. The outcomes of this work can help improve EV frequency regulation services and provide robust and effective tests for different load frequency control algorithms of the future power systems.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Cyber-Physical Events Emulation Based Transmission and Distribution Co-Simulation for Situation Awareness and Grid Anomaly (SAGA) Detection: Preprint

Energy management of transmission and distribution networks is becoming more challenged with the accelerated increasing of distributed energy resources (DERs) such as distributed photovoltaic (PV) generation and distributed energy storage. To better analyze the impacts of DERs on both transmission and distribution systems, a comprehensive transmission and distribution co-simulation platform should be developed. Furthermore, with DERs more actively participated in system operation such as providing real time grid services, their cyber vulnerability should be better understood to maintain system reliability. This paper discussed a cyber-physical events emulation based transmission & distribution co-simulation platform to perform different cyber events emulation and analyze the impacts of cyber physical events happened in distribution system on the T&D system operation. The case studies with both a transmission network and a synthetic distribution network data validate that the proposed T&D co-simulation platform can perform comprehensive cyber physical events emulation. Therefore, with extensive simulation using the proposed model, the system operator can accumulate adequate training data for the system situation awareness and grid anomaly detection purpose.

31 CESER - Office of Cybersecurity, Energy Securit↗

Demonstrating the Transient System Impact of Cyber-Physical Events Through Scalable Transmission and Distribution (T&D) Co-Simulation

Modern power systems become more vulnerable to cyber threats due to their growing interconnectivity, interdependence, and complexity. Widespread deployment of distributed energy resources (DERs) further expands the threat landscape to the grid edge, where fewer cybersecurity protections exist. In this article, a systematic cyber-physical events demonstration, enabled by an integrated transmission, distribution, and communication co-simulation framework, is performed. It analyzes cyber risks to power grid under DER-enabled automatic generation control from different angles. Unlike existing works, the simulation captures millisecond-to-minutes frequency and voltage transient dynamics at a cross-region system scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Open Communication Networks on Load Frequency Control with Plug-in Electric Vehicles by Cyber-Physical Dynamic Co-Simulation: Preprint

With the increasing electrification of the transportation sector, vehicle to grid (V2G) control technologies are promising to improving system frequency stability. However, these control technologies might require non-traditional communication supports. This paper investigates the impacts of electric vehicles (EVs) V2G on power system frequency regulation considering communication variations through transmission-distribution-communication (TDC) dynamic simulation. The simulation model is built based on our previously developed open-source transmission-and-distribution (T&D) dynamic co-simulation framework. Here, we add the communication variation functions (i.e. delay and packet loss) to complete the TDC simulation framework. In the case studies, practical communication variation scenarios are considered when the system experiencing an N-1 generation trip contingency. The considered scenarios include communication delay and packet loss using both homogeneous and heterogeneous assumptions. The delay and packet loss rate are the same in all communication channels in the homogeneous case but varies in the heterogeneous case. The results show the communication delay has an obvious impact on the frequency recovery compared to the communication packet drop. The impacts of the standard deviations of communication delay time and packet drop rate are not significant. The outcomes of this work can help improve the EV frequency regulation services and provide robust and effect supports to the grid.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗