Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “crystal positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dynamic X-ray diffraction sampling for protein crystal positioning

A sparse supervised learning approach for dynamic sampling (SLADS) is described for dose reduction in diffraction-based protein crystal positioning. Crystal centering is typically a prerequisite for macromolecular diffraction at synchrotron facilities, with X-ray diffraction mapping growing in popularity as a mechanism for localization. In X-ray raster scanning, diffraction is used to identify the crystal positions based on the detection of Bragg-like peaks in the scattering patterns; however, this additional X-ray exposure may result in detectable damage to the crystal prior to data collection. Dynamic sampling, in which preceding measurements inform the next most information-rich location to probe for image reconstruction, significantly reduced the X-ray dose experienced by protein crystals during positioning by diffraction raster scanning. The SLADS algorithm implemented herein is designed for single-pixel measurements and can select a new location to measure. In each step of SLADS, the algorithm selects the pixel, which, when measured, maximizes the expected reduction in distortion given previous measurements. Ground-truth diffraction data were obtained for a 5 µm-diameter beam and SLADS reconstructed the image sampling 31% of the total volume and only 9% of the interior of the crystal greatly reducing the X-ray dosage on the crystal. Furthermore, by using in situ two-photon-excited fluorescence microscopy measurements as a surrogate for diffraction imaging with a 1 µm-diameter beam, the SLADS algorithm enabled image reconstruction from a 7% sampling of the total volume and 12% sampling of the interior of the crystal. When implemented into the beamline at Argonne National Laboratory, without ground-truth images, an acceptable reconstruction was obtained with 3% of the image sampled and approximately 5% of the crystal. The incorporation of SLADS into X-ray diffraction acquisitions has the potential to significantly minimize the impact of X-ray exposure on the crystal by limiting the dose and area exposed for image reconstruction and crystal positioning using data collection hardware present in most macromolecular crystallography end-stations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial testing of a Compact Crystal Positioning System for the TOPAZ Single-Crystal Diffractometer at the Spallation Neutron Source

A precise, versatile, and automated method of orienting a sub-millimeter crystal in a focused neutron beam is required for e cient operation of the TOPAZ Single Crystal Di ractometer at the Spallation Neutron Source at Oak Ridge National Laboratory. To ful ll this need, a Compact Crystal Positioning System (CCPS) has been developed in collaboration with Square One Systems Design in Jackson, Wyoming. The system incorporates a tripod design with six vacuum-compatible piezoelectric linear motors capable of < 1 m resolution. National Instruments LabVIEW provides a means of system automation while at the same time accommodating the modular nature of the SNS sample environment control software for straightforward system integration. Initial results in a cryogenic test environment will be presented, as well as results from ambient tests performed at the Advanced Photon Source at Argonne National Laboratory.

43 PARTICLE ACCELERATORS↗

Quaternary Semiconductors with Positive Crystal Field Splitting: Potential High-Efficiency Spin-Polarized Electron Sources

Traditional high efficiency spin-polarized electron sources (SPES) consist mainly of binary or pseudobinary zinc-blende GaAs based materials, whereas their ternary analogs II-IV-V{sub 2} (II = Zn, Cd, IV = Si, Ge, Sn, and V = As) as well as II-VI ternary analogs I-III-VI{sub 2} (I = Cu, Ag, III = Al, Ga, In, and VI = Se) have not drawn wide attention because their crystal field splitting {Delta}{sub CF} near the valence band maximum is either negative or close to zero in their ground state chalcopyrite structure. Using first-principles calculations, we show that some derivative quaternary I-III-II{sub 2}-VI{sub 4} and II-IV-III{sub 2}-V{sub 4} compounds can have coherent ground state stannite or kesterite structures with large and positive {Delta}{sub CF} due to their increased chemical and structural flexibility. We propose that ZnSiAl{sub 2}As{sub 4} and CdGeAl{sub 2}As{sub 4} in the stannite structure, and ZnSnGa{sub 2}As{sub 4} and CuAlCd{sub 2}Se{sub 4} in the kesterite structure could be good candidate SPES materials with high polarization and quantum efficiency.

14 SOLAR ENERGY↗

Nanoscopic strain evolution in single-crystal battery positive electrodes

Single-crystal Ni-rich layered oxides (SC-NMC) with a grain-boundary-free configuration have effectively addressed the long-standing cracking issue of conventional polycrystalline Ni-rich materials (PC-NMC) in lithium-ion batteries, prompting a shift in optimization strategies. However, continued reliance on anisotropic lattice volume change—a well-established failure indicator in PC-NMC—as a metric for understanding strain and guiding compositional design for SC-NMC becomes controversial. Here, in this study, by leveraging multiscale diagnostic techniques, we unravelled the distinct nanoscopic strain evolution in SC-NMC during battery operation, challenging the conventional composition-driven strategies and mechanical degradation indicators used for PC-NMC. Through particle-level chemomechanical analysis, we reveal a decoupling between mechanical stability and lattice volume change in SC-NMC, identifying that structural instability in SC materials is primarily driven by multidimensional lattice distortions induced by kinetics-driven reaction heterogeneity and progressively deactivating chemical phases. Using this mechanical failure mode, we redefine the roles of cobalt and manganese in maintaining mechanical stability. Unlike cobalt’s detrimental role in PC-NMC, we find cobalt to be critical in enhancing the longevity of SC-NMC by mitigating localized strain along the extended diffusion pathway, whereas manganese exacerbates mechanical degradation.

36 MATERIALS SCIENCE↗

On Forbidden Positions in Crystal Space

The finiteness of atomic volumes and symmetry impose limitations on the positions in crystal space that are allowed for occupation when crystal atomic structures are formed. The results of studying the geometric features of the forbidden regions of crystal space are presented. A new classification of symmetry space groups, based on the symmetry of crystal space forbidden regions, is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The interaction of 193-nm excimer laser irradiation with single-crystal zinc oxide: Positive ion emission

We examine UV laser-induced ion emission from a wide bandgap semiconductor, single-crystal ZnO, at fluences well below both the damage threshold and plasma formation. At fluences below 200 mJ/cm{sup 2}, we observe only Zn{sup +}, and the Zn{sup +} intensity decreases monotonically during exposure. At higher fluences, after an initial decrease, the emission is sustained; in addition O{sup +} and O{sub 2}{sup +} are observed. We explain: how Zn ions of several eV in energy can be produced on the surface of a semiconductor, how sustained emission can be maintained, and the origin of an anomalous emission of slow Zn{sup +} ions -- the latter is shown to arise from photoionization of atomic Zn, also emitted by this radiation.

36 MATERIALS SCIENCE↗

Finding a Cold Needle in a Warm Haystack: Infrared Imaging Applied to Locating Cryocooled Crystals in Loops

We demonstrate the use of inbred imaging to locate crystals mounted in cryoloops and cryopreserved in a nitrogen gas stream at 100K. In the home laboratory crystals are clearly seen in the infrared images with light transmitting through the sample while irradiating the crystal from behind, and with illumination from a direction perpendicular to the direction of view. The crystals transmit and reflect infrared radiation differently from the surrounding mother liquor and loop. Because of differences in contrast between crystals and their surrounding mother liquor, it is possible to clearly identify the crystal position. In use at the synchrotron, with robotically mounted crystals the small depth of field of the lens required the recording of multiple images at different focal points. Image processing techniques were then used to produce a clear image of the crystal. The resulting infrared images and intensity profiles show that infrared imaging can be a powerful complement to visual imaging in locating crystals in cryocooled loops.

Snell, E. H.↗

The features of identifying lines in a diffraction image formed by a widely divergent X-ray beam

A method for identifying lines in a diffraction image formed by a widely divergent X-ray beam and a technique for measuring the crystal structure parameters in the case of asymmetric crystal position have been developed. It is established that, once the distances between a crystal and a photographic plate and between the points of intersection of the hyperbola branches in a diffraction image are known, one can determine the angle between the crystal's zone axis and the wave vector, which leads to multiwave diffraction. Relations linking this angle with the parameters of two atomic planes are obtained. It is found that, to measure the parameters of atomic planes belonging to a given zone, one can use different sets of crossed hyperbolas formed by radiations K{sub {alpha}} and K{sub {beta}}. The measurements and calculations performed for the same sample (Si crystal), mounted symmetrically and asymmetrically, confirm the reliability of the proposed method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimal feedback in efficient ring double-cavity optical parametric oscillators

It is shown that the use of two feedback circuits with matched transfer constants and optimal phase incursions in a nondegenerate optical parametric oscillator (OPO) makes it possible to localise the extremes of intensity distributions of interacting waves on the output face of a nonlinear crystal, which provides maximum possible conversion efficiency of pump energy. The optimisation procedure in this case is rather flexible because it is reduced to ambiguous matching of the period and shift of the extremes of exact analytic solutions of the corresponding problem in the form of cnoidal waves with respect to the nonlinear crystal position. Unlike the single-cavity OPO scheme, both these parameters can substantially exceed the nonlinear crystal length and even tend to infinity, which corresponds to solitary soliton-like solutions. (optical parametric oscillators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure and melting behavior of classical bilayer crystals of dipoles

We study the structure and melting of a classical bilayer system of dipoles in a setup where the dipoles are oriented perpendicular to the planes of the layers and the density of dipoles is the same in each layer. Due to the anisotropic character of the dipole-dipole interactions, we find that the ground-state configuration is given by two hexagonal crystals positioned on top of each other, independent of the interlayer spacing and dipolar density. For large interlayer distances these crystals are independent, while in the opposite limit of small interlayer distances the system behaves as a two-dimensional crystal of paired dipoles. Within the harmonic approximation for the phonon excitations, the melting temperature of these crystalline configurations displays a nonmonotonic dependence on the interlayer distance, which is associated with a re-entrant melting behavior in the form of solid-liquid-solid-liquid transitions at fixed temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pressure sensor using liquid crystals

A pressure sensor includes a liquid crystal positioned between transparent, electrically conductive films (18 and 20), that are biased by a voltage (V) which induces an electric field (E) that causes the liquid crystal to assume a first state of orientation. Application of pressure (P) to a flexible, transparent film (24) causes the conductive film (20) to move closer to or farther from the conductive film (18), thereby causing a change in the electric field (E'(P)) which causes the liquid crystal to assume a second state of orientation. Polarized light (P.sub.1) is directed into the liquid crystal and transmitted or reflected to an analyzer (A or 30). Changes in the state of orientation of the liquid crystal induced by applied pressure (P) result in a different light intensity being detected at the analyzer (A or 30) as a function of the applied pressure (P). In particular embodiments, the liquid crystal is present as droplets (10) in a polymer matrix (12) or in cells (14) in a polymeric or dielectric grid (16) material in the form of a layer (13) between the electrically conductive films (18 and 20). The liquid crystal fills the open wells in the polymer matrix (12) or grid (16) only partially.

Parmar, Devendra S.↗

Automatic cryoloop alignment for protein crystals

Methods and apparatus for implementing robust and efficient cryoloop auto-centering for crystal location and alignment to the x-ray beam are provided. Image processing techniques are used for recognition of the small protein crystals. The detected crystal location enables crystal positioning in the x-ray beam, and optimization of the x-ray optics such as beam profile and intensity to the size and shape of the protein crystals.

59 BASIC BIOLOGICAL SCIENCES↗

Getting the Most Out of Your Crystals: Data Collection at the New High-Flux, Microfocus MX Beamlines at NSLS-II

Advances in synchrotron technology are changing the landscape of macromolecular crystallography. The two recently opened beamlines at NSLS-II—AMX and FMX—deliver high-flux microfocus beams that open new possibilities for crystallographic data collection. They are equipped with state-of-the-art experimental stations and automation to allow data collection on previously intractable crystals. Optimized data collection strategies allow users to tailor crystal positioning to optimally distribute the X-ray dose over its volume. Vector data collection allows the user to define a linear trajectory along a well diffracting volume of the crystal and perform rotational data collection while moving along the vector. This is particularly well suited to long, thin crystals. We describe vector data collection of three proteins—Akt1, PI3Kα, and CDP-Chase—to demonstrate its application and utility. For smaller crystals, we describe two methods for multicrystal data collection in a single loop, either manually selecting multiple centers (using H108A-PHM as an example), or “raster-collect”, a more automated approach for a larger number of crystals (using CDP-Chase as an example).

59 BASIC BIOLOGICAL SCIENCES↗

Effect of thermal processes on critical operation conditions of high-power laser diodes

Using numerical and analytical techniques in a threedimensional approximation, we have modelled the effect of spatial thermoelastic stress nonuniformity in a laser diode – heat sink system on the output characteristics of the device in different operation modes. We have studied the influence of the pulse duration, the geometry of the laser system and its thermophysical parameters on the critical pump current density, in particular for state-of-the-art heat conductive substrate materials. The proposed approach has been used to optimise the laser diode assembly process in terms of the quality of laser crystal positioning (bonding) on a heat sink. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Linear Polarizer Design for Application in the Far-Ultraviolet Spectral Range

New mission concepts that are under consideration by NASA call for the design and implementation of Far Ultraviolet (FUV) polarizer technologies that have not been developed yet. A team that includes members from the NASA Goddard Space Flight Center (GSFC), Arizona State University (ASU), and Woodruff Consulting, worked on the design and development of a polarizer design that produce very high extinction ratios in the FUV spectral range (100-200 nm). This polarizer consists of reflecting light through a series of mirrors from a combination of two silicon carbide (SiC) and two lithium fluoride (LiF) crystals positioned at angles of incidence (relative to surface normal) close to the average LiF Brewster’s angle in the FUV. The output is a highly linearly polarized beam. This polarizer concept was fabricated and tested in the existing McPherson 225 Vacuum Ultraviolet (VUV) spectrometer located in the Optics Branch at NASA-GSFC. Initial testing using a MgF2 crystal at the Brewster’s angle as an analyzer has shown that this design can produce state-of-the-art extinction ratios at the Hydrogen Lyman-Alpha (Ly-α) wavelength of 121.6 nm, and that the measured extinction ratio of the two crossed polarizers, ≈114, is mostly limited by the MgF2 analyzer. A polarizer with such a performance at this wavelength has never been reported and it signifies a breakthrough in FUV polarization technology. The levels of effectiveness paired with the polarizer’s compact design allows for a new polarizer capability that would one day be implemented in a future FUV spectropolarimetry space mission.

Far Ultraviolet (FUV)↗