NASA NTRS1998
Fatigue crack growth rate (FCGR) tests were conducted on IN 718 in the solution annealed and aged condition at room temperature in accordance with E647-87. As part of each test, the FCGR threshold was measured using the decreasing Delta K method. A new heat of material was being tested and some of this material was sent to a different laboratory which wanted to use a specimen with a 127 mm width. Threshold data previously had been established on specimens with a width of 50.8 mm. As a check of the laboratory, tests were conducted at room temperature and R equal to 0.1 for comparison with the earlier data. The results were a threshold significantly higher than previously observed. Interchanging of specimen sizes and laboratories showed that the results were not due to a heat-to-heat or lab-to-lab variation. The results to be presented here are those obtained at the original laboratory. Growth rates were measured using the electric potential drop technique at R values of 0.1, 0.7, and 0.9. Compact tension specimen sizes with planer dimensions of 25.4 mm, 50.8 mm, and 127 mm were used. Crack growth rates at threshold were generally below 2.5 X 10(exp -8) mm / cycle. Closure measurements were made on some of the specimens by a manual procedure using a clip gage. When the crack growth rate data for the specimens tested at R equal to 0.1 were plotted as a function of applied Delta K, the thresholds varied with specimen width. The larger the width, the higher the threshold. The thresholds varied from 6.5 MPa-m(exp 1/2) for the 25.4 mm specimen to 15.4 MPa-m(exp 1/2) for the 127 mm specimen. At R equal to 0.7, the 25.4 mm and 50.8 mm specimens had essentially the same threshold, about 2.9 MPa-m(exp 1/2)while the 127 mm specimen had a threshold of 4.5 MPa-m(exp 1/2). When plotted as a function of effective Delta K, the R equal to 0.1 data are essentially normalized. Various aspects of the test procedure will be discussed as well as the results of analysis of the data using some different closure models.