Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost of excess load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

River Basin Export Reduction Optimization Support Tool; a tool to screen options for reducing nutrient loads while minimizing cost

Abstract Excess loading of nitrogen and phosphorus to river networks causes environmental harm, but reducing loads from large river basins is difficult and expensive. We developed a new tool, the River Basin Export Reduction Optimization Support Tool (RBEROST) to identify the least‐cost combinations of management practices that will reduce nutrient loading to target levels in downstream and mid‐network waterbodies. We demonstrate the utility of the tool in a case study in the Upper Connecticut River Basin in New England, USA. The total project cost of optimized lowest‐cost plans ranged from $18.0 million to $41.0 million per year over 15 years depending on user specifications. Plans include both point source and non‐point source management practices, and most costs are associated with urban stormwater practices. Adding a 2% margin of safety to loading targets improved the estimated probability of success from 37.5% to 99%. The large spatial scale of RBEROST, and the consideration of both point and non‐point source contributions of nutrients, make it well suited as an initial screening tool in watershed planning.

Chamberlin, Catherine↗

Uncertainty Quantification for Capacity Expansion Planning

This report quantifies the uncertainty in output decisions from a Capacity Expansion Planning (CEP) model. The need to understand how uncertainties within CEP models and modeling assumptions affect Quantities of Interest (QoIs) such as expansion and operating costs, as well as expansion decisions remains an ongoing challenge in scientific research and industrial operations. This area of research is particularly important for models which seek to capture how large networks will evolve and operate under increased sources of variable generation, i.e., higher penetration of renewable technologies such as solar and wind generators. Uncertainty quantification (UQ) of CEP models which estimate expansion costs and decisions, and production cost models which estimate operating costs and dispatch decisions, is a key focus of research at NREL. The Regional Energy Deployment System (ReEDS) represents a state-of-the-art CEP model and considers a range of possible grid evolutions in an attempt to identify key drivers, ramifications, and decisions which contribute to better informed investment and policy decisions. However, research to quantify how uncertainties and model assumptions, such as unit commitment (UC), within ReEDS may be affecting its outputs remains challenging due to to size and complexity of the model

24 POWER TRANSMISSION AND DISTRIBUTION↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Analysis Net with Causal Embedding for Coal-fired Power Plant Fault Detection and Diagnosis (DANCE4CFDD)

Fault detection and diagnosis is critical to power plant operation to ensure attaining high reliability while reducing operation cost. As more renewable power is introduced to the power grid, traditional fossil power plants take on the extra burden of excessive load cycling to compensate the generation variability from renewable power. Such load cycling will pose more reliability challenges to power plant operation. There are a number of challenges faced by today’s asset health management system in coal- fired (or gas) power plants: 1) high-dimensional nonlinear interaction among multiple time series measurements; 2) high measurement variance induced by operational conditions/modes; 3) variation among asset types and plant configurations; and 4) a small number of faulty events to learn from. To cope with these challenges, today’s fielded asset health management systems rely heavily on manual efforts from domain experts and hand-crafted features or rules based on domain knowledge. Despite its role in plant reliability, such a practice is costly and hinders its scalability and sustainability, particularly when a plant undergoes modifications. The objective of this project is to develop a novel end-to-end AI learning system that is trainable (i.e., the AI representation of a complex system behavior can be directly learned from properly labeled data) for accurate fault detection and root cause analysis. The ability to create a fault detection model directly from time series could alleviate the efforts associated with today’s asset management solution development. In the course of this project, we have achieved the following: Created an AI model development environment incorporating state-of-the-art neural network architectures for rapid model development and evaluation; Developed novel learning strategies for training of fault detection model; Developed special-purpose neural network architecture embedded with variable association graph aiming for better interpretability; Developed a learning strategy to leverage a small number of faulty events for enhanced fault detection capability; Conducted detailed experimental study based on public benchmark datasets and demonstrated the effectiveness of the proposed solution; and Validated the developed system with data from both a coal-fired plant boiler dynamic simulation model and real-world coal-fired power plant covering multiple asset and fault types. Overall, the project attained a technology readiness level of TRL 5 from TRL 2 at the beginning of the project.

20 FOSSIL-FUELED POWER PLANTS↗

Degradation Mechanisms in Advanced MEAs for PEM Water Electrolyzers Fabricated by Reactive Spray Deposition Technology

Proton exchange membrane water electrolyzers (PEMWEs) have demonstrated enormous potential as the next generation hydrogen production technology. The main challenges that the state-of-the-art PEMWEs are currently facing are excessive cost and poor durability. Understanding the failure modes in PEMWEs is a key factor for improving their durability, lowering the precious metal loading, and hence cost reduction. Here, reactive spray deposition technology (RSDT) has been used to fabricate a membrane electrode assembly (MEA) with one order of magnitude lower Pt and Ir catalyst loadings (0.2–0.3 mg PGM cm –2 ) in comparison to the precious metal loadings in the stat-of-the-art commercial MEAs (2–3 mg PGM cm –2 ). As fabricated MEA with an active area of 86 cm 2 , has been tested for over 5000 h at steady-state conditions that are typical for an industrial hydrogen production system. Herein, we present and discuss the results from a comprehensive post-test analysis of the MEA of interest. The main degradation mechanisms, governing the performance loss in the RSDT fabricated MEA with ultra-low precious metal loadings, have been identified and discussed in detail. All failure modes are critically compared and the main degradation mechanism with the highest impact on the MEA performance loss among the others is identified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stable cycling of high-mass loaded MnO 2 electrodes for sodium-ion batteries

Achieving cost-effective, sustainable solutions for large-scale energy storage are critical for advancing the global clean energy transition. In view of the challenges posed by limited lithium reserves, low-cost sodium-ion batteries (SIBs) have emerged as a promising direction, especially for grid-level energy storage. Among the various battery electrode materials, manganese dioxide (MnO 2 ) stands out as a favorable choice for such large-scale applications due to its earth abundance, cost-effectiveness, and non-toxic nature. Although MnO 2 is known as a pseudocapacitive material with superior cycling stability in aqueous electrolytes, its dissolution in non-aqueous electrolytes has restricted its use in long-lifetime batteries. In this study, we address two issues which have limited the use of MnO 2 electrodes in non-aqueous electrolytes. First, using electrochemical quartz crystal microbalance measurements in combination with other electrochemical methods, we demonstrate that diglyme (bis(2-methoxyethyl) ether) electrolyte can achieve stable cycling of electrodeposited ε-MnO 2 . These results enable us to tackle a second objective, that is increasing the mass loading of the MnO 2 electrode, since achieving high areal energy density is a significant factor in reducing manufacturing costs. Using 3D printed graphene aerogel (GA) as a scaffold, our studies show that the electrodeposited MnO 2 /GA electrodes possess scalable properties with mass loadings from 20 to 80 mg cm −2 . The resulting electrodes exhibit areal energy densities as high as 4.4 mA h cm −2 at a current density of 10 mA cm −2 . The high mass loaded MnO 2 electrodes were incorporated as a cathode in a SIB which used TiO 2 as the anode. The SIB device exhibited excellent performance with power densities in excess of 70 mW cm −2 . These studies highlight the promise of MnO 2 electrodes for use in a low-cost technology for large-scale energy storage.

25 ENERGY STORAGE↗

Improvements to the Simplified Loads Methodology in IEC 61400-2: November 22, 2021 - November 21, 2022

The "Simplified Loads Model" (SLM) of IEC 61400-2 provides a simple methodology to assess the structural integrity of a small wind turbine (SWT). The SLM is unique to the small wind turbine standard. It was included to allow SWT manufacturers with limited resources to undertake integrity checks at a reasonable cost in time and resources and avoid the expense of detailed aeroelastic simulations. Unfortunately, the SLM has gained the reputation of being overly conservative and this has reduced its value to the SWT community and its use in SWT design and certification. Conservatism in design standards is needed but excessive conservatism is not. The aim of this report is to address the principal areas of excess conservatism and recommend changes to the SLM that preserve its simplicity but reduce the excess. The changes for the ultimate loads are consistent with their treatment in aeroelastic modelling for certification and with related codes for wind loading on structures. The recommendations for a new fatigue design load case are also based on aeroelastic simulations, in this case of five SWTs of varying configurations with rated power from 2.4 to 50 kW. It is also pointed out the design load case for yawed operation omits an important term. The recommended inclusion of this term would make the SLM slightly more conservative for this case.

17 WIND ENERGY↗

White Earth Community Facilities Solar PV Project (Final Report)

Funded project was for the design, installation, and performance monitoring of 2 - 11.4 kW AC and 1-38.0 kW AC ground-mount solar installations for three tribal community facilities, for a total 60.8 kW AC, including a daycare facility and two community centers. Of in excess of 120 tribal buildings these facilities had showed the best promise for implementing solar, based upon site characteristics, roof loads, roof orientation and building size. The White Earth Nation seeks to move forward proactively to address the following project goals and objectives: 1) Reduction of energy costs, 2) Increasing energy security for Indian Tribes and tribal members, 3) Adding 60.8 KW in renewable energy generation (solar PV), 4) Offsets, reduces coal-fired electric energy demand by 76,397 kWh, 817,448 Source Energy Btu annually, and S) Meets the overall solar PV target set in the FOA.

14 SOLAR ENERGY↗

Ultrahigh coulombic efficiency electrolyte enables Li||SPAN batteries with superior cycling performance

Raising the coulombic efficiency of lithium metal anode cycling is the deciding step in realizing long-life rechargeable lithium batteries. Here, we designed a highly concentrated salt/ether electrolyte diluted in a fluorinated ether: 1.8 M LiFSI in DEE/BTFE (diethyl ether/bis(2,2,2-trifluoroethyl)ether), which realized an average coulombic efficiency of 99.37% at 0.5 mA cm -2 and 1 mAh cm -2 for more than 900 cycles. This electrolyte also maintained a record coulombic efficiency of 98.7% at 10 mA cm -2 , indicative of its ability to provide fast-charging with high cathode loadings. Morphological studies reveal dense, dendrite free Li depositions after prolonged cycling, while surface analyses confirmed the formation of a robust LiF-rich SEI layer on the cycled Li surface. Moreover, we discovered that this ether-based electrolyte is highly compatible with the low-cost, high-capacity SPAN (Sulfurized polyacrylonitrile) cathode, where the constructed Li||SPAN cell exhibited reversible cathode capacity of 579 mAh g -1 and no capacity decay after 1200 cycles. A cell where a high areal loading SPAN electrode (>3.5 mAh cm -2 ) is paired with only onefold excess Li was constructed and cycled at 1.75 mA cm -2 , maintaining a coulombic efficiency of 99.30% for the lithium metal. Computational simulations revealed that at saturation, the Li-FSI complex forms contact ion pairs, with a first solvation shell comprising DEE molecules, and a second solvation shell with a mix of DEE/BTFE. This study provides a path to enable high energy density Li||SPAN batteries with stable cycling.

36 MATERIALS SCIENCE↗

A Self-Organizing Nano Grid (SONG) for Energy Access Clusters

In this paper, a bottom-up dc Self-Organizing Nano Grid (SONG) for rural electrification at ultra-low-cost through a flexible and scalable topology is presented. The proposed nano grid requires no communication and uses dc-bus signaling to convey excess energy in the system through the bus voltage, allowing independent agents to conduct energy transactions based on their needs in a decentralized manner. Moreover, this article proposes a concept that uses a novel multi-source, multi-segment droop control strategy with demand coordination, allowing for dynamic self-balancing of the system under fluctuating operating conditions. The unique use of a surplus photovoltaic (PV) power droop mode precisely estimates energy availability to minimize load chattering that helps in stabilizing the dc-bus. In addition, this architecture uses standard dc/dc converters for a low-cost, modular, Plug and Play ( PnP ) solution with highly automated operation, enabling local assembly, operation, and maintenance by non-technical personnel. The proposed SONG concept was validated in simulation and with a 700W, laboratory-scale, custom made nano grid system. The simulation and experimental test cases show the feasibility of the SONG system by demonstrating the proposed multi-source, multi-segment droop control strategy without load chattering under varying operating conditions.

dc-dc converter↗

Corrosion Mitigation and Increased Discharge Capacity in Aqueous Processed Thick Cathodes using Phosphoric Acid Additives

Aqueous processed cathodes for lithium-ion batteries are favorable for both cost and environmental reasons; however, these electrodes still face significant problems with increasing areal capacities (i.e. thickness). Highly basic slurry conditions (pH in excess of 12) corrode the current collector surface and evolve hydrogen gas. Consequently, bubbling at the electrode interface causes substantial damage to the dried electrode. As the loading of these electrodes is increased, damage becomes severe and results in lack of adhesion and cohesion. Here introduction of phosphoric acid to combat the rise in pH and suppress the corrosion at the current collector surface is investigated. Phosphoric acid was added in increments of 0.5, 1.0, and 1.5 wt% and the subsequent effects on slurry rheology, particle size, adhesion, and electrochemical cycling were investigated. A technique is reported for obtaining thick (6-8 mAh/cm2) cathodes that exhibit reduced surface cracking and improved rate performance as compared to control samples.

Kukay, Alexander↗

Advanced Oxygen-Free Electrolyzer for Ultra-Low-Cost H 2 Storage for Fossil Plants (Final Technical Report)

DOE’s Office of Fossil Energy and Carbon Management has determined that long-duration energy storage solutions co-located with fossil energy assets offer significant benefits to the fossil industry, electric utilities, and customers. T2M Global has developed an Advanced O 2 -Free Electrolyzer System (AES) Technology for low-cost, long-duration H 2 energy storage for fossil plants. The MW-class AES Module conceptual design aims to upgrade stranded assets (dilute/waste syngas streams, excess electricity, and waste heat) at fossil plants to higher value H 2 for additional revenue and greater sustainability. The H 2 energy storage equips fossil plants with the load following capability needed for the lucrative grid-support services market created by Variable Renewable Energy resources.

08 HYDROGEN↗

Techno-economic and environmental assessment of solar-based electrical vehicles charging stations integrated with hydrogen production

With the growing interest in adopting both commercial and residential electric vehicles (EVs) utilizing green renewable energy, the techno-economic assessment of EV charging stations with solar energy is a critical aspect of the transition to sustainable transportation. However, battery storage capacity for variable solar energy production is becoming increasingly less cost-effective due to the higher Lithium price. Complementing solar energy production and battery storage, the potential of combining green hydrogen fuel energy integration with solar energy for EV charging stations can provide a sustainable alternative to reach carbon-free transportation. This research aims to assess the technical and economic viability of grid-connected Photovoltaic (PV)-based EV charging stations across Kentucky based on existing EV load profiles. The study considers different PV system sizes, locations, orientations, and the impact of net metering policies and electricity tariffs on the profitability of the PV systems. Further, using excess PV energy, Lithium-Ion batteries will be charged, which will be assessed considering the techno-economic and environmental impacts of green EV charging stations. To further enhance green renewable energy production, we also investigated the feasibility of on-grid PV-based EV charging stations with Lithium-Ion batteries charged during low tariff periods. In comparison with these scenarios, we studied the potential benefits of integrating green hydrogen energy production using excess solar energy with and without governmental incentives. Furthermore, we assess the environmental impact of these green EV charging stations across Kentucky. Our study indicates that EV stations across Kentucky have similar techno-economic feasibility with insignificant deviation in the levelized cost of electricity, payback period, and PV energy fraction with/without Li-Ion batteries. However, with green hydrogen production, the marginal H 2 production cost indicates the first scenario (on-grid PV energy charging) is the most significant, roughly 10 USD/Kg, which is similar to 1.5 times higher than the second (charging during low-tariff periods) and the third scenarios (power grid to satisfy the demand deficit - approximately 6.5 USD/Kg). From the environmental perspective, the second scenario would be a good option for either hybrid EV/H 2 or EV charging stations in Kentucky, factoring in the hydrogen production cost and the carbon footprint.

08 HYDROGEN↗

Westinghouse advanced fuel management strategies leveraging high enrichment and high burnup fuel to optimize PWR economics

In the US, nuclear power plants have been focused on increasing electricity generation for over three decades via longer operating cycles, reduced number of outages and duration, and the implementation of power up-rates. The potential for zero-carbon emission credits and other carbon-reduction initiatives further makes nuclear power utilities to focus on increasing generation capability. Longer operating cycles provide increased energy generation and enable economic savings to nuclear utilities when the increase in fuel loading required to achieve the extended cycle energy target and resulting increase in total fuel cost is offset by the savings from outage avoidance and reduced replacement power costs. For the current licensed limits of 5 w/o {sup 235}U enrichment and 62 GWd/tU peak pin burnup, higher power density PWR plants, which are prevalent in the PWR fleet, require an excessively penalizing fraction of feed fuel assemblies to operate for the extended cycle duration, with inevitably poor fuel use and fuel cycle economics that cannot be counterbalanced by the savings on outage cost avoidance. To overcome this barrier, the nuclear industry is pursuing development of high enrichment/high burnup fuel technology ({sup 235}U enrichment up to 8 w/o and peak pin burnup up to 75 GWd/tU) which increases fuel energy generation capability and can enable high power density plants to achieve positive economics on 24-month cycle of operation. This paper presents advanced fuel management strategies developed by Westinghouse to enable transition of PWR reactors from 18-month to 24-month cycle of operation, with and without a core thermal power uprate, which are then used as basis to assess the economics of a direct transition from 18 to 24-month cycles with high enrichment/high burnup fuel. The results show that these fuel management strategies, especially if coupled with thermal power up-rates, present the opportunity for substantial economic benefits to utilities. The systematic review of fuel management strategies presented can provide an illustrative reference for decision makers as they consider how to maximize nuclear energy generation economically. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Passive Energy-Saving Solutions for Clothes Dryers: A Modeling and Experimental Study for Improved Efficiency and Affordability

Dryers are integral appliances in modern households, yet their significant power consumption remains a critical challenge for reducing energy bills and upgrades. This work presents the outcomes of a comprehensive investigation aimed at lowering the operating energy costs of the dryer through modeling and experimental approaches. Specifically, the objectives of this research are twofold: (1) to reduce energy consumption without negatively impacting drying performance or time; and (2) to ensure affordability by developing retrofittable solutions characterized by low cost and a quick payback period. These strategies promise universal applicability to all dryer categories, encompassing both gas and electric models, by tackling core issues such as unnecessary heat loss and excess energy supply, both prevalent across dryer designs. Our methodology combines robust modeling frameworks and experimental validation to target energy efficiency improvements through three primary pathways: (1) effective heat loss management using ultralow-cost insulation materials tailored for dryer systems; (2) heat management across the drying cycle, facilitated by passive heat transfer mechanisms, and (3) optimization of heat supply to the load to ensure precise energy delivery, minimizing waste. These innovations are designed to seamlessly integrate with existing dryer configurations, providing a scalable and retrofittable solution that ensures affordability without requiring substantial redesigns or expensive components. Using these methods, the study demonstrates improvement opportunities in dryer energy consumption while maintaining the desired performance. The modeling component utilizes computational simulations to evaluate the thermal and energy performance of these innovations under varied operational conditions, providing foundational insights for experimental design. By addressing critical areas such as heat loss, energy recovery, and supply optimization, this work proposes impactful solutions for lowering the energy costs in domestic clothes dryers. The ultralow-cost, retrofittable nature of the proposed strategies ensures widespread adoption potential across diverse dryer categories, making significant strides toward affordable household energy practices.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Hydrogen-Battery Hybrid Energy System on Repurposed Offshore Platforms for Efficient Clean-Energy Transition

Due to the rising global energy demand and enhanced awareness of the environmental impact of fossil fuels, the Gulf of Mexico, traditionally known for oil extraction, offers a distinct chance to repurpose the existing offshore infrastructure. With the depletion of oil reserves, it is feasible to adapt previously utilized floating platforms for extraction to generate renewable energy, specifically through wind-generated power and hydrogen production. This adaptation seeks to promote a transport system that is more ecologically friendly in the future. Offshore wind turbines serve as the main energy source, with help from battery storage and hydrogen production to enhance the overall system performance, hydrogen creation, fuel, and electricity delivery for sustainable energy production. The system is divided into two distinct cases, each evaluated for cost, performance, and feasibility, with a focus on minimizing both the Levelized Cost of Energy (LCOE) and the Levelized Cost of Hydrogen (LCOH). The first case examines the integration of offshore wind turbines with hydrogen production. Excess electricity generated by wind turbines is directed toward hydrogen production via electrolysis. The hydrogen produced can be used as fuel for vehicles or transported to the shore via pipelines. The second case investigates a technology that combines wind turbines with battery storage. The batteries possess an ability to supply electricity for a continuous duration of 4 hours maximum each day. The main objective is to reduce the LCOE by considering the battery's charging and discharging cycles, together with the uncertain attributes of wind power and battery deterioration. The produced energy can be distributed for onshore applications or utilized for the purpose of offsetting offshore loads such as subsea oil and gas production, transportation, etc. The offshore hydrogen-battery hybrid system is improved via three advanced algorithms, Particle Swarm Optimization (PSO), and Grey Wolf Optimizer (GWO). In Case 1, PSO improves hydrogen production by efficiently managing the electrolyzer’s power consumption, decreasing production costs significantly. Particle Swarm Optimization (PSO) is applied to improve the efficiency of the electrolyzer, reducing production costs and achieving an optimized CAPEX of $240.00 million (from an initial $300.00 million) and OPEX of $9.60 million per year. This system produces 4,720,000 kg of hydrogen annually, with a Levelized Cost of Hydrogen (LCOH) of $6.40/kg and an annual profit of $9.27 million. In Case 2, GWO effectively reduces the overall energy cost by improving the charge-discharge management of batteries, which extends battery life and optimizes their use. The second case focuses on integrating battery storage, optimized using the Grey Wolf Optimizer (GWO), which enhances battery charge-discharge cycles, extending battery life and lowering costs. This system achieves an optimized CAPEX of $204.80 million (from an initial $256.00 million) and OPEX of $9.29 million per year, producing 310883.39 MWh of electricity annually at a Levelized Cost of Energy (LCOE) of $86.13/MWh, with an annual profit of $6.25 million. The implementation of a comprehensive strategy results in a substantial reduction in costs, improved energy efficiency, and a dependable supply of both electric power and hydrogen, emphasizing the benefits of converting offshore oil platforms for clean energy transition. This study explores a clean strategy to enable cost-effective repurposing of offshore O&G platforms. Both cases highlight the economic and technical feasibility of transitioning offshore oil platforms to clean energy systems, demonstrating substantial cost reductions and reliable energy and hydrogen supplies for sustainable energy production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A chemically stabilized sulfur cathode for lean electrolyte lithium sulfur batteries

Lithium sulfur batteries (LSBs) are promising next-generation rechargeable batteries due to the high gravimetric energy, low cost, abundance, nontoxicity, and high sustainability of sulfur. However, the dissolution of high-order polysulfide in electrolytes and low Coulombic efficiency of Li anode require excess electrolytes and Li metal, which significantly reduce the energy density of LSBs. Quasi-solid-state LSBs, where sulfur is encapsulated in the micropores of carbon matrix and sealed by solid electrolyte interphase, can operate under lean electrolyte conditions, but a low sulfur loading in carbon matrix (<40 wt %) and low sulfur unitization (<70%) still limit the energy density in a cell level. Here, we significantly increase the sulfur loading in carbon to 60 wt % and sulfur utilization to ∼87% by dispersing sulfur in an oxygen-rich dense carbon host at a molecular level through strong chemical interactions of C–S and O–S. In an all-fluorinated organic lean electrolyte, the C/S cathode experiences a solid-state lithiation/delithiation reaction after the formation of solid electrolyte interphase in the first deep lithiation, completely avoiding the shuttle reaction. The chemically stabilized C/S composite retains a high reversible capacity of 541 mAh⋅g −1 (based on the total weight of the C/S composite) for 200 cycles under lean electrolyte conditions, corresponding to a high energy density of 974 Wh⋅kg −1 . The superior electrochemical performance of the chemical bonding-stabilized C/S composite renders it a promising cathode material for high-energy and long-cycle-life LSBs.

25 ENERGY STORAGE↗

Feasible Actuator Range Modifier (FARM), a Tool Aiding the Solution of Unit Dispatch Problems for Advanced Energy Systems

Integrated energy systems (IESs) seek to minimize power generating costs in future power grids through the coupling of different energy technologies. To accommodate fluctuations in load demand due to the penetration of renewable energy sources, flexible operation capabilities must be fully exploited, and even power plants that are traditionally considered as base-load units need to be operated according to unconventional paradigms. Thermomechanical loads induced by frequent power adjustments can accelerate the wear and tear. If a unit is flexibly operated without respecting limits on materials, the risk of failures of expensive components will eventually increase, nullifying the additional profits ensured by flexible operation. In addition to the bounds on power variations (explicit constraints),the solution of the unit dispatch problem needs to meet the limits on the variation of key process variables, including temperature, pressure and flow rate (implicit constraints).The FARM (Feasible Actuator Range Modifier) module was developed to enable existing optimization algorithms to identify solutions to the unit dispatch problem that are both economically favorable and technologically sustainable. Thanks to the iterative dispatcher–validator scheme, FARM permits addressing all the imposed constraints without excessively increasing the computational costs. In this work, the algorithms constituting the module are described, and the performance was assessed by solving the unit dispatch problem for an IES composed of three units, i.e., balance of plant, gas turbine, and high-temperature steam electrolysis. Finally, the FARM module provides dedicated tools for visualizing the response of the constrained variables of interest during operational transients and a tool aiding the operator at making decisions. These techniques might represent the first step towards the deployment of an ecological interface design (EID) for IES units.

47 OTHER INSTRUMENTATION↗