Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrosion control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis of Tank 38H (HTF-38-23-95, -96) and Tank 43H (HTF-43-23-93, -94) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory analyzed samples from Tank 38H and Tank 43H to support Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased significantly from the previous Tank 38H surface sample. The current Tank 38H subsurface sample shows similar Na, free hydroxide, and anions versus the previous subsurface sample. However, the 38H subsurface sample shows higher concentrations of Al, Ca, Fe, Mn, and Si vs. the previous Tank 38H subsurface sample. The current Tank 38H subsurface sample contained visible sludge solids in excess of the previous sample based on visual appearance. Weight percent solids measurements indicate presence of 3.0 ± 0.1 wt.% insoluble solids in the Tank 38H subsurface sample. The significant differences in the concentrations of major components between the Tank 38H surface and subsurface samples indicate significant stratification of solution species between these two locations within the Tank 38H. Savannah River Mission Completion (SRMC) personnel indicated that there were no tank-to-tank transfers into Tank 38H since early January 2023 and the 2H (16H) Evaporator was shut down on 3/26/2023 and has not operated since that time. There have been many pumped non-waste transfers of water from the H-Area diversion box 7 (HDB-7) sump into Tank 38 since the 3/26/2023 date.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-24-53, -56) and Tank 43H (HTF-43-24-54, -55) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory analyzed samples from Tank 38H and Tank 43H to support the Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased from the previous Tank 38H surface sample. The current Tank 38H subsurface sample shows similar Na, free hydroxide, and anions in comparison to the previous subsurface sample. However, the 38H subsurface sample shows lower concentrations of Al, Ca, Fe, Mn, and Si in comparison to the previous Tank 38H subsurface sample. Measurement of the wt.% insoluble solids in the Tank 38H subsurface sample and associated uncertainty analysis indicates that the calculated average wt.% insoluble solids is 0.45 ± 0.75 wt.%. Significant differences in the concentrations of major components between the Tank 38H surface and subsurface samples indicate significant stratification of solution species between these two locations within Tank 38H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-25-36, -32) and Tank 43H (HTF-43-25-33, -35) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory (SRNL) analyzed samples from Tank 38H and Tank 43H to support the Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample are similar to the previous Tank 38H surface sample. The current Tank 38H subsurface sample shows similar Na, free hydroxide, and anions in comparison to the previous subsurface sample. The current Tank 38H subsurface sample appears brown in color. Measurement of the wt.% insoluble solids in the Tank 38H subsurface sample and associated uncertainty analysis indicates that the calculated average wt.% insoluble solids is 5.5 ± 3.6 wt.%. Significant differences in the concentrations of major components between the Tank 38H surface and subsurface samples indicate stratification of solution species between these two locations within the Tank 38H. The current Tank 43H surface sample is ~ 10% diluted versus the previous Tank 43H surface sample and the Tank 43H subsurface sample is similar in composition to the previous Tank 43H subsurface sample. Information provided by SRMC on tank additions since the last ECP sampling indicates that a total of about 4,062 gallons of water was added to Tank 43H. This addition could account for the observed relatively small dilution of ~ 10% in the Tank 43H surface sample. Similar solution compositions measured in the current Tank 43H surface and subsurface samples indicate a minimal stratification within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-26-16, -17), Tank 43H (HTF 43-26-18, -19) and Tank 22 (HTF-22-26-20, -21) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory (SRNL) analyzed samples from Tank 38H, Tank 43H and Tank 22H to support the Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample are ~ 76% of the concentrations in the previous Tank 38H surface sample. The current Tank 38H subsurface sample is a clear solution with soluble species that are ~ 70% of the concentrations in the previous Tank 38H subsurface. Significant differences in the concentrations of major components between the current Tank 38H surface and subsurface samples indicate stratification of solution species between these two locations within Tank 38H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-21-24, -25) and Tank 43H (HTF-43-21-26, -27) Samples for Support of the Enrichment Control and Corrosion Control Programs

Feed limits have been established for the 2H-Evaporator system to ensure nuclear criticality is not possible and corrosion is minimized. These limits are protected by the Enrichment Control Program (ECP) and the Corrosion Control Program (CCP) that require periodic sampling and analysis to confirm that the waste supernate composition stays within the limits. Savannah River Remediation (SRR) obtained samples from two different heights within each of the two waste tanks supporting the 2H-Evaporator operations on March 26, 2021. The Tank 38H (evaporator drop tank) and Tank 43H (evaporator feed tank) samples were received by the Savannah River National Laboratory (SRNL) Shielded Cells on March 26, 2021. Analysis of these samples provides information necessary for determining compliance with the ECP and CCP. The sample characterization was requested via a Technical Task Request (TTR) and conducted based on a Task Technical and Quality Assurance Plan (TTQAP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-20-7, -8) and tank 43H (HTF-43-20-9, -10) samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample decreased significantly from the previous surface sample. The Tank 38H sub-surface sample shows only small changes in concentration for most major species in the solution from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank. The Tank 38H sub-surface sample contained a small amount of sludge solids (<1 wt%).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-20-62, -63) and Tank 43H (HTF-43-20-60, -61) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample increased from the previous surface sample. The Tank 38H sub-surface sample shows only small changes in concentration for most major species in the solution from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank. The Tank 38H surface and sub-surface samples both contained a small amount of sludge solids (<1 wt%). The Tank 43H surface and sub-surface samples are slightly more dilute than the previous samples. The Tank 43H sub-surface sample exhibits a composition more concentrated than the surface sample indicating some stratification within the tank. The Tank 38H surface and sub-surface sample both show large increases in the concentrations of uranium and plutonium likely due to the presence of sludge solids in both samples. (Note: the samples were digested and analyzed without filtration.) The total uranium concentrations of the two Tank 43H samples are similar to the previous sample results. The plutonium concentration in both Tank 43H samples appear to have decreased from the previous samples; however, the surface sample concentrations are close to the detection limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-20-103, -104) and Tank 43H (HTF-43-20-105, -106) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample decreased from the previous surface sample. The Tank 38H sub-surface sample shows only minor changes in concentration for soluble species in the solution (e.g., Na, Al, Cs-137) but a large drop in concentrations for species typically associated with sludge solids (e.g., U, Pu, Fe, Si) likely because of a decrease in sludge solids from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-21-95, -96) and Tank 43H (HTF-43-21-97, -98) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample increased from the previous surface sample. The Tank 38H sub-surface sample shows only minor changes in concentration for soluble species in the solution (e.g., Na, Al, Cs-137) relative to the previous sample, but a small decrease in concentrations for species typically associated with sludge solids (e.g., U, Pu, Fe, Si) likely because of a decrease in sludge solids from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-22-31, -32) and Tank 43H (HTF-43-22-33, -34) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Tank 38H sub-surface sample contains less sludge solids than the previous sample based on visual appearance. The small differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate only minimal stratification of solution species within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-22-91, -92) and Tank 43H (HTF-43-22-93, -94) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased slightly from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Tank 38H sub-surface sample contains more sludge solids than the previous sample based on visual appearance. The small differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate only minimal stratification of solution species within the tank. The Tank 43H surface and sub-surface samples are similar in composition to the previous samples. The similar solution compositions measured in the Tank 43H surface and sub-surface samples indicate a minimal stratification within the tank. The total uranium and plutonium in the current Tank 38H surface sample remains similar to the previous analysis. The Tank 38H sub-surface sample shows an increase in uranium and plutonium concentrations compared to the previous sample likely because of an increase in sludge solids in the current sample. The total uranium concentration in the two Tank 43H samples is essentially unchanged from previous sample results. The plutonium concentration in the Tank 43H surface sample is similar to the previous sample results while the plutonium in the Tank 43H sub-surface sample increased relative to the previous analysis. The sum of the major cations versus the sum of the major anions shows a difference of <10% for both samples from Tank 38H and for both samples from Tank 43H providing an indication of good data quality for the non-radioactive analytes in the samples. The silicon concentrations measured in the Tank 38H sub-surface sample increased compared with the previous sample results likely due to the presence of more sludge solids in the current sample. The Tank 38H surface sample silicon concentrations is similar to the previous sample results. The Tank 43H surface and sub-surface sample silicon concentrations both increased compared to the previous sample results. The samples analyzed from Tanks 38H and 43H show silicon concentrations ranging from 61.5 to 97.3 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38h (HTF-38-23-19, -20) and Tank 43H (HTF-43-23-21, -22) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most soluble species in the Tank 38H surface sample decreased significantly from the previous surface sample. The Tank 38H sub-surface sample shows changes in concentration for soluble species in the solution with some increasing and some decreasing. The current Thank 38H sub-surface sample contains visible sludge solids similar to the previous sample, i.e., less than 1%, based on visual appearance. The significant differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species between these two locations within the tank. Savannah River Mission Completion personnel indicate that ~ 150,000 gallons of Tank 22 supernate were received in Tank 38H since its last analysis during which time the 2H evaporator was not operated, so the observed stratification is expected. The Tank 43H surface and sub-surface samples are similar in composition to the previous samples. The similar solution compositions measured in the Tank 43H surface and sub-surface samples indicate a minimal stratification within the tank. The total uranium and plutonium in the current Tank 38H surface sample remains similar to the previous analysis. The Tank 38H sub-surface sample shows an increase in uranium and plutonium concentrations compared to the previous sample likely because of an increase in sludge solids in the current sample. The total uranium concentration in the Tank 43H surface sample is similar to the previous sample results while the plutonium in the Tank 43H sub-surface sample increased relative to the previous analysis. The sum of the major cations versus the sum of the major anions shows a difference of <10% for both samples from Tank 38H sub-surface sample (174 mg/L) increased compared with the previous sample. The Tank 38H surface sample silicon concentrations (27.5 mg/L) is one-half of the previous sample results. The Tank 43H surface sample silicon concentrations compared to the previous sample results indicate Si in the concentration range of 60 to 83 mg/L. Thus, these current samples analyzed from Tanks 38H and 43H show overall silicon concentrations ranging from 27.5 to 174 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sequestration and release of nitrite and nitrate in alkali-activated slag: A route toward smart corrosion control

Intercalating the corrosion inhibitive ions in hydrotalcite is a promising approach to improve the long-term efficiency of inhibitors in corrosion protection of steel in reinforced concrete. In this work, the potential of autogenously generating nitrite- and nitrate-intercalated hydrotalcite in alkali-activated slag (AAS) is investigated. The results show that the added nitrite and nitrate ions are preferably uptaken in the interlayer structure of hydrotalcite in AAS, and the sequestered nitrite and nitrate are released upon chloride exposure in seawater and NaCl solution. The incorporation of nitrite and nitrate has little detrimental effects on the chloride binding capacity of AAS but slightly enhances the chloride ingress due to the pore coarsening effect. Similar to ordinary Portland cement (OPC), AAS is more permeable to the chloride in seawater than NaCl solution. However, unlike the release of bound chloride contributed by ettringite formation in seawater-exposed OPC, the enhanced chloride ingress in seawater-exposed AAS is primarily attributed to the aggravated pH reduction at the exposure front due to brucite formation. This study contributes to the design of alkali-activated binders with a smart inhibitor releasing ability for mitigating corrosion of steel in concrete.

36 MATERIALS SCIENCE↗

Interactions between phosphate and arsenic in iron/biochar-treated groundwater: Corrosion control insights from column experiments

An increasing number of studies have reported the coexistence of arsenic (As) and phosphorus at high concentrations in groundwater, which threatens human health and increases the complexity of groundwater remediation. However, limited work has been done regarding As interception in the presence of phosphate in flowing systems. In this study, a series of experiments were conducted to evaluate the interactions between phosphate and As during As removal by iron (Fe)-based biochar (FeBC). The addition of phosphate promoted As removal by FeBC in the batch and column experiments. X-ray absorption near edge structure (XANES) analysis provided evidence of simultaneous oxidation and reduction of trivalent arsenic in the FeBC column experiment, accompanied by corrosive Fe oxidation. However, the addition of phosphate enhanced As stabilization, attributed to the As-incorporated Fe-Ca-phosphates precipitates. The involvement of phosphate decelerated the Fe corrosion and the formation of secondary minerals in the column, mediating the risk of passivation and clogging. The As retained by Fe-Ca-phosphate precipitates was more readily oxidized, resulting in higher proportions of pentavalent arsenic. In conclusion, the results of this work identify the corrosion control and sustained-release roles of phosphate in FeBC application, informing the perspective of FeBC in As-contaminated groundwater remediation and providing new insights into the interactions between phosphate and As.

54 ENVIRONMENTAL SCIENCES↗

Relationship Between the Marginal Probability of Failure for a CPP Test and the Recommended Corrosion Control Requirements for Hanford Double Shell Waste Tanks

The Hanford Site in Washington State currently stores millions of gallons of radioactive waste in underground, carbon steel, double shell tanks (DSTs) that were constructed between 1968 and 1986. A chemistry control and monitoring program has been established mitigate corrosion in order to extend the service life for the DSTs. The current waste temperatures in the DSTs are at historical lows (i.e., typically less than 50 °C). The previous chemistry control requirements were determined for conditions at temperatures significantly higher. SRNL undertook a statistically based investigation of the role of nitrate and halide ion (i.e., chloride and fluoride) induced pitting corrosion. The objective was to develop a comprehensive waste chemistry envelope for the simultaneous minimization of the pitting and SCC risks caused by halide and nitrate ions at the lower temperature conditions. On the basis of these tests, new chemistry control requirements were proposed and have since been implemented for pitting corrosion control.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Li metal addition on corrosion control of Hastelloy N and stainless steel 316H in molten LiF-NaF-KF

Molten fluoride salts are used in various energy harvesting applications such as solar collectors and molten salt nuclear reactors (MSRs). Thermodynamically driven selective dissolution of alloying elements due to impurities present within the fluoride salts have been identified to be the main corrosion mechanism for structural alloys in molten fluoride salts. Impurities in these salts, during salt preparation as well as during operation, can be difficult to control. One way to prevent the selective dissolution of active alloying elements is to make the molten salt reducing by either purifying it to remove impurities or to add some reactive metal that will react with the impurities and make the salt reducing. Here this study is focused on the corrosion behaviour of Hastelloy N and 316H stainless steel in molten LiF-NaF-KF eutectic mixture (FLiNaK) at 700°C and how this behaviour changes with the addition of Li metal as a reducing impurity. Our results indicate that the active metal addition like Li can be very effective in controlling the redox behaviour of salt, which in-turn can mitigate corrosion. Even the addition of small quantities of Li metal can mitigate the selective dissolution of active alloying elements for the tested structural materials in FLiNaK. Our results also suggest that the presence of excess amounts of Li, above the minimum concentration required to react with the impurities in FLiNaK, does not have any detrimental effect in terms of formation of new intermetallic phases at the surface of the selected alloys under tested conditions.

36 MATERIALS SCIENCE↗

Corrosion Control in Carbon Fiber Reinforced Plastic (CFRP) Composite-Aluminum Closure Panel Hem Joints

This project targeted the implementation of CFRP/Al closure panels as a drop-in replacement for all-aluminum closures used in automobile production today. The project focused on the development of corrosion fundamentals involving CFRP materials and the use of those materials in mixed-material joints. Numerous studies were completed to benchmark current materials and test mixed metal joints. Good correlation was found between outdoor exposures and laboratory cyclic corrosion testing. The insights from the corrosion testing fundamentals and benchmarking phases informed the development of low-cure adhesive and electrocoats and conductive primers for the CFRP. Adhesive and electrocoat materials were successfully developed meeting low-cure targets for bake (150C/10min). These materials were scaled-up and used to produce 5 prototype liftgates to further evaluate CFRP/Al joints in a full-scale part. The lower cure materials enabled mitigation of CTE mismatch and reduced the required bake temperature, resulting in reduced part distortion. Corrosion testing of the liftgates revealed unexpected increases in corrosion relative to the standard bake materials. While rigorous evaluation of the parts was not possible due to numerous complexities associated with prototype testing, the results provided significant insights into the material behavior of CFRP/Al joints. Key learnings from the project included a better understanding of the system complexity (interplay of substrate/primer conductivity, production of full-scale prototypes), advances in coating/adhesive design for low-cure applications involving CFRP, and advancement of corrosion test protocols for CFRP.

36 MATERIALS SCIENCE↗

Integrity Monitoring and Assessment, Prediction, Repair, and Corrosion Control of the Hanford Storage Tanks — 25213

BACKGROUND AND PROJECT TASKS Proposed work addresses focus area 1: Waste Retrieval, Transport and Closure, with particular focus on increasing volume available for tank storage 1) Refurbish/fortify existing double shell storage tanks (Tank Refurbish – Polymer Grout) 2) Robust monitoring tools for internal corrosion (Integrity Monitoring -Reference Electrodes) 3) Mitigate external corrosion (Degradation Prevention - Cathodic Protection) 4) Determine viability of constructing new tanks, and storage room creation by way of evaporation (Cost Benefit Analysis)

Shukla, Pavan K. [Savannah River National Laborato↗