Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correlated double sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

XAMPS Detectors Readout ASIC for LCLS

An ASIC for the readout of signals from X-ray Active Matrix Pixel Sensor (XAMPS) detectors to be used at the Linac Coherent Light Source (LCLS) is presented. The X-ray Pump Probe (XPP) instrument, for which the ASIC has been designed, requires a large input dynamic range on the order of 104 photons at 8 keV with a resolution of half a photon FWHM. Due to the size of the pixel and the length of the readout line, large input capacitance is expected, leading to stringent requirement on the noise optimization. Furthermore, the large number of pixels needed for a good position resolution and the fixed LCLS beam period impose limitations on the time available for the single pixel readout. Considering the periodic nature of the LCLS beam, the ASIC developed for this application is a time-variant system providing low-noise charge integration, filtering and correlated double sampling. In order to cope with the large input dynamic range a charge pump scheme implementing a zero-balance measurement method has been introduced. It provides an on chip 3-bit coarse digital conversion of the integrated charge. The residual charge is sampled using correlated double sampling into analog memory and measured with the required resolution. The first 64 channel prototype of the ASIC has been fabricated in TSMC CMOS 0.25 {micro}m technology. In this paper, the ASIC architecture and performances are presented.

43 PARTICLE ACCELERATORS↗

Design of ePixM, a fully-depleted monolithic CMOS active pixel sensor for soft X-ray experiments at LCLS-II

The LCLS-II Free Electron Laser (FEL) will produce X-ray pulses with a repetition rate of up to 1 MHz and energies between 250 eV and 5 keV. Experiments conducted at LCLS-II will require 2D imaging detectors with a unique set of features, such as high-spatial resolution, low-noise performance, high-dynamic range and high-frame rates up to 1 MHz. We present the design of ePixM, a fully-depleted monolithic CMOS detector tailored for soft X-rays applications at high-repetition rates FEL. It consists of an array of 384×192 active pixel sensors, with a pixel size of 50×50 μm 2 and a total sensitive area of 2×1 cm 2 . ePixM has been designed in a 150 nm CMOS technology on high-resistivity substrate to achieve full depletion of the substrate. Each pixel includes a Charge Sensitive Amplifier (CSA) with gain auto-ranging capability and a noise-shaper performing Correlated Double Sampling (CDS). A novel technique named correlated pre-charging removes the excess noise introduced by the gain-switching mechanism. The performance of the design has been evaluated through post-layout simulations. The Equivalent Noise Charge (ENC) of 11.3 electrons enables single-photon detection at X-ray energies down to 250 eV, and the dynamic range exceeds 10 3 photons at 500 eV thanks to the auto-ranging circuitry.

47 OTHER INSTRUMENTATION↗

A digital CDS technique and its performance testing

Readout noise is a critical parameter for characterizing the performance of charge-coupled devices (CCDs), which can be greatly reduced by the correlated double sampling (CDS) circuit. However, a conventional CDS circuit inevitably introduces new noise since it consists of several active analog components such as operational amplifiers. This article proposes a digital CDS circuit technique, which transforms the pre-amplified CCD signal into a train of digital presentations by a high-speed data acquisition card directly without the noisy CDS circuit, then implements the digital CDS algorithm through a numerical method. A readout noise of 3.3 e - and an energy resolution of 121 eV@5.9 keV can be achieved via the digital CDS technique.

42 ENGINEERING↗

A Cryogenic readout integrated circuit with analog pile-up and in-Pixel ADC for high frame rate Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit V2 (SPROCKET2) is designed to enable high frame rate readout of Skipper CCD-in-CMOS image sensors. The SPROCKET2 pixel is fabricated in a 65 nm CMOS process and occupies a 60$\mu$m $\times$ 60$\mu$m footprint. SPROCKET2 is intended to be heterogeneously integrated with a pixelated Skipper CCD-in-CMOS sensor, such that one readout pixel is connected to a multiplexed array of 16 active image sensor pixels, to match their spatial geometry. Our design benefits from the Skipper CCD-in-CMOS sensor's non-destructive readout capability to achieve exceptionally low noise through multi-sampling and averaging while optimizing for total power consumption. The pixel readout utilizes correlated double sampling to minimize 1/f noise and includes "pile-up" of ten successive samples in the analog domain before digitizing at a rate of 66.7 ksps. Measurement results of in-pixel serial SAR ADC show DNL and INL of ~0. 44 LSB and 0.58 LBS respectively. A large area array of 20,000 SPROCKET2 ADC pixels (multiplexed 1:16 to 320,000 sensor pixels) is currently under test. By reading out data over a 10 Gbps optical link, this pixel design enables a frame rate of $\sim$ 4 kfps for large sensing areas with minimal sensing deadtime. In the highest gain mode, the pixelated ADC has an input-referred resolution of 10$\mu$V with a simulated power consumption of 50$\mu$W. The pixel operates with constant current draw to minimize power-rail crosstalk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of total ionizing dose damage in COTS pinned photodiode CMOS image sensors

The characterization of total ionizing dose (TID) damage in COTS pinned photodiode (PPD) CMOS image sensors (CISs) is investigated. The radiation experiments are carried out at a {sup 60}Co γ-ray source. The CISs are produced by 0.18-μm CMOS technology and the pixel architecture is 8T global shutter pixel with correlated double sampling (CDS) based on a 4T PPD front end. The parameters of CISs such as temporal domain, spatial domain, and spectral domain are measured at the CIS test system as the EMVA 1288 standard before and after irradiation. The dark current, random noise, dark signal non-uniformity (DSNU), photo response non-uniformity (PRNU), overall system gain, saturation output, dynamic range (DR), signal to noise ratio (SNR), quantum efficiency (QE), and responsivity versus the TID are reported. The behaviors of the tested CISs show remarkable degradations after radiation. The degradation mechanisms of CISs induced by TID damage are also analyzed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

HIGH-SPEED IMAGING AND WAVEFRONT SENSING WITH AN INFRARED AVALANCHE PHOTODIODE ARRAY

Infrared avalanche photodiode (APD) arrays represent a panacea for many branches of astronomy by enabling extremely low-noise, high-speed, and even photon-counting measurements at near-infrared wavelengths. We recently demonstrated the use of an early engineering-grade infrared APD array that achieves a correlated double sampling read noise of 0.73 e{sup −} in the lab, and a total noise of 2.52 e{sup −} on sky, and supports simultaneous high-speed imaging and tip-tilt wavefront sensing with the Robo-AO visible-light laser adaptive optics (AO) system at the Palomar Observatory 1.5 m telescope. Here we report on the improved image quality simultaneously achieved at visible and infrared wavelengths by using the array as part of an image stabilization control loop with AO-sharpened guide stars. We also discuss a newly enabled survey of nearby late M-dwarf multiplicity, as well as future uses of this technology in other AO and high-contrast imaging applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing Charge-coupled Device Readout Enabled by the Floating-gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e − rms pix −1 at 19 μs pix −1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

Lin, Kenneth W. (ORCID:0000000189672281)↗

Conceptual design of a versatile radiation tolerant integrated signal conditioning circuit for resistive sensors

This paper presents the design of a radiation tolerant configurable discrete time CMOS signal conditioning circuit for use with resistive sensors like strain gauge pressure sensors. The circuit is intended to be used for remote handling in harsh environments in the International Thermonuclear Experimental fusion Reactor (ITER). The design features a 5 V differential preamplifier using a Correlated Double Sampling (CDS) architecture at a sample rate of 20 kHz and a 24 V discrete time post amplifier. The gain is digitally controllable between 27 and 400 in the preamplifier and between 1 and 8 in the post amplifier. The nominal input referred noise voltage is only 8.5 {mu}V while consuming only 1 mW. The circuit has a simulated radiation tolerance of more than 1 MGy. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

A Cryogenic Readout IC with 100 KSPS in-Pixel ADC for Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$\mu$m $\times$ 50$\mu$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successive approximation register (SAR) ADC. The circuit achieves a sample rate of 100 ksps with 0.48 $\mathrm{e^-_{rms}}$ equivalent noise at the input to the ADC. SPROCKET achieves a maximum dynamic range of 9,000 $e^-$ at the lowest gain setting (or 900 $e^-$ at the lowest noise setting). The circuit operates at 100 Kelvin with a power consumption of 40 $\mu W$ per pixel. A SPROCKET test chip was submitted in September 2022, and test results will be presented at the conference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope integrators. They are capable of working from room to cryogenic temperatures, down to 84 K. The present iteration of the ASIC has been fabricated including several design updates and the addition of an on-chip voltage reference, resulting in improved performance. This work presents the main vulnerabilities solved, the changes carried out, and the resulting performance benefits. Measurements with a skipper-CCD and the ASIC at 140 K showed that the single-electron resolution can be reached by averaging the measured charge in the analog domain using the analog pile-up technique with a readout noise as low as 0.11 erms of equivalent charge for 1200 samples. The channel-to-channel crosstalk was also characterized showing values better than -62 dB.

Alcalde Bessia, Fabricio↗

A Sub-electron-noise Skipper-CCD Readout ASIC with Improved Channel-to-channel Isolation and an Integrated Cryogenic Voltage Reference

The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope integrators. They are capable of working from room to cryogenic temperatures, down to 84 K. The present iteration of the ASIC has been fabricated including several design updates and the addition of an on-chip voltage reference, resulting in improved performance. This work presents the main vulnerabilities solved, the changes carried out, and the resulting performance benefits. Measurements with a skipper-CCD and the ASIC at 140 K showed that the single-electron resolution can be reached by averaging the measured charge in the analog domain using the analog pile-up technique with a readout noise as low as 0.11 erms of equivalent charge for 1200 samples. The channel-to-channel crosstalk was also characterized showing values better than -62 dB.

Alcalde Bessia, Fabricio↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗

X-ray scaling relations of “core” and “coreless” E and S0 galaxies

We have re-examined the two X-ray scaling relations of early-type galaxies (ETGs), L{sub X,GAS}–L{sub K} and L{sub X,GAS}–T{sub GAS}, using 61 ATLAS{sup 3D} E and S0 galaxies observed with Chandra (including ROSAT results for a few X-ray bright galaxies with extended hot gas). With this sample, which doubles the number of ETGs available for study we confirm the strong, steep correlations reported by Boroson et al. Moreover, the larger sample allows us to investigate the effect of structural and dynamical properties of ETGs in these relations. Using the sub-sample of 11 “genuine” E galaxies with central surface brightness cores, slow stellar rotations and old stellar populations, we find that the scatter of the correlations is strongly reduced, yielding an extremely tight relation of the form L{sub X,GAS} ∼ T{sub GAS}{sup 4.5±0.3}. The rms deviation is only 0.13 dex. For the gas-rich galaxies in this sample (L{sub X,GAS} > 10{sup 40} erg s{sup −1}), this relation is consistent with recent simulations for velocity dispersion supported E galaxies. However, the tight L{sub X,GAS}–T{sub GAS} relation of genuine E galaxies extends down into the L{sub X} ∼ 10{sup 38} erg s{sup −1} range, where simulations predict the gas to be in outflow/wind state, with resulting L{sub X} much lower than observed in our sample. The observed correlation may suggest the presence of small bound hot halos even in this low luminosity range. At the high luminosity end, the L{sub X,GAS}–T{sub GAS} correlation of core elliptical galaxies is similar to that found in samples of cD galaxies and groups, but shifted down toward relatively lower L{sub X,GAS} for a given T{sub GAS}. In particular cDs, central dominant galaxies sitting at the bottom of the potential well imposed by the group dark matter, have an order of magnitude higher L{sub X,GAS} than our sample core galaxies for the same L{sub K} and T{sub GAS}. We suggest that enhanced cooling in cDs, which have higher hot gas densities and lower entropies, could lower T{sub GAS} to the range observed in giant Es; this conclusion is supported by the presence of extended cold gas in several cDs. Instead, in the sub-sample of coreless ETGs—these galaxies also tend to show stellar rotation, a flattened galaxy figure and rejuvenation of the stellar population—L{sub X,GAS} and T{sub GAS} are not correlated. The L{sub X}−T{sub GAS} distribution of coreless ETGs is a scatter diagram clustered at L{sub X,GAS} < 10{sup 40} erg s{sup −1}, similar to that reported for the hot interstellar medium (ISM) of spiral galaxies, suggesting that both the energy input from star formation and the effect of galactic rotation and flattening may disrupt the hot ISM.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatially resolved gas and stellar kinematics in compact starburst galaxies

The kinematics of galaxies provide valuable insights into their physics and assembly history. Kinematics are governed not only by the gravitational potential, but also by merger events and stellar feedback processes such as stellar winds and supernova explosions. We aim to identify what governs the kinematics in a sample of SDSS-selected nearby starburst galaxies, by obtaining spatially resolved measurements of the gas and stellar kinematics. We obtained near-infrared integral-field K-band spectroscopy with VLT/SINFONI for 15 compact starburst galaxies. We derived the integrated as well as spatially resolved stellar and gas kinematics. The stellar kinematics were derived from the CO absorption bands, and Paα and Brγ emission lines were used for the gas kinematics. Based on the integrated spectra, we find that the majority of galaxies have gas and stellar velocity dispersion that are comparable. A spatially resolved comparison shows that the six galaxies that deviate show evidence for a bulge or stellar feedback. Two galaxies are identified as mergers based on their double-peaked emission lines. In our sample, we find a negative correlation between the ratio of the rotational velocity over the velocity dispersion (v rot /σ) and the star formation rate surface density. We propose a scenario where the global kinematics of the galaxies are determined by gravitational instabilities that affect both the stars and gas. This process could be driven by mergers or accretion events. Effects of stellar feedback on the ionised gas are more localised and detected only in the spatially resolved analysis. The mass derived from the velocity dispersion provides a reliable mass even if the galaxy cannot be spatially resolved. The technique used in this paper is applicable to galaxies at low and high redshift with the next generation of infrared-focussed telescopes (JWST and ELT).

79 ASTRONOMY AND ASTROPHYSICS↗

Machine learning the microscopic form of nematic order in twisted double-bilayer graphene

Modern scanning probe techniques, such as scanning tunneling microscopy, provide access to a large amount of data encoding the underlying physics of quantum matter. In this work, we show how convolutional neural networks can be used to learn effective theoretical models from scanning tunneling microscopy data on correlated moiré superlattices. Moiré systems are particularly well suited for this task as their increased lattice constant provides access to intra-unit-cell physics, while their tunability allows for the collection of high-dimensional data sets from a single sample. Using electronic nematic order in twisted double-bilayer graphene as an example, we show that incorporating correlations between the local density of states at different energies allows convolutional neural networks not only to learn the microscopic nematic order parameter, but also to distinguish it from heterostrain. These results demonstrate that neural networks are a powerful method for investigating the microscopic details of correlated phenomena in moiré systems and beyond.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An efficient random-sampling method for calculating double occupancy of Gutzwiller wave function in single-band 1D and 2D lattices

In this paper, we report a random sampling method for computing the expectation value of physical quantities based on the Gutzwiler variational wave function. As the first application, we calculated the double occupancy, which is a critical quantity for under- standing the correlation effects in many-body systems, for single-band 1D and 2D lattices. We demonstrated that the random sampling scheme is more efficient than an existing Metropolis Monte-Carlo algorithm. For the 1D Hubbard model with only nearest-neighbor hopping, our results are almost identical to the exact analytic solution. We have also studied systems to which analytic solutions are not available, including the 1D lattices with next-nearest-neighbor hopping and 2D lattices. In addition, constraints on real-space con gurations can be easily implemented in the current scheme to further improve the Gutzwiller wave function. As an example, we calculated the double occupancy for 1D Hubbard model by applying the constraint that all double-occupied sites are paired with an empty site. With enhanced correlation between double-occupied and empty sites, the constraint results in much improved ground-state energy for 1D Hubbard model with strong on-site repulsion.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nearly hyperuniform, nonhyperuniform, and antihyperuniform density fluctuations in two-dimensional transition metal dichalcogenides with defects

Hyperuniform many-body systems in d-dimensional Euclidean space R d are characterized by completely suppressed (normalized) infinite-wavelength density fluctuations, and appear to be endowed with novel exotic physical properties. Recently, hyperuniform systems of disordered varieties have been observed in the context of various atomic-scale two-dimensional (2D) materials. Here, we analyze the effects of localized defects on the density fluctuations across length scales and on the hyperuniformity property of experimental samples of two-dimensional transition metal dichalcogenides. In particular, we extract atomic coordinates from time series annular dark field-scanning transmission electron microscopy (ADF-STEM) imaging data of 2D tungsten chalcogenides with the 2H structure (Te-doped 2H-WSe 2 ) showing continuous development and evolution of electron-beam induced defects, and construct the corresponding chemical-bonding informed coordination networks between the atoms. We then compute a variety of pair statistics and bond-orientational statistics to characterize the samples. At low defect concentrations, the corresponding materials are nearly hyperuniform, characterized by significantly suppressed scattering at the zero wave-number limit (omitting forward/ballistic scattering). As more defects are introduced, the (approximate) hyperuniformity of the materials is gradually destroyed, and the system becomes non-hyperuniform even when the material still contains a significant amount of crystalline regions. At high defect concentrations, the structures become antihyperuniform with diverging (normalized) large-scale density fluctuations, mimicking those typically observed at the thermal critical points associated with phase transitions. Overall, the defected materials possess varying degrees of orientation order, and there is apparently no intermediate hexatic phase emerging. To understand the observed nearly hyperuniform density fluctuations in the slightly defected materials, we construct a minimalist structural model and demonstrate that the experimental samples can be essentially viewed as perturbed honeycomb crystals with small correlated displacements and double chalcogen vacancies. Moreover, the small correlated displacements alone can significantly degrade hyperuniformity of the perfect honeycomb structure. Therefore, even a small amount of vacancies, when coupled with correlated displacements, can completely destroy hyperuniformity of the system.

77 NANOSCIENCE AND NANOTECHNOLOGY↗