Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Specific cooling capacity of liquid nitrogen

The assumed cooling process and the method used to calculate the specific cooling capacity of liquid nitrogen are described, and the simple equation fitted to the calculated specific cooling capacity data, together with the graphical form calculated values of the specific cooling capacity of nitrogen for stagnation temperatures from saturation to 350 K and stagnation pressures from 1 to 10 atmospheres, are given.

Kilgore, R. A.↗

High Propane and Isobutane Adsorption Cooling Capacities in Zirconium-Based Metal–Organic Frameworks Predicted by Molecular Simulations

Adsorption cooling systems are emerging alternatives to traditional compression-based cooling systems due to their reduced electricity costs. Metal–organic frameworks (MOFs) have the potential to be ideal adsorbent materials for this application, as they can be tuned to have desired adsorption behavior for different refrigerants. In this study, we studied the adsorption behaviors of propane and isobutane, which are environmentally friendly refrigerants that have been recommended as substitutes for (hydro)chlorofluorocarbons, in two mesoporous Zr-based MOFs, namely, NU-1000 and NU-1003, which have the same topology but different pore sizes. Both MOFs showed high cooling capacities with the refrigerants, and for isobutane, the cooling capacities were 2 to 4 times higher than MIL-101, which is the only MOF with a previously reported isobutane adsorption cooling capacity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the cooling capacity of an RMC-Cryosystems Model LTS 4.5-025 closed-cycle helium refrigerator

The cooling capacity of a recently purchased RMC-Cryosystems Model LTS 4.5-025 closed-cycle He refrigerator was measured over the range 4-35 K. It is found that the nominal cooling capacity of 250 mW is only met or exceeded over a narrow temperature range around 4.3 + or - 0.5 K, and that, above this range, there exists a considerable region of much lower cooling capacity, not exceeding about 100 mW. It is believed that this behavior results from use of a fixed-aperture Joule-Thompson expansion valve, and might be alleviated if the J-T valve could be adjusted to compensate for changing flow within the 5-20 K temperature range. Present performance may severely limit or prevent effective use in applications where an irreducible heat inflow exists which is greater than about 100 mW, yet substantially less than the quoted capacity at about 4 K.

De Zafra, R. L.↗

Measuring cryogenic-refrigerator cooling capacity

Temperature-sensing bridge determines liquid reserve level in low-temperature heat exchanger. Device should be of interest to manufacturers of cryogenic refrigerators as well as to those who use them in conjunction with operation of electronic equipment like masers or Josephson junctions.

Wiebe, E. R.↗

Zero Boil-Off System Testing

Cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) are a part of NASA's future space exploration due to their high specific impulse for rocket motors of upper stages suitable for transporting 10s to 100s of metric tons of payload mass to destinations outside of low earth orbit and for their return. However, the low storage temperatures of LH2 and LO2 cause substantial boil-off losses for missions with durations greater than several months. These losses can be eliminated by incorporating high performance cryocooler technology to intercept heat load to the propellant tanks and modulating the cryocooler to control tank pressure. The active thermal control technology being developed by NASA is the reverse turbo-Brayton cycle cryocooler and its integration to the propellant tank through a distributed cooling tubing network coupled to the tank wall. This configuration was recently tested at NASA Glenn Research Center, in a vacuum chamber and cryoshroud that simulated the essential thermal aspects of low Earth orbit, its vacuum and temperature. Testing consisted of three passive tests with the active cryocooler system off, and 7 active tests, with the cryocooler powered up. The test matrix included zero boil-off tests performed at 90 full and 25 full, and several demonstrations at excess cooling capacity and reduced cooling capacity. From this, the tank pressure response with varied cryocooler power inputs was determined. This test series established that the active cooling system integrated with the propellant tank eliminated boil-off and robustly controlled tank pressure.

Plachta, David W.↗

Liquid Nitrogen Zero Boiloff Testing

Cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) are a part of NASAs future space exploration due to their high specific impulse for rocket motors of upper stages suitable for transporting 10s to 100s of metric tons of payload mass to destinations outside of low earth orbit and for their return. However, the low storage temperatures of LH2 and LO2 cause substantial boil-off losses for missions with durations greater than several months. These losses can be eliminated by incorporating high performance cryocooler technology to intercept heat load to the propellant tanks and modulating the cryocooler to control tank pressure. The active thermal control technology being developed by NASA is the reverse turbo-Brayton cycle cryocooler and its integration to the propellant tank through a distributed cooling tubing network coupled to the tank wall. This configuration was recently tested at NASA Glenn Research Center, in a vacuum chamber and cryo-shroud that simulated the essential thermal aspects of low Earth orbit, its vacuum and temperature. Testing consisted of three passive tests with the active cryo-cooler system off, and 7 active tests, with the cryocooler powered up. The test matrix included zero boil-off tests performed at 90 full and 25 full, and several demonstrations at excess cooling capacity and reduced cooling capacity. From this, the tank pressure response with varied cryocooler power inputs was determined. This test series established that the active cooling system integrated with the propellant tank eliminated boil-off and robustly controlled tank pressure.

Cryogenic fluid management↗

Micro- & Nano-Technology: A Critical Design Key in Advanced Thermoelectric Cooling Systems

Advanced, thermoelectric cooling technologies now are receiving more research attention to provide cooling in advanced vehicles and residential systems to assist in increasing overall system energy efficiency and reduce greenhouse gas impacts from leakage by current R-134a systems. This work explores the systems-related impacts, barriers, and challenges of using micro-technology solutions integrated with advances in nano-scale thermoelectric materials in advanced TE cooling systems. Integrated system-level analyses that simultaneously account for thermal energy transport into / dissipation out of the TE device, environmental effects, temperature-dependent TE and thermo-physical properties, thermal losses, and thermal and electrical contact resistances are presented to establish accurate optimum system designs using both BixSb2-xTe3 / Bi2Te3 TE systems and Bi2Te3 TE systems. This work established the design trends and identified optimum design regimes and metrics for these types of systems that will minimize system mass, volume and cost to maximize their commercialization potential in vehicular and residential applications. The relationships between important design metrics, like coefficient of performance, specific cooling capacity and cooling heat flux requirements, upper limits, and critical differences in these metrics in BixSb2-xTe3 / Bi2Te3 TE systems and Bi2Te3 TE systems are explored and quantified. Finally, the work discusses the critical role that micro-technologies and nano-technologies can play in enabling miniature TE cooling systems in advanced vehicle and residential applications and gives some key relevant examples.

36 MATERIALS SCIENCE↗

CryoTARPOS Vibration Mitigation System for Layered Experiments

The goal of this project is to implement a system that can eliminate or mitigate vibration so that clear images can be taken without bypassing the cryocooler. By allowing for layer characterization and cryocooler operation at the same time, cooling capacity and thermal stability of the target would be improved, and more layer characterization data could be taken. Increased cooling capacity and thermal stability could allow for layering during occasional off normal conditions that would typically result in a loss of temperature control and NIF operational delays ranging from several hours to several days per month. The increased cooling capacity and thermal stability could also allow for layering of new target platforms that have less cooling margin. Additional layer images could be used for better characterization of defects and non-uniformities in the layer and would reduce the likelihood of layer seed loss, which typically adds ~12 hours per week in layering time. Motion blur from vibration due to off normal activity in the NIF Target Bay could also be mitigated that would usually result in NIF operational delays of several hours every month.

42 ENGINEERING↗

Water Vapor Permeability of the Advanced Crew Escape Suit

Crew Exploration Vehicle (CEV) crewmembers are expected to return to earth wearing a suit similar to the current Advanced Crew Escape Suit (ACES). To ensure optimum cognitive performance, suited crewmembers must maintain their core body temperature within acceptable limits. There are currently several options for thermal maintenance in the post-landing phase. These include the current baseline, which uses an ammonia boiler, purge flow using oxygen in the suit, accessing sea water for liquid cooling garment (LCG) cooling and/or relying on the evaporative cooling capacity of the suit. These options vary significantly in mass, power, engineering and safety factors, with relying on the evaporative cooling capacity of the suit being the least difficult to implement. Data from previous studies indicates that the evaporative cooling capacity of the ACES was much higher than previously expected, but subsequent tests were performed for longer duration and higher metabolic rates to better define the water vapor permeability of the ACES. In these tests five subjects completed a series of tests performing low to moderate level exercise in order to control for a target metabolic rate while wearing the ACES in an environmentally controlled thermal chamber. Four different metabolic profiles at a constant temperature of 95 F and relative humidity of 50% were evaluated. These tests showed subjects were able to reject about twice as much heat in the permeable ACES as they were in an impermeable suit that had less thermal insulation. All of the heat rejection differential is attributed to the increased evaporation capability through the Gortex bladder of the suit.

Bue, Grant↗

Lithium chloride - Expanded graphite composite sorbent for solar powered ice maker

Consolidated composite material made from expanded graphite (EG) powder impregnated with LiCl salt is proposed for use in solar powered adsorption ice makers. Laboratory experiments were done to test the adsorption and desorption performance of the sorbent under different temperature conditions suitable for solar energy utilization. More than 75% of the reaction between LiCl and ammonia was completed after 30 min of synthesis at evaporation temperatures of -10 and -5 C and adsorption temperature between 25 and 35 C. Under the same period, it was possible to obtain 80% conversion in the desorption phase, when the generation temperatures ranged between 75 and 80 C, and the condensation temperature varied from 25 to 35 C. The highest average specific cooling power during the synthesis phase was 117 W per kg of the block. The calculated theoretical coefficient of performance (COP) under different cycle conditions was nearly constant at 0.47. Moreover, the new composite sorbent showed higher Specific Cooling Capacity (SCC), compared to activated carbon (AC)/methanol pair. Experiments done with blocks with different proportion of EG, showed that the proportion of EG influence the cooling capacity per unit mass of salt and had almost no influence on the cooling capacity per unit mass of the block. Moreover, the reaction enthalpy ({delta}H) and entropy ({delta}S) were calculated from experimental data obtained experimentally, and confirmed previous reported values. (author)

14 SOLAR ENERGY↗

Helium refrigerator

An improved helium refrigerator of the type which includes a plurality of counter-flow heat exchangers and has a maximum reserve cooling capacity when the final or low-temperature heat exchanger is substantially filled with liquid helium, and a minimum reserve cooling capacity when the low-temperature heat exchanger is substantially filled with gas. An electrical bridge circuit including a pair of temperature responsive resistors is mounted on the low-temperature heat exchanger for providing a continuous indication of the reserve cooling capacity of the refrigerator.

Ervin R Wiebe↗

Lightweight Magnetic Cooler With a Reversible Circulator

A design of a highly efficient and lightweight space magnetic cooler has been developed that can continuously provide remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. The innovative design uses a cryogenic circulator that enables the cooler to operate at a high cycle frequency to achieve a large cooling capacity. The ability to provide remote/distributed cooling not only allows flexible integration with a payload and spacecraft, but also reduces the mass of the magnetic shields needed. The active magnetic regenerative refrigerator (AMRR) system is shown in the figure. This design mainly consists of two identical magnetic regenerators surrounded by their superconducting magnets and a reversible circulator. Each regenerator also has a heat exchanger at its warm end to reject the magnetization heat to the heat sink, and the two regenerators share a cold-end heat exchanger to absorb heat from a cooling target. The circulator controls the flow direction, which cycles in concert with the magnetic fields, to facilitate heat transfer. Helium enters the hot end of the demagnetized column, is cooled by the refrigerant, and passes into the cold-end heat exchanger to absorb heat. The helium then enters the cold end of the magnetized column, absorbing heat from the refrigerant, and enters the hot-end heat exchanger to reject the magnetization heat. The efficient heat transfer in the AMRR allows the system to operate at a relatively short cycle period to achieve a large cooling power. The key mechanical components in the magnetic cooler are the reversible circulator and the magnetic regenerators. The circulator uses non-contacting, self-acting gas bearings and clearance seals to achieve long life and vibration- free operation. There are no valves or mechanical wear in this circulator, so the reliability is predicted to be very high. The magnetic regenerator employs a structured bed configuration. The core consists of a stack of thin GGG disks alternating with thin polymer insulating films. The structured bed reduces flow resistance in the regenerator and therefore the pumping work by the cryogenic circulator. This magnetic cooler will enable cryogenic detectors for sensing infrared, x-ray, gamma-ray, and submillimeter radiation in future science satellites, as well as the detector systems in the Constellation-X (Con-X) and the Single Aperture Far-Infrared observatory (SAFIR). Scientific ap p - lica tions for this innovation include cooling for x-ray micro calorimeter spectrometers used for microanalysis, cryogenic particle detectors, and superconducting tunnel junction de tectors for biomolecule mass spectrometry. The cooler can be scaled to provide very large cooling capacities at very low temperatures, ideal for liquid helium and liquid hydrogen productions.

Chen, Weibo↗

Modular Thermal Hub For Building Cooling, Heating and Water Heating

A thermally activated hub for modular, scalable, distributed cooling and heating in buildings, which uses working fluids with zero Global Warming Potential (GWP), and can run on thermal energy from combustion, low-grade waste heat, or solar energy, was developed and demonstrated in this project. The concept capitalizes on several-fold enhancements in coupled heat and mass transfer possible in microscale passages to remove the primary hurdle that has hindered the implementation of thermally activated heat pumps for more than a century. Cooling capacities of hundreds of watts to tens of kilowatts are possible simply through scaling-up of component geometry. In this project, the proof-of-concept 300 W capacity unit was successfully scaled up to 3.5 kW cooling capacity, and packaged into a compact system. These systems can be utilized for a variety of cooling, heating, and air-conditioning applications in residential and commercial buildings. Additional current and potential market opportunities include CCHP applications (military and private sector mobile power generation, and small residential and light commercial stationary power systems (engine, microturbine and fuel cell driven)), solar cooling applications, distributed process waste heat recovery applications, and long-haul transport refrigeration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Thermal Hub For Building Cooling, Heating and Water Heating

A thermally activated hub for modular, scalable, distributed cooling and heating in buildings, which uses working fluids with zero Global Warming Potential (GWP), and can run on thermal energy from combustion, low grade waste heat, or solar energy, was developed and demonstrated in this project. The concept capitalizes on several-fold enhancements in coupled heat and mass transfer possible in microscale passages to remove the primary hurdle that has hindered the implementation of thermally activated heat pumps for more than a century. Cooling capacities of hundreds of watts to tens of kilowatts are possible simply through scaling up of component geometry. In this project, the proof-of-concept 300 W capacity unit was successfully scaled up to 3.5 kW cooling capacity, and packaged into a compact system. These systems can be utilized for a variety of cooling, heating, and air-conditioning applications in residential and commercial buildings. Additional current and potential market opportunities include CCHP applications (military and private sector mobile power generation, and small residential and light commercial stationary power systems (engine, microturbine and fuel cell driven)), solar cooling applications, distributed process waste heat recovery applications, and long-haul transport refrigeration.

HVAC↗

Impacts of building geometry modeling methods on the simulation results of urban building energy models

We present that urban-scale building energy modeling (UBEM)—using building modeling to understand how a group of buildings will perform together—is attracting increasing attention in the energy modeling field. Unlike modeling a single building, which will use detailed information, UBEM generally uses existing building stock data consisting of high-level building information. This study evaluated the impacts of three zoning methods and the use of floor multipliers on the simulated energy use of 940 office and retail buildings in three climate zones using City Building Energy Saver. The first zoning method, OneZone, creates one thermal zone per floor using the target building's footprint. The second zoning method, AutoZone, splits the building's footprint into perimeter and core zones. A novel, pixel-based automatic zoning algorithm is developed for the AutoZone method. The third zoning method, Prototype, uses the U.S. Department of Energy's reference building prototype shapes. Results show that simulated source energy use of buildings with the floor multiplier are marginally higher by up to 2.6% than those modeling each floor explicitly, which take two to three times longer to run. Compared with the AutoZone method, the OneZone method results in decreased thermal loads and less equipment capacities: 15.2% smaller fan capacity, 11.1% smaller cooling capacity, 11.0% smaller heating capacity, 16.9% less heating loads, and 7.5% less cooling loads. Source energy use differences range from -7.6% to 5.1%. When comparing the Prototype method with the AutoZone method, source energy use differences range from -12.1% to 19.0%, and larger ranges of differences are found for the thermal loads and equipment capacities. This study demonstrated that zoning methods have a significant impact on the simulated energy use of UBEM. Finally, one recommendation resulting from this study is to use the AutoZone method with floor multiplier to obtain accurate results while balancing the simulation run time for UBEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Controllable Multi-Functional Heat Exchanger for Space Applications

Team Spacering will design SpaceRing, a cooling and waste heat recycling system that addresses NASA’s interest for a cooling and power-generating unit in its prototype deep space habitat[1]. The merits of this system are as follows: - Controllable cooling is critical in maintaining a habitable environment and in the functionality of life support systems, powering electronics and other devices in a spacecraft. - Power is expensive to produce in a space environment. Converting wasted thermal energy into electricity will save energy and money for the space station. Space habitation is a highly complex endeavor. Consequently, the SpaceRing must adhere to additional constraints, which include: - Lack of natural fluid or gas convection due to micro-gravity environment - Limited range for heat source and cold sink temperature - Subject to high fluctuations of incoming thermal energy - Minimal weight due to the high cost of transporting items into space After consulting with NASA and experts in thermal studies, several design objectives were identified and are listed below in order of importance: - High cooling capacity - Reliable safety control and alert system - Maximization of energy generation from wasted heat - Optimization of cooling capability and power generation - Long operational life and minimization of maintenance In space, conventional cooling systems utilize passive heat pipe systems for small-scale heat rejection and pumped pipes with heat exchangers for large-scale heat rejection. Thermal power generation in space is mainly achieved by using thermoelectric material that produces electric energy from temperature differentials. We propose a design that combines cooling and thermoelectric power generation. Using a hot pipe connected to a heat source, a cold pipe connected to a radiator, a heat exchanger in contact with both pipes, and a pump in each pipe to move the fluid, we make an active cooling system. The thermoelectric material is inserted in the heat exchanger between the hot and cold pipes to extract energy from the maximum temperature difference coming from the two pipes. It also provides controllable cooling capacity through the use of the thermoelectric material as cooling modules. We have tested our system under target heat source and sink conditions and measured the temperatures and flow rates. Our preliminary results are promising, demonstrating the output of 25 Watts of power on average. We are in the process of running control tests to compare the heat transfer performance without the thermoelectric generators, which is vital in determining whether or not the generators introduce an unacceptable amount of thermal resistance. While some control tests have been run already, the results have been noisy. We have modified our testing environment and data acquisition methods to allow for simple comparison between the control test results and thermoelectric performance results. Lastly, we have modified the heat exchanger design slightly to include acrylic baffles. This will allow the heat to flow through the heat exchanger more efficiently. We have presented our preliminary results to NASA and will deliver the final product by the end of May 2014.

Lee Xiong↗

Salt Pill Design and Fabrication for Adiabatic Demagnetization Refrigerators

The performance of an adiabatic demagnetization refrigerator (ADR) is critically dependent on the design and construction of the salt pills that produce cooling. In most cases, the primary goal is to obtain the largest cooling capacity at the low temperature end of the operating range. The realizable cooling capacity depends on a number of factors, including refrigerant mass, and how efficiently it absorbs heat from the various instrument loads. The design and optimization of "salt pills" for ADR systems depend not only on the mechanical, chemical and thermal properties of the refrigerant, but also on the range of heat fluxes that the salt pill must accommodate. Despite the fairly wide variety of refrigerants available, those used at very low temperature tend to be hydrated salts that require a dedicated thermal bus and must be hermetically sealed, while those used at higher temperature - greater than about 0.5 K - tend to be single-­‐ or poly-­‐crystals that have much simpler requirements for thermal and mechanical packaging. This paper presents a summary of strategies and techniques for designing, optimizing and fabricating salt pills for both low-­‐ and mid-­‐temperature applications.

sub-kelvin cooling↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗