Investigation of Theoretical Solutions to a Bottom-Raised Oscillating Surge Wave Energy Converter (OSWEC) Through Experimental and Parametric Studies

Experiments were conducted on a wave tank model of a bottom raised oscillating surge wave energy converter (OSWEC) model in regular waves. The OSWEC model shape was a thin rectangular flap, which was allowed to pitch in response to incident waves about a hinge located at the intersection of the flap and the top of the supporting foundation. Torsion springs were added to the hinge in order to position the pitch natural frequency at the center of the wave frequency range of the wave maker. The flap motion as well as the loads at the base of the foundation were measured. The OSWEC was modeled analytically using elliptic functions in order to obtain closed form expressions for added mass and radiation damping coefficients, along with the excitation force and torque. These formulations were derived and reported in a previous publication by the authors. While analytical predictions of the foundation loads agree very well with experiments, large discrepancies are seen in the pitch response close to resonance. These differences are analyzed by conducting a sensitivity study, in which system parameters, including damping and added mass values, are varied. The likely contributors to the differences between predictions and experiments are attributed to tank reflections, standing waves that can occur in long, narrow wave tanks, as well as the thin plate assumption employed in the analytical approach.

analytical↗

Systems and methods that use harmonic drives for converting reciprocating axial motion to continuous rotary motion, helical drives for converting reciprocating rotary motion to reciprocating axial motion and combinations thereof for converting reciprocating rotary motion to continuous rotary motion

A harmonic drive assembly and fluid-powered linear motors with both axial pistons are rotary piston arrangements incorporating the harmonic drive assembly are disclosed. The motors may be used in downhole drilling applications, but the drive assembly and/or motors may be used in other applications. The assembly, motors and methods use advanced harmonic drives, advanced helical drives, and combinations thereof with 1) motors with axial pistons and reciprocating linear rings to convert reciprocative axial motion to continuous rotary motion, and 2) motors with rotary pistons and reciprocating linear rings to rectify reciprocative rotary motion to continual rotary motion to improve performance over prior configurations. Axial pistons provide a robust simple solution for generating rotation; Rotational pistons provide increased torque generation as the torque generated is proportional to motor length. Since downhole drills are long, a high-torque motor can be produced using this method.

Raymond, David W.↗

Feasibility study for convertible engine torque converter

The feasibility study has shown that a dump/fill type torque converter has excellent potential for the convertible fan/shaft engine. The torque converter space requirement permits internal housing within the normal flow path of a turbofan engine at acceptable engine weight. The unit permits operating the engine in the turboshaft mode by decoupling the fan. To convert to turbofan mode, the torque converter overdrive capability bring the fan speed up to the power turbine speed to permit engagement of a mechanical lockup device when the shaft speed are synchronized. The conversion to turbofan mode can be made without drop of power turbine speed in less than 10 sec. Total thrust delivered to the aircraft by the proprotor, fan, and engine during tansient can be controlled to prevent loss of air speed or altitude. Heat rejection to the oil is low, and additional oil cooling capacity is not required. The turbofan engine aerodynamic design is basically uncompromised by convertibility and allows proper fan design for quiet and efficient cruise operation. Although the results of the feasibility study are exceedingly encouraging, it must be noted that they are based on extrapolation of limited existing data on torque converters. A component test program with three trial torque converter designs and concurrent computer modeling for fluid flow, stress, and dynamics, updated with test results from each unit, is recommended.

Source record↗

High power density dc/dc converter: Selection of converter topology

The work involved in the identification and selection of a suitable converter topology is described. Three new dc/dc converter topologies are proposed: Phase-Shifted Single Active Bridge DC/DC Converter; Single Phase Dual Active Bridges DC/DC Converter; and Three Phase Dual Active Bridges DC/DC Converter (Topology C). The salient features of these topologies are: (1) All are minimal in structure, i.e., each consists of an input and output bridge, input and output filter and a transformer, all components essential for a high power dc/dc conversion process; (2) All devices of both the bridges can operate under near zero-voltage conditions, making possible a reduction of device switching losses and hence, an increase in switching frequency; (3) All circuits operate at a constant frequency, thus simplifying the task of the magnetic and filter elements; (4) Since, the leakage inductance of the transformer is used as the main current transfer element, problems associated with the diode reverse recovery are eliminated. Also, this mode of operation allows easy paralleling of multiple modules for extending the power capacity of the system; (5) All circuits are least sensitive to parasitic impedances, infact the parasitics are efficently utilized; and (6) The soft switching transitions, result in low electromagnetic interference. A detailed analysis of each topology was carried out. Based on the analysis, the various device and component ratings for each topology operating at an optimum point, and under the given specifications, are tabulated and discussed.

Divan, Deepakraj M.↗

From TPL assessment to design optimization: Wave energy converter control co-design applied to the RM3

The Reference Model (RM) project developed six marine energy converter concepts using a sequential design methodology, which, while widely adopted in the industry, often overlooks interactions between system components, resulting in suboptimal designs. One such example is the Reference Model 3 (RM3), a two-body point absorber wave energy converter (WEC). An assessment using the Technology Performance Level (TPL) revealed that RM3’s low power-to-cost ratio, partly due to expensive steel construction, limits its techno-economic performance. Here, this study aims to redesign RM3 by reducing its scale and employing control co-design to integrate WEC and Power Take-Off (PTO) dynamics, constraints, and cost considerations within an optimization framework. We demonstrate the limitations of RM3’s current PTO design and explore the benefits of scaling down to enhance techno-economic viability by lowering material costs. Using WecOptTool, we conduct a parameter sweep over gear ratios and spring stiffnesses for various Commercial Off-The-Shelf generators in irregular wave conditions. Our findings emphasize the importance of aligning PTO components with WEC dynamics, showing that control co-design and strategic scaling can improve RM3’s power-to-cost ratio. This study presents a transferable example of applied control co-design for other WECs, supporting early-stage developers in their design decisions.

Off the shelf components↗

Comparative Study of Nonlinear Black-Box Modeling for Power Electronics Converters

With the increasing penetration level of renewable sources and power electronics loads in modern power systems, accurate and computationally efficient models are needed. Black-box model (BBM) could be a useful method in such systems. However, not very extensive research efforts have been made for power electronics BBM so far, and existing works mostly focus on steady-state operation, neglecting the important transient behaviors such as load transients, voltage transients, and faults. This paper presents a comparative study of three commonly used nonlinear BBM approaches for transient behaviors of power electronics converters. Comparison methods are proposed, and the evaluations are conducted under different transients using a grid-connected single-phase photovoltaic inverter. The findings of this study provide valuable references for further feasibility investigations on implementing BBMs in large-scale power electronics-rich power systems.

Qiao, Liang↗

Internal Model-Based Active Damping Strategy for a Back-to-Back Modular Multilevel Converter System for Advanced Grid Support: Preprint

The proposed work focuses on the possibility of achieving the reduction in the size of the interfacing filter for the grid connection for a back-to-back modular multilevel converter system with the use of third order LCL filters. To achieve the same attenuation, it is possible to reduce the size of the interfacing filters by the usage of third order filters. However, this kind of filtering comes with the limitation of having sustained oscillations due to lack of damping especially during transient changes. Therefore, in this work, a methodology has been proposed based on the principle of internal model to cater for this unwanted oscillations. The third order system is modeled inside the microcontroller with the damping enabled. The error between the output from the model and the actual are compared and the error is utilized to accomplish the active damping strategy. The proposed architecture is verified via computer simulations based on MATLAB/Simulink domain and various case study results along with their discussion is presented in this paper.

dq control↗

Computer controlled performance mapping of thermionic converters: effect of collector, guard-ring potential imbalances on the observed collector current-density, voltage characteristics and limited range performance map of an etched-rhenium, niobium planar converter

The effect of collector, guard-ring potential imbalance on the observed collector-current-density J, collector-to-emitter voltage V characteristic was evaluated in a planar, fixed-space, guard-ringed thermionic converter. The J,V characteristic was swept in a period of 15 msec by a variable load. A computerized data acquisition system recorded test parameters. The results indicate minimal distortion of the J,V curve in the power output quadrant for the nominal guard-ring circuit configuration. Considerable distortion, along with a lowering of the ignited-mode striking voltage, was observed for the configuration with the emitter shorted to the guard ring. A limited-range performance map of an etched-rhenium, niobium, planar converter was obtained by using an improved computer program for the data acquisition system.

Manista, E. J.↗

Parametric study of minimum converter loss in an energy-storage dc-to-dc converter

Through a combination of analytical and numerical minimization procedures, a converter design that results in the minimum total converter loss (including core loss, winding loss, capacitor and energy-storage-reactor loss, and various losses in the semiconductor switches) is obtained. Because the initial phase involves analytical minimization, the computation time required by the subsequent phase of numerical minimization is considerably reduced in this combination approach. The effects of various loss parameters on the optimum values of the design variables are also examined.

Wong, R. C.↗

Stability of Large Direct-Current Power Systems That Use Switching Converters and the Application of Switching Converters to the International Space Station

As direct-current space power systems continue to grow in size, switching power converters are playing an ever larger role in power conditioning and control. When a large direct-current system that uses power converters of this type is being designed, special attention must be placed on the electrical stability of the system and of the individual loads on the system. The impedance specification approach for system stability was accomplished as a result of cooperative work of the International Space Station program team, which consists of the NASA Lewis Research Center, the Boeing Company, and Rocketdyne Division/Rockwell International. In addition, major contributions were provided by the Virginia Polytechnic Institute and State University working under a grant to NASA Lewis.

Manners, Bruce A.↗

Mooring Load Monitoring of a Wave Energy Converter Using a Self-Synchronizing Underwater Acoustic Network

A self-synchronizing underwater acoustic network, designed for remote monitoring of mooring loads in Wave Energy Converters (WEC), has been developed and tested. This network uses Time Division Multiple Access and operates self-contained with the ability for users to remotely transmit commands to the network as needed. Each node is a self-contained unit, consisting of a protocol adaptor board, an underwater acoustic modem and a battery pack. A node can be connected to a load cell, to a topside user or to the WEC. Every node is swapable. The protocol adaptor board, named Protocol Adaptor for Digital LOad Cell (PADLOC) supports a variety of digital load cell message formats (CAN, MODBUS, custom ASCII) and underwater acoustic modem serial formats. PADLOC enables topside users to connect to separate load cells through a user-specific command.

acoustic↗

Phase substitution of spare converter for a failed one of parallel phase staggered converters

Failure detection and substitution of a spare module is provided in a system having a plurality of phase staggered modules connected in parallel to deliver regulated voltage from an unregulated source. Phase control signals applied to the active converter modules are applied to the spare module through NOR gates associated with and disabled by the power output of respective modules such that failure of any one enables its phase control signal to be applied to the spare module, thus controlling the spare module to operate in the phase position of the failed module. A NAND gate detects when any one active module fails and enables a gate in the spare module, thus activating the spare module.

Mclyman, W. T.↗

A fast time domain digital simulation technique for power converters - Application to a buck converter with feedforward compensation

Small signal analysis was performed earlier to demonstrate the marked improvement of dynamic properties and stability margins of a switching regulator employing a novel feedforward input filter compensation scheme. A large signal nonlinear recurrent time domain model is presented for the converter to analyse the transient response due to a step input change with and without the presence of the proposed feedforward loop. The results are verified with experimental data.

Kelkar, S. S.↗