A data-driven comparison of commercially available testing methods for algae characterization
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
This document is a summary of the point source analytical requirements used to demonstrate compliance for the Department of Energy (DOE) Hanford Site operations with 40 Code of Federal Regulations (CFR) Part 61, “National Emission Standards for Hazardous Air Pollutants,” (NESHAP) Subpart H, “National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities,” and the Washington Administrative Code (WAC) 246-247, “Radiation Protection – Air Emissions.” This reference collects information from multiple source documents and is not intended to create, supersede, replace or over-ride any existing contractual, DOE, federal or state statutes, regulations, compliance agreements, orders, permits, licenses or other requirements. The requirement source document governs where any difference may exist. The Hanford Mission Integration Solutions (HMIS) Environmental organization has been contracted by DOE to manage and report data collected from the sampling and monitoring of radioactive air emissions point sources, colloquially called stacks. The Environmental organization coordinates the analyses and reporting of samples collected at various facilities across the Hanford Site. These facilities operate approximately 52 stacks that require sampling, monitoring or estimating radioactive air emissions. The stacks are operated by Bechtel National, Inc. (BNI), Central Plateau Cleanup Company (CPCCo), Hanford Tank Waste Operations & Closure (H2C), Hanford Laboratory Management and Integration (HLMI), and Pacific Northwest National Laboratory (PNNL). Stack samples from CPCCo, HLMI and H2C facilities are collected by the operating contractor staff, delivered to HMIS, and then shipped to an offsite contracted laboratory for analyses. The field and laboratory sample data uploaded into the Sample Management and Analytical Results Tracking (SMART) database are used to calculate sample volumes and concentrations. Sample concentrations are evaluated for compliance with federal and state regulations, permits, and license requirements. The SMART database also calculates total curies released for sampled point sources and stacks. Point source effluent concentrations and releases are published annually in publicly available reports. The BNI and PNNL operate several DOE-Hanford Field Office (HFO) stacks subject to the requirements of 40 CFR 61, Subpart H and WAC 246-247. The concentrations, curies released and dose modeling evaluation for these stacks are included in the DOE-HFO annual radionuclide NESHAP report. The sample collection, analyses and emissions estimates for these stacks are outside the scope of HMIS contracted responsibilities and not addressed further in this document.
SAND2025-14369O QuESt PCM is a tool for modeling power system production cost. It is designed for high-fidelity representation of energy storage systems (ESS) and is part of QuESt 2.0: Open-source Platform for Energy Storage Analytics. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
SAND2021-14230 O HeatMap generates geospatial wildfire fuel models by applying machine learning algorithms to satellite imagery and weather station data. The code then leverages wildfire behavior software FlamMap to determine fire spread. It also uses PSLF software to model grid impacts and display data analytics for grid components that have been impacted by wildfire. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
The code that was developed is called SAMM (Semi-Analytic MagLIF Model). In 2015, McBride and Slutz published all of the equations that are solved by the code in the original SAMM paper: R. D. McBride and S. A. Slutz, ?A semi-analytic model of magnetized liner inertial fusion?, Phys. Plasmas 22, 052708 (2015); http://doi.org/10.1063/1.4918953. The SAMM code is now implemented in both the MATLAB and Python programming languages. Students from multiple universities have requested copies of the code so that they can become more familiar with the MagLIF concept. We would like to seek an open-source solution. There is no market value to this code, as there are plenty of more sophisticated simulation codes already available; SAMM is merely a simplified model that is purely for educational purposes. In fact, at least one graduate student (from the University of California, San Diego) has already implemented and published his own modified version of the model: J. Narkis, H. U. Rahman, J. C. Valenzuela, F. Conti, R. D. McBride, D. Venosa, and F. N. Beg, ?A semi-analytic model of gas-puff liner-on-target magneto-inertial fusion?, Phys. Plasmas 26, 032708 (2019); https://doi.org/10.1063/1.5086056. SAND2020-12244 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
SAND2025-11168O TalkPipe is a software tool to help users create and manage complex data analysis tasks involving Large Language Models. Its easy-to-use interface allows users to combine different analytical processes. TalkPipe includes a Python library, a scripting language, and can be run in a Docker container, making it simple to customize and extend. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
SAND2025-11740O Peach analytics framework for Ghidra is a software application that runs and displays custom analyses within Ghidra. The program provides a server/client architecture to dynamically run external tools. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
SAND2026-22941O GeneratorSE.jl is a Julia software package for analytical sizing of variable-speed wind turbine generators. It translates and maintains generator sizing methods from the NREL WISDEM GeneratorSE framework in a Julia package form. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
SAND2022-7062 O The Analytical Tool to Evaluate Heterogeneous Neuromorphic Architectures (ATHENA) quickly evaluates performance metrics like energy, area, and latency for an AI/ML network. It currently supports the evaluation of analog neural networks. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.
SAND2024-11125O The Maximum Switching Throughput Density Estimator software performs a simple analysis that estimates the maximum logic switching throughput density that’s achieved in various CMOS technology nodes on the International Roadmap for Devices and Systems. This software utilizes simple device models and optimization techniques, performing a simple sweep over a range of possible logic supply voltages, and analytically calculating the maximum switching frequency for the given logic voltage that meets the power density constraint. It does this by using simple models of power dissipation in conventional and fully adiabatic switching. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
In this study we evaluate PII and other PV adoption timelines from 2017-2021. We use project-level data collected by the National Renewable Energy Laboratory (NREL) for the Solar Time-Based Residential Analytics and Cycle Time Estimator (SolarTRACE). Additionally, we conducted a survey of 171 AHJs about their experiences, challenges, and process changes during the first 18 months of the COVID-19 pandemic. The survey findings were supplemented with follow up interviews with 5 AHJs from 4 states. We find that the pandemic moderately increased the duration and variability of pre-install timelines (contract signing to install), particularly in the permit review phase (permit submit to approval). In contrast, post-install timelines (install to final utility interconnection) continued to decline during the pandemic. The net result is that overall project timelines (contract signing to final interconnection) continued to decline during the pandemic. Our findings suggest that AHJs and installers faced challenges throughout the pandemic but ongoing improvements in PII processes - particularly post-install processes - more than offset these challenges. Furthermore, the pandemic may have catalyzed or accelerated a widespread adoption of online/electronic permitting, among other process efficiency improvements.
Iron nitride magnets offer the potential for large magnetic remanence magnets absent any rare earth materials [1]. This project was submitted in response to the funding opportunity announcement (FOA) from the Advanced Manufacturing Office (AMO) of the Office of Energy Efficiency & Renewable Energy (EERE) of the Department of Energy (DOE): DE-FOA-0001465: Advanced Manufacturing Projects for Emerging Research Exploration; Topic Area 1: Advanced Materials; Subtopic 1.1: Innovative Advanced Materials Manufacturing for Clean Energy to explore nitriding iron powder using a fluidized bed technique which if successful would accomplish nitriding the iron powder with reduce industrial energy intensity. Of particular concern when using metal powders at high temperatures in a fluidized bed reactor is the defluidization temperature of the bed, also known as the ‘bed collapse’ temperature. Above the defluidization temperature the metal powders can no longer fluidize and instead become an undesirable packed powder bed. Using the published results from the Institute of Process Engineering at the Chinese Academy of Sciences in Beijing, China, FeNix Magnetics was able to develop a spreadsheet calculation that allowed predictive guidelines for the defluidization temperature of iron powder based on the type of carrier gas, flow rate of the carrier gas, and the iron powder diameter. FeNix Magnetics was not able to conclude whether the temperatures to avoid bed defluidization that were achievable in a fluidized bed reactor actually resulted in nitriding the iron powder to the required level. In order to measure the amount of nitrogen in the iron powder, FeNix Magnetics contracted with the DOE sponsored Advanced Photon Source (APS) at Argonne National Laboratory to conduct X-Ray diffraction measurements. Unfortunately, due to COVID-19 restrictions, the DOE sponsored APS was closed and unable to provide X-Ray Diffraction measurements during this program.
As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used by workers at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on BY-110 and BY-108 headspace vapors, respectively. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the BY-110 headspace vapors, and two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed for the BY-108 headspace vapors. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing of vapors from the BY-110 and BY-108 headspaces. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.
This data package contains surface water chemistry measurements collected in 2025 to evaluate how beaver damming and low-tech process-based stream restoration influence water quality and metal mobility in mountainous headwater systems of the Upper Colorado River Basin. Sampling was conducted at Trail Creek (Taylor Park watershed, Colorado), a tributary undergoing restoration through installation of low-tech process-based structures (i.e., beaver dam analogs), and at off-channel beaver ponds within the East River floodplain (East River watershed, Colorado). Samples were collected along longitudinal transects spanning upstream control reaches, beaver-influenced ponded reaches, and downstream segments. Additional samples were collected from near-surface pore waters within a beaver dam seepage face. The dataset includes concentrations of major and trace elements measured by inductively coupled plasma–mass spectrometry (ICP-MS) and inductively coupled plasma–optical emission spectrometry (ICP-OES), major anions measured by ion chromatography (IC), and dissolved organic carbon (DOC; reported as non-purgeable organic carbon, NPOC). Samples were size-fractionated at 0.45 micrometers (µm), 0.22 µm, and 0.02 µm to distinguish particulate (>0.45 µm), colloidal (0.22–0.02 µm), and dissolved (<0.02 µm) fractions. The data package consists of comma-separated value (.csv) files containing tabulated chemical concentration data, sample metadata (site identifiers, geographic coordinates, sampling dates, fraction type), and quality control flags. All files are provided in open, non-proprietary formats that can be accessed using standard data analysis software such as Microsoft Excel, R, Python, MATLAB, or other programs capable of reading .csv files. Units, detection limits, and analytical methods are documented in accompanying metadata files. The dataset is designed to support analyses of (1) how beaver impoundment and restoration structures alter elemental partitioning and transport, (2) the role of iron and organic carbon in mediating trace metal mobility, and (3) reach-scale changes in water quality across restoration gradients. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.
SCALE is a comprehensive modeling and simulation suite for nuclear safety analysis and design developed and maintained by Oak Ridge National Laboratory under contract with the U.S. Nuclear Regulatory Commission, U.S. Department of Energy, and the National Nuclear Security Administration to perform reactor physics, criticality safety, radiation shielding, and spent fuel characterization for nuclear facilities and transportation/storage package designs. Visit the SCALE website for additional information.
HPC ODA Commons is a community-driven platform for standardizing HPC operational data analytics. HPC sites generate enormous volumes of operational data - scheduler logs, accounting records, monitoring streams - but turning that data into actionable insight is needlessly hard. Each site builds bespoke parsers, schemas, and evaluation pipelines. Results can't be compared across institutions. Promising analytics ideas stay siloed because there's no shared language for describing the data, the experiments, or the outcomes. HPC ODA Commons fixes this by establishing community-governed contracts - versioned schemas, canonical artifacts, and benchmark recipes - that make ODA workflows discoverable, reproducible, and comparable. It pairs these standards with a practical, CLI-first toolkit that lets operators and researchers go from raw logs to standardized results without sending data off-cluster.
SAND2025-04589O pdas-experiments automates computational experiments of fluid flow simulations. It uses the pressio-demoapps-schwarz package as a basis to break down complex simulations into smaller, manageable parts. This application is an extension of the Sandia Pressio software which uses domain decomposition to work with complex simulations more efficiently. Users can test different simulation setups, while keeping a detailed record of their experiments so they can be reproduced later. The software includes a C++ program that runs individual experiments based on user-defined settings in a YAML file, as well as a Python script that can manage multiple simulations at once. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.