Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous-wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Efficient continuous-wave normal conducting accelerator for industrial applications

A normal conducting, high power, high efficiency copper linear accelerator prototype is being developed for industrial applications. The system will be powered by low-cost high-efficiency magnetron RF sources and will use a gridded thermionic cathode electron gun. Leveraging the significant accelerator expertise at JLab and industry partners, these technologies will be combined to deliver high-power (>100 kW) electron beams with energies of 1 MeV or higher that are cost-effective to produce and operate. The design is modular such that energy and power can be increased by adding additional sections as required. The status of the design, prototype fabrication and plans for a beam demonstration at JLab are described.

Accelerator Physics↗

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗

Transport of 12 GeV positron beams at Ce+BAF

Jefferson Lab (JLab) is developing a concept to upgrade the Continuous Electron Beam Accelerator Facility (CEBAF) to additionally deliver spin-polarized continuous-wave positron beams for its nuclear physics program users (Ce+BAF 12 GeV). The concept involves repurposing the Low Energy Recirculator Facility (LERF) at JLab as a dual injector, first producing 100-300 MeV spin-polarized electron beams which are subsequently used for the generation and formation of 123 MeV continuous-wave positron beams. The positron beams are transported to CEBAF and injected for acceleration up to 12 GeV, tailored to the requirements of its four experimental halls. Given the higher emittance of the secondary positron beams, the CEBAF optics are optimized for low dispersion and low beta functions to enhance transmission within the Ce+BAF acceptance limits and with an R56 to manage the positron beams bunch length and energy spread. Potential bottlenecks are being investigated through both optical modeling and measurements using an electron beam, as well as degraded electron beams, to map the 6d acceptance of CEBAF as it is today. This presentation shares preliminary results from multi-particle tracking simulations of the positron beam up to 12 GeV, including spatial, momentum, and spin characteristics, and explores the feasibility of delivering beams simultaneously to multiple experimental halls via extraction optics.

Accelerator Physics↗

A new cw-NMR Q-meter for dynamically polarized targets for particle physics

Polarized solid targets produced via Dynamic Nuclear Polarization rely on Continuous-Wave Nuclear Magnetism Resonance measurements to accurately determine the degree of polarization of bulk samples polarized to nearly 100%. Since the late 1970's phase sensitive detection methods have been utilized to observe the magnetization of a sample as a small change in inductance under RF excitation near the Larmor frequency of the nuclear species of interest, using a device known as a Q-meter. Liverpool Q-meters, produced in the UK in the 80's and 90's, have been the workhorse devices for these targets for decades, however their age and scarcity has meant new systems are needed. In conclusion, we describe a Q-meter system designed and built at Jefferson Lab in the Liverpool style to have comparable electronic performance with several improvements to update and adapt the devices for modern use.

Dynamic nuclear polarization↗

Molecular Diradical Spin Qubits in a Crystalline Host as a Platform for Quantum Sensing

Doping a luminescent tris(2,4,6-trichlorophenyl)methyl diradical m (TTM) 2 into a host crystal of its diamagnetic precursor m (HTTM) 2 creates a molecular color center with enhanced optical-spin interface properties important for quantum sensing. Optical polarization of the |T 0 ⟩ sublevel of the diradical triplet ground state is achieved by spin-selective intersystem crossing from the |T + ⟩ and |T – ⟩ sublevels of the triplet excited state at ambient and cryogenic temperatures. Coherent spin control of m (TTM) 2 doped into m (HTTM) 2 using pulsed optically detected magnetic resonance (ODMR) spectroscopy results in a 10-fold improvement in ODMR contrast over that observed for randomly oriented m (TTM)2 using continuous-wave ODMR. The diradical doped crystal powders achieve spin coherence times of 2.8, 3.4, and 7.4 μs at 294, 85, and 5 K, respectively. The diradical photoluminescence is sensitive to weak applied magnetic fields independent of temperature, excitation wavelength, and dopant concentration, providing a promising pathway toward robust quantum sensing of anisotropic magnetic fields under ambient conditions.

crystal structure↗

Tunable Metasurface External-Cavity Quantum Cascade Lasers up to 5.74 THz

Vertical-external-cavity surface-emitting lasers based on amplifying quantum-cascade metasurfaces are demonstrated in the 5–6 THz range for the first time. Enhanced parasitic coupling to lossy surface modes requires updated design guidelines, while elevated losses and lower available material gain limit the scaling of the metasurface period from previous designs. A series of metasurface devices with varying periods employing both uniform and focusing metasurfaces is fabricated and characterized. Reducing the metasurface period below 70% of the free-space wavelength enables devices with superior performance, achieving pulsed operation up to 5.74 THz with peak output powers of 1.3 mW, maximum operating temperatures up to 83 K, and continuous-wave operation up to 54 K with 23 μW of output power. In the best case, single-mode tuning from 5.23–5.73 THz, which corresponds to a 9.1% fractional tuning, is realized with near-Gaussian far-field profiles maintained across the entire range. Finally, these results establish quantum cascade vertical-external-cavity surface-emitting lasers as promising candidates for high-frequency local oscillator applications in heterodyne spectroscopy.

gallium arsenide↗

A Conjugated Oligoelectrolyte Exhibiting Room Temperature Spin-Correlated Radical Pair Character for Biological Sensing

We report a water-soluble conjugated oligoelectrolyte (COE) composed of carbazole-benzophenone, COE-CbzBP, that exhibits photogenerated spin-correlated radical pair (SCRP) behavior sensitive to static electric fields from DNA but not from lipid bilayers. The SCRP forms from a thermally activated, spin-polarized state enabled by partial π-conjugation disruption at the donor–acceptor (carbazole-benzophenone) nitrogen–carbon (N–C) junction, which facilitates a twisted intramolecular charge-transfer (TICT) geometry. This state minimizes the singlet–triplet energy gap (ΔE ST = 0.12 eV), radical–pair exchange coupling (J RP ∼ ΔE ST /2), and charge separation free energy (ΔG CS ) in both DNA (−0.19 eV) and lipid bilayers (−0.55 eV). Room-temperature continuous-wave electron paramagnetic resonance (CW-EPR) reveals a photogenerated spin-polarized singlet for COE-CbzBP that splits upon DNA association, consistent with modulation of J RP and hyperfine coupling (A x ), presumably via electric field-spin coupling. No spin-polarized signal was observed under dark, cryogenic conditions, or in liposomes, but was quenched by the spin trap 4-POBN. Transient absorption and spectroelectrochemistry confirmed magnetic-field sensitive long-lived excited-state absorption features attributed to charge-separated states 3 [Cbz •+ -BP •– ]*, which were lengthened by DNA, and quenched in lipid bilayers and 4-POBN. Quantum chemical simulations show that planar geometries (lipid-like) increase ΔE ST by 0.31 eV compared to TICT-optimized structures. This geometry-dependent modulation explains the absence of SCRP signatures in rigid environments, underscoring the importance of TICT states, minimized ΔE ST , and favorable ΔG CS for achieving room-temperature SCRP generation. These findings establish design principles for TICT-enabled molecules exhibiting qubit-like behavior that operate under ambient and biologically relevant conditions, with direct implications for quantum information science (QIS).

Aromatic compounds↗

Enhanced sensitivity for electron affinity measurements of rare elements

The electron affinity (EA), the energy released when a neutral atom binds an additional electron, is a fundamental property of atoms that is governed by electron-electron correlations and is strongly related to an element’s chemical reactivity. However, conventional techniques for EA determination lack the experimental sensitivity to probe very scarce samples. As a result, the EA for the heaviest elements of the periodic table is entirely uncharted. Here, we present a novel technique to determine EAs through Laser Photodetachment Threshold Spectroscopy, performed in an electrostatic ion beam trap to increase the samples’ exposure to laser photons and, thus, improve the experimental signal sensitivity by three orders of magnitude. Moreover, the additional exposure time allows the use of lower-power continuous-wave narrow-band lasers that reduce uncertainties associated with broadening effects induced by the laser bandwidth. By applying this technique, we measure the EA of 35 Cl to be 3.612720(44) eV, achieving state-of-the-art precision while employing five orders of magnitude fewer anions. The demonstrated sensitivity paves the way for systematic EA measurements across isotopic chains - including isotope shifts and hyperfine splittings - and ultimately for the first direct determination of electron affinities in superheavy elements.

Maier, F. M. [Univ. of Greifswald (Germany); Europ↗

Experimental study of high-energy single-pulse nanosecond discharges in pin-to-pin configuration

Single-pulse pin-to-pin nanosecond pulsed discharges in ambient air (gap distances of 3–7 mm) were investigated at high pulse energies (∼20–30 mJ deposited energy per 11 ns full width at half maximum pulse). A Michelson interferometry setup (532 nm continuous-wave laser) was employed to record time-resolved interferograms of the discharge, enabling spatially resolved calculation of the electron number density. An intensified charge-coupled device camera was used to capture the spatiotemporal evolution of the discharge (streamer formation and spark channel development), and Coherent Anti-Stokes Raman Spectroscopy (CARS) was used to measure post-discharge N 2 vibrational temperatures. Discharge current and voltage were monitored with a back-current shunt. The discharge was initiated with simultaneous cathode-directed and anode-directed streamers that bridge the gap within ∼1 ns and form a luminous, filamentary plasma channel immediately after breakdown. Laser interferometry measurements showed peak electron number densities of the order of 10 1 7–10 18 cm −3 , occurring about 15–20 ns after pulse arrival at the discharge gap. Shorter gap discharges yielded higher peak electron densities, consistent with the higher energy density in the smaller gaps. Spatially, the electron density was highest near the electrodes and decreased toward the midgap region, with 5 and 7 mm gaps exhibiting a pronounced drop in the central channel. CARS indicated initial vibrational temperatures of approximately 4000–6000 K in the spark core of ∼50 ns after the discharge onset, decaying on a ∼500 ns timescale as the plasma cooled and recombined.

Coherent anti-Stokes Raman spectroscopy↗

Outlook for active plasma spectroscopy with entangled two-photon absorption

Entangled two-photon absorption (ETPA) exhibits a quantum-enhanced two-photon absorption cross-section and a linear scaling with incident power that exceeds classical two-photon absorption (TPA) at low photon flux. Here, we assess the feasibility and applications of ETPA for active plasma spectroscopy. The ETPA-absorbed power for an Ar + species in a helicon plasma scenario is calculated to be as high as 0.6 nW cm −1 along the incident beam path for nondegenerate-entangled photon pairs that are near-resonant with an intermediate level. The ETPA absorption power exceeds classical TPA and Bremsstrahlung emission, a necessary condition for a feasible fluorescence measurement. Applications of ETPA plasma spectroscopy may include trace impurity detection, ground-state excitation, and continuous-wave pumping for high-bandwidth turbulence measurements. Possible benefits of plasma measurements are less harm to optical components with lower incident flux and reduced stray light that can contaminate optical diagnostics.

active plasma spectroscopy↗

Planar laser-induced fluorescence system for spatiotemporal ion velocity distribution function measurements

In this work, we present a planar laser-induced fluorescence (PLIF) system for measuring two-dimensional (2D), spatiotemporally resolved ion velocity distribution functions (IVDFs). A continuous-wave tunable diode laser produces a laser sheet that irradiates the plasma, and the resulting fluorescence is captured by an intensified CCD (ICCD) camera. Fluorescence images recorded at varying laser wavelengths are converted into 2D IVDFs using the Doppler shift principle. The developed diagnostic is implemented in an electron beam generated E × B plasma with a bulk plasma density of $\sim\!\!{10^{10}}{\text{c}}{{\text{m}}^{ - 3}}$ . The developed diagnostic is validated against a conventional single-point LIF method using photomultiplier tube-based detection, while significantly reducing the total measurement time by the number of spatial positions measured. The time-resolving capability of this diagnostic is tested by oscillating the plasma between two nominal operating modes with different density profiles and triggering the ICCD camera by the externally driven plasma oscillation. The measured 2D IVDF maps reveal several signatures of ion dynamics in this plasma source, including radially outflowing ions across the electric field and anomalous ion heating at the periphery, consistent with recent kinetic simulations and theoretical studies. A possible correlation between these ion kinetic features and rotating spoke structures is discussed.

E×B plasma↗

Development of thermal joints for conduction-cooling applications

Abstract In support of the development of conduction-cooled superconducting radiofrequency (SRF) niobium cavities for use in continuous-wave linear accelerators, an experimental study of thermal contact resistance was performed on bolted joints using high-purity niobium, aluminium, and copper along with Apiezon N grease and indium foil as interfacial materials. The geometry of each joint investigated aims at replicating the design adopted in conduction-cooled SRF cavities currently under development at Jefferson Lab. The materials’ thermal conductivity and the joints’ thermal resistance were measured in the temperature range of 3.5 - 10 K. The results showed that the low thermal contact resistance of 2-4 K·cm 2 /W at 4.3 K achieved with Al-In-Nb and Al-Apiezon N-Cu joints should allow the operation of conduction-cooled SRF cavities at a targeted accelerating gradient of ∼10 MV/m.

Lewis, J. [Old Dominion University]↗

Phase-Dependent Squeezing in Dual-Comb Interferometry

Manipulating the quantum noise of continuous-wave lasers through squeezing has reshaped optical interferometry. However, progress in optical frequency comb interferometry with pulsed squeezed sources has been limited, despite the role of frequency combs in ultraprecise optical metrology. Here, we introduce a new time-domain approach to characterizing squeezed femtosecond light pulses using dual-comb interferometry. Time-domain interferograms are generated via multiheterodyne beating between the modes of a Kerr soliton-squeezed frequency comb and a coherent state comb. The interferogram noise reveals phase-dependent squeezing and antisqueezing, dipping as much as 3.8 ± 0.2 dB below the shot noise level at alternating zero crossings. We model this nonstationary quantum noise as a periodic optical displacement of the squeezed comb by the coherent comb. These results support a route toward quantum-enhanced dual-comb timing applications and high-speed quantum state tomography with dual-comb interferometers.

Herman, Daniel Issac [University of Colorado, Boul↗

Magneto-optical spectroscopy based on pump-probe strobe light

Here, we demonstrate a pump-probe strobe light spectroscopy for sensitive detection of magneto-optical dynamics in the context of hybrid magnonics. The technique uses a combinatorial microwave-optical pump-probe scheme, leveraging both the high-energy resolution of microwaves and high-efficiency detection using optical photons. In contrast with conventional stroboscopy using continuous-wave light, we apply microwave and optical pulses with varying pulse widths, and demonstrate magneto-optical detection of magnetization dynamics in Y 3 Fe 5 O 12 films. The detected magneto-optical signals depend strongly on the characteristics of both the microwave and the optical pulses, as well as their relative time delays. We show that good magneto-optical sensitivity and coherent stroboscopic character are maintained, even at a microwave pump pulse of 1.5 ns and an optical probe pulse of 80 ps, under a 7 MHz clock rate, corresponding to a pump-probe footprint of approximately 1% in one detection cycle. Our results show that time-dependent strobe light measurement of magnetization dynamics can be achieved in the gigahertz frequency range under a pump-probe detection scheme.

36 MATERIALS SCIENCE↗

Real-Time High-Accuracy Digital Wireless Time, Frequency, and Phase Calibration for Coherent Distributed Antenna Arrays

his work presents a fully-digital high-accuracy real-time calibration procedure for frequency and time alignment of open-loop wirelessly coordinated coherent distributed antenna array (CDA) modems, enabling radio frequency (RF) phase coherence of spatially separated commercial off-the-shelf (COTS) software-defined radios (SDRs) without cables or external references such as the global navigation satellite system (GNSS). Building on previous work using high-accuracy spectrally-sparse time of arrival (ToA) waveforms and a multistep ToA refinement process, a high-accuracy two-way time transfer (TWTT)-based time–frequency coordination approach is demonstrated. Due to the two-way nature of the high-accuracy TWTT approach, the time and frequency estimates are Doppler and multipath tolerant, so long as the channel is reciprocal over the synchronization epoch. This technique is experimentally verified using COTS SDRs in a lab environment in static and dynamic scenarios and with significant multipath scatterers. Time, frequency, and phase stability were evaluated by beamforming over coaxial cables to an oscilloscope which achieved time and phase precisions of ~60– 70 ps , with median coherent gains above 99% using optimized coordination parameters, and a beamforming frequency root-mean-square error (RMSE) of 3.73 ppb in a dynamic scenario. Finally, experiments were conducted to compare the performance of this technique with previous works using an analog continuous-wave two-tone (CWTT) frequency reference technique in both static and dynamic settings.

Clock synchronization↗

Solid-phase heteroepitaxy of oriented Sb 2 Se 3 on GaAs for birefringent thin films

Here, we investigate the amorphous-to-crystalline transformation of antimony selenide (Sb 2 Se 3 ) on UHV-prepared GaAs (001) substrates. In the bulk orthorhombic form, Sb 2 Se 3 is a layered quasi-1D semiconductor with highly anisotropic properties of interest for optical and electronic devices. We find that an amorphous layer deposited by molecular beam epitaxy annealed at or above 230 °C yields a textured-epitaxial structure among some randomly oriented domains. The textured-epitaxial Sb 2 Se 3 grains are oriented with the covalently bonded “1D axis” constrained in-plane to GaAs [110] and with multiple van der Waals (hk0) orientations out-of-plane. The same texture was achieved exclusively without randomly oriented grains using continuous-wave laser radiation, highlighting the use of thermal and optical methods to yield anisotropic crystalline Sb 2 Se 3 films directly from the amorphous phase. Polarized reflectance and polarized microscopy confirm the unique state of in-plane birefringence in the crystallized thin film. Overall, we show that solid-phase heteroepitaxy provides additional pathways to the integration of low-symmetry chalcogenide semiconductors for demanding applications where the inherent anisotropy needs to be preserved.

Xiao, Kelly [Stanford Univ., CA (United States)] (↗

Pulsed radio frequency power modulation for profile control in cryogenic reactive ion etching of silicon gratings

Cryogenic silicon etching with SF 6 /O 2 plasmas enables vertical sidewalls and smooth surfaces for high–aspect-ratio structures, yet precise control of etched profiles (sidewall angle, lateral etching, and linewidth retention) remains challenging under continuous-wave excitation due to coupling among radical fluxes, ion energy distributions, and in situ passivation dynamics. In this work, we investigated pulsed radio frequency bias delivery as a process knob for profile control during cryogenic silicon etching. Systematic experiments on 500 nm-wide, 1 μm-pitch gratings etched to 0.8–1.1 μm depth at 0.5–2 kHz pulsing frequency and 25%–75% duty cycle revealed strong dependencies of etch rate, linewidth, and sidewall angle on modulation conditions. We proposed a conceptual kinetic picture combined with feature-scale electrostatic analysis to understand the alternation of ion-driven etching and passivation recovery between on/off segments and local electric field shaping and modulation of ion trajectories within the trench. Moderate duty cycles (50%–75%) near 1 kHz achieved a balance between anisotropy and etch rate. These results demonstrate pulsed-bias modulation can be utilized to tune directionality and sidewall preservation in cryogenic SF 6 /O 2 etching, which are relevant to photonic, metrology, and quantum device fabrication.

36 MATERIALS SCIENCE↗

High-$Q_0$ treatment of CEBAF 1.5 GHz SRF cavities

The Continuous Electron Beam Accelerator Facility (CEBAF) was the first large-scale accelerator to employ superconducting radiofrequency (SRF) cavities for continuous-wave operation. Ongoing research and development efforts continue to focus on increasing the intrinsic quality factor (Q 0 ) of these cavities in order to reduce cryogenic losses while maintaining operational gradients. Here, in this work, we report on the application of high-Q 0 surface treatments to single-cell and multicell C100 and C75 style 1.5 GHz niobium cavities used in the CEBAF accelerator. Nitrogen infusion and oxygen alloying via medium-temperature baking were applied under heat-treatment constraints relevant to existing cavity hardware. Both processes yielded substantial improvements in Q 0 at moderate accelerating gradients, achieving values of approximately 2 × 10 10 at 2.07 K and 20 MV/m. The effectiveness of nitrogen infusion at reduced annealing temperatures and the successful extension of oxygen alloying to multicell cavities are demonstrated. These results establish viable pathways for implementing high-Q 0 treatments in CEBAF-compatible cavities and support future integration into cryomodules for reduced operational cryogenic load.

Dhakal, Pashupati [Thomas Jefferson National Accel↗