At least 19 records

Ethanol-Induced Condensation and Decondensation in DNA-Linked Nanoparticles: A Nucleosome-like Model for the Condensed State

Inspired by the conventional use of ethanol to induce DNA precipitation, ethanol condensation has been applied as a routine method to dynamically tune “bond” lengths (i.e., the surface-to-surface distances between adjacent nanoparticles that are linked by DNA) and thermal stabilities of colloidal crystals involving DNA-linked nanoparticles. However, the underlying mechanism of how the DNA bond that links gold nanoparticles changes in this class of colloidal crystals in response to ethanol remains unclear. Here, we conducted a series of all-atom molecular dynamic (MD) simulations to explore the free energy landscape for DNA condensation and decondensation. Our simulations confirm that DNA condensation is energetically much more favorable under 80% ethanol conditions than in pure water, as a result of ethanol’s role in enhancing electrostatic interactions between oppositely charged species. Moreover, the condensed DNA adopts B-form in pure water and A-form in 80% ethanol, which indicates that the higher-order transition does not affect DNA’s conformational preferences. We further propose a nucleosome-like supercoiled model for the DNA condensed state, and we show that the DNA end-to-end distance derived from this model matches the experimentally measured DNA bond length of about 3 nm in the fully condensed state for DNA where the measured length is 16 nm in water. Altogether, this study provides an atomistic understanding of the mechanism underlying ethanol-induced condensation and water-induced decondensation, while our proposed nucleosome-like model allows the design of new strategies for interpreting experimental studies of DNA condensation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantifying structural errors in cloud condensation nuclei activity from reduced representation of aerosol size distributions

Aerosol effects on clouds and radiation are the dominant contribution to uncertainty in radiative forcing relative to the pre-industrial atmosphere. While previous studies have assessed the impact of parametric uncertainty on modeled forcing, structural errors from the numerical representation of particle distributions have not been well quantified. Here we present a framework for quantifying error in aerosol size distributions and cloud condensation nuclei activity, which we apply to the widely used 4-mode version of the Modal Aerosol Module (MAM4). Box model predictions from the MAM4 are evaluated against the Particle Monte Carlo Model for Simulating Aerosol Interactions and Chemistry (PartMC-MOSAIC), a benchmark model that tracks the evolution of individual particles. We show that size distributions simulated by MAM4 diverge from those simulated by PartMC-MOSAIC after only a few hours of aging by condensation and coagulation in polluted conditions, which leads to large errors in modeled cloud condensation nuclei concentrations. We find that differences between MAM4 and PartMC-MOSAIC are largest under polluted conditions, where the size distribution evolves rapidly though aging by condensation of semi-volatile substances and coagulation among particles. These findings suggest that structural error in modeled aerosol properties contributes to the large inter-model variability in aerosol radiative forcing.

Fierce, Laura M.↗

Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen (N)—a noncondensable gas (NCG), simulating air in the reactor containment—to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted—utilizing iterative and nodalized mass and heat transfer calculation—to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results—a ratio of experimental and Nusselt’s theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen--a noncondensable gas (NCG), simulating air in the reactor containment--to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted--utilizing iterative and nodalized mass and heat transfer calculation to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results--a ratio of experimental and Nusselt's theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Condensation heat transfer in rotating heat pipes in the presence of a non-condensable gas

An analysis of condensation problems in rotating heat pipes containing vapors with different concentrations of non-condensable gases is given. In situations such as this, temperature and concentration gradients are set up in the vapor-gas mixture. There is a transport of mass due to temperature gradients accompanied by an energy transport phenomena due to a concentration gradient. A Nusselt type analysis is not suited to this type of problem; however, a boundary layer type approach has successfully been used to analyze stationary condensation systems with non-condensable gases present. The present boundary layer analysis is presented for condensation processes on the inside of a rotating heat pipe in the presence of non-condensable gases.

Daniels, T. C.↗

Homogeneous condensation of gaseous mixtures of Si, Fe, O, N, and C in relative cosmic abundance and implications for astronomical condensation

The pressure versus temperature curves for homogeneous nucleation and condensation of two gaseous mixtures with nearly relative solar abundance of Si, Fe, O, N, and C in an excess of H were determined experimentally. Mixtures of CO, Fe(CO)5, H2, SiH4, and N2O in Ar were heated behind reflected shocks in a shock tube. The nucleation and condensation, which took place in the subsequent gas-dynamic expansion (cooling phase), was monitored by light scattering and turbidity. Grain morphologies and crystalline phases present in the condensates were determined by electron microscopy. These data cast doubt on the validity of both equilibrium and classical nucleation theoretical approaches to predict homogeneous condensation in a solar nebula or stellar atmosphere.

Stephens, J. R.↗

Identification of 2-Hydroxyacyl-CoA Synthases with High Acyloin Condensation Activity for Orthogonal One-Carbon Bioconversion

One-carbon (C1) compounds are emerging as cost-effective and potentially carbon-negative feedstocks for biomanufacturing, which require efficient, versatile metabolic platforms for the synthesis of value-added products. Synthetic formyl-CoA elongation (FORCE) pathways allow diverse product synthesis from C1 compounds via iterative C1 elongation, operating independently from the host metabolism with reduced engineering complexity and improved theoretical yields. However, a major bottleneck was identified as the suboptimal kinetics of the core C1–C1 condensation enzyme, 2-hydroxyacyl-CoA synthase (HACS), catalyzing the acyloin condensation reaction between formaldehyde and formyl-CoA. Furthermore, we used a combinatorial approach of bioprospecting and rational protein engineering to identify multiple HACS variants with significantly improved activities toward C1 substrates. Sequence and structure alignment of the active variants elucidated the key regions for the catalytic function, which were targeted for mutagenesis, leading to improved catalytic efficiency. In parallel, a consecutive round of bioprospecting for homologs with high similarity with active variants revealed a highly active HACS variant exhibiting up to 7-fold improvement in catalytic efficiency (k cat /K M ) and 14-fold improvement in the FORCE pathway flux in vivo compared to the previous reports. Upon further optimization of the downstream pathway, the orthogonal C1-to-product bioconversion system showed a metabolic flux of up to 700 μM glycolate OD –1 h –1 (2.1 mmol gDCW –1 h –1 ) and an industrially relevant glycolate titer, rate, and yield of 5.2 g L –1 (67.8 mM), 0.22 g L –1 h –1 , and 94% carbon yield, respectively.

2-hydroxyacyl-CoA synthase↗

Multistage Condensation Pathway Minimizes Hysteresis in Water Harvesting with Large-Pore Metal–Organic Frameworks

Metal-organic frameworks (MOFs) have emerged as promising materials for atmospheric water harvesting (AWH). Large-pore MOFs provide high water capacity, but their significant hysteresis between sorption and desorption makes them unsuitable for AWH. Co2Cl2(BTDD) is a noteworthy exception. This MOF has large, 2.2 nm diameter one-dimensional pores, and combines both record-high water capacity and minimal hysteresis, making it an excellent material for water capture in arid areas. Sorption reversibility in Co2Cl2(BTDD) has been attributed to continuous water uptake. However, the sharp adsorption/desorption in the isotherms supports a discontinuous first-order transition. Here we use molecular simulations to compute the water adsorption and desorption pathways and isotherms in a Co2Cl2(BTDD) model, to elucidate how does this MOF achieve reversibility despite its large pore size. The simulations reveal a multi-stage mechanism of discontinuous water uptake facilitated by spatial segregation of rows of hydrophilic metal sites bridged by ~1 nm hydrophobic ligands. The multi-stage mechanism breaks the barrier of capillary condensation into smaller, easier to surmount ones, resulting in a facile process despite the sharp density discontinuity between confined liquid and vapor. Our results explain why exchanging Co2+ for Ni2+ or Clfor F- in the MOF have minimal impact on the condensation and desorption pressures. On the other hand, we predict that a decrease in hydrophilicity of the MOF vertices would strongly increase the hysteresis. We expect that the relationships between spatial distribution of hydrophilic sites and hysteresis unraveled in this study assist the design of water harvesting materials with maximal capacity and reversibility.

Zaragoza, Alberto↗

Giant Cloud Condensation Nuclei Facilitate Drizzle Formation in Stratocumulus—Insights From a Combined Observation‐Modeling Framework

The mechanism for initiating drizzle drop remains a gap in the current understanding of warm rain formation. One prevalent hypothesis suggests that the presence of Giant Cloud Condensation Nuclei (GCCN) generates drizzle‐sized drops necessary to trigger the Collision‐Coalescence (C‐C) process. Here, in this study, this hypothesis is investigated using a novel framework that integrates in situ observations, remote sensing measurements, and idealized models. Results show that GCCN can efficiently generate drizzle drops through condensation, producing a broad Droplet Size Distribution (DSD) comparable to in situ observations. The large drizzle drop and broad DSD strongly facilitate C‐C, further accelerating drizzle initiation. To compare with observation, the model‐generated DSDs are used to generate radar Doppler spectra where radar reflectivity and Doppler skewness is estimated. The simulated radar quantities correspond well with radar observations, providing critical evidence for the GCCN‐induced drizzle initiation mechanism.

54 ENVIRONMENTAL SCIENCES↗

Sub-two-cycle gigawatt-peak-power LWIR OPA for ultrafast nonlinear spectroscopy of condensed state materials

The application of high-power, few-cycle, long-wave infrared (LWIR, 8–20 µm) pulses in strong-field physics is largely unexplored due to the lack of suitable sources. However, the generation of intense pulses with >6 µm wavelength range is becoming increasingly feasible with the recent advances in high-power ultrashort lasers in the middle-infrared range that can serve as a pump for optical parametric amplifiers (OPA). Here we experimentally demonstrate the feasibility of this approach by building an OPA pumped at 2.4 µm that generates 93 µJ pulses at 9.5 µm, 1 kHz repetition rate with sub-two-cycle pulse duration, 1.6 GW peak power, and excellent beam quality. The results open a wide range of applications in attosecond physics (especially for studies of condensed phase samples), remote sensing, and biophotonics.

Leshchenko, Vyacheslav (ORCID:0000000199708559)↗

Condensation of anhydrides or dicarboxylic acids with compounds containing active methylene groups. Part 19: Condensation of phthalic and substituted phthalic anhydrides with benzoylacetic ester

Phthalylbenzoylacetic ester and its nitro and halogen derivatives were prepared through condensation of phthalic anhydride, nitrophthalic anhydride, and phthalic halide anhydride with benzoylacetic ester in a solution of acetic anhydride and triethylamine. The condensation of hemipinic acid anhydride proceeds similarly, but under more drastic conditions. Derivatives of indan-1,3-dione are also formed, with a small yield, in the reaction of nitrophthalic anhydrides with benzoylacetic ester in the presence of increased quantities of triethylamine.

Rotberg, Y. T.↗

Dicarboxylic acid anhydride condensation with compounds containing active methylene groups. 4: Some 4-nitrophthalic anhydride condensation reactions

By 4-nitrophthalic anhydride condensation with acetoacetate in acetic anhydride and triethylamine solution with subsequent breakdown of the intermediate condensation product, 5-nitroindanedione-1,3 was obtained. A 4-nitrophthalic anhydride with acetic anhydride, according to reaction conditions, may yield two products: in the presence of potassium acetate and at high temperatures 4-(or 5-)-nitro-2-acetylbenzoic acid is formed: in the presence of triethylamine and at room temperature 5-( or 6-)-nitrophthalic acetic acid is isolated. A 4-nitrophthalic anhydride and malonic acid in pyridine solution according to temperature yield either 5-( or 6-)-nitrophthalic acetic acid or 4-(or 5-)-nitro-2-acetylbenzoic acid.

Oskaja, V.↗

Analysis of condensation on a horizontal cylinder with unknown wall temperature and comparison with the Nusselt model of film condensation

Theoretical analysis and numerical computations are performed to set forth a new model of film condensation on a horizontal cylinder. The model is more general than the well-known Nusselt model of film condensation and is designed to encompass all essential features of the Nusselt model. It is shown that a single parameter, constructed explicitly and without specification of the cylinder wall temperature, determines the degree of departure from the Nusselt model, which assumes a known and uniform wall temperature. It is also known that the Nusselt model is reached for very small, as well as very large, values of this parameter. In both limiting cases the cylinder wall temperature assumes a uniform distribution and the Nusselt model is approached. The maximum deviations between the two models is rather small for cases which are representative of cylinder dimensions, materials and conditions encountered in practice.

Bahrami, Parviz A.↗