Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computational algorithms: projection and interpolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NASA Computational Case Study SAR Data Processing: Ground-Range Projection

Radar technology is used extensively by NASA for remote sensing of the Earth and other Planetary bodies. In this case study, we learn about different computational concepts for processing radar data. In particular, we learn how to correct a slanted radar image by projecting it on the surface that was sensed by a radar instrument.

Synthetic Aperture Radar (SAR)↗

Observer Evaluation of a Metal Artifact Reduction Algorithm Applied to Head and Neck Cone Beam Computed Tomographic Images

Purpose and Objectives: To quantify, through an observer study, the reduction in metal artifacts on cone beam computed tomographic (CBCT) images using a projection-interpolation algorithm, on images containing metal artifacts from dental fillings and implants in patients treated for head and neck (H&N) cancer. Methods and Materials: An interpolation-substitution algorithm was applied to H&N CBCT images containing metal artifacts from dental fillings and implants. Image quality with respect to metal artifacts was evaluated subjectively and objectively. First, 6 independent radiation oncologists were asked to rank randomly sorted blinded images (before and after metal artifact reduction) using a 5-point rating scale (1 = severe artifacts; 5 = no artifacts). Second, the standard deviation of different regions of interest (ROI) within each image was calculated and compared with the mean rating scores. Results: The interpolation-substitution technique successfully reduced metal artifacts in 70% of the cases. From a total of 60 images from 15 H&N cancer patients undergoing image guided radiation therapy, the mean rating score on the uncorrected images was 2.3 ± 1.1, versus 3.3 ± 1.0 for the corrected images. The mean difference in ranking score between uncorrected and corrected images was 1.0 (95% confidence interval: 0.9-1.2, P<.05). The standard deviation of each ROI significantly decreased after artifact reduction (P<.01). Moreover, a negative correlation between the mean rating score for each image and the standard deviation of the oral cavity and bilateral cheeks was observed. Conclusion: The interpolation-substitution algorithm is efficient and effective for reducing metal artifacts caused by dental fillings and implants on CBCT images, as demonstrated by the statistically significant increase in observer image quality ranking and by the decrease in ROI standard deviation between uncorrected and corrected images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Remark on Algorithm 1012: Computing Projections with Large Datasets

In ACM TOMS Algorithm 1012, the DELAUNAYSPARSE software is given for performing Delaunay interpolation in medium to high dimensions. When extrapolating outside the convex hull of the training set, DELAUNAYSPARSE calls the nonnegative least squares solver DWNNLS to compute projections onto the convex hull. However, DWNNLS and many other available sum-of-squares optimization solvers were not intended for usage with many variable problems, which result from the large training sets that are typical in machine learning applications. Thus, a new PROJECT subroutine is given, based on the highly customizable quadratic program solver BQPD. This solution is shown to be as robust as DELAUNAYSPARSE for projection onto both synthetic and real-world datasets, where other available solvers frequently fail. Although it is intended as an update for DELAUNAYSPARSE, due to the difficulty and prevalence of the problem, this solution is likely to be of external interest as well.

97 MATHEMATICS AND COMPUTING↗

Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting

Purpose: X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). Methods: The CMCF method uses concurrently run MC CBCT scatter projection simulations that are a subset of the projection angles used in the projection set, P, to be corrected. The scattered photons reaching the detector in each MC simulation are simultaneously aggregated by an algorithm which computes the scatter detector response, S{sub MC}. S{sub MC} is fit to a function, S{sub F}, and if the fit of S{sub F} is within a specified goodness of fit (GOF), the simulations are terminated. The fit, S{sub F}, is then used to interpolate the scatter distribution over all pixel locations for every projection angle in the set P. The CMCF algorithm was tested using a frequency limited sum of sines and cosines as the fitting function on both simulated and measured data. The simulated data consisted of an anthropomorphic head and a pelvis phantom created from CT data, simulated with and without the use of a compensator. The measured data were a pelvis scan of a phantom and patient taken on an Elekta Synergy platform. The simulated data were used to evaluate various GOF metrics as well as determine a suitable fitness value. The simulated data were also used to quantitatively evaluate the image quality improvements provided by the CMCF method. A qualitative analysis was performed on the measured data by comparing the CMCF scatter corrected reconstruction to the original uncorrected and corrected by a constant scatter correction reconstruction, as well as a reconstruction created using a set of projections taken with a small cone angle. Results: Pearson’s correlation, r, proved to be a suitable GOF metric with strong correlation with the actual error of the scatter fit, S{sub F}. Fitting the scatter distribution to a limited sum of sine and cosine functions using a low-pass filtered fast Fourier transform provided a computationally efficient and accurate fit. The CMCF algorithm reduces the number of photon histories required by over four orders of magnitude. The simulated experiments showed that using a compensator reduced the computational time by a factor between 1.5 and 1.75. The scatter estimates for the simulated and measured data were computed between 35–93 s and 114–122 s, respectively, using 16 Intel Xeon cores (3.0 GHz). The CMCF scatter correction improved the contrast-to-noise ratio by 10%–50% and reduced the reconstruction error to under 3% for the simulated phantoms. Conclusions: The novel CMCF algorithm significantly reduces the computation time required to estimate the scatter distribution by reducing the statistical noise in the MC scatter estimate and limiting the number of projection angles that must be simulated. Using the scatter estimate provided by the CMCF algorithm to correct both simulated and real projection data showed improved reconstruction image quality.

60 APPLIED LIFE SCIENCES↗

Geometric processing of digital images of the planets

New procedures and software have been developed for geometric transformation of images to support digital cartography of the planets. The procedures involve the correction of spacecraft camera orientation of each image with the use of ground control and the transformation of each image to a Sinusoidal Equal-Area map projection with an algorithm which allows the number of transformation calculations to vary as the distortion varies within the image. When the distortion is low in an area of an image, few transformation computations are required, and most pixels can be interpolated. When distortion is extreme, the location of each pixel is computed. Mosaics are made of these images and stored as digital databases. Completed Sinusoidal databases may be used for digital analysis and registration with other spatial data. They may also be reproduced as published image maps by digitally transforming them to appropriate map projections.

Edwards, Kathleen↗

An Eulerian multimaterial framework for simulating high-explosive aquarium tests

Aquarium tests of cylindrical high-explosive charges provide optical data of the detonation front velocity and shape, propagation of the shock wave in the surrounding water, and expansion rates of the detonation products behind the front. Data from aquarium experiments is often used for calibration of reactive burn models based on phenomenological equations of state (EOS) and reaction rate laws. This paper presents a multimaterial numerical modeling framework to solve the 2D axisymmetric reactive Euler equations for high-explosive aquarium tests, in particular for ammonium nitrate - fuel oil (ANFO) explosives. An extension of the Ghost Fluid Method (GFM) is used to handle the dynamic material interfaces for the ANFO explosion products, the charge-confining material (polymethyl methacrylate PMMA), and the surrounding water. This study analyzes the sensitivity of calculations (both computational efficiency and numerical accuracy) to different algorithms for the material interface models including the original GFM versus Riemann solver-based strategies. A novel method for defining the left and right states in the interfacial Riemann problem eliminates the need for sorting or nodal interpolation during the projection along the material interface. Numerical tests indicate that populating the interface node values using the Riemann solution mitigate the overheating error observed in steady-state calculations. Solution convergence and computational efficiency are explored as a function of the spatial and temporal order of the schemes. Results from the computational model with analytical equations of state and fitted reaction rate parameters show very good quantitative agreement with experimentally observed detonation front velocity, reaction products expansion, and shock wave propagation in the surrounding water for a cylindrical ANFO charge encased in PMMA. Finally, the proposed modeling framework, in conjunction with experimental tests, provides a reliable tool to assess equations of state and reaction rate expressions for reactive burn models of confined high explosives.

42 ENGINEERING↗

Assessment of metal artifact reduction methods in pelvic CT

Purpose: Metal artifact reduction (MAR) produces images with improved quality potentially leading to confident and reliable clinical diagnosis and therapy planning. In this work, the authors evaluate the performance of five MAR techniques for the assessment of computed tomography images of patients with hip prostheses. Methods: Five MAR algorithms were evaluated using simulation and clinical studies. The algorithms included one-dimensional linear interpolation (LI) of the corrupted projection bins in the sinogram, two-dimensional interpolation (2D), a normalized metal artifact reduction (NMAR) technique, a metal deletion technique, and a maximum a posteriori completion (MAPC) approach. The algorithms were applied to ten simulated datasets as well as 30 clinical studies of patients with metallic hip implants. Qualitative evaluations were performed by two blinded experienced radiologists who ranked overall artifact severity and pelvic organ recognition for each algorithm by assigning scores from zero to five (zero indicating totally obscured organs with no structures identifiable and five indicating recognition with high confidence). Results: Simulation studies revealed that 2D, NMAR, and MAPC techniques performed almost equally well in all regions. LI falls behind the other approaches in terms of reducing dark streaking artifacts as well as preserving unaffected regions (p < 0.05). Visual assessment of clinical datasets revealed the superiority of NMAR and MAPC in the evaluated pelvic organs and in terms of overall image quality. Conclusions: Overall, all methods, except LI, performed equally well in artifact-free regions. Considering both clinical and simulation studies, 2D, NMAR, and MAPC seem to outperform the other techniques.

60 APPLIED LIFE SCIENCES↗

Fast Computational Algorithms for Partial Differential Equations and Uncertainty Quantifications

This project concerned the construction, testing and analysis of computational algorithms for solving parameterized and stochastic partial differential equations. The study and understanding of equations of this type is of fundamental importance in numerous engineering and scientific applications. Examples include simulation of plasma dynamics in models of electric propulsion and nuclear fusion, simulation of multiphase flows, such as the flow of water, gas and oil in reservoirs, and structural analysis of the dependence of structures on materials. Parametrization is used in such settings when properties of the models such as viscosity of fluids or electric resistivity of materials are not precisely understood and instead are treated as random variables. The resulting solutions are themselves random, and having such solutions will enable engineers to use probabilistic methods to assess the likelihood of events, for example, whether a pollutant in a liquid will exceed a limit, and to use such analyses to develop ways to ensure positive outcomes. Construction of accurate (high resolution) computational solutions is expensive, requiring significant computer time and computational resources, and there is need to reduce computational cost to make simulation useful and effective. The aim of the project was to construct algorithms to efficiently compute surrogate solutions to parameterized problems to allow for efficient and accurate simulation. The technical approach used focused on two related strategies, based on rank-reduction methods and reduced-order models. These methods construct surrogate solutions of parameter-dependent models by projection or interpolation into low-dimensional approximation spaces. Cost savings are achieved if the low-dimensional spaces can be identified and constructed efficiently and if the resulting low-dimensional algebraic systems can be solved cheaply. Accomplishments include: Theoretical and empirical demonstration of the effectiveness of fast multigrid solution strategies for computing low-rank representations of parameter-dependent solutions to discrete partial differential equations, including the first proof establishing so-called textbook convergence properties for low-rank methods. Development of efficient solution algorithms for solving nonlinear parameter-dependent partial differential equations used in models of fluid dynamics. Developent of efficient algorithms for low-rank representation of solutions of time-dependent simulations of fluid dynamics using multi-dimensional tensor representations of solutions.

97 MATHEMATICS AND COMPUTING↗

Super Resolution of Remote Sensing Images Using Edge-Directed Radial Basis Functions

Edge-Directed Radial Basis Functions (EDRBF) are used to compute super resolution(SR) image from a given set of low resolution (LR) images differing in subpixel shifts. The algorithm is tested on remote sensing images and compared for accuracy with other well-known algorithms such as Iterative Back Projection (IBP), Maximum Likelihood (ML) algorithm, interpolation of scattered points using Nearest Neighbor (NN) and Inversed Distance Weighted (IDW) interpolation, and Radial Basis Functin(RBF) . The accuracy of SR depends on various factors besides the algorithm (i) number of subpixel shifted LR images (ii) accuracy with which the LR shifts are estimated by registration algorithms (iii) and the targeted spatial resolution of SR. In our studies, the accuracy of EDRBF is compared with other algorithms keeping these factors constant. The algorithm has two steps: i) registration of low resolution images and (ii) estimating the pixels in High Resolution (HR) grid using EDRBF. Experiments are conducted by simulating LR images from a input HR image with different sub-pixel shifts. The reconstructed SR image is compared with input HR image to measure the accuracy of the algorithm using sum of squared errors (SSE). The algorithm has outperformed all of the algorithms mentioned above. The algorithm is robust and is not overly sensitive to the registration inaccuracies.

Mareboyana, Manohar M.↗

An algorithm for efficient metal artifact reductions in permanent seed implants

Purpose: In permanent seed implants, 60 to more than 100 small metal capsules are inserted in the prostate, creating artifacts in x-ray computed tomography (CT) imaging. The goal of this work is to develop an automatic method for metal artifact reduction (MAR) from small objects such as brachytherapy seeds for clinical applications. Methods: The approach for MAR is based on the interpolation of missing projections by directly using raw helical CT data (sinogram). First, an initial image is reconstructed from the raw CT data. Then, the metal objects segmented from the reconstructed image are reprojected back into the sinogram space to produce a metal-only sinogram. The Steger method is used to determine precisely the position and edges of the seed traces in the raw CT data. By combining the use of Steger detection and reprojections, the missing projections are detected and replaced by interpolation of non-missing neighboring projections. Results: In both phantom experiments and patient studies, the missing projections have been detected successfully and the artifacts caused by metallic objects have been substantially reduced. The performance of the algorithm has been quantified by comparing the uniformity between the uncorrected and the corrected phantom images. The results of the artifact reduction algorithm are indistinguishable from the true background value. Conclusions: An efficient algorithm for MAR in seed brachytherapy was developed. The test results obtained using raw helical CT data for both phantom and clinical cases have demonstrated that the proposed MAR method is capable of accurately detecting and correcting artifacts caused by a large number of very small metal objects (seeds) in sinogram space. This should enable a more accurate use of advanced brachytherapy dose calculations, such as Monte Carlo simulations.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-08: Investigation On Signal Detectability in Volumetric Cone Beam CT Images with Anatomical Background

Purpose: To investigate the slice direction dependent detectability in cone beam CT images with anatomical background. Methods: We generated 3D anatomical background images using breast anatomy model. To generate 3D breast anatomy, we filtered 3D Gaussian noise with a square root of 1/f{sup 3}, and then assigned the attenuation coefficient of glandular (0.8cm{sup −1}) and adipose (0.46 cm{sup −1}) tissues based on voxel values. Projections were acquired by forward projection, and quantum noise was added to the projection data. The projection data were reconstructed by FDK algorithm. We compared the detectability of a 3 mm spherical signal in the image reconstructed from four different backprojection Methods: Hanning weighted ramp filter with linear interpolation (RECON1), Hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON3), and ramp filter with Fourier interpolation (RECON4), respectively. We computed task SNR of the spherical signal in transverse and longitudinal planes using channelized Hotelling observer with Laguerre-Gauss channels. Results: Transverse plane has similar task SNR values for different backprojection methods, while longitudinal plane has a maximum task SNR value in RECON1. For all backprojection methods, longitudinal plane has higher task SNR than transverse plane. Conclusion: In this work, we investigated detectability for different slice direction in cone beam CT images with anatomical background. Longitudinal plane has a higher task SNR than transverse plane, and backprojection with hanning weighted ramp filter with linear interpolation method (i.e., RECON1) produced the highest task SNR among four different backprojection methods. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Programs(IITP-2015-R0346-15-1008) supervised by the IITP (Institute for Information & Communications Technology Promotion), Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the MSIP (2015R1C1A1A01052268) and framework of international cooperation program managed by NRF (NRF-2015K2A1A2067635).

60 APPLIED LIFE SCIENCES↗

Temporal and spectral imaging with micro-CT

Purpose: Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with dual source micro-CT. Methods: The approach entails a retrospectively gated dual energy scan with optimized filters and voltages, and a series of computational operations to reconstruct the data. Projection interpolation and five-dimensional bilateral filtration (three spatial dimensions + time + energy) are used to reduce noise and artifacts associated with retrospective gating. We reconstruct separate volumes corresponding to different cardiac phases and apply a linear transformation to decompose these volumes into components representing concentrations of water and iodine. Since the resulting material images are still compromised by noise, we improve their quality in an iterative process that minimizes the discrepancy between the original acquired projections and the projections predicted by the reconstructed volumes. The values in the voxels of each of the reconstructed volumes represent the coefficients of linear combinations of basis functions over time and energy. We have implemented the reconstruction algorithm on a graphics processing unit (GPU) with CUDA. We tested the utility of the technique in simulations and applied the technique in an in vivo scan of a C57BL/6 mouse injected with blood pool contrast agent at a dose of 0.01 ml/g body weight. Postreconstruction, at each cardiac phase in the iodine images, we segmented the left ventricle and computed its volume. Using the maximum and minimum volumes in the left ventricle, we calculated the stroke volume, the ejection fraction, and the cardiac output. Results: Our proposed method produces five-dimensional volumetric images that distinguish different materials at different points in time, and can be used to segment regions containing iodinated blood and compute measures of cardiac function. Conclusions: We believe this combined spectral and temporal imaging technique will be useful for future studies of cardiopulmonary disease in small animals.

60 APPLIED LIFE SCIENCES↗

TH-A-18C-04: Ultrafast Cone-Beam CT Scatter Correction with GPU-Based Monte Carlo Simulation

Purpose: Scatter artifacts severely degrade image quality of cone-beam CT (CBCT). We present an ultrafast scatter correction framework by using GPU-based Monte Carlo (MC) simulation and prior patient CT image, aiming at automatically finish the whole process including both scatter correction and reconstructions within 30 seconds. Methods: The method consists of six steps: 1) FDK reconstruction using raw projection data; 2) Rigid Registration of planning CT to the FDK results; 3) MC scatter calculation at sparse view angles using the planning CT; 4) Interpolation of the calculated scatter signals to other angles; 5) Removal of scatter from the raw projections; 6) FDK reconstruction using the scatter-corrected projections. In addition to using GPU to accelerate MC photon simulations, we also use a small number of photons and a down-sampled CT image in simulation to further reduce computation time. A novel denoising algorithm is used to eliminate MC scatter noise caused by low photon numbers. The method is validated on head-and-neck cases with simulated and clinical data. Results: We have studied impacts of photo histories, volume down sampling factors on the accuracy of scatter estimation. The Fourier analysis was conducted to show that scatter images calculated at 31 angles are sufficient to restore those at all angles with <0.1% error. For the simulated case with a resolution of 512×512×100, we simulated 10M photons per angle. The total computation time is 23.77 seconds on a Nvidia GTX Titan GPU. The scatter-induced shading/cupping artifacts are substantially reduced, and the average HU error of a region-of-interest is reduced from 75.9 to 19.0 HU. Similar results were found for a real patient case. Conclusion: A practical ultrafast MC-based CBCT scatter correction scheme is developed. The whole process of scatter correction and reconstruction is accomplished within 30 seconds. This study is supported in part by NIH (1R01CA154747-01), The Core Technology Research in Strategic Emerging Industry, Guangdong, China (2011A081402003)

60 APPLIED LIFE SCIENCES↗

Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach

Purpose: The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior–inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane voxel resolutions. Isotropic resolution is necessary for multiplanar display, but the commonly used interpolation operation blurs images. This paper presents a super-resolution (SR) reconstruction method to enhance 4D-CT resolution. Methods: The authors assume that the low-resolution images of different phases at the same position can be regarded as input “frames” to reconstruct high-resolution images. The SR technique is used to recover high-resolution images. Specifically, the Demons deformable registration algorithm is used to estimate the motion field between different “frames.” Then, the projection onto convex sets approach is implemented to reconstruct high-resolution lung images. Results: The performance of the SR algorithm is evaluated using both simulated and real datasets. Their method can generate clearer lung images and enhance image structure compared with cubic spline interpolation and back projection (BP) method. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 40.8% relative to cubic spline interpolation and 10.2% versus BP. Conclusions: A new algorithm has been developed to improve the resolution of 4D-CT. The algorithm outperforms the cubic spline interpolation and BP approaches by producing images with markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Block Krylov Subspace Methods for Functions of Matrices II: Modified Block FOM

We analyze an expansion of the generalized block Krylov subspace framework of [Electron. Trans. Numer. Anal., 47 (2017), pp. 100--126]. This expansion allows the use of low-rank modifications of the matrix projected onto the block Krylov subspace and contains, as special cases, the block GMRES method and the new block Radau--Arnoldi method. Within this general setting, we present results that extend the interpolation property from the nonblock case to a matrix polynomial interpolation property for the block case, and we relate the eigenvalues of the projected matrix to the latent roots of these matrix polynomials. Some error bounds for these modified block FOM methods for solving linear systems are presented. We then show how cospatial residuals can be preserved in the case of families of shifted linear block systems. This result is used to derive computationally practical restarted algorithms for block Krylov approximations that compute the action of a matrix function on a set of several vectors simultaneously. Finally, we prove some error bounds and present numerical results showing that two modifications of FOM, the block harmonic and the block Radau--Arnoldi methods for matrix functions, can significantly improve the convergence behavior.

97 MATHEMATICS AND COMPUTING↗

A reactant-coordinate-based approach to state-to-state differential cross sections for tetratomic reactions

A new algorithm is proposed to compute quantum mechanically state-to-state differential cross sections for reactions involving four atoms in full dimensionality. This algorithm, which is based on the propagation of an initial state specific wave packet exclusively in reactant coordinates, extracts the S-matrix elements in the product channel by first interpolating the time-dependent wave packet using a collocation method at selected time intervals on the product coordinate grid and then projecting out the contributions of all final product states. Here, this approach is efficient and accurate, particularly for reactions that are dominated by a product well or long-range interactions. Validation of this approach is demonstrated for the H 2 + OH → H + H 2 O reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heel effect adaptive flat field correction of digital x-ray detectors

Purpose: Anode heel effect renders large-scale background nonuniformities in digital radiographs. Conventional offset/gain calibration is performed at mono source-to-image distance (SID), and disregards the SID-dependent characteristic of heel effect. It results in a residual nonuniform background in the corrected radiographs when the SID settings for calibration and correction differ. In this work, the authors develop a robust and efficient computational method for digital x-ray detector gain correction adapted to SID-variant heel effect, without resorting to physical filters, phantoms, complicated heel effect models, or multiple-SID calibration and interpolation.Methods: The authors present the Duo-SID projection correction method. In our approach, conventional offset/gain calibrations are performed only twice, at the minimum and maximum SIDs of the system in typical clinical use. A fast iterative separation algorithm is devised to extract the detector gain and basis heel patterns from the min/max SID calibrations. The resultant detector gain is independent of SID, while the basis heel patterns are parameterized by the min- and max-SID. The heel pattern at any SID is obtained from the min-SID basis heel pattern via projection imaging principles. The system gain desired at a specific acquisition SID is then constructed using the projected heel pattern and detector gain map.Results: The method was evaluated for flat field and anatomical phantom image corrections. It demonstrated promising improvements over interpolation and conventional gain calibration/correction methods, lowering their correction errors by approximately 70% and 80%, respectively. The separation algorithm was able to extract the detector gain and heel patterns with less than 2% error, and the Duo-SID corrected images showed perceptually appealing uniform background across the detector.Conclusions: The Duo-SID correction method has substantially improved on conventional offset/gain corrections for digital x-ray imaging in an SID-variant environment. The technique is relatively simple, and can be easily incorporated into multiple-point gain calibration/correction techniques. It offers a potentially valuable tool for preprocessing digital x-ray images to boost image quality of mammography, chest and cardiac radiography, as well as automated computer aided diagnostic radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid exploration of curvilinear grids using direct volume rendering

Fast techniques for direct volume rendering over curvilinear grids of hexahedral cells are developed. This type of 3D grid is common in computational fluid dynamics and finite element analysis. Four new projection methods are presented and compared with each other and with previous methods for tetrahedral grids and rectilinear grids. All four methods use polygon-rendering hardware for speed. A simplified algorithm for visibility ordering, which is based on a combination of breadth-first and depth-first searches, is described. A new multi-pass blending method is described that reduces visual artifacts that are introduced by linear interpolation in hardware where exponential interpolation is needed. Multi-pass blending is of equal interest to hardware-oriented projection methods used on rectilinear grids. Visualization tools that permit rapid data banding and cycling through transfer functions, as well as region restrictions, are described.

Vangelder, Allen↗