Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “complex mixtures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quantitative comparison of combined gas chromatographic/mass spectrometric profiles of complex mixtures

The paper describes a method called HISLIB for automatic quantitative comparison of gas chromatographic/mass spectrometric (GC/MS) results obtained on complex mixtures of organic compounds. The method is based on comparing new mixtures to 'historical' libraries of previous results. Co-occurrence of components is determined by matching relative retention indices (RRIs) and mass spectra after background removal and resolution of overlapping GC components. Internal standards are used to quantify the relative concentrations of components. Applications of HISLIB include validation of analytical procedures to isolate complex mixtures; development of historical libraries which might include complete summaries of all past observations, compilations of controls, or any other selected subset of results; improvement of the quality of existing libraries of mass spectral data; and detection of differences in kind and/or amounts of individual components. Limitations of the method are mentioned along with causes of their occurrence.

Smith, D. H.↗

PyKrev: A Python Library for the Analysis of Complex Mixture FT-MS Data

In this study, we present PyKrev, a Python library for the analysis of complex mixture Fourier transform mass spectrometry (FT-MS) data. PyKrev is a comprehensive suite of tools for analysis and visualization of FT-MS data after formula assignment has been performed. These comprise formula manipulation and calculation of chemical properties, intersection analysis between multiple lists of formulas, calculation of chemical diversity, assignment of compound classes to formulas, multivariate analysis, and a variety of visualization tools producing van Krevelen diagrams, class histograms, PCA score, and loading plots, biplots, scree plots, and UpSet plots. The library is showcased through analysis of hot water green tea extracts and Scotch whisky FT-ion cyclotron resonance-MS data sets. PyKrev addresses the lack of a single, cohesive toolset for researchers to perform FT-MS analysis in the Python programming environment encompassing the most recent data analysis techniques used in the field.

47 OTHER INSTRUMENTATION↗

Nondispersive infrared analyzer for specific gases in complex mixtures

Analyzer identifies and measures particular diatomic or polyatomic gases in complex gas mixtures. Mixing of absorption effects on light energy passing through gases to photodetector produces a signal component that is related to the absorption caused by reference-gas component in unknown gas mixture.

Dimeff, J.↗

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) peak intensity normalization for complex mixture analyses

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) is a preferred technique for analyzing complex organic mixtures. Currently, there is no consensus normalization approach, nor an objective method for selecting one, for quantitative analyses of FT-ICR-MS data. We investigate a method to evaluate and score the amount of bias various normalization approaches introduce into the data. We evaluate the ability of the Statistical Procedure for the Analysis of Normalization Strategies (SPANS) to guide selection of appropriate normalization approaches for two different FT-ICR-MS datasets. Further, we test the robustness of SPANS results to changes in SPANS parameter values and assess the impact of using various normalization approaches on downstream statistical analyses. The normalization approach identified by SPANS differed for the two datasets. Normalization methods impacted the statistical significance of peaks differently, underscoring the importance of carefully evaluating potential methods. More consistent SPANS scores resulted when at least 120 significant peaks are used, where larger sets of peaks were obtained by increasing the p-value threshold. Interestingly, we show that Total Sum Scaling and highest peak normalization, used in previous studies, underperformed relative to SPANS-recommended normalization approaches. While there is no single, best normalization method for all datasets, SPANS provides a mechanism to identify an appropriate normalization method for analyzing FT-ICR-MS data quantitatively. As a result, the number of peaks used in the background distributions of SPANS contributes more significantly to the reproducibility of results than the p-value thresholds used to obtain those peaks.

47 OTHER INSTRUMENTATION↗

Final Technical Report: Transport of Complex Mixtures in Ion-Containing Polymer Membranes

Permselective ion-containing membranes are an integral component for many applications from water treatment, fuel cells, and solar fuels devices where the selective transport of molecules and ions is desired. In solar fuels devices, ion-containing polymer membranes are responsible for permitting selective transport of ions between electrodes to maintain overall charge neutrality yet limit transport of reaction products produced at the electrodes. While the transport of single solutes through such membranes has been fairly well described, binary and multicomponent transport is poorly understood due to the myriad of interactions that occur in these systems (i.e. between co-permeants and between permeants and the membrane). Solar fuels devices are just one example of an application where understanding the transport of multiple simultaneous species is critically important to improving device performance as product crossover leads to reductions in overall device performance. The objectives of this research was to improve our understanding of the complex array of factors that influence transport behavior of multiple solutes within ion-containing polymer membranes. This experimental project addressed the lack of fundamental understanding of multicomponent transport behavior by synthesizing ion exchange membranes with varied incorporation of comonomers (ionic and neutral moieties) to investigate fundamental relationships between membrane structure, membrane physiochemical properties, and transport behavior of solutes and complex solute mixtures through dense, hydrated membranes.

25 ENERGY STORAGE↗

Evaluations of an Enhanced Total Hydrocarbon Analyzer With Complex Mixtures of Volatile Organic Compounds

From the earliest manned missions, the volatile organic compound (VOC) content of spacecraft air has been a concern because of a much greater potential for contamination than air in most terrestrial settings. First, the volume of air is small compared to the mass of man- made materials comprising the interior furnishings of the spacecraft. These man-made materials offgas VOCs trapped during manufacture. Second, the nitrogen fraction of the air is recycled. Any VOCs not scrubbed out with charcoal filters or aqueous condensate (mainly water expired by the crew) will accumulate in the air. Third, the crew emits metabolic VOCs. Fourth, experimental payloads can also offgas or accidentally release a VOC; in fact a major organic constituent of the atmosphere is the disinfectant isopropanol released from swabs used in medical experiments.

Cross, John H.↗

Data-driven predictions of complex organic mixture permeation in polymer membranes

Membrane-based organic solvent separations are rapidly emerging as a promising class of technologies for enhancing the energy efficiency of existing separation and purification systems. Polymeric membranes have shown promise in the fractionation or splitting of complex mixtures of organic molecules such as crude oil. Determining the separation performance of a polymer membrane when challenged with a complex mixture has thus far occurred in an ad hoc manner, and methods to predict the performance based on mixture composition and polymer chemistry are unavailable. Here, we combine physics-informed machine learning algorithms (ML) and mass transport simulations to create an integrated predictive model for the separation of complex mixtures containing up to 400 components via any arbitrary linear polymer membrane. We experimentally demonstrate the effectiveness of the model by predicting the separation of two crude oils within 6-7% of the measurements. Integration of ML predictors of diffusion and sorption properties of molecules with transport simulators enables for the rapid screening of polymer membranes prior to physical experimentation for the separation of complex liquid mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermodynamic Calculations for Complex Chemical Mixtures

General computer program, CECTRP, developed for calculation of thermodynamic properties of complex mixtures with option to calculate transport properties of these mixtures. Free-energy minimization technique used in equilibrium calculation. Rigorous equations used in transport calculations. Program calculates equilibrium compositions and corresponding thermodynamic and transport properties of mixtures. CECTRP accommodates up to 24 reactants, 20 elements, and 600 products, 400 of which are condensed. Written in FORTRAN IV for any large computer system.

Mcbride, B. J.↗

PFAS remediation: Evaluating the infrared spectra of complex gaseous mixtures to determine the efficacy of thermal decomposition of PFAS

Due to their widespread production and known environmental contamination, the need for the detection and remediation of per- and polyfluoroalkyl substances (PFAS) has grown quickly. While destructive thermal treatment of PFAS at low temperatures (e.g., 200 to 500oC) is of interest due to lower energy and infrastructure requirements, the range of possible degradation products remains underexplored. To better understand the low temperature decomposition of PFAS species, we have coupled gas-phase infrared spectroscopy with a multivariate curve resolution (MCR) analysis and a database of high-resolution PFAS infrared reference spectra to detect and quantify a complex mixture resulting from potassium perfluorooctanesulfonate (PFOS-K) decomposition. Nine prevalent decomposition products (namely smaller perfluorocarbon species) are identified and quantified.

54 ENVIRONMENTAL SCIENCES↗