Prototype Supermarket Building Energy Model

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry reviews, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and the International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. However, the current set of commercial prototype building models does not include a supermarket building type, which is one of major building types defined in the Energy Information Administration’s Commercial Building Energy Consumption Survey. As part of an ongoing effort to expand the current Commercial Building Prototype Model suite, this report presents the procedure used to develop the prototype supermarket building model based on multiple studies as well as a previously developed reference building model. The final set of prototype models includes 60 models for different vintages of ASHRAE Standard 90.1 (i.e., 2004, 2007, 2010, and 2013) and for 15 ASHRAE climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Process for Defining Prototype Building Models: Courthouse Case Study for U.S. Commercial Energy

Buildings currently consume 36% of the world’s energy and contribute nearly 40% of CO 2 emissions. Many countries desire to generate virtual models of their nation’s buildings in order to coordinate research activities and inform market opportunities for a more sustainable built environment. The United States Department of Energy uses a suite of Commercial Prototype Building Models, which currently includes 16 building types and covers 80% of US commercial floorspace. Efforts are underway to expand this suite by developing prototype models for additional building types. In this paper, we outline a systematic approach to defining the building, collecting relevant information and creating a flexible model while doing so in the pragmatic context of a courthouse building. Informed by building design guides, databases, documented projects and inputs from courthouse design experts, we define a small, 69,324 ft 2 (6440 m 2 ), four-courtroom, low-rise courthouse as the prototype to represent an average-size courthouse in the US. We present building characteristics relevant for energy model development and provide the rationale for their selection. These details combined with climate- and construction-vintage-specific requirements for the building envelope and systems from building standards will be used for developing the courthouse model for the Commercial Prototype Building Models suite. The comprehensive information presented will also guide model modification to capture the dynamics of smaller or larger courthouses more accurately for building or system size-specific research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock™ 2024 Release 1 [SWR-19-33 and SWR-20-32]

ComStock™ is an NREL model of the U.S. commercial building stock. The model takes some building characteristics from the U.S. Department of Energy's (DOE's) Commercial Prototype Building Models and Commercial Reference Building. However, unlike many other building stock models, ComStock also combines these with a variety of additional public- and private-sector data sets. Collectively, this information provides high-fidelity building stock representation with a realistic diversity of building characteristics. This repository contains the source code used to build and execute ComStock models, including upgrade scenarios. In addition, the sampling of buildings characteristics used for the initial ComStock (V1.0) release is provided. The ComStock model is under active calibration and development, which is publicly visible on this repository. Execution of the ComStock workflow is managed through the buildstockbatch repository, a shared asset of ResStock™ and ComStock™ , specifically developed to scale to execution of tens of millions of simulations through multiple infrastructure providers. The dataset output from the initial ComStock (V1.0) release can be found at the accompanying ComStock data viewer website and additional information about ComStock found on the NREL Buildings Website. For more details about ongoing model development please consult the End Use Load Profiles website. ComStock is a direct result of the NREL residential stock modeling tool ResStock™ (recipient of a R&D100 award) and was inspired by the high-fidelity solar & storage adoption model dGen™. Additionally, this tool would not be possible without the decades of work undertaken by the OpenStudio® and EnergyPlus® visionaries and contributors, significant funding, feedback and support from the Los Angeles Department of Water and Power, and the Department of Energy's Building Technology Office ongoing support of and investment in building energy modeling software. is an analytic methodology for modeling the energy usage of the commercial building stock within the United States of America. The commercial building stock is represented through a sampling of complex probabilistic distributions of various features of interest for modeling energy usage within commercial buildings. Each sample from these distributions is converted into a building energy model based on the features of that specific sample. Each building energy model can be simulated as is, but additional changes can be made to the model through addition of energy conservation measures, component faults, or other desired alterations. The results of the simulations are then processed to provide insights for various stakeholders, including but not limited to policy makers, engineers, and marketers.

Horsey, Henry↗

Prototype Courthouse Building Energy Model: Building Characteristics and Energy Simulation Results

To coordinate commercial building energy research activities, the US Department of Energy uses a suite of commercial prototype building models, which includes 16 building types and covers 80% of US commercial floorspace. Efforts are underway to expand this suite by developing prototype models for additional building types, including a courthouse. Informed by building design guides, databases, documented projects, and personal communication with courthouse design experts, a 3-story, 4-courtroom, 69,324 ft 2 building was considered as the prototype courthouse to represent an average-sized courthouse in the United States. This report documents the building and system characteristics of the prototype courthouse model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. To verify the energy simulation results, energy use statistics of existing courthouses from different building database are also presented. Based on the simulated energy use, the site energy use intensity of the prototype courthouse ranged from 45 to 159 kBtu/ft 2 compared with the average energy use intensity of 94.7 kBtu/ft 2 for the courthouse building type in the 2012 Commercial Building Energy Consumption Survey (CBECS) Data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updated OpenStudio Small and Medium Office Prototype Models

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry review, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. Of these, the small, medium, and large office buildings take about 12% of total commercial building floor area.Currently, small, medium, and large office prototype building models have simplified, single space type, while other building types includes more detailed space types. As such, the office prototype could not be easily used to properly assess changes (i.e. measures applied) to difference spaces commonly found in an office. This work has added new space types to the small and medium office, with properties based on several vintages of ASHRAE Standard 90.1 in different climate zones, and compared energy use of these newly-improved models with that of the original models.

Im, Piljae↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

pnnl/simple-building-calculator

The Simple Building Calculator is a web application that estimates annual energy use using regression models that have been fit to simulation results for the DOE Commercial Prototype Building Models. The tool is a single-page application that will allow a user to rapidly analyze the impact of energy efficiency measures and design options on building performance. As it uses linear regression models rather than more complicated machine learning models or physics based simulation, the tool can deploy easily and run client-side.

Xu, Weili↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Buildings with Solar-Reflective Roofs and Walls and its Impact on Peak Power Demand

Buildings are a major consumer of electricity in the United States and a significant portion of the consumption comes from heating, ventilation, and air-conditioning (HVAC) applications. Passive cooling strategies in the building envelope help to reduce the energy consumption for HVAC as well as peak electricity demand. Although being one of the most cost-effective passive cooling strategies, modern reflective roofing and reflective exterior wall technology is not well documented for its impact on peak demand. This study utilized whole building energy simulations on residential and commercial building prototype models to quantify the impact of cool roofs and cool exterior walls. The analysis was performed in three climate zones with varying insulation levels and solar reflectances for roofs and exterior walls. For both the residential and commercial buildings, the baseline building had a roof solar reflectance value of 0.10 and an exterior wall solar reflectance value of 0.25. The results from the simulations show that roofs and exterior walls with higher reflectance values increase cooling energy savings but can also increase heating energy consumption. The impact of changes in solar reflectances was greater in buildings with low roof/wall insulation levels compared to roofs/walls with higher insulation levels. A baseline for the simulations was set with the roof and exterior wall solar reflectances set at 0.1 and 0.25, respectively and simulations having varying roof and exterior wall thermal resistances were compared to the baselines.

14 SOLAR ENERGY↗

An assessment of power flexibility from commercial building cooling systems in the United States

Understanding varying characteristics and aggregate potential of power flexibility from different building types considering regional diversity is critically important to actively engaging building resources in future eco-friendly, low-cost, and sustainable power systems. This paper presents a comprehensive characteristics analysis and potential assessment of the power flexibility from heating, ventilation, and air conditioning (HVAC) loads in commercial buildings in the U.S. using a simulation-based method. In this method, commercial buildings are first grouped by building types and climate regions. The U.S. Department of Energy Commercial Prototype Building Models are used to represent an average building in each group and are simulated to characterize corresponding power flexibility. Based on building survey data, the number of commercial buildings in each group is estimated and used to calculate aggregate power flexibility. It is found that HVAC loads in commercial buildings offer more flexibility for increasing power consumption than for decreasing it. The power consumption of commercial buildings in the U.S. can be increased by 46 GW and decreased by 40 GW on peak summer days. Among all commercial building types, standalone retail buildings provide the most absolute flexibility while the medium office buildings have the most flexibility as a percentage of the rated power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Nationwide Energy Saving Potential Evaluation for Office Buildings with Occupant-Based Building Controls

The heating ventilation and air-conditioning (HVAC) system is a major contributor to building energy consumption. This paper aims to quantify the nationwide energy savings potential of implementing the occupancy-based control (OBC) for the HVAC system in typical medium-sized office buildings using a whole building simulation program (i.e., EnergyPlus). First, the medium-sized office from the DOE Commercial Prototype Building Models was modified to have detailed layout and space functions. Then, a statistic-algorithm-based tool was used to generate the dynamic occupancy schedules for various rooms. Next, both a baseline case and two OBC cases were created for the comparison based on the updated ASHRAE Standard 90.1 and ASHRAE Guideline 36. The HVAC operation in the baseline case follows a static occupancy schedule and fixed setpoint schedules for both room air temperatures and minimal system outside air flowrates, while the proposed OBC cases use the room temperature reset, system minimum outdoor airflow reset, and zone minimal supply airflow rate reset. These cases were extended to five climate zones in the United States to further quantify the energy savings potential associated with the OBC on a nationwide scale. The preliminary result of this case study shows that there could be significant energy savings potential from the proposed OBC strategies in medium-sized office buildings in the United States.

Pang, Zhihong↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systematic approach to define a prototype building model: Convenience Store

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities, continuous efforts have been made to convert 30 prototype building models, which cover 80% of commercial building floor space in the United States, into OpenStudio Standards prototype buildings. In this paper, we provide a systematic approach to define the building and system characteristics of a convenience store, which has the largest energy use intensity among the commercial building types not covered by current prototype models. This study will be used as a basis for developing the prototype convenience store building model.

Yoon, Yeobeom↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗