Engineering PapersSearch

SEARCH · Engineering Papers

Results for “comfort”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response

Assessing thermal comfort and participation in residential demand flexibility programs

Residential space-conditioning-based demand flexibility (DF) has become an increasingly sought-after method for demand-side load management to enhance grid reliability and facilitate integration of renewable energy generation. However, predicting the effectiveness and flexibility of residential DF resources is challenging due to the variability in household energy use behaviors. Current estimates show that only 50 % of projected savings from DF resources are actualized due to regulatory, technological, and social barriers. From a household perspective, concerns over thermal comfort during space conditioning-based DF events significantly impact participation decisions. Currently, there is a very limited understanding of how thermal comfort during space-conditioning-based DF events in real-world settings impacts household energy use behaviors and, consequently, the success of DF programs in achieving targeted savings. This paper proposes a method to comprehensively assess the thermal comfort implications of DF strategies and presents results of their impacts on DF event participation decisions and demand savings. Here, the proposed method was applied to a heat pump DF field study in Cordova, Alaska. The study’s key findings are: 1) DF event setpoint offsets that maintain indoor operative temperatures between 18 to 22 °C (65 to 71°F) may be preferred in Cordova, Alaska; 2) Household-level thermal comfort is more sensitive to the duration of the DF event than to the degree of temperature offset from baseline conditions; 3) The delayed impact of changes in indoor operative temperature in response to setpoint offsets, both during and after a DF event, influences occupants’ thermal comfort perceptions and willingness to persistently participate in events. The findings from application of the proposed method can help inform future larger-scale occupant-centric DF programs as it can capture information not readily available through utility and device-level energy use data. Thus, it can supplement these sources and help program administrators develop occupant-centric DF strategies, enabling more accurate predictions of participation rates and savings estimates for space-conditioning-based DF programs.

Demand side management

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun

Multitarget control models for building thermal comfort and indoor air quality - A critical review

The control techniques in buildings contribute significantly to thermal comfort and indoor air quality (IAQ). However, the gaps are existing for multitarget controls considering both thermal comfort and IAQ. They are: (1) both experimental and modeling control studies were conducted for thermal comfort, focusing on temperature and humidity. (2) All three (physical, grey-box, black-box) modeling approaches were investigated for temperature control. (3) Physical and grey-box modeling approach were adopted for humidity control. (4) physical models were developed for VOCs and CO2 control. (5) grey-box and black-box models were lacking for VOCs and CO2. (6) Multi-target controls were lacking for temperature, humidity and CO2s. (7) Limited studies are available for multi-target controls for temperature, humidity, and VOCs. (8) Multi-target controls are not available yet for temperature, humidity, VOCs, and CO2.

42 ENGINEERING

Reinforcement Learning Control for Buildings Co-Optimizing Energy, Comfort, and Indoor Air Quality: An Annual Assessment

Efficient control of Heating, Ventilation, and Air Conditioning (HVAC) systems is crucial for optimizing energy use and maintaining indoor comfort in buildings. Traditional control methods, such as PID control, cannot handle energy use trade-offs among multiple components in the building energy system at a supervisory level. Reinforcement learning (RL) presents a promising solution, offering adaptive and data-driven control strategies that optimize performance over time. However, RL also faces several challenges, including the conflicts encountered in co-optimizing energy savings, occupant comfort, and indoor air quality, and the requirement for extensive interactions with the environment in training. We proposed a flexible simulation platform that integrates a hybrid model for RL training and designed an RL agent to control the entire central HVAC system, focusing on co-optimizing energy consumption, thermal comfort, and indoor air quality ($\text{CO}_{2}$ and PM2.5 concentrations). Finally, we evaluated the RL agent's performance over an annual cycle. Our findings indicate that the RL agent can effectively manage the HVAC system with 14.7 % energy savings annually and balance multiple objectives, which demonstrates significant potential for improving HVAC system control and sustainability in buildings.

Guo, Fangzhou

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Comfort and Safety Metrics to Evaluate Customer Centric Resilience Enhancement Strategies

As the coincident events of extreme weather and major power outages continue to rise there is an increased need to implement resilience solutions. Many of these solutions are customer-centric, requiring the flexibility of demand, and many of the standard economic evaluations of these solutions do not include the benefits of resilience that are not easily quantified and monetized. Indoor air temperature has a large impact on the comfort and safety of building occupants during an extreme weather event. This work proposes metrics that can be used to compare the performance of resilience solutions in the context of comfort and safety.

Cost benefit analysis, Demand Side Management, Pow

Hot, Cold, or Just Right? Using a Wide-View Infrared Biometric Sensor to Improve Occupant Comfort and Reduce Overcooling in Buildings via Closed-loop Control (CRADA Final Report)

This research adds to the understanding of building energy management by fundamentally challenging the long-standing paradigm of controlling an environmental parameter—air temperature—and assuming occupant comfort will follow. The project developed and demonstrated a novel approach that directly senses physiological indicators of human comfort to enable closedloop, human-centric control of heating, ventilation, and air conditioning (HVAC) systems. This work shifts the focus from open-loop environmental control to a closed-loop system that prioritizes the occupants' actual thermal state. The primary benefit to the public is the potential for a simultaneous improvement in the quality of indoor environments, where people spend most of their time, and a significant reduction in national energy consumption. Overcooling, or the overuse of cooling energy in a way that discomforts occupants, wastes approximately 0.5 Quads of primary energy annually in U.S. commercial buildings and creates unproductive indoor environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

WRF-Comfort: simulating microscale variability in outdoor heat stress at the city scale with a mesoscale model

Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.

Geology

Proactive and Reactive Thermal Comfort Behaviors

The expansion of renewable electricity generation, growing demands due to electrification, greater prevalence of working from home, and increasing frequency and severity of extreme weather events, will place new demands on the electric supply and distribution grid. Broader adoption of demand response programs (DRPs) for the residential sector may help meet these challenges; however, experience shows that occupant overrides in DRPs compromises their effectiveness. There is a lack of formal understanding of how discomfort, routines, and other motivations affect DRP overrides and other related human building interactions (HBI). This paper reports preliminary findings from a study of 20 households in Colorado and Massachusetts, US over three months. Participants responded to ecological momentary assessments (EMA) triggered by thermostat interactions and at random times throughout the day. EMAs included Likert-scale questions of thermal preference, preference intensity, and changes to 7 different activity types that could affect thermal comfort, and an opened ended question about motivations of such actions. Twelve tags were developed to categorize motivation responses and analyzed statistically to identify associations between motivations, preferences, and HBI actions. Reactions to changes in the thermal environment were the most frequently observed motivation (118 of 220 responses). On the other hand, almost half (47%) responses were at least partially motivated by non-thermal factors, suggesting limited utility for occupant behavior models founded solely on thermal comfort. Changes in activity level and clothing were less likely to be reported when EMAs were triggered by thermostat interactions, while fan interactions were more likely. Windows, shades, and portable heater interactions had no significant dependence on how the EMA was triggered. These results suggest that better understanding of motivations for HBI may improve effectiveness of demand response programs.

Pathak, Maharshi

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Field and Laboratory Study to Characterize Fault Prevalence in Residential Comfort Systems

This report describes a project whose goal was to determine the prevalence of residential comfort system faults. The focus is on air conditioners and heat pumps, and on key faults that can occur during installation and have significant impacts on performance: (1) incorrect refrigerant charge level (undercharge or overcharge); (2) indoor coil airflow rate; (3) liquid line restrictions; (4) non-condensable gas in the refrigerant; and (5) duct leakage. In addition to quantifying fault prevalence, we collected metadata that could be studied to determine whether there are correlations that suggest drivers of fault prevalence, such as regional variations in practice, economic factors, climatic impacts, and others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

High-Fidelity Building Emulator for Integrated Comfort and Energy Analysis using EnergyPlus and Radiance

The growing need for smart, energy-efficient, and occupant-centric buildings has created a demand for advanced control systems that can optimize building operations to balance energy savings, demand flexibility, and comfort. However, current building energy simulation tools, such as EnergyPlus, have limitations that hinder the development and evaluation of these complex control systems. To address this challenge, we introduce a high-fidelity building emulator that dynamically couples EnergyPlus with Radiance for enhanced daylight modeling. The introduced workflow allows researchers and practitioners to rapidly develop and evaluate innovative control solutions. An example study looking at a south-facing office zone revealed up to 67% deviation in predicted light levels, which can significantly impact building assessment.

Yu, Tammie

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo