Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherent diffraction imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Bragg Coherent Diffraction Imaging for In Situ Studies in Electrocatalysis

Electrocatalysis is at the heart of a broad range of physicochemical applications that play an important role in the present and future of a sustainable economy. Among the myriad of different electrocatalysts used in this field, nanomaterials are of ubiquitous importance. An increased surface area/volume ratio compared to bulk makes nanoscale catalysts the preferred choice to perform electrocatalytic reactions. Bragg coherent diffraction imaging (BCDI) was introduced in 2006 and since has been applied to obtain 3D images of crystalline nanomaterials. BCDI provides information about the displacement field, which is directly related to strain. Lattice strain in the catalysts impacts their electronic configuration and, consequently, their binding energy with reaction intermediates. Even though there have been significant improvements since its birth, the fact that the experiments can only be performed at synchrotron facilities and its relatively low resolution to date (~10 nm spatial resolution) have prevented the popularization of this technique. Herein, we will briefly describe the fundamentals of the technique, including the electrocatalysis relevant information that we can extract from it. Subsequently, we review some of the computational experiments that complement the BCDI data for enhanced information extraction and improved understanding of the underlying nanoscale electrocatalytic processes. We next highlight success stories of BCDI applied to different electrochemical systems and in heterogeneous catalysis to show how the technique can contribute to future studies in electrocatalysis. Finally, we outline current challenges in spatiotemporal resolution limits of BCDI and provide our perspectives on recent developments in synchrotron facilities as well as the role of machine learning and artificial intelligence in addressing them.

bragg coherent diffraction imaging↗

Mapping the 3D position of battery cathode particles in Bragg coherent diffractive imaging

In Bragg coherent diffractive imaging, the precise location of the measured crystals in the interior of the sample is usually missing. Obtaining this information would help the study of the spatially dependent behavior of particles in the bulk of inhomogeneous samples, such as extra-thick battery cathodes. This work presents an approach to determine the 3D position of particles by precisely aligning them at the instrument axis of rotation. In the test experiment reported here, with a 60 µm-thick LiNi 0.5 Mn 1.5 O 4 battery cathode, the particles were located with a precision of 20 µm in the out-of-plane direction, and the in-plane coordinates were determined with a precision of 1 µm.

25 ENERGY STORAGE↗

Bragg coherent diffraction imaging by simultaneous reconstruction of multiple diffraction peaks

Bragg coherent diffractive imaging (BCDI) is a non-invasive microscopy technique that can visualize the morphology and internal lattice deviations of crystals with nanoscale spatial resolution and picometer deformation sensitivity. While BCDI has been successfully applied in various studies of materials, it is less successful for highly-strained crystals. Specifically, it is difficult to correctly reconstruct the electron density of a highly-strained object using conventional phase retrieval algorithms. Although various algorithms have been developed to overcome this challenge, most of them require a priori knowledge that is not always available in practice. Here we report on a new phase retrieval workflow that can invert diffraction patterns from multiple Bragg peaks simultaneously. The new workflow is explored via simulated diffraction from crystals with various strain conditions. Furthermore, reconstructions from the new workflow consistently demonstrate more accurate electron density maps, in comparison with the conventional method. For highly-strained crystals, the new workflow improves the reliability and consistency of BCDI phase retrieval significantly.

36 MATERIALS SCIENCE↗

Adaptively coupled phase retrieval in multi-peak Bragg coherent diffraction imaging

Recent advances in Bragg coherent diffraction imaging (BCDI) experimental techniques permit routine measurement of multiple Bragg peaks from a single crystalline grain. The resulting images contain the full lattice distortion vector field which can be differentiated to provide lattice strain and rotation. With the advent of fourth-generation synchrotron light sources, such multi-peak datasets are produced at high rates, facilitating the need for rapid phase retrieval of the multiple peaks and subsequent image analysis. Here we describe and demonstrate a new implementation of a coupled phase retrieval technique for multi-peak BCDI which simultaneously treats each Bragg peak of the dataset and produces a three-dimensional image of the crystal's morphology and lattice distortion field. In addition, this method uses the redundant information contained in the various Bragg diffraction patterns to detect and suppress spurious signal appearing on the detector in a subset of the measurements. Compared with manual data editing, adaptive coupling produces a more consistent phase profile in reciprocal space and sharper surfaces in direct space, with no significant difference in computational cost. These improvements reduce the need for manual preprocessing and enable robust high-throughput analysis of multi-peak BCDI data, supporting near-real-time strain microscopy at modern synchrotron facilities.

36 MATERIALS SCIENCE↗

Experimental demonstration of coupled multi-peak Bragg coherent diffraction imaging with genetic algorithms

Bragg coherent diffraction imaging has the potential to provide significant insight into the structure-properties relationship for crystalline materials by imaging, with nanoscale resolution, three-dimensional strain fields within individual grains and nanoparticles. The capability of present-day synchrotrons to locate and measure a multiplicity of Bragg reflections from a single grain makes it possible to recover the full strain tensor with nanometer resolution. Recent methods for coupling reconstructions from several peaks to determine the strain tensor have been developed and applied to synthetic data, but have not been applied to experimental data. Here, using a coupled genetic reconstruction algorithm, we reconstruct an experimental data set and demonstrate improvements in the ability to resolve vector-valued displacement fields internal to the particle as compared to what is achieved with a noncoupled approach. The coupled approach developed in this work was also validated on simulated data sets. In both simulated and experimental data, reconstructions from our coupled Bragg peak algorithm show improvements over the noncoupled independent reconstruction method of 5% in terms of accuracy and 53% in terms of consistency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Defect identification in simulated Bragg coherent diffraction imaging by automated AI

X-ray Bragg coherent diffraction imaging is a powerful technique for operando and in situ materials characterization and provides a unique means of quantifying the influence of one-dimensional (1D) and two-dimensional (2D) material defects on material response. However, obtaining full images from raw x-ray diffraction data is nontrivial and computationally intensive, precluding real-time experimental feedback. Here, we present a machine learning approach to identify the presence of crystalline line defects (edge and screw) in samples from the raw, 2D, coherent diffraction data without the need for image reconstruction through iterative phase retrieval. Further, we compare different approaches to designing neural networks for this application and demonstrate the potential of automated ML (autoML) approaches.

36 MATERIALS SCIENCE↗

Removal of spurious data in Bragg coherent diffraction imaging: an algorithm for automated data preprocessing

Bragg coherent diffraction imaging (BCDI) provides a powerful tool for obtaining high-resolution structural information from nanocrystalline materials. Here a BCDI sample consisting of a large number of randomly oriented nanoscale crystals is considered. Ideally, only one crystal is oriented to produce a Bragg peak on the detector. However, diffraction from other crystals often produces additional signals on the detector. Before the measured diffraction patterns can be processed into structural images, scientists routinely need to manually identify and remove the `alien' intensities from sources other than the intended crystal. With the development of modern high-coherence storage rings, such as the upgraded Advanced Photon Source (APS), the already slow process of manual preprocessing will be untenable for the large volumes of data that will be produced. An automated method of identifying and deleting alien intensities is proposed. This method exploits the fact that BCDI of a perfect crystal produces diffraction data with inversion symmetry around the Bragg peak. This approach uses the machine learning clustering method DBSCAN to distinguish between diffraction from multiple sources, and then calculates cluster size and inversion symmetry to assess whether clusters of intensity belong to desired data or alien signals. This approach can dramatically reduce the amount of time spent manually processing data, allowing BCDI data processing capabilities to keep pace with the technological advances of fourth-generation synchrotron light sources.

36 MATERIALS SCIENCE↗

Enabling dynamic 3D coherent diffraction imaging via adaptive latent space tuning of generative autoencoders

Abstract Coherent diffraction imaging (CDI) is an advanced non-destructive 3D X-ray imaging technique for measuring a sample’s electron density. The main challenge of CDI is loss of phase information in diffraction intensity measurements, resulting in lengthy iterative reconstruction processes that can return non-unique solutions, which pose challenges for experiments attempting to track dynamic sample evolution through multiple states. As the increased brightness of fourth-generation light sources enables faster sample measurements and drives operando experiments with Bragg CDI, there is a growing need for faster reconstruction techniques that can keep pace. We have developed an adaptive generative autoencoder approach for uniquely tracking a sample’s electron density as it dynamically evolves. Our approach adaptively tunes the low-dimensional latent embedding of a generative autoencoder, enabling a computationally efficient manner to account for time-varying shifting distributions in real-time. Analytic proof of convergence is provided as well as numerical demonstration of sample tracking with noisy measurements.

97 MATHEMATICS AND COMPUTING↗

Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. Herein, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

47 OTHER INSTRUMENTATION↗

Combining Laue diffraction with Bragg coherent diffraction imaging at 34-ID-C

Measurement modalities in Bragg coherent diffraction imaging (BCDI) rely on finding a signal from a single nanoscale crystal object which satisfies the Bragg condition among a large number of arbitrarily oriented nanocrystals. However, even when the signal from a single Bragg reflection with ( hkl ) Miller indices is found, the crystallographic axes on the retrieved three-dimensional (3D) image of the crystal remain unknown, and thus localizing in reciprocal space other Bragg reflections becomes time-consuming or requires good knowledge of the orientation of the crystal. Here, the commissioning of a movable double-bounce Si (111) monochromator at the 34-ID-C endstation of the Advanced Photon Source is reported, which aims at delivering multi-reflection BCDI as a standard tool in a single beamline instrument. The new instrument enables, through rapid switching from monochromatic to broadband (pink) beam, the use of Laue diffraction to determine crystal orientation. With a proper orientation matrix determined for the lattice, one can measure coherent diffraction patterns near multiple Bragg peaks, thus providing sufficient information to image the full strain tensor in 3D. The design, concept of operation, the developed procedures for indexing Laue patterns, and automated measuring of Bragg coherent diffraction data from multiple reflections of the same nanocrystal are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X‑ray Coherent Diffractive Imaging of Large Helium Nanodroplets Doped with Small Molecules

We report the first X-ray coherent diffractive imaging experiment on molecule-doped helium nanodroplets. It complements previous work, where we reported single-shot X-ray coherent diffractive imaging studies of Xe dopant clusters formed in 4He and 3He droplets. These noble gas clusters were used to visualize the impact of rotational excitation of the droplets on the spatial distribution of atomic dopants within the droplets, and to study the differences and connections between quantum and classical droplet rotational motion. Here, we expand our studies to the molecular dopants CF4, CHF3, CH3CN, and SF6, imaged with 1.5 keV photons. We find multiple Bragg spots in the diffraction patterns of molecule-doped droplets with radii of approximately 600 nm, which provide evidence that molecules form elongated clusters with preferential alignment along the angular momentum axis of the 4He droplets, in agreement with our previous results on the aggregation of Xe clusters on quantum vortices. Real-space reconstructions of molecular dopant cluster density profiles are obtained for droplets with smaller radii of approximately 300 nm. The diffuse images suggest the formation of low-density, potentially porous, molecular clusters upon aggregation at T = 0.4 K in 4He droplets. In the normal fluid 3He droplets, molecules aggregate into loose clusters on the droplets' equator, similar to previous observations for Xe atoms. Time-of-flight mass spectra reveal that the doped helium nanodroplet moieties fragment extensively into constituent atomic ions, producing only a small fraction of molecular fragment ions. The findings are discussed in the context of previously proposed schemes to use He droplets as potential tamper materials for ultrafast X-ray imaging experiments.

Feinberg, AlexandraJ↗

Detector Tilt Considerations in Bragg Coherent Diffraction Imaging: A Simulation Study

This paper addresses the three-dimensional signal distortion and image reconstruction issues in X-ray Bragg coherent diffraction imaging (BCDI) in the event of a general non-orthogonal orientation of the area detector with respect to the diffracted beam. Growing interest in novel BCDI adaptations at fourth-generation synchrotron light sources has necessitated improvisations in the experimental configuration and the subsequent data analysis. One such possibly unavoidable improvisation that is envisioned in this paper is a photon-counting area detector whose face is tilted away from the perpendicular to the Bragg-diffracted beam during the acquisition of the coherent diffraction signal. We describe a likely circumstance in which one would require such a detector configuration, along with the experimental precedent at third-generation synchrotrons. Using physically accurate diffraction simulations from synthetic scatterers in the presence of such tilted detectors, we analyze the general nature of the observed signal distortion qualitatively and quantitatively and provide a prescription to correct for it during image reconstruction. Our simulations and reconstructions are based on an adaptation of the known theory of BCDI sampling geometry, as well as the recently developed projection-based methods of wavefield propagation. Such configurational modifications and their numerical remedies are potentially valuable in realizing unconventional coherent diffraction measurement geometries, eventually paving the way for the integration of BCDI into new material characterization experiments at next-generation light sources.

36 MATERIALS SCIENCE↗

Potential of Attosecond Coherent Diffractive Imaging

Attosecond science has been transforming our understanding of electron dynamics in atoms, molecules, and solids. However, to date almost all of the attoscience experiments have been based on spectroscopic measurements because attosecond pulses have intrinsically very broad spectra due to the uncertainty principle and are incompatible with conventional imaging systems. In this paper we report an important advance towards achieving attosecond coherent diffractive imaging. Using simulated attosecond pulses, we simultaneously reconstruct the spectrum, 17 probes, and 17 spectral images of extended objects from a set of ptychographic diffraction patterns. We further confirm the principle and feasibility of this method by successfully performing a ptychographic coherent diffractive imaging experiment using a light-emitting diode with a broad spectrum. We believe this work clears the way to an unexplored domain of attosecond imaging science, which could have a far-reaching impact across different disciplines.

36 MATERIALS SCIENCE↗

Coherent diffraction imaging in the undergraduate laboratory

We present an undergraduate optics instructional laboratory designed to teach skills relevant to a broad range of modern scientific and technical careers. In this laboratory project, students image a custom aperture using coherent diffraction imaging, while learning principles and skills related to digital image processing and computational imaging, including multidimensional Fourier analysis, iterative phase retrieval, noise reduction, finite dynamic range, and sampling considerations. After briefly reviewing these imaging principles, we describe the required experimental materials and setup for this project. Our experimental apparatus is both inexpensive and portable, and a software application we developed for interactive data analysis is freely available.

Porter, J. Nicholas↗

Considerations for three-dimensional image reconstruction from experimental data in coherent diffractive imaging

The Datasets folder contains 3 datasets, corresponding to the datasets mentioned in the article with 670, 2691 and 586 images. The Runs folder has all the runs used. Besides the images itself it also contains tags for each image under `/entry_1/image_1/detector_and_photon_corrected/tags`. The `headings` attribute gives the name of each tag. The `Jonas Strict` tag corresponds to the 670 images, the `Redflamingo` tag to the 2691 images and the `Redflamingo_Ida_subset` tag to the 586 images. The final dataset with 260 images can be obtained from `Datasets/amoc6914-Redflamingo-manual-586.h5` and use the `/model/diameterNM` group to select the 260 images with size closest to 214 nm.

AMO↗

Adaptive 3D convolutional neural network-based reconstruction method for 3D coherent diffraction imaging

We present a novel adaptive machine-learning based approach for reconstructing three-dimensional (3D) crystals from coherent diffraction imaging. We represent the crystals using spherical harmonics (SH) and generate the corresponding synthetic diffraction patterns. We utilize 3D convolutional neural networks (CNNs) to learn a mapping between 3D diffraction volumes and the SH, which describe the boundary of the physical volumes from which they were generated. We use the 3D CNN-predicted SH coefficients as the initial guesses, which are then fine-tuned using adaptive model-independent feedback for improved accuracy. We also adaptively tune the locations, intensities, and decay rates of collections of radial basis functions in order to reproduce the non-uniform internal structure of 3D objects and demonstrate the method for a synthetic volume that has an internal void and a density ramp.

36 MATERIALS SCIENCE↗

NEURAL NETWORK FOR COHERENT DIFFRACTION IMAGE INVERSION

A deep neural network model plus automatic differentiation is developed for retrieving phase information from 3D coherent diffraction images. The model is implemented using Tensorflow and the training dataset is generated using physics-based atomistic simulations. Custom codes are written to handle the resampling of diffraction images to oversampling ratios appropriate for the neural network model.

CHAN, HENRY↗