Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “closed-loop control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An error criterion for determining sampling rates in closed-loop control systems

The determination of an error criterion which will give a sampling rate for adequate performance of linear, time-invariant closed-loop, discrete-data control systems was studied. The proper modelling of the closed-loop control system for characterization of the error behavior, and the determination of an absolute error definition for performance of the two commonly used holding devices are discussed. The definition of an adequate relative error criterion as a function of the sampling rate and the parameters characterizing the system is established along with the determination of sampling rates. The validity of the expressions for the sampling interval was confirmed by computer simulations. Their application solves the problem of making a first choice in the selection of sampling rates.

Brecher, S. M.↗

Experimental Evaluation of Steady-State Control Properties of an Electron-Bombardment Ion Thrustor

Examined in this report are the experimental steady-state gains, or changes, in beam-current output with changes in thrustor inputs for a 10-centimeter-diameter electron-bombardment ion thrustor. A general leveling off of beam current as a function of an input variable was found at the upper range of each variable, At the design operating point, the filament-heating current exhibited the greatest sensitivity, or percentage beam-current output change for a percentage change in the input (2 to 4). Accelerator voltage showed the least effect (0.04) while discharge voltage, magnetic field, and neutral propellant flow exhibited about the same sensitivity (0.4 to 0.5). Some effects of nonlinearity are shown that may require consideration in the design of a closed-loop control system.

CONTROL↗

Design concepts using ring lasers for frequency stabilization

Laser frequency stabilization methods are based on a frequency discriminant which generates an unambiguous deviation signal used for automatic stabilization. Closed-loop control stabilizes cavity length at a null point. Some systems have a stabilized ring laser using a piezoelectric dither and others use a Doppler gain tube.

Mocker, H.↗

Parabolic Deformable Mirror Project Development and Device Characterization

Existing state-of-the-art wavefront sensing and control setups for the imaging of exoplanets utilize two high-actuator count flat deformable mirrors (DMs) to control both phase and amplitude aberrations. One of the objectives of the Exoplanet Spectroscopy (ExoSpec) project at Goddard Space Flight Center (GSFC) is to improve upon this regime through the development of parabolic deformable mirrors (PDMs), which can address several of the key limitations in existing setups. Specifically, the need for flat DMs to be located in conjugate pupil planes drives unique packaging challenges that can be overcome by allowing the off-axis imaging elements to be controllable as well. In addition, simulations show that the use of deformable powered elements will increase the overall controllable bandwidth, up to 35% over 5-12 lambda/D. To pursue this effort, the ExoSpec group has begun testing a first-generation parabolic DM, which is already informing a second generation design. This paper will provide a comprehensive update on its characterization, including influence function measurements, linearity analysis, closed-loop wavefront control performance, and thermal stability assessment.

spectroscopy↗

Human transfer functions used to predict system performance parameters

Automatic, parameter-tracking, model-matching technique compares the responses of a human operator with those of an analog computer model of a human operator to predict and analyze the performance of mechanical or electromechanical systems prior to construction. Transfer functions represent the input-output relation of an operator controlling a closed-loop system.

Source record↗

Surveyor Project Final Report: Part 1 - Project Description and Performance, Volume 1

The Surveyor Project planned and conducted seven unmanned lunar missions for which spacecraft were launched between May 1966 and January 1968. Each of the spacecraft was successfully launched with the then newly developed Atlas/Centaur vehicle which utilized for the first time a high-specific-impulse, liquid hydrogen/liquid oxygen fueled stage. Five of the spacecraft successfully soft-landed and returned a great quantity of engineering and scientific data on extensive postlanding operations, accomplishing all mission and project objectives. Four of the spacecraft soft-landed at selected mare sites to provide data which were required to support the Apollo Program. The final spacecraft was then successfully used for scientific investigation of a contrasting site in the rugged lunar highlands. Surveyor was a fully attitude-stabilized spacecraft designed to receive and execute a wide variety of earth commands, as well as to perform certain automatic functions including the critical terminal-descent and soft-landing sequences. Significant new and advanced subsystems that were developed and/or used in combination to enable Surveyor to execute the complex terminal phase of flight were: (1) a solid-propellant main retro motor, (2) throttlable liquid-propellant vernier engines (also used for midcourse velocity correction), (3) highly sensitive velocity- and altitude-sensing radars, and (4) an automatic closed-loop guidance and control system. The first Surveyor spacecraft carried a survey television camera which, together with other engineering instrumentation, obtained in-flight and postlanding data. The complement of instruments carried on later missions included various combinations of the following additional devices: (1) a soil mechanics/surface sampler instrument for picking, digging, and handling lunar surface material; (2) an alpha scattering instrument for performing a chemical analysis of the lunar surface material; and (3) magnets attached to the spacecraft for determining magnetic properties of the soil.

Jet Propulsion Laboratory↗

Surveyor Project Final Report: Part 1 - Project Description and Performance, Volume 2

The Surveyor Project planned and conducted seven unmanned lunar missions for which spacecraft were launched between May 1966 and January 1968. Each of the spacecraft was successfully launched with the then newly developed Atlas/Centaur vehicle which utilized for the first time a high-specific-impulse, liquid hydrogen/liquid oxygen fueled stage. Five of the spacecraft successfully soft-landed and returned a great quantity of engineering and scientific data on extensive postlanding operations, accomplishing all mission and project objectives. Four of the spacecraft soft-landed at selected mare sites to provide data which were required to support the Apollo Program. The final spacecraft was then successfully used for scientific investigation of a contrasting site in the rugged lunar highlands. Surveyor was a fully attitude-stabilized spacecraft designed to receive and execute a wide variety of earth commands, as well as to perform certain automatic functions including the critical terminal-descent and soft-landing sequences. Significant new and advanced subsystems that were developed and/or used in combination to enable Surveyor to execute the complex terminal phase of flight were: (1) a solid-propellant main retro motor, (2) throttlable liquid-propellant vernier engines (also used for midcourse velocity correction), (3) highly sensitive velocity- and altitude-sensing radars, and (4) an automatic closed-loop guidance and control system. The first Surveyor spacecraft carried a survey television camera which, together with other engineering instrumentation, obtained in-flight and postlanding data. The complement of instruments carried on later missions included various combinations of the following additional devices: (1) a soil mechanics/surface sampler instrument for picking, digging, and handling lunar surface material; (2) an alpha scattering instrument for performing a chemical analysis of the lunar surface material; and (3) magnets attached to the spacecraft for determining magnetic properties of the soil.

Jet Propulsion Laboratory↗

A modal combination computer program for dynamic analysis of structures

Computer program determines the response of a composite linear structure to sinusoidal base motion of a restrained structure or sinusoidal forces of a free structure. This program is applied to problems of testing practices and closed-loop stability of autopilot controlled space vehicles. It is written for the IBM 7094 in FORTRAN 4 language.

Bamford, R. M.↗

Advanced scan platform

Open and closed-loop actuation and electronic control mechanism for advanced scan platform

SERVOACTUATOR↗

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell↗

Study of an Active Control System for a Spinning Body

The mission requirements for some satellites require that they spin continuously and at the same time maintain a precise direction of the spin axis. An analog-computer study has been made of an attitude control system which is suitable for such a satellite. The control system provides the necessary attitude control through the use of a spinning wheel, which will provide precession torques, commanded by an automatic closed-loop servomechanism system. The sensors used in the control loop are rate gyroscopes for damping of any wobble motion and a sun seeker for attitude control. The results of the study show that the controller can eliminate the wobble motion of the satellite resulting from a rectangular pulse moment disturbance and then return the spin axis to the reference space axis. The motion is damped to half amplitude in less than one cycle of the wobble motion. The controller can also reduce the motion resulting from a step change in product of inertia both by causing the new principal axis to be steadily alined with the spin vector and by reducing the cone angle generated by the reference body axis. These methods will reduce the motion whether the satellite is a disk, sphere, or rod configuration.

Adams, J. J.↗