Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cesium removal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Closed cycle MHD power generation experiments using a helium-cesium working fluid in the NASA Lewis Facility

A MHD channel, which was previously operated for over 500 hours of thermal operation, ten thermal cycles, and 200 cesium injection tests, was removed from the facility and redesigned. The cross sectional dimensions of the channel were reduced to 5 by 16.5 cm to allow operation over a variety of conditions. The redesigned channel has been operated for well over 300 hours, 10 thermal cycles, and 150 cesium injection tests with no problems. Experiments have been run at temperatures of 1900-2100 K and Mach numbers from 0.3 to 0.55 in argon and 0.2 in helium. The best results to date have been obtained in the helium tests. Power outputs of 2.2 kw for tests with 28 electrodes and 2.1 kw for tests with 17 electrodes were realized. Power densities of 0.6 MW/cu m and Hall fields of about 1,100 V/m were obtained in the tests with 17 electrodes.

Sovie, R. J.↗

Some services of the Time and Frequency Division of the National Bureau of Standards

The Time and Frequency Division of the National Bureau of Standards (NBS) provides several services to the general public. The radio broadcasts of WWV, WWVH, and WWVB supply reliable, unambiguous time signals to many users. The NBS telephone time-of-day service attracts several hundreds of thousands of calls each year. Periodically, the NBS provides courses on specific topics relating to time and frequency technology. In addition to numerous technical papers published each year, the NBS has prepared the first volume of a comprehensive monograph on time and frequency. The results of research in the Time and Frequency Division of the NBS have had significant impact. An active TV time system capable of serving most of the U.S. currently awaits a ruling by the FCC on a petition filed last year on behalf of the NBS by the Department of Commerce. Three more recent developments are: (1) a TV frequency comparator (patent applied for); (2) a method to perform an independent (absolute) frequency evaluation of commercial cesium beam oscillators; and (3) a method of removing one source of frequency drift in commercial cesium beam oscillators.

Barnes, J. A.↗

Development of High Quantum Efficiency UV/Blue Photocathode Epitaxial Semiconductor Heterostructures for Scintillation and Cherenkov Radiation Detection

The primary goal of this research project was to further extend the use of advanced heteroepitaxial-semiconductor crystal growth techniques such as molecular beam epitaxy (MBE) and to demonstrate significant gains in UV/blue photonic detection by designing and fabricating atomically-tailored heteroepitaxial GaAlN/GaInN photocathode device structures. This NASA Explorer technology research program has focused on the development of photocathodes for Cherenkov and scintillation radiation detection. Support from the program allowed us to enhance our MBE system to include a nitrogen plasma source and a magnetic bearing turbomolecular pump for delivery and removal of high purity atomic nitrogen during GaAlN/GaInN film growth. Under this program we have also designed, built and incorporated a cesium activation stage. In addition, a connected UHV chamber with photocathode transfer/positioner components as well as a hybrid phototube stage was designed and built to make in-situ quantum efficiency measurements without ever having to remove the photocathodes from UHV conditions. Thus we have constructed a system with the capability to couple atomically-tailored MBE-grown photocathode heterostructures with real high gain readout devices for single photon detection evaluation.

Leopold, Daniel J.↗

Low-work-function surfaces produced by cesium carbonate decomposition

Cesium carbonate (Cs2CO3) was heated to the decomposition temperature of approximately 600 C. The nonvolatile decomposition products were condensed on a nickel substrate while the carbon dioxide was removed by pumping. The deposited material is characterized by an effective work function of between 1.05 and 1.15 eV at 450 K and by photoemission in the visible and near-infrared region of the spectrum. It is suggested that the deposited material consists of Cs2O, possibly Cs2O2, and adsorbed cesium. Silver, evaporated from a heated silver bead, produced the typical photoemissive and thermionic properties of a silver-oxygen-cesium (S-1) photocathode. The material may be of interest for thermionic energy converters and for the formation of silver-oxygen-cesium photocathodes.

Briere, T. R.↗

Production of I-123

Bombarding a cesium heat pipe with high energy particles causes a spallation reaction which produces vapors of Xe-123 and contaminants. The contaminants are removed in a dry ice cold trap while the Xe-123 condenses in a liquid nitrogen trap where it decays.

Blue, J. W.↗

Thermal vacuum testing techniques for spacecraft

Cesium frequency standards are to be flown on the NTS-2 satellite which is a program conducted to develop technology and time standards for NAVSTAR Global Positioning System. Mission requirements for the thermal design of this frequency standard called for a low nominal temperature (15 C) and the removal of most of the heat generated by the standard from the spacecraft. The test program run to determine the thermal properties of the frequency standard is described. A simulator was constructed for these tests. Special mathematical analysis techniques were developed and were used to predict the thermal environment for different orbital conditions. Thermal vacuum tests of the flight frequency standard and the integrated spacecraft demonstrated the validity of this technique.

Nichols, S. A.↗

Evaluation of Observed and Modelled Aerosol Lifetimes Using Radioactive Tracers of Opportunity and an Ensemble of 19 Global Models

Aerosols have important impacts on air quality and climate, but the processes affecting their removal from the atmosphere are not fully understood and are poorly constrained by observations. This makes modelled aerosol lifetimes uncertain. In this study, we make use of an observational constraint on aerosol lifetimes provided by radionuclide measurements and investigate the causes of differences within a set of global models. During the Fukushima Dai-Ichi nuclear power plant accident of March 2011, the radioactive isotopes cesium-137 (Cs-137) and xenon-133 (Xe-133) were released in large quantities. Cesium attached to particles in the ambient air, approximately according to their available aerosol surface area. Cs-137 size distribution measurements taken close to the power plant suggested that accumulation mode (AM) sulfate aerosols were the main carriers of cesium. Hence, Cs-137 can be used as a proxy tracer for the AM sulfate aerosol's fate in the atmosphere. In contrast, the noble gas Xe-133 behaves almost like a passive transport tracer. Global surface measurements of the two radioactive isotopes taken over several months after the release allow the derivation of a lifetime of the carrier aerosol. We compare this to the lifetimes simulated by 19 different atmospheric transport models initialized with identical emissions of Cs-137that were assigned to an aerosol tracer with each model's default properties of AM sulfate, and Xe-133 emissions that were assigned to a passive tracer. We investigate to what extent the modelled sulfate tracer can reproduce the measurements, especially with respect to the observed loss of aerosol mass with time. Modelled Cs-137and Xe-133 concentrations sampled at the same location and times as station measurements allow a direct comparison between measured and modelled aerosol lifetime. The e-folding lifetime e, calculated from station measurement data taken between 2 and 9 weeks after the start of the emissions, is 14.3 days (95% confidence interval 13.1-15.7 days). The equivalent modelled e lifetimes have a large spread, varying between 4.8 and 26.7 days with a model median of 9.42.3 days, indicating too fast a removal in most models. Because sufficient measurement data were only available from about 2 weeks after the release, the estimated lifetimes apply to aerosols that have undergone long-range transport, i.e. not for freshly emitted aerosol. However, modelled instantaneous lifetimes show that the initial removal in the first 2 weeks was quicker (lifetimes between 1 and 5 days) due to the emissions occurring at low altitudes and co-location of the fresh plume with strong precipitation. Deviations between measured and modelled aerosol lifetimes are largest for the northernmost stations and at later time periods, suggesting that models do not transport enough of the aerosol towards the Arctic. The models underestimate passive tracer (Xe-133) concentrations in the Arctic as well but to a smaller extent than for the aerosol (Cs-137) tracer. This indicates that in addition to too fast an aerosol removal in the models, errors in simulated atmospheric transport towards the Arctic in most models also contribute to the underestimation of the Arctic aerosol concentrations.

Radioactive isotopes↗

A target for production of radioxenons

A liquid cesium target has been developed which permits the production and identification of the neutron deficient isotopes of xenon. The thick target yields of Xe-127 and Xe-129 m were measured for proton energies between 28 and 40 MeV. Production of Xe-129 m, as indicated by the presence of a 196 keV line in the gamma ray spectra, occurred at all proton energies; Xe-127 was produced at proton energies above 33 MeV. Both accumulated on the target with the same time constant, and the cross sections were comparable in magnitude. The radioxenons were removed from the target by a stream of carrier gas so that chemical separation was unnecessary.

Blue, J. W.↗

NaK Variable Conductance Heat Pipe for Radioisotope Stirling Systems

In a Stirling radioisotope power system, heat must continually be removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides most of this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS, but also ending use of that convertor for the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) was designed to allow multiple stops and restarts of the Stirling convertor. In the design of the VCHP for the Advanced Stirling Radioisotope Generator, the VCHP reservoir temperature can vary between 40 and 120 C. While sodium, potassium, or cesium could be used as the working fluid, their melting temperatures are above the minimum reservoir temperature, allowing working fluid to freeze in the reservoir. In contrast, the melting point of NaK is -12 C, so NaK can't freeze in the reservoir. One potential problem with NaK as a working fluid is that previous tests with NaK heat pipes have shown that NaK heat pipes can develop temperature non-uniformities in the evaporator due to NaK's binary composition. A NaK heat pipe was fabricated to measure the temperature non-uniformities in a scale model of the VCHP for the Stirling Radioisotope system. The temperature profiles in the evaporator and condenser were measured as a function of operating temperature and power. The largest delta T across the condenser was 2S C. However, the condenser delta T decreased to 16 C for the 775 C vapor temperature at the highest heat flux applied, 7.21 W/ square cm. This decrease with increasing heat flux was caused by the increased mixing of the sodium and potassium in the vapor. This temperature differential is similar to the temperature variation in this ASRG heat transfer interface without a heat pipe, so NaK can be used as the VCHP working fluid.

Tarau, Calin↗

A laser-cooled cesium fountain frequency standard and a measurement of the frequency shift due to ultra-cold collisions

A frequency standard based on an atomic fountain of cesium atoms may have an accuracy of 10(exp -16) due to longer interaction times and smaller anticipated systematic errors. All of the known systematic effects that now limit the accuracy of the Cs frequency standard increase either linearly or as some higher power of the atom's velocity. The one systematic frequency shift which is dramatically different is the frequency shift due to the collisions between the laser cooled atoms. At a temperature of a few micro-K, the de Broglie wavelength (lambda(sub deB) = h/p, where h is Planck's constant and p is the momentum of the atom) is much larger than the scale of the interatomic potential. Under these conditions the collision cross sections can be as large as (lambda(sub deB)(sup 2))/Pi and the frequency shift due to these collisions was recently calculated. In our Cs atomic fountain, we laser cooled and trapped 10(exp 10) Cs atoms in 0.4 s. By shifting the frequencies of the laser beams, the atoms were launched upwards at 2.5 m/s and a fraction of the atoms were optically pumped into the F=3 ground state. The unwanted atoms in the F=4 ground state were removed from the fountain with radiation pressure from a laser beam tuned to excite only those atoms. The Cs atoms in the F=3 state traveled ballistically upwards, were excited by the microwave cavity, and then returned back through the same cavity in the atomic fountain configuration. By varying the cold atom density, a density dependent shift of -12.9 +/- 0.7 mHz or -1.4 x 10-12 for an average fountain density of (2.7 +/- 1.5) 10(exp 9) atoms/cm(sup 3) was measured.

Gibble, Kurt↗

Materials International Space Station Experiment (MISSE): Overview, Accomplishments and Future Needs

Materials and devices used on the exterior of spacecraft in low Earth orbit (LEO) are subjected to environmental threats that can cause degradation in material properties, possibly threatening spacecraft mission success. These threats include: atomic oxygen (AO), ultraviolet and x-ray radiation, charged particle radiation, temperature extremes and thermal cycling, micrometeoroid and debris impacts, and contamination. Space environmental threats vary greatly based on spacecraft materials, thicknesses and stress levels, and the mission environment and duration. For more than a decade the Materials International Space Station Experiment (MISSE) has enabled the study of the long duration environmental durability of spacecraft materials in the LEO environment. The overall objective of MISSE is to test the stability and durability of materials and devices in the space environment in order to gain valuable knowledge on the performance of materials in space, as well as to enable lifetime predictions of new materials that may be used in future space flight. MISSE is a series of materials flight experiments, which are attached to the exterior of the International Space Station (ISS). Individual experiments were loaded onto suitcase-like trays, called Passive Experiment Containers (PECs). The PECs were transported to the ISS in the Space Shuttle cargo bay and attached to, and removed from, the ISS during extravehicular activities (EVAs). The PECs were retrieved after one or more years of space exposure and returned to Earth enabling post-flight experiment evaluation. MISSE is a multi-organization project with participants from the National Aeronautics and Space Administration (NASA), the Department of Defense (DoD), industry and academia. MISSE has provided a platform for environmental durability studies for thousands of samples and numerous devices, and it has produced many tangible impacts. Ten PECs (and one smaller tray) have been flown, representing MISSE 1 through MISSE 8, yielding long-duration space environmental performance and durability data that enable material validation, processing recertification and space qualification; improved predictions of materials and component lifetimes in space; model verification and development; and correlation factors between space-exposure and ground-facilities enabling more accurate in-space performance predictions based on ground-laboratory testing. A few of the many experiment results and observations, and their impacts, are provided. Those highlighted include examples on improved understanding of atomic oxygen scattering mechanisms, LEO coating durability results, and polymer erosion yields and their impacts on spacecraft design. The MISSE 2 Atomic Oxygen Scattering Chamber Experiment discovered that the peak flux of scattered AO was determined to be 45 deg from normal incidence, not the model predicted cosine dependence. In addition, the erosion yield (E(sub y)) of Kapton H for AO scattered off oxidized-Al is 22% of the E(sub y) of direct AO impingement. These results were used to help determine the degradation mechanism of a cesium iodide detector within the Hubble Space Telescope Cosmic Origins Spectrograph Experiment. The MISSE 6 Indium Tin Oxide (ITO) Degradation Experiment measured surface electrical resistance of ram and wake ITO coated samples. The data confirmed that ITO is a stable AO protective coating, and the results validated the durability of ITO conductive coatings for solar arrays for the Atmosphere-Space Transition 2 Explorer program. The MISSE 2, 6 and 7 Polymer Experiments have provided LEO AO Ey data on over 120 polymer and composites samples. The flight E(sub y) values were found to range from 3.05 x 10(exp -26) cu cm/atom for the AO resistant polymer CORIN to 9.14 x 10(exp -26) cu cm/atom for polyoxymethylene (POM). In addition, flying the same polymers on different missions has advanced the understanding of the AO E(sub y) dependency on solar exposure for polymers containing fluorine. The MISSE polymer results are highly requested and have impacted spacecraft design for WorldView-2 & -3, the Global Precipitation Measurement-Microwave Imager, and other spacecraft. The flight data has enabled the development of an Atomic Oxygen Erosion Predictive Tool that allows the erosion prediction of new and non-flown polymers. The data has also been used to develop a new NASA Technical Standards Handbook "Spacecraft Polymers Atomic Oxygen Durability Handbook." Many intangible benefits have also been derived from MISSE. For example, over 40 students have collaborated on Glenn's MISSE experiments, which have resulted in greater than $80K in student scholarships and awards in national and international science fairs. Students have also given presentations and won poster competition awards at international space conferences.

Flight Experiment↗