Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cell thermal design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Inverted Metamorphic AlGaInAs/GaInAs Tandem Thermophotovoltaic Cell Designed for Thermal Energy Grid Storage Application

We demonstrate an inverted metamorphic multijunction (IMM) photovoltaic cell comprising lattice-mismatched 1.2 eV AlGaInAs and 1.0 eV GaInAs junctions optimized for high-temperature thermophotovoltaic (TPV) applications. This device differs from traditional IMM solar cells because the mismatched junctions are grown at a single lattice constant. This architecture enables removal of the compositionally graded buffer that otherwise filters light from the junctions below and absorbs sub-bandgap light via free-carrier absorption. Sub-bandgap absorption dramatically reduces the efficiency of TPV systems using high reflectivity cells to enable band edge spectrum filtering. Three components required development to enable this device: (1) a lattice-mismatched 1.2 eV AlGaInAs junction, (2) a metamorphic contact layer grown after the graded buffer, and (3) a transparent tunnel junction that sits in front of the 1.0 eV GaInAs junction. Growth conditions that minimize oxygen defect incorporation maximize AlGaInAs cell quality, enabling a 0.41 V bandgap open circuit voltage offset at 22 mA/cm2 under AM1.5D. A mismatched GaInAs:Se layer is developed as a low resistance contact. Lastly, we develop a GaAsSb:C/GaInP:Se tunnel junction suitable for high-power densities with more transparency than the GaAsSb:C/GaInAs:Se structure used in past IMM cells. We characterize the tandem device under a high-intensity spectrum that approximates the emission from a 2150°C blackbody radiator and deduce a projected ideal TPV efficiency of 39.9% at ~30% of the blackbody irradiance and 36% ideal TPV efficiency under the full 118 W/cm2 irradiance. Improvements to the back-surface reflectivity and series resistance are expected to increase the ideal TPV efficiency well above 40%.

25 ENERGY STORAGE↗

Barrier Design to Prevent Metal-Induced Degradation and Improve Thermal Stability in Perovskite Solar Cells

Metal-contact-induced degradation and escape of volatile species from perovskite solar cells necessitate excellent diffusion barrier layers. We show that metal-induced degradation limits thermal stability in several perovskite chemistries with Au, Cu, and Ag gridlines even when the metal is separated from the perovskite by a layer of indium tin oxide (ITO). Channels in a sputtered ITO layer that align with perovskite grain boundaries are pathways for metal and halide diffusion into or out of the perovskite. Planarizing the perovskite morphology with a spin-cast organic charge-transport layer results in a subsequently deposited ITO layer that is uniform and impermeable. We show that it is critical to seal the edges of the active layers to prevent escape of volatile species. We demonstrate 1000 h thermal stability at 85 °C in CH 3 NH 3 PbI 3 solar cells with complete-coverage silver contacts. Lastly, our barrier layer design enables long-term thermal stability of perovskite solar cells, a critical step to commercialization.

14 SOLAR ENERGY↗

Enabling fast charging – Battery thermal considerations

Battery thermal barriers are reviewed with regards to extreme fast charging. Present-day thermal management systems for battery electric vehicles are inadequate in limiting the maximum temperature rise of the battery during extreme fast charging. If the battery thermal management system is not designed correctly, the temperature of the cells could reach abuse temperatures and potentially send the cells into thermal runaway. Furthermore, the cell and battery interconnect design needs to be improved to meet the lifetime expectations of the consumer. Each of these aspects is explored and addressed as well as outlining where the heat is generated in a cell, the efficiencies of power and energy cells, and what type of battery thermal management solutions are available in today’s market. Here, thermal management is not a limiting condition with regard to extreme fast charging, but many factors need to be addressed especially for future high specific energy density cells to meet U.S. Department of Energy cost and volume goals.

25 ENERGY STORAGE↗

Thermal Implications for Extreme Fast Charge

Present-day thermal management systems for battery electric vehicles are inadequate in limiting the maximum temperature rise of the battery during extreme fast charging. If the battery thermal management system is not designed correctly, the temperature of the cells could reach abuse temperatures and potentially send the cells into thermal runaway. Furthermore, the cell and battery interconnect design needs to be improved to meet the lifetime expectations of the consumer. Each of these aspects is explored and addressed as well as outlining where the heat is generated in a cell, the efficiencies of power and energy cells, and what type of battery thermal management solutions are available in today's market. Thermal management is not a limiting condition with regard to extreme fast charging, but many factors need to be addressed especially for future high specific energy density cells to meet U.S. Department of Energy cost and volume goals.

33 ADVANCED PROPULSION SYSTEMS↗

Identifying the Cause of Rupture of Li-Ion Batteries during Thermal Runaway

As the energy density of lithium-ion cells and batteries increases, controlling the outcomes of thermal runaway becomes more challenging. If the high rate of gas generation during thermal runaway is not adequately vented, commercial cell designs can rupture and explode, presenting serious safety concerns. Here, ultra-high-speed synchrotron X-ray imaging is used at >20 000 frames per second to characterize the venting processes of six different 18650 cell designs undergoing thermal runaway. For the first time, the mechanisms that lead to the most catastrophic type of cell failure, rupture, and explosion are identified and elucidated in detail. The practical application of the technique is highlighted by evaluating a novel 18650 cell design with a second vent at the base, which is shown to avoid the critical stages that lead to rupture. The insights yielded in this study shed new light on battery failure and are expected to guide the development of safer commercial cell designs.

25 ENERGY STORAGE↗

Battery Thermal Characterization

The operating temperature is critical in achieving the right balance between performance, cost, and life for both Li-ion batteries and ultracapacitors. The chemistries of advanced energy-storage devices - such as lithium-based batteries - are very sensitive to operating temperature. High temperatures degrade batteries faster while low temperatures decrease their power and capacity, affecting vehicle range, performance, and cost. Understanding heat generation in battery systems - from the individual cells within a module, to the inter-connects between the cells, and across the entire battery system - is imperative for designing effective thermal-management systems and battery packs. At NREL, we have developed unique capabilities to measure the thermal properties of cells and evaluate thermal performance of battery packs (air or liquid cooled). We also use our electro-thermal finite element models to analyze the thermal performance of battery systems in order to aid battery developers with improved thermal designs. NREL's tools are used to meet the weight, life, cost, and volume goals set by the U.S. Department of Energy for electric drive vehicles.

25 ENERGY STORAGE↗

Internal Short Circuits in Lithium-Ion Cells for PHEVs

Development of Plug-in Hybrid Electric Vehicles (PHEVs) has recently become a high national priority because of their potential to enable significantly reduced petroleum consumption by the domestic transportation sector in the relatively near term. Lithium-ion (Li-ion) batteries are a critical enabling technology for PHEVs. Among battery technologies with suitable operating characteristics for use in vehicles, Li-ion batteries offer the best combination of energy, power, life and cost. Consequently, worldwide, leading corporations and government agencies are supporting the development of Li-ion batteries for PHEVs, as well as the full spectrum of vehicular applications ranging from mild hybrid to all-electric. In this project, using a combination of well-defined experiments, custom designed cells and simulations, we have improved the understanding of the process by which a Li-ion cell that develops an internal short progresses to thermal runaway. Using a validated model for thermal runaway, we have explored the influence of environmental factors and cell design on the propensity for thermal runaway in full-sized PHEV cells. We have also gained important perspectives about internal short development and progression; specifically that initial internal shorts may be augmented by secondary shorts related to separator melting. Even though the nature of these shorts is very stochastic, we have shown the critical and insufficiently appreciated role of heat transfer in influencing whether a developing internal short results in a thermal runaway. This work should lead to enhanced perspectives on separator design, the role of active materials and especially cathode materials with respect to safety and the design of automotive cooling systems to enhance battery safety in PHEVs.

25 ENERGY STORAGE↗

Thermally Stable Perovskite Solar Cells by Systematic Molecular Design of the Hole-Transport Layer

With the burgeoning performance of metal halide perovskite solar cells (PSC), one of the biggest challenges to date is addressing device stability. Within the PSC device stack, charge-selective contact selection has been shown to considerably impact PSC stability. Recently, a triarylamine-based hole-transport layer (HTL) doped with its oxidized organic salt analogue (EH44/EH44-ox) has been shown to bypass the need for hygroscopic lithium salt dopants, enabling high PSC stability in ambient conditions. Despite these promising results, the improved stability came with a power conversion efficiency (PCE) penalty and poor performance above 30 degrees C. Broadening the applicability and understanding of this under-utilized dopant system, we report design criteria for stable, synthetically simple triarylamine-based organic hole transport materials (HTM) and their corresponding oxidized salts as HTL dopants for improved PSC efficiency and stability at elevated temperature. The triarylamine-based dopants must contain at least two para-electron donating groups for radical cation stabilization to prevent impurity formation (e.g., dopant reduction) which significantly reduces PSC fill factors (FF) and PCE. To further improve PSC FF and PCE, these dopants can be interchanged with respect to the HTL matrix. The stability of unencapsulated devices prepared with these three new HTLs, under constant load and illumination, considerably outperform both EH44/EH44-ox and Li+-doped spiro-OMeTAD controls at 50 degrees C. The ability to mix and match a stable dopant with a non-identical small-molecule-based HTL matrix for improved charge-transport properties broadens design scope for highly stable and cost-effective PSC without sacrificing performance.

14 SOLAR ENERGY↗

Decoupling of heat generated from ejected and non-ejected contents of 18650-format lithium-ion cells using statistical methods

Effective thermal management systems, designed to handle the impacts of thermal runaway (TR) and to prevent cell-to-cell propagation, are key to safe operation of lithium-ion (Li-ion) battery assemblies. Critical factors for optimizing these systems include the total energy released during a single cell TR event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A unique fractional thermal runaway calorimeter (FTRC), designed to characterize said critical factors, was utilized to examine the TR behavior of 18650-format Li-ion cells representing a variety of manufacturers, chemistries, capacities, and safety features. Primarily, the impacts of bottom vent (BV) safety features, varied cell casing thickness, and Dreamweaver cellulose based separators were assessed for select cell types. A subset of cells also had an imbedded internal short circuiting (ISC) device to allow examination of TR behavior initiated at lower temperatures (i.e. closer to field failure conditions). The impact of bottom rupture on TR behavior was also examined for experiments that resulted in this non-standard failure mechanism. Statistical analysis of the results for each cell configuration reveals that a lognormal distribution effectively characterizes the variation of total TR energy release. Typically 20%-30% of the total energy yield is released through the cell casing with the remainder through the ejecta material. Higher energy cells tend to exhibit more violent ejections and less predictable TR events. Inclusion of a BV feature reduces the overall severity of the TR event and can increase the predictability. Results also suggest that the magnitude of the TR event may not be directly proportional to the stored electrical energy, but rather has additional dependence on other design and failure mode factors.

25 ENERGY STORAGE↗

Heat Generation Concerns Associated with Extreme Fast Charging

Present-day thermal management systems for battery electric vehicles are inadequate in limiting the maximum temperature rise of the battery during extreme fast charging. Incorrect thermal management designs for extreme fast charging conditions could result in cells reaching abuse temperatures and potentially sending the cells into thermal runaway. Furthermore, the cell and module design needs to be improved to meet the lifetime expectations of the consumer. Each of these aspects is explored and addressed as well as outlining where the heat is generated in a cell, the efficiencies of power and energy cells, and how to potentially measure the internal temperatures of a battery. Thermal management is not a limiting condition with regards to extreme fast charging, but many factors need to be addressed especially for future high specific energy density cells to meet U.S. Department of Energy cost and volume goals.

ADVANCED PROPULSION SYSTEMS↗

Simulation of thermal hydraulic performance of multiple parallel micropin arrays for concentrating solar thermal applications with supercritical carbon dioxide

Concentrated solar power (CSP) plants have the potential to provide 24 h, renewable electricity. Current CSP systems have high capital and operational costs which makes the levelized cost of electricity uncompetitive with conventional techniques. Recent experimental research has shown the potential of small unit cells (up to 2 × 2 cm) containing micropin arrays (D H < 1 mm) to operate efficiently at high incident flux (>140 W cm -2 ) using supercritical carbon dioxide as the working fluid. Applying this technology to CSP systems would result in a smaller central receiver, which would reduce thermal losses, increase receiver efficiency and reduce the capital cost of the receiver component. This study investigates and addresses the practical thermal and hydraulic issues in numbering up these small unit cells into numerous parallel cells within an integrated module design. A thermal hydraulic network model is developed to quantify the distribution and the overall receiver efficiency of an integrated module. This model is used to specify maximum allowable unit cell size and header dimensions to maintain acceptable thermal performance and pressure loss. Once a module design was finalized, parametric studies were performed to study the effects of varying incident flux on flow distribution and thermal performance of the module. Finally, the results show that an integrated module design can be achieved with less than 5% flow maldistribution and a pressure drop acceptable to the remainder of the system.

14 SOLAR ENERGY↗

Abstract - Cooperative Research and Development Agreement between AK Supply, Inc. and National Energy Technology Laboratory

The main goal of CRADA between AK Supply and NETL is to redesign the solid oxide fuel cell configuration for hybrid power generation systems for greater flexibility and operability. The new fuel cell design will consider incorporation of thermal energy storage into the fuel cell by modifying the material composition to increase the specific heat and/or the solid-solid phase transition and increasing the interconnect geometry (mass and volume) in the fuel cell. This developed technology will be tested using Hyper facility at NETL, Morgantown, to evaluate the performance in hybrid applications. Additionally, AK Supply and NETL will work on the development of a real-time, high temperature, intelligent micro-sensor for monitoring energy availability in the interconnect geometry. The will be used for control of stored energy release during load transients and will be tested on the NETL Hyper facility.

25 ENERGY STORAGE↗

Transformational Solid Oxide Fuel Cell (SOFC) Technology

This project was conducted under the Co-operative Agreement No. DE-FE0027584 with the US Department Energy to developed advanced Solid Oxide Fuel Cell (SOFC) Technologies. The overall objective of this project was to advance SOFC technology at the cell and stack level to enhance cell robustness and durability, increase performance, and reduce balance-of-plant (BOP) requirements. By reducing system complexity combined with the increases in power density and efficiency, the ultimate goal of the project was to increased reliability and to reduce capital and operating costs of installed systems. The project was focused on pathways that will reduce the cost of the SOFC cell and stack, including the following areas: Robust, redox tolerant cell technology Lower cost cell manufacturing through advances in cell design, which will reduce the amount of material, energy and time used in the fabrication of SOFCs High performance, low temperature electrolyte based on improvement of established materials Innovative SOFC stack architecture which truly integrates Balance of Plant functionality into the stack level design Thermal management of the fuel cell stack for increased durability and expanded window of operation Novel stack design amenable for use in sub-MW to multi-MW-scale power plants and having low replacement cost The incorporation of balance-of-plant (BOP) equipment into the stack platform increased the economic viability of smaller scale systems. The project objectives were met by a multi-prong approach, including new cell design complemented with modifications to existing cell technology, as well as a new stack design incorporating components typically included in the BOP, such as heat exchangers, oxidizer, fuel reformers, and recycle systems. The project culminated with demonstration of a stack test validating the viability of the cell and stack improvements. A cost model was also developed to estimate costs for the advanced stack technology at high volume manufacturing levels. The net outcome of the project is SOFC cell and stack technology with costs significantly below current DOE targets without compromising and, in some cases, improving on the performance and degradation rate demonstrated with the current state-of-the-art stack design. The results of this project advanced the reliability, robustness, and endurance of low-cost SOFC technology that ultimately are ready to be deployed in coal power systems with greater than 60 percent efficiency (based on higher heating value of fuel) and the capability for ≥97% CO 2 capture at a cost-of-electricity that is approximately 40 percent below presently available Integrated Gasification Combined Cycle systems.

03 NATURAL GAS↗

Thermally Conductive Backsheets (TCB) for Reduced Operating Temperatures

The performance of photovoltaic (PV) modules is primarily influenced by the plane of array (POA) irradiance and their operating temperature. The lower the module operating temperature, the higher is its performance. Increasing a module’s operating temperature reduces its power output due to an increase in the semiconductor’s intrinsic carrier density, leading to a reduction in the open-circuit voltage and, subsequently, reducing the maximum power point voltage. Reducing the operating temperature lowers the levelized cost of energy (LCOE) via increased energy production (i.e., more kilowatt hour over the life of the asset) and increased service lifetime (years in the field). The module operating temperature is dictated by the weather parameters and the thermal properties of module construction materials. The primary weather parameters influencing the PV module temperature are: the ambient temperature (directly related), irradiance (directly related), and wind speed (inversely related). The primary thermal properties of module construction materials influencing the PV module temperature are: the optical transmissivity and thermal conductivity of superstrate, the thermal conductivity of substrate, the thermal conductivity of encapsulant and the efficiency of the encapsulated solar cells. The primary goal of this study is to reduce the operating temperature of PV modules using thermally conductive backsheet (TCB) substrates developed by the industry. The temperature of PV modules installed in a large multi-MW plant can also be influenced by their physical locations in the plants due to the influence of wind direction. A thermal mapping of PV plants has also been investigated and presented in this study. The most commonly used PV backsheet material has been polyvinyl fluoride (DuPont trade name “Tedlar”)-based backsheet, which typically has three layers: Tedlar–polyethylene terephthalate (PET)–Tedlar (TPT). The primary goal of this project is to reduce the module operating temperature below the benchmark TPT backsheet temperature using newly developed TCBs by the industry. The overall approach of this project involves six focus areas: i) select and procure one TPT and thirteen promising TCBs available in the industry; ii) construct a large number of 1-cell and 9-cell modules using benchmark TPT and selected TCBs [all other construction materials are fixed and they are: glass superstrate, EVA encapsulant, mono-Si cell and junction box]; iii) to identify best performing TCBs, monitor the long-term field operating temperatures of the constructed modules which are installed in three climatic conditions (hot-low wind [Mesa, AZ], hot-high wind [Maricopa County, AZ] and temperate [Cumberland County, NC]; iv) to identify the most durable TCB, perform extended accelerated reliability testing of modules constructed with best three TCBs and benchmark TPT; v) to predict module temperature, develop physical and empirical thermal models with and without thermal properties of all construction materials in the modules, respectively; and vi) to determine the influence of wind speed and direction on the module operating temperature in a plant, and perform thermal mapping of PV modules in two large PV plants [Maricopa County, AZ and Cumberland County, NC]. The key achievements of this project are listed below: Backsheet selection: 14 backsheets were procured after an extensive literature and industry search. Finally, based on the thermal and other selection criteria, 1 TPT and 4 thermally conductive backsheets were selected for this project. Fabrication of mini modules: 50 one-cell modules were fabricated in year 1 for thermal performance evaluation. The module design was changed to nine-cell module at start of year 2 to mimic commercial design. 20 nine-cell modules were fabricated in year 2 for thermal performance evaluation. 28 four-cell modules were fabricated in year 3 for accelerated stress-testing. Thermal conductivity of backsheets: Year 1 TCBs showed at least 8% higher thermal conductivities than TPT. Year 2 and 3 TCBs showed at least 20% higher thermal conductivities than TPT. Installation of mini PV modules at three sites: 6 one-cell modules and 8 nine-cell modules were installed at AZ-1 site [Mesa, AZ]. 12 one-cell modules and 6 nine-cell modules were installed at each of two powerplants (AZ-2 [Maricopa County, AZ] and NC sites). Nominal operating cell temperatures (NOCT) of mini PV modules: NOCT of TCBs were observed to be lower than TPT with differences as high as 2°C. Comparison of thermal performance: The median operating temperature of one-cell modules was found to be reduced by 2°C by using TCB_A modules compared to TPT modules on several days in a month for few months in a year. The median temperature improvement of 4oC was achieved at several instances on a few days, but not all days, in a year using multiple TCBs compared to TPT. The final project milestone of achieving median temperature improvement of 5oC was achieved at several instances on a few days, but not all days, in a year using TCB_A compared to TPT. Empirical thermal model (without the need of construction material properties): Empirical thermal model for one-cell module was developed based on the input data of irradiance, wind speed and ambient temperatures. The primary input data differentiator for temperature differences between TPT and TCBs appears to be the irradiance level (solar gain). Accelerated durability testing: 20 four-cell modules using 4 backsheets (1 TPT and 3 TCBs) were exposed to Damp Heat 1000 hours (8 modules), UV/Thermal cycling (50 cycles)/Humidity freeze (10 cycles) test sequence (8 modules) and UV Weathering for qualification (8 modules). All the modules with four selected backsheets passed the stress tests per the retest guidelines of IEC 61215 standard for the backsheet change. Simplified comparative LCOE analysis: Using backsheet-specific power degradation levels in the accelerated tests (for TCB_A and TPT only), efficiency, service lifetime and assuming same cost for all backsheets, the LCOE of modules using TCB_A is determined to be lower than TPT. Due to lower operating temperature of TCB_A-based modules compared to TPT-based modules, the operating efficiency and service life of TCB_A-based modules are calculated to be higher than TPT-based modules. Temperature mapping of PV power plants: A distinct temperature difference (as high as 4°C) has been observed between the modules located in various parts of a single PV plant.

14 SOLAR ENERGY↗