Engineering PapersSearch

SEARCH · Engineering Papers

Results for “ccn”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Simultaneous operation of three CCN counters and an isothermal haze chamber at the 1980 International CCN Workshop

Four devices were operated for the detection and characterization of cloud condensation nuclei (CCN) and fog condensation nuclei (FCN). In chronological order of development, the CCN devices are the conventional continuous-flow diffusion chamber (CFD), the rapid-cycle CCN spectrometer, and the instantaneous CCN spectrometer. The FCN detection device is an isothermal haze chamber (IHC). These four instruments are discussed and general comments on their performance at the workshop are given.

Hudson, J. G.

Investigation of the CCN Activity, BC and UVBC Mass Concentrations of Biomass Burning Aerosols during the 2013 BASELInE Campaign

Biomass-burning (BB) aerosols, acting as cloud condensation nuclei (CCN), can influence cloud microphysical and radiative properties. In this study, we present CCN measured near the BB source regions over northern Southeast Asia (Doi Ang Khang, Thailand) and at downwind receptor areas (Lulin Atmospheric Background Station, Taiwan), focusing exclusively on 13-20 March 2013 as part of 2013 spring campaign of the Seven SouthEast Asian Studies (7-SEAS) intensive observation. One of the campaigns objectives is to characterize BB aerosols serving as CCN in SouthEast Asia (SEA). CCN concentrations were measured by a CCN counter at 5 supersaturation (SS) levels: 0.15%, 0.30%, 0.45%, 0.60%, and 0.75%. In addition, PM2.5 and black carbon mass concentrations were analyzed by using a tapered element oscillating microbalance and an aethalometer. It was found the number-size distributions and the characteristics of hygroscopicity (e.g., activation ratio and k) of BB aerosols in SEA have a strong diurnal pattern, and different behaviors of patterns were characterized under two distinct weather systems. The overall average value was low (0.05-0.1) but comparable with previous CCN studies in other BB source regions. Furthermore, a large fraction of UV-absorbing organic material (UVBC) and high Delta-C among BB aerosols were also observed, which suggest the existence of substantial particulate organic matter in fresh BB aerosols. These data provide the most extensive characterization of BB aerosols in SEA until now.

biomass burning aerosol

Contribution to CCN Workshop report from University of Wyoming group

The group's CCN counter is described. It is a static, horizontal, parallel plate thermal gradient diffusion chamber. Examples of the application of the CCN are presented and include the CCN spectra measured during the winter of 1978-79 near Elk Mountain, Wyoming. Comparisons of droplet concentrations derived from upwind CCN spectra are covered.

Rogers, D. C.

Influence of anthropogenic CCN on stratus microphysics

Analysis of the airborne measurements of CCN from the FIRE marine stratocumulus project of 1987 shows that continental aerosol was pervasive in air immediately above widespread stratus decks more than 500 km from the coast of California. Indications are that a large portion of the CCN component of the continental aerosol is anthropogenic. An important issue concerning continental CCN production is the question of the ratio of manmade CCN to natural particle production processes. The measurements certainly indicate that southern California air pollution or at the least continental aerosol is manifested in the cloud and above cloud aerosol.

Hudson, James G.

Three millimeter molecular line observations in Sagittarius B2. 1: Full synthesis mapping study of HNO, CCS, and HC(13)CCN

We present the first full synthesis maps of the small molecules HNO, CCS, and HC(13)CCN in Sgr B2. We have observed the 3.8 mm continuum, the HNO J(sub K(sub -1)K(sub 1)) = 1(sub O1)-0(sub OO), the CCS J(sub N) = 7(sub 6)-6(sub 5), and the HC(13)CCN J = 9-8 transitions in the core of the Sgr B2 molecular cloud, using the Berkeley Illinois Maryland Association (BIMA) millimeter array and the NRAO 12 m telescope. We have found that HNO exists in five major gas clumps in the Sgr B2 region, which we have labeled HNO(N), HNO(NW), HNO(E), HNO(M), and HNO(S). Of particular interest is HNO(M), a major molecular gas concentration approximately 15 sec west of Sgr B2(M) in a region of young star formation. HNO is found to be closely associated with the ionized gas and might be depleted around bright H II complexes. In general, the peak intensity of the HNO emission is found to be offset from the peak of the continuum emission. We found evidence for some chemical differentiation among the three species, HNO, CCS, and HC(13)CCN, but the abundance ratios are in fair agreement with theoretical models. Two unidentified lines, U81420 and U81518, were observed, and a previously unknown compact dust source was detected. Our HNO data indicate the presence of a rotating approximately (2.2-4.4) x 10(exp 3)solar mass gas envelope surrounding Sgr B2(N), a possible bipolar gas outflow in HNO(M), and possibly a large (approximately 4.2 x 10(exp 4)solar mass) extended rotating disk associated with HNO(S). In addition, the CCS and HC(13)CCN data approximately outline the extended component of Sgr B2 and clearly show that the southern continuum source Sgr B2(S) is actually a major molecular source as well. Consequently, the kinematics of the Sgr B2 molecular cloud is quite complex, but in moving from the northwest to south, the LSR velocity generally changes from 79 to 46 km/s.

Kuan, Yi-Jehng

Toward Aerosol/Cloud Condensation Nuclei (CCN) Closure during CRYSTAL-FACE

During July 2002, measurements of cloud condensation nuclei were made in the vicinity of southwest Florida as part of the Cirrus Regional Study of Tropical Anvils and Cirrus Layers-Florida Area Cirrus Experiment (CRYSTAL-FACE) field campaign. These observations, at supersaturations of 0.2 and 0.85%, are presented here. The performance of each of the two CCN counters was validated through laboratory calibration and an in situ intercomparison. The measurements indicate that the aerosol sampled during the campaign was predominantly marine in character: the median concentrations were 233 cm-3 (at S = 0.2%) and 371 cm(sup -3) (at S = 0.85%). Three flights during the experiment differed from this general trend; the aerosol sampled during the two flights on 18 July was more continental in character, and the observations on 28 July indicate high spatial variability and periods of very high aerosol concentrations. This study also includes a simplified aerosol/CCN closure analysis. Aerosol size distributions were measured simultaneously with the CCN observations, and these data are used to predict a CCN concentration using Kohler theory. For the purpose of this analysis, an idealized composition of pure ammonium sulfate was assumed. The analysis indicates that in this case, there was good general agreement between the predicted and observed CCN concentrations: at S = 0.2%, N(sub predicted)/N(sub observed)= 1.047 (R(sup 2)= 0.911)); at S = 0.85%, N(sub predicted)/N(sub observed)=1.201 (R(sup 2)= 0.835)). The impacts of the compositional assumption and of including in-cloud data in the analysis are addressed. The effect of removing the data from the 28 July flight is also examined; doing so improves the result of the closure analysis at S = 0.85%. When omitting that atypical flight, N(sub predicted)/N(sub observed) = 1.085 (R(sup 2) = 0.770) at S = 0.85%.

VanReken, Timothy M.

Stratospheric CCN sampling program

When Mt. St. Helens produced several major eruptions in the late spring of 1980, there was a strong interest in the characterization of the cloud condensation nuclei (CCN) activity of the material that was injected into the troposphere and stratosphere. The scientific value of CCN measurements is two fold: CCN counts may be directly applied to calculations of the interaction of the aerosol (enlargement) at atmospherically-realistic relative humidities or supersaturations; and if the chemical constituency of the aerosol can be assumed, the number-versus-critical supersaturation spectrum may be converted into a dry aerosol size spectrum covering a size region not readily measured by other methods. The sampling method is described along with the instrumentation used in the experiments.

Rogers, C. F.

CCN-supersaturation spectra slopes (k)

Theoretically the slope k of a CCN-supesaturation spectrum should equal two thirds of the slope of the total (soluble) aerosol size distribution. Workshop results tended to verify this relation. The k values are markedly different depending on whether one is measuring ambient CCN concentrations at supersaturations S above or below approximately 0.1-0.2%. The larger k values for S approximately 0.1% is consistent with the greater decrease in large particle concentration with increasing size. It is concluded that over the S range of 0.02% to 2%, two power fits (and k values) may sometimes suffice for a reasonable approximation of the CCN distribution. At other times, and with laboratory generated aeosols, such an approach is inadequate and requires refinement.

Jiusto, J. E.

Comparison between two Aitken counters and with cloud condensation nuclei counters at the 1980 International CCN Workshop

The Pollak and the TSI 3020 counters agreed to within about 10% at concentrations below 1000 cu cm, whereas above that concentration, substantial systematic differences were observed. When the test aerosol was monodisperse and the CCN counters were operated at supersaturations that should nucleate all the aerosol, the Pollak counter read about 6% to 20% lower than the CCN counter in the concentration range from 250/cu cm to 1800/cu cm. The TSI 3020 read about 20% lower than the CCN counter at concentrations less than 1000/cu cm, and a factor of about two higher at concentrations above 1000/cu cm.

Rogers, C. F.

Model test of CCN-cloud albedo climate forcing

Cloud condensation nuclei (CCN) influence cloud albedo through their effect on the cloud droplet size distribution. A number of studies have evaluated the climatic impact of the CCN-cloud albedo feedback, but all have assumed that cloud distributions, cloud thicknesses, and cloud liquid water contents would remain constant as the climate adjusted. This assumption has been tested using the Livermore version of the National Center for Atmospheric Research Community Climate Model. The results indicate that there are no significant compensating changes in cloud properties that would counteract the 1.7 percent global albedo increase resulting from a fourfold increase in marine CCN concentration. Furthermore, when ocean surface temperatures are decreased 4 C in a manner broadly consistent with the enhanced cloud albedos, an increase in cloud fraction of 3.5 percent and a reduction in cloud altitude are predicted, leading to a positive feedback from clouds that would imply a climate impact roughly double that calculated from cloud droplet size distribution change alone.

Ghan, S. J.

Stratospheric CCN sampling program

Two one liter grab samples of stratospheric aerosol were returned from each of six U-2 sampling missions. Cloud condensation nuclei (CCN) spectra from each sample were obtained. Interest was centered on the effects of volcanic activity. Spurious particle generation was found to be a serious problem in container 9 LFT and a much smaller problem in container 9 RT. Initial studies of an option for improved sample containers and values were completed. A CCN spectrometer, able to operate at an internal pressure of 300 mb, was designed.

Rogers, C. F.

The CCN counter of the IOPG of Puy de Dome: Main characterisics and results of measurements

In performing the data analysis of the measurements achieved during the Workshop with the device, a global approach was preferred rather than an individual analysis, in order to illustrate some main characteristics in the behavior of the device with respect to a mean behavior resulting from a general survey of all the equipments involved in each experiment. The device tends generally to overestimate the CCN concentrations measured near the high supersaturations and sometimes underestimates the concentrations close to 0.1% or 0.2% of supersaturation. Despite the fact that it belongs to a type of static diffusion chamber, it shows, however, similar spectra to those obtained with other types of chambers (continuous flow diffusion chamber and haze chamber).

Serpolay, R.

A description of the UK Meteorological Office CCN counter

The chamber is a thermal gradient diffusion type with the upper plate at room temperature and the lower plate thermoelectrically cooled. The light from a 25W projector bulb is focused in a beam of approximations 1x3 mm in the central part of the chamber. The light scattered by drops is viewed in the forward direction (40 deg) by a microscope and a sensitive photodetector. Experiments were performed to relate the peak output from the photocell with the maximum number of drops in the beam recorded photographically. The microscope is used to check the calibration at low concentrations of CCN. The results of the experiments and the performance of the counter are reported.

Kitchen, M.

CCN comparisons of static diffusion chambers

Nine CCN counters of the static diffusion (SDC) type were compared with one another and with continuous flow diffusion (CFD) chambers. The nine SDCs showed a considerable amount of variation, largely attributable to newness and/or lack of prior calibration of some units. The five more consistent instruments agreed quite well, to within at least 20 percent of the NRL mobility analyzer and to within 10 percent at 1 percent supersaturation. There was satisfactory agreement between the more reliable SDC and CFD chambers.

Jiusto, J. E.

UMR dual mode CCN counter (modes: CFD plus haze)

The chamber consists of two vertical plates 100 cm long in the vertical direction and 13 cm wide, with a 0.8 cm spacing between the plates. The haze mode is used for the nuclei active at supersaturations (S) from 0.0133 to 0.173%. In this mode the two plates are kept at the same temperature (25 C). In the CFD mode the supersaturation is determined by the temperature difference between the two plates. About 40 minutes is required to obtain a spectrum (5 values of S in the CFD mode, plus 7 values of S in the haze mode). About half of this time is used to adjust the temperatures and flows; the rest is used in actual counting of the nuclei. Comparisons of the counter to other types of counters are reported.

Alofs, D. J.

An automatic light scattering CCN counter

The counter is a static thermal diffusion chamber which has been modified to include an optical system for the determination of droplet concentration by the measurement of scattered light. The determination of concentration is made by measurement of the peak scattered light signal from the cloud of growing droplets which is a function of both the droplet concentration and chamber supersaturation. Because the formation of the peak is related to the rate of growth of the droplets and sedimentation, both of which are determined by supersaturation, the system calibration can be uniquely determined by comparison with an absolute counter such as a static diffusion chamber with a photographic recording system.

Lala, G. G.