Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

X-ray cavities in a sample of 83 SPT-selected clusters of galaxies: Tracing the evolution of AGN feedback in clusters of galaxies out to z = 1.2

X-ray cavities are key tracers of mechanical (or radio mode) heating arising from the active galactic nuclei (AGNs) in brightest cluster galaxies (BCGs). We report on a survey for X-ray cavities in 83 massive, high-redshift (0.4 7 Gyr at z∼0.8). On average, the detected X-ray cavities have powers of (0.8−5)×10{sup 45} erg s{sup −1}, enthalpies of (3−6)×10{sup 59} erg, and radii of ∼17 kpc. Integrating over 7 Gyr, we find that the supermassive black holes in BCGs may have accreted 10{sup 8} to several 10{sup 9} M{sub ⊙} of material to power these outflows. This level of accretion indicates that significant supermassive black hole growth may occur not only at early times, in the quasar era, but at late times as well. We also find that X-ray cavities at high redshift may inject an excess heat of 0.1–1.0 keV per particle into the hot ICM above and beyond the energy needed to offset cooling. Although this result needs to be confirmed, we note that the magnitude of excess heating is similar to the energy needed to preheat clusters, break self-similarity, and explain the excess entropy in hot atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced photodetection in graphene-integrated photonic crystal cavity

We demonstrate the controlled enhancement of photoresponsivity in a graphene photodetector by coupling to slow light modes in a long photonic crystal linear defect cavity. Near the Brillouin zone (BZ) boundary, spectral coupling of multiple cavity modes results in broad-band photocurrent enhancement from 1530 nm to 1540 nm. Away from the BZ boundary, individual cavity resonances enhance the photocurrent eight-fold in narrow resonant peaks. Optimization of the photocurrent via critical coupling of the incident field with the graphene-cavity system is discussed. The enhanced photocurrent demonstrates the feasibility of a wavelength-scale graphene photodetector for efficient photodetection with high spectral selectivity and broadband response.

36 MATERIALS SCIENCE↗

Nb3Sn Coating of Twin Axis Cavity for SRF Applications

The twin axis cavity with two identical accelerating beams has been proposed for Energy recovery linac (ERL) applications. Nb3Sn is a superconducting material with a higher critical temperature and a higher critical field as compared to Nb, which promises a lower operating cost due to higher quality factors. Two niobium twin axis cavities fabricated at JLab and were proposed to be coated with Nb3Sn. Due to their more complex geometry, the typical coating process used for basic elliptical cavities needs to be improved to coat these cavities. This devel-opment advances the current coating system at JLab for coating complex cavities. Two twin axis cavities were coated recently for the first time. This contribution dis-cusses initial results from coating of twin axis cavities, RF testing and witness sample analysis with an overview of the current challenges towards high performance Nb3Sn coated twin axis cavities.

Tiskumara, J.↗

Co-sputter deposition of Nb₃Sn layer into SRF cavity using Nb-Sn composite target

Nb₃Sn, with its superior superconducting critical temperature (Tc ~18.3 K) and superheating field (Hsh ~400 mT), is considered a promising material for superconducting radiofrequency (SRF) cavities, offering enhanced cryogenic performance compared to bulk niobium cavities. A Nb₃Sn coating technique has been developed for Nb SRF cavities using co-sputtering of Nb-Sn composite target in a DC cylindrical magnetron sputtering system. The composite target configuration and discharge conditions for co-sputtering were optimized to deposit Nb-Sn films on flat Nb substrates, followed by annealing to form Nb₃Sn. Multiple strategies have been explored to improve the surface homogeneity of the Nb₃Sn coating, including optimizing a two-step annealing process, annealing in Sn vapor, and a light Sn recoating process. A 1.5 µm Nb-Sn co-sputtered film was deposited on the interior of a 2.6 GHz Nb SRF cavity and annealed at 600 °C for 6 h, followed by 950 °C for 1 h. Cryogenic RF testing of the annealed cavity demonstrated a Tc of 17.8 K, confirming the formation of Nb₃Sn. Then, the annealed cavity underwent a light recoating treatment and attained a quality factor (Q0) of 8.5E+08 at 2.0 K.

Accelerator Physics↗

Preliminary Cryogenic Cold Test Results of the First 9-Cell LSF Shape Cavity

Following successful prototyping and testing of single- & 5-cell LSF shape cavities *, **, the first 9-cell LSF shape cavity LSF9-1 was successfully constructed using an innovative process at JLab with the in-house facilities. The cavity was then shipped to KEK for post-fabrication mechanical adjustment and ILC TDR style treatment and surface processing. Cold testing was carried out at the JLab VTA facility, instrumented with a suite of Kyoto instruments. Favorable values for the bath pressure detuning sensitivity and Lorentz force detuning coefficient were experimentally measured, validating the design improvement in cell stiffeners. Pass-band measurements indicate 4 out of 9 cells reaching gradient capability of > 45 MV/m, including 2 cells reaching 51 MV/m. Cornell OST detectors identified the cell and location responsible for the current hard quench limit. Multipacting-like barriers observed in end cells are investigated both analytically and numerically. The cavity was shipped to FNAL and received a light EP at the joint ANL/FNAL facility for further cold testing at Jlab. Two new 9-cell LSF cavities are being constructed including one made of large-grain niobium material.

43 PARTICLE ACCELERATORS↗

Resonant-frequency discharge in a multi-cell radio frequency cavity

We are reporting experimental results on a microwave discharge operating at resonant frequency in a multi-cell radio frequency (RF) accelerator cavity. Although the discharge operated at room temperature, the setup was constructed so that it could be used for plasma generation and processing in fully assembled active superconducting radio-frequency cryo-module. This discharge offers a mechanism for removal of a variety of contaminants, organic or oxide layers, and residual particulates from the interior surface of RF cavities through the interaction of plasma-generated radicals with the cavity walls. We describe resonant RF breakdown conditions and address the issues related to resonant detuning due to sustained multi-cell cavity plasma. We have determined breakdown conditions in the cavity, which was acting as a plasma vessel with distorted cylindrical geometry. We discuss the spectroscopic data taken during plasma removal of contaminants and use them to evaluate plasma parameters, characterize the process, and estimate the volatile contaminant product removal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanostructural features degrading the performance of superconducting radio frequency niobium cavities revealed by transmission electron microscopy and electron energy loss spectroscopy

Nanoscale defect structure within the magnetic penetration depth of ∼100 nm is key to the performance limitations of niobium superconducting radio frequency cavities. Using a unique combination of advanced thermometry during cavity RF measurements, and TEM structural and compositional characterization of the samples extracted from cavity walls, we discover the existence of nanoscale hydrides in electropolished cavities limited by the high field Q slope, and show the decreased hydride formation in the electropolished cavity after 120 °C baking. Furthermore, we demonstrate that adding 800 °C hydrogen degassing followed by light buffered chemical polishing restores the hydride formation to the pre-120 °C bake level. We also show absence of niobium oxides along the grain boundaries and the modifications of the surface oxide upon 120 °C bake.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Defect- and Strain-enhanced Cavity Formation and Au Precipitation at nano-crystalline ZrO2/SiO2/Si Interfaces

Defect- and strain-enhanced cavity formation and Au precipitation at the interfaces of a nanocrystalline ZrO2/SiO2/Si multilayer structure resulting from 2 MeV Au+ irradiation at temperatures of 160 and 400 K have been studied. Under irradiation, loss of oxygen is observed, and the nanocrystalline grains in the ZrO2 layer increase in size. In addition, small cavities are observed at the ZrO2/SiO2 interface with the morphology of the cavities being dependent on the damage state of the underlying Si lattice. Elongated cavities are formed when crystallinity is still retained in the heavily-damaged Si substrate; however, the morphology of the cavities becomes spherical when the substrate is amorphized. With further irradiation, the cavities appear to become stabilized and begin to act as gettering sites for the Au. As the cavities become fully saturated with Au, the ZrO2/SiO2 interface then acts as a gettering site for the Au. Analysis of the results suggests that oxygen diffusion along the grain boundaries contributes to the growth of cavities and that oxygen within the cavities may affect the gettering of Au. Mechanisms of defect- and strain-enhanced cavity formation and Au precipitation at the interfaces will be discussed with focus on oxygen diffusion and vacancy accumulation, the role of the lattice strain on the morphology of the cavities, and the effect of the binding free energy of the cavities on the Au precipitation.

36 MATERIALS SCIENCE↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

Commissioning of a two-target DC cylindrical magnetron sputter coater for depositing Nb 3 Sn film on Nb superconducting radiofrequency cavities

A DC cylindrical magnetron sputter coater was commissioned and used to coat Nb 2.6 GHz superconducting radiofrequency (SRF) cavity with Nb 3 Sn. The sputter coater has two identical cylindrical magnetrons that can move, with a controlled speed, along the axis of the SRF cavity to coat the inside surface of the cavity. The design of the sputter coater is discussed, along with its performance. Initially, a sample holder that allows coating on flat substrates at positions similar to the equator and beam tubes of a 2.6 GHz SRF cavity was used to test conditions for fabricating Nb 3 Sn layers. Multilayers of Nb and Sn were sequentially sputtered on flat Nb and sapphire substrates mounted on the equivalent positions of the cavity's beam tubes and the equator using the two identical cylindrical magnetrons. Then, the Nb/Sn multilayers were annealed at 950 °C for 3 h. Here, the ~1.2 μm thick Nb 3 Sn film did not show any other Nb–Sn compounds and had a superconducting transition temperature of 17.61–17.76 K. The 2.6 GHz SRF cavity was coated using similar conditions as flat samples. Cryogenic RF testing of the Nb 3 Sn-coated cavity demonstrated a quality factor of 3.2 × 10 8 at an accelerating gradient of 5 MV/m at 4.4 K.

43 PARTICLE ACCELERATORS↗

A Fano cavity test for Monte Carlo proton transport algorithms

Purpose: In the scope of reference dosimetry of radiotherapy beams, Monte Carlo (MC) simulations are widely used to compute ionization chamber dose response accurately. Uncertainties related to the transport algorithm can be verified performing self-consistency tests, i.e., the so-called “Fano cavity test.” The Fano cavity test is based on the Fano theorem, which states that under charged particle equilibrium conditions, the charged particle fluence is independent of the mass density of the media as long as the cross-sections are uniform. Such tests have not been performed yet for MC codes simulating proton transport. The objectives of this study are to design a new Fano cavity test for proton MC and to implement the methodology in two MC codes: Geant4 and PENELOPE extended to protons (PENH). Methods: The new Fano test is designed to evaluate the accuracy of proton transport. Virtual particles with an energy ofE{sub 0} and a mass macroscopic cross section of (Σ)/(ρ) are transported, having the ability to generate protons with kinetic energy E{sub 0} and to be restored after each interaction, thus providing proton equilibrium. To perform the test, the authors use a simplified simulation model and rigorously demonstrate that the computed cavity dose per incident fluence must equal (ΣE{sub 0})/(ρ) , as expected in classic Fano tests. The implementation of the test is performed in Geant4 and PENH. The geometry used for testing is a 10 × 10 cm{sup 2} parallel virtual field and a cavity (2 × 2 × 0.2 cm{sup 3} size) in a water phantom with dimensions large enough to ensure proton equilibrium. Results: For conservative user-defined simulation parameters (leading to small step sizes), both Geant4 and PENH pass the Fano cavity test within 0.1%. However, differences of 0.6% and 0.7% were observed for PENH and Geant4, respectively, using larger step sizes. For PENH, the difference is attributed to the random-hinge method that introduces an artificial energy straggling if step size is not small enough. Conclusions: Using conservative user-defined simulation parameters, both PENH and Geant4 pass the Fano cavity test for proton transport. Our methodology is applicable to any kind of charged particle, provided that the considered MC code is able to track the charged particle considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and performance of a new induction furnace for heat treatment of superconducting radiofrequency niobium cavities

Superconducting radio frequency (SRF) cavities made of high purity niobium (Nb) are the building blocks of many modern particle accelerators. The fabrication process includes several cycles of chemical and heat treatment at low ({approx}120 Degree-Sign C) and high ({approx}800 Degree-Sign C) temperatures. In this contribution, we describe the design and performance of an ultra-high-vacuum furnace which uses an induction heating system to heat treat SRF cavities. Cavities are heated by radiation from the Nb susceptor. By using an all-niobium hot zone, contamination of the Nb cavity by foreign elements during heat treatment is minimized and allows avoiding subsequent chemical etching. The furnace was operated up to 1400 Degree-Sign C with a maximum pressure of {approx}1 Multiplication-Sign 10{sup -5} Torr and the maximum achievable temperature is estimated to be higher than 2000 Degree-Sign C. Initial results on the performance of a single cell 1.5 GHz cavity made of ingot Nb heat treated at 1200 Degree-Sign C using this new induction furnace and without subsequent chemical etching showed a reduction of the RF losses by a factor of {approx}2 compared to cavities made of fine-grain Nb which underwent standard chemical and heat treatments.

43 PARTICLE ACCELERATORS↗

Controlling the transport of single photons by tuning the frequency of either one or two cavities in an array of coupled cavities

We theoretically study how to control transport, bound states, and resonant states of a single photon in a one-dimensional coupled-cavity array. We find that the transport of a single photon in the cavity array can be controlled by tuning the frequency of either one or two cavities. If one of the cavities in the array has a tunable frequency, and its frequency is tuned to be larger (or smaller) than those of other cavities, then there is a photon bound state above (or below) the energy band of the coupled-cavity array. However, if two cavities in the array have tunable frequencies, then there exist both bound states and resonant states. If the frequencies of the two cavities are chosen to be much larger than those of other cavities, and the hopping couplings between any two nearest-neighbor cavities are weak, then a single photon with a resonant wave vector can be trapped in the region between the two frequency-tunable cavities. In this case, a quantum supercavity can be formed by these two frequency-tunable cavities. We also study how to apply this photon transport control to an array of coupled superconducting transmission line resonators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sputter coating of Nb₃Sn into SRF cavity using stoichiometric target

Nb₃Sn has emerged as a leading alternative material due to its higher superconducting critical temperature (Tc) and superheating field (Hsh), promising a viable solution to the intrinsic performance limit currently faced by Nb superconducting radiofrequency (SRF) cavities. We sputter-coated Nb₃Sn inside Nb SRF cavity using a stoichiometric Nb₃Sn tube target in a DC cylindrical magnetron sputter coater. The target was fabricated by growing an estimated >20 μm thick Nb₃Sn layer on a Nb tube via Sn vapor diffusion using Jefferson Lab’s coating system. Approximately 150 nm thick Nb-Sn films were sputter-deposited onto flat Nb samples at positions representing the beam tubes and equator of a 2.6 GHz Nb cavity. Post-deposition annealing at 950 °C for 3 h resulted in the formation of Nb₃Sn. Microstructural analysis of the annealed films was carried out to investigate the morphology and structure of the Nb₃Sn films. Later, a 2.6 GHz Nb SRF cavity was coated with a ~1.2 μm thick sputtered Nb-Sn film using a stoichiometric Nb₃Sn target, followed by annealing. Cryogenic RF testing of the annealed cavity demonstrated a Tc of 17.8 K, indicating the formation of Nb₃Sn. After a light Sn recoating treatment, the cavity achieved a quality factor (Q0) of 6.7E+08 at lower field at 2.0 K.

Accelerator Physics↗

Progress on the Development of a Superconducting Connection for Niobium Cavities

The availability of a superconducting connection between adjacent niobium radio-frequency (RF) cavities with the capability to carry up to 30 mT of the magnetic flux would be particularly of great benefit to layouts of long accelerators like the International Linear Collider (ILC). It would shorten the distances between structures and therefore the total length of an accelerator with the associated cost reductions. In addition, the superconducting connection would be ideal for a superstructure – two multi-cell cavities connected through a half wavelength long beam pipe providing the coupling. Two single-cell niobium cavities have been designed with Nb-1Zr flanges welded to one of the irises to allow a connection between them with a niobium gasket. A transition to the normal-conducting state of the connection due to the applied RF field causes a reduction of the cavities’ quality factor. The cavity design will be presented in this contribution along with possible choices of materials for the joint.

43 PARTICLE ACCELERATORS↗

Analysis of coupled-bunch instabilities for the NSLS-II storage ring with a 500MHz 7-cell PETRA-III cavity

The NSLS-II storage ring is designed to operate with superconducting RF-cavities with the aim to store an average current of 500 mA distributed in 1080 bunches, with a gap in the uniform filling for ion clearing. At the early stage of the commissioning (phase 1), characterized by a bare lattice without damping wigglers and without Landau cavities, a normal conducting 7-cell PETRA-III RF-cavity structure has been installed with the goal to store an average current of 25 mA. In this paper we discuss our analysis of coupled-bunch instabilities driven by the Higher Order Modes (HOMs) of the 7-cell PETRA-III RF-cavity. As a cure of the instabilities, we apply a well-known scheme based on a proper detuning of the HOMs frequencies based upon cavity temperature change, and the use of the beneficial effect of the slow head–tail damping at positive chromaticity to increase the transverse coupled-bunch instability thresholds. In addition, we discuss measurements of coupled-bunch instabilities observed during the phase 1 commissioning of the NSLS-II storage ring. In our analysis we rely, in the longitudinal case, on the theory of coupled-bunch instability for uniform fillings, while in the transverse case we complement our studies with numerical simulations with OASIS, a novel parallel particle tracking code for self-consistent simulations of collective effects driven by short and long-range wakefields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗