Mars hard lander capsule study. Volume 4 - Capsule point designs and supporting analysis, book 1 Final report
Design and performance characteristics of Mars hard lander capsule point designs, and criteria and mission constraints for capsules 1 and 2
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Design and performance characteristics of Mars hard lander capsule point designs, and criteria and mission constraints for capsules 1 and 2
The detailed preparation required in attempting a mission of the magnitude and scope of PROJECT MERCURY obviously cannot and need not be covered in a document of the handbook type. Prior to any actual attempt to launch a manned capsule, many weeks will be spent in an extensive training and familiarization program. The information contained in this manual, therefore, will pre-suppose a detailed knowledge of the capsule systems and will be confined, for the most part, to procedural data.
Science Capsule captures the processing and data life cycle across machines, organizations, people, and science domains. Our approach combines user engagement methods from social sciences with innovations in workflow and data management.
Analytical design data for capsules 3 and 4 in the Mars hard lander study system
Engineering design of Mars hard lander capsules 5 and 6 and illustrations for increasing payload size
Mission lander maps for parametric data, entry aeroshell, and parachute subsystem used in Mars hard lander study
Parametric analysis of Mars hard lander and preentry subsystems - computer programs for systems analyses
Supporting data for mission planning and design criteria of Mars hard landing system
Features of chemically reacting separated hypersonic flows are identified and issues concerning their analysis and simulation are discussed. Emphasis is placed on flows of high temperature dissociating and ionizing air and current methods for studying and characterizing these flows, including separation, are reviewed. The aeroassist orbital transfer vehicle and its flight trajectory are used for illustration. Thermochemical nonequilibrium phenomena are emphasized and extension of continuum analysis to the high altitude slip-flow regime is considered.
Explore the source record for details and available documents.
The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s second irradiation experiment (AGR-2) was irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) from June 2010 to October 2013 (Collin 2014). The fuel compacts in this experiment held either tristructural isotropic (TRISO)-coated spherical kernels of uranium oxide (UO2) or TRISO-coated kernels containing both uranium carbide and uranium oxide phases (UCO). There were six separately monitored and controlled capsules in the AGR-2 test train. Capsule 3 held twelve compacts containing UO2-TRISO particles fabricated by BWX Technologies Nuclear Operations Group. The AGR-2 TRISO particles were fabricated in a pilot-scale fluidized-bed chemical vapor deposition (FB-CVD) furnace with a coating chamber inner diameter of 150 mm (Phillips, Barnes, and Hunn 2010), which was a change from the first irradiation experiment (AGR-1) particles that had been coated in a lab-scale FB-CVD coating system with a chamber inner diameter of 50 mm (Lowden 2006). The TRISO particles were overcoated with resinated graphite flake at Oak Ridge National Laboratory (ORNL), and the overcoated particles were pressed into one-inch-long, half-inch-diameter cylinders (Hunn, Montgomery, and Pappano 2010). Each cylindrical compact held an average of 1,543 TRISO particles with 9.6% enriched UO2 kernels that had a nominal diameter of 500 μm (Hunn, Savage, and Silva 2012). Capsule 3 compacts were irradiated to average calculated burnups of 9.01–10.69% fissions per initial metal atom (FIMA), and the average calculated fluences of fast neutrons with energies E n > 0.18 MeV were 3.05–3.53×10 25 n/m 2 (Sterbentz 2014). The calculated time-average, volume-average Capsule 3 compact temperatures were 996–1,062°C. However, Capsule 3 compact temperatures varied several hundred degrees across each compact, and the timeaverage minimum (TA min ) and time-average maximum (TA max ) temperatures were between 889–999°C and 1,072–1,105°C, respectively (Hawkes 2014). After irradiation, the AGR-2 test train was transferred from ATR to the INL Materials and Fuels Complex for inspection and disassembly (Ploger, Demkowicz, and Harp 2015). The initial inspection included dimensional metrology of the compacts and graphite fuel holders. Like all the AGR-2 compacts, the compacts in Capsule 3 shrank slightly during irradiation, as expected, with an average length reduction of 1.07–1.24% and an average diameter reduction of 0.13–0.41%. Post-irradiation examination (PIE) of the capsule components was completed to measure select fission products ( 90 Sr, 110m Ag, 134 Cs, 137 Cs, 144 Ce, and 154 Eu) outside the compacts (Stempien and Demkowicz 2020). This involved gamma counting of the graphite and graphoil spacers at the top and bottom of each capsule, acid leaching for radiochemical analysis of fission products on the metallic capsule components, and burn-leach analysis of the graphite holders. The total amount of 110mAg measured on the Capsule 3 components was 13% of the calculated capsule inventory. This was significantly lower than the amount of 110m Ag measured on the three UCO capsule components, which ranged from 32–70%. The lower 110m Ag release in Capsule 3 was likely due to lower peak temperatures compared with the UCO fuel capsules (Hawkes 2014). Measured inventories of the other select fission products were also lower in Capsule 3.
Embodiments of the invention include capsules for containing medical implants and delivery systems for release of active biological substances into a host body. Delivery systems comprise a capsule comprising an interior enclosed by walls, and a source of active biological substances enclosed within the capsule interior, wherein the active biological substances are free to diffuse across the capsule walls. The capsule walls comprise a continuous mesh of biocompatible fibers and a seal region where two capsule walls overlap. The interior of the capsule is substantially isolated from the medium surrounding the capsule, except for diffusion of at least one species of molecule between the capsule interior and the ambient medium, and prevents cell migration into or out of the capsule. Methods for preparing and using the capsules and delivery systems are provided.
Purpose: Microvascular invasion (MVI), which is difficult to diagnose before surgery, is a major factor affecting postoperative recurrence in patients with hepatocellular carcinoma (HCC). The relationship between the radiological tumor capsule and MVI is controversial. This study aimed to evaluate the association between the tumor capsule and MVI. Methods: We searched Medline (by PubMed) and Embase (by OvidSP). Two review authors independently screened titles and abstracts, selected studies about MVI prediction with radiologic tumor capsule and studies with enough data for extracted, assessed the methodological quality and collected data. Summary results were presented as the diagnostic odds ratio (DOR), sensitivity, specificity, and 95% confidence interval. Results: Fifteen studies with 2038 patients were included; fourteen studies, including 1331 patients, with no significant heterogeneity indicated no relationship between absent tumor capsule and MVI [DOR = 0.90 (0.64, 1.26)]. Six studies, including 541 patients, with no significant heterogeneity showed incomplete capsule could be used to predict MVI of HCC preoperatively [DOR = 1.85 (1.13, 3.04)]. The overall sensitivity and specificity estimate were 0.50 (0.37, 0.64) and 0.64 (0.53, 0.74), respectively. Eight studies, including 1349 patients, with highly significant heterogeneity revealed that complete capsule could be a protective factor for MVI [DOR = 1.97 (1.01, 3.86)]. Conclusions: For MVI of HCC, incomplete tumor capsule is a risk factor, while a complete tumor capsule might be a protective factor. However, absent capsule doesn’t show significant relationship with MVI. This might be due to combination of the risk and protective effects of present capsule in MVI.
A major current challenge of the inertial confinement fusion (ICF) campaign is implosion perturbation due to fuel capsule support. Our current approach to hold ICF fuel capsules inside hohlraums is to sandwich a capsule between two thin polymeric films, referred to as tents. In addition to tents, variants of thin fibers have been used in some target designs to hold the capsule. Both tents and fibers cause strong implosion perturbations. An ideal solution to this problem is to hold the capsule inside the hohlraum by levitation, eliminating the perturbation-causing mechanical support. The goal of this project was to demonstrate a path to such an ideal capsule support solution based on quantum (superconducting) levitation. In our approach, the outer surface of the capsule is coated with a thin (about 100 nm) superconducting layer of MgB2, which is currently the most promising superconducting material candidate for this application. Magnetic coils outside the hohlraum are used to levitate and position the capsule in the center of the hohlraum. The scope of this project was limited to the first and arguably most critical step toward quantum levitation of ICF fuel capsules: the demonstration of thin-film superconductor coatings through a better understanding of the physics of defect- and interface-dominated superconducting behavior of ultrathin films. Specific objectives were (i) to develop a method for deposition of smooth and uniform thin films of MgB2 on ICF-scale spherical capsules; (ii) to better understand effects of film thickness, interfaces, and lattice defects on superconducting properties of MgB2; (iii) to perform cryogenic levitation experiments; and (iv) to develop a levitation model. All these objectives were met.
Located on the shores of Lake Michigan, the Palisades Nuclear Generating Station (PNGS) was a nuclear power plant that operated in Covert Township, Michigan. The plant had a single pressurized water reactor that produced electricity for the region. The PNGS was shut down in 2022 after more than four decades of service. The PNGS included in its surveillance program a surveillance capsule, designated A-60, containing specimens of a weld metal with nickel content of about 1.36 wt% and copper content of about 0.20 wt%. The capsule was removed from its surveillance position in the early 1995 and has been resident in the spent fuel pool since that time. This capsule was irradiated to a fluence of 1.87×10 20 n/cm 2 (E> 1MeV) that is equivalent for more than 120 effective full power year (EFPY) for the US reactor pressure vessel (RPV) fleet. The material is also of special interest because of its very high nickel content and potential for development of NiMnSi (nickel-manganese-silicon) precipitates. Combination of very high fluence and very high Ni and Cu content makes the material in this capsule of the great interest as benchmark for currently developing embrittlement trend curves (ETC) aiming to predict embrittlement at high fluences. Thus, several years ago the Light Water Reactor Sustainability Program (LWRSP) initiated negotiations with Entergy to harvest this high fluence capsule since it did not present any regulatory interest for PNGS but could play a very important role for LWRSP efforts for developing ETC for very long-term operation. The negotiations resumed once PNGS ownership moved to the Holtec International in June 2022 which was very supportive to the LWRSP efforts to harvest the A-60 capsule from the spent fuel pool. As a result, the contract was placed with the Westinghouse Electric Company (WEC) to come to PNGS site, retrieve the A-60 capsule, bring it to WEC Churchill hot cell facility, open the capsule and send all surveillance specimens in the capsule to ORNL for future characterization. These specimens from the PNGS A-60 capsule have arrived to ORNL in July 2023 and this report summarizes activities to retrieve and deliver specimens to ORNL site for future evaluation.
The High Flux Isotope Reactor (HFIR) is an ideal tool for materials irradiation testing because of its intense steady-state neutron flux. Many programs take advantage of HFIR’s central flux trap for irradiation experiments using capsules, also known as rabbits, to support advanced materials development and reactor design. The facility that makes up the HFIR flux trap has recently undergone a design change that increases the HFIR primary coolant volumetric flow rate by removing restrictions in the system. As a result, the usable cross-sectional area within the facility increased, opening the door to increase the cross-sectional area of the rabbit capsules that fill the facility. This report documents a new large-diameter rabbit housing that increases the usable volume within the rabbit capsule by 22.6%. However, challenges arise with increasing the capsule size, such as establishing a new maximum capsule operating pressure and determining the thermal-hydraulic characteristics. This report addresses those challenges with previously adopted HFIR safety methods. The rupture pressure of the rabbit housings is demonstrated while verifying that capsule swelling during and after rupture will not block coolant flow. Then, a safety factor is applied to ascertain an administrative operating pressure. Additionally, the thermal-hydraulic performance of the HFIR facility filled with large-diameter rabbit capsules is shown to not violate previously determined safety criteria. Next, heat transfer coefficients are determined for use in design calculations. Furthermore, this report gives an example of internal configurations for the new, larger rabbit capsules that use relevant boiling water reactor (BWR) cladding geometry. Finally, this report documents an example thermal design performance for a rabbit capsule containing six gauge-curved tensile tube specimens. The thermal performance gives predicted temperature distributions within the capsule and shows the expected temperature of the passive thermometers for post-irradiation temperature comparisons.
The High Flux Isotope Reactor (HFIR) is an ideal tool for materials irradiation testing because of its intense steady-state neutron flux. Many programs take advantage of HFIR’s central flux trap for irradiation experiments using capsules, also known as rabbits, to support advanced materials development and reactor design. The facility that makes up the HFIR flux trap has recently undergone a design change that increases the HFIR primary coolant volumetric flow rate by removing restrictions in the system. As a result, the usable cross-sectional area within the facility increased, opening the door to increase the cross-sectional area of the rabbit capsules that fill the facility. This report documents a new large-diameter rabbit housing that increases the usable volume within the rabbit capsule by 22.6%. However, challenges arise with increasing the capsule size, such as establishing a new maximum capsule operating pressure and determining the thermal-hydraulic characteristics. This report addresses those challenges with previously adopted HFIR safety methods. The rupture pressure of the rabbit housings is demonstrated while verifying that capsule swelling during and after rupture will not block coolant flow. Then, a safety factor is applied to ascertain an administrative operating pressure. Additionally, the thermal-hydraulic performance of the HFIR facility filled with large-diameter rabbit capsules is shown to not violate previously determined safety criteria. Next, heat transfer coefficients are determined for use in design calculations. Furthermore, this report gives an example of internal configurations for the new, larger rabbit capsules that use relevant boiling water reactor (BWR) cladding geometry. Finally, this report documents an example thermal design performance for a rabbit capsule containing six gauge-curved tensile tube specimens. The thermal performance gives predicted temperature distributions within the capsule and shows the expected temperature of the passive thermometers for post-irradiation temperature comparisons.