Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cancer detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles

Abstract Purpose Intraoperative detection and removal of microscopic residual disease (MRD) remain critical to the outcome of cancer surgeries. Today’s minimally invasive surgical procedures require miniaturization and surgical integration of highly sensitive imagers to seamlessly integrate into the modern clinical workflow. However, current intraoperative imagers remain cumbersome and still heavily dependent on large lenses and rigid filters, precluding further miniaturization and integration into surgical tools. Procedures We have successfully engineered a chip-scale intraoperative micro-imager array—without optical filters or lenses—integrated with lanthanide-based alloyed upconverting nanoparticles (aUCNPs) to achieve tissue imaging using a single micro-chip. This imaging platform is able to leverage the unique optical properties of aUCNPs (long luminescent lifetime, high-efficiency upconversion, no photobleaching) by utilizing a time-resolved imaging method to acquire images using a 36-by-80-pixel, 2.3 mm $$\times$$ × 4.8 mm silicon-based electronic imager micro-chip, that is, less than 100-µm thin. Each pixel incorporates a novel architecture enabling automated background measurement and cancellation. We have validated the performance, spatial resolution, and the background cancellation scheme of the imaging platform, using resolution test targets and mouse prostate tumor sample intratumorally injected with aUCNPs. To demonstrate the ability to image MRD, or tumor margins, we evaluated the imaging platform in visualizing a single-cell thin section of the injected prostate tumor sample. Results Tested on USAF resolution targets, the imager is able to achieve a resolution of 71 µm. We have also demonstrated successful background cancellation, achieving a signal-to-background ratio of 8 when performing ex vivo imaging on aUCNP-injected prostate tumor sample, improved from originally 0.4. The performance of the imaging platform on single-cell layer sections was also evaluated and the sensor achieved a signal-to-background ratio of 4.3 in resolving cell clusters with sizes as low as 200 cells. Conclusion The imaging system proposed here is a scalable chip-scale ultra-thin alternative for bulky conventional intraoperative imagers. Its novel pixel architecture and background correction scheme enable visualization of microscopic-scale residual disease while remaining completely free of lenses and filters, achieving an ultra-miniaturized form factor—critical for intraoperative settings.

59 BASIC BIOLOGICAL SCIENCES↗

Use of Longitudinal Serum Analysis and Machine Learning to Develop a Classifier for Cancer Early Detection

Early detection of solid tumors through a simple screening process, such as the proteomic analysis of biofluids, has the potential to significantly alter the management and outcomes of cancers. The application of advanced targeted proteomics measurements and data analysis strategies to uniformly collected serum or plasma samples would enable longitudinal studies of cancer risk, progression, and response to therapy that have the potential to significantly reduce cancer burden in general. In this article, we describe a generalizable workflow combining robust, multiplexed targeted proteomics measurements applied to longitudinal samples from the Department of Defense Serum Repository with a Random Forest machine learning method for developing and initially evaluating the performance of candidate biomarker panels for early detection of cancers. The effectiveness of this approach was demonstrated in a cohort of 175 head and neck squamous cell carcinoma patients. The outlined protocols include methods for sample preparation, instrument analysis, and data analysis and interpretation using this workflow.

Longitudinal analysis, machine learning, cancer, e↗

Sequentially calibrating a Bayesian microsimulation model to incorporate new information and assumptions

Background: Microsimulation models are mathematical models that simulate event histories for individual members of a population. They are useful for policy decisions because they simulate a large number of individuals from an idealized population, with features that change over time, and the resulting event histories can be summarized to describe key population-level outcomes. Model calibration is the process of incorporating evidence into the model. Calibrated models can be used to make predictions about population trends in disease outcomes and effectiveness of interventions, but calibration can be challenging and computationally expensive. Methods: This paper develops a technique for sequentially updating models to take full advantage of earlier calibration results, to ultimately speed up the calibration process. A Bayesian approach to calibration is used because it combines different sources of evidence and enables uncertainty quantification which is appealing for decision-making. We develop this method in order to re-calibrate a microsimulation model for the natural history of colorectal cancer to include new targets that better inform the time from initiation of preclinical cancer to presentation with clinical cancer (sojourn time), because model exploration and validation revealed that more information was needed on sojourn time, and that the predicted percentage of patients with cancers detected via colonoscopy screening was too low. Results: The sequential approach to calibration was more efficient than recalibrating the model from scratch. Incorporating new information on the percentage of patients with cancers detected upon screening changed the estimated sojourn time parameters significantly, increasing the estimated mean sojourn time for cancers in the colon and rectum, providing results with more validity. Conclusions: A sequential approach to recalibration can be used to efficiently recalibrate a microsimulation model when new information becomes available that requires the original targets to be supplemented with additional targets.

60 APPLIED LIFE SCIENCES↗

Mortality of older construction and craft workers employed at Department of Energy (DOE) nuclear sites: Follow‐up through 2021

Background To determine if construction and trades workers formerly employed at US Department of Energy (DOE) nuclear weapons sites are at significant risk for occupational diseases, we studied the mortality experience of participants in the Building Trades National Medical Screening Program (BTMed). Methods The cohort included 26,922 participants enrolled between 1998 and 2021 and 8367 deaths. Standardized mortality ratios were calculated based on US death rates. Cox models compared construction workers (n = 22,747; 7487 deaths) to two nonconstruction subpopulations: administrative, scientific and security workers (n = 1894; 330 deaths), and all other nonconstruction workers (n = 2218; 550 deaths). Results Mortality was elevated for all causes, all cancers, cancers of the trachea, bronchus, lung, kidneys, and lymphatic and hematopoietic system, mesothelioma, chronic obstructive pulmonary disease (COPD), asbestosis, transportation injuries, and other injuries, particularly accidental poisonings. There were 167 deaths from coronavirus disease 2019 (COVID-19), which was lower than expected using US death rates. Overall cause-specific mortality was significantly higher among construction workers than for internal comparison groups. Conclusions Construction workers employed at DOE sites have a significantly increased risk for occupational illnesses. Apart from COVID-19 deaths, this update: (1) found that mortality among construction workers is significantly elevated compared to the US population and significantly higher than in the internal comparison populations, and (2) confirmed excess risk for these workers for first employment after 1990. Cancer mortality risks are similar to the cancers identified for DOE compensation from radiation exposures. In conclusion, the high lung cancer risk supports the value of early lung cancer detection. Continued medical surveillance is important.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Evaluation of two extraction chromatography resins for scandium and titanium separation for medical isotope production

Scandium-47 ( 47 Sc) can be used in nuclear medicine as a therapeutic-diagnostic, or "theragnostic," radioactive medical isotope for cancer detection and treatment. The 47 Sc isotope can be produced through the photonuclear reaction 48 Ti(γ,p) 47 Sc by irradiating enriched 48 Ti target material. The enriched target material necessary for production is costly; 48 TiO 2 costs ~ $\$$1550/g, and targets can be > 50 g ($\$$77,500) to produce medically relevant amounts of 47 Sc. In order to keep costs low, a highly efficient separation of scandium from bulk titanium is desired, along with efficient methods for recycling the target material. Here this research is focused on evaluating efficient methods for the separation of scandium from bulk quantities of titanium using commercially available diglycolamide-based and hydroxamate-based extraction chromatography resins (DGA resin and ZR resin, respectively). The sorption of 47 Sc and Ti on these resins were investigated at varying concentrations of HNO 3 , HCl, H 2 SO 4 , and HF to explore how they might be used in a large-scale production/processing setting.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MedNAS: Multiscale Training-Free Neural Architecture Search for Medical Image Analysis

Deep neural networks have demonstrated impressive results in medical image analysis, but designing suitable architectures for each specific task is expertise dependent and time consuming. Neural architecture search (NAS) offers an effective means of discovering architectures. It has been highly successful in numerous applications, particularly in natural image classification. Yet, medical images possess unique characteristics, such as small regions and a wide variety of lesion sizes, that differentiate them from natural images. Furthermore, most current NAS methods struggle with high computational costs, especially when dealing with high-resolution image datasets. In this article, we present a novel evolutionary NAS method called multiscale training-free neural architecture search (MSTF-NAS) to address these challenges. Specifically, to accommodate the broad range of lesion region sizes in disease diagnosis, we develop a new reduction cell search space that enables the search algorithm to explicitly identify the optimal scale combination for multiscale feature extraction. Further, to overcome the issue of high computational costs, we utilize training-free indicators as performance measures for candidate architectures, which allows us to search for the optimal architecture more efficiently. More specifically, by considering the capability and simplicity of various networks, we formulate a multiobjective optimization problem that involves two training-free indicators and model complexity for candidate architectures. Extensive experiments on a large medical image benchmark and a publicly available breast cancer detection dataset are conducted. The empirical results demonstrate that our MSTF-NAS outperforms both human-designed architectures and current state-of-the-art NAS algorithms on both datasets, indicating the effectiveness of our proposed method.

60 APPLIED LIFE SCIENCES↗

Optical Microsystems for Molecular Sensing (CRADA Final Report)

As part of the Cyclotron Road program, NuSight Photonics sought to implement and investigate an optical Raman spectroscopy instrument for material and molecular analysis. Raman spectroscopy is widely used for quick and non-invasive material measurement when accurate results are needed – e.g., for monitoring manufacturing process in pharmaceutical plants, or identifying illicit substances and explosives by Law Enforcement. This technique is also growing rapidly in popularity as it is applied successfully to a broad range of applications, from pathology and non-invasive early cancer detection, to food and drug safety. The biggest challenge for Raman spectroscopy to achieve its full potential is the hardware cost, ranging from $\$ $25k to $\$ $250k, with the lower cost solutions significantly limited in sensitivity—or detection limit. NuSight Photonics aimed to tackle this obstacle through a novel hardware approach: Swept-Source Raman Spectroscopy.

36 MATERIALS SCIENCE↗

Achieving robust somatic mutation detection with deep learning models derived from reference data sets of a cancer sample

Accurate detection of somatic mutations is challenging but critical in understanding cancer formation, progression, and treatment. We recently proposed NeuSomatic, the first deep convolutional neural network-based somatic mutation detection approach, and demonstrated performance advantages on in silico data. In this study, we use the first comprehensive and well-characterized somatic reference data sets from the SEQC2 consortium to investigate best practices for using a deep learning framework in cancer mutation detection. Using the high-confidence somatic mutations established for a cancer cell line by the consortium, we identify the best strategy for building robust models on multiple data sets derived from samples representing real scenarios, for example, a model trained on a combination of real and spike-in mutations had the highest average performance. The strategy identified in our study achieved high robustness across multiple sequencing technologies for fresh and FFPE DNA input, varying tumor/normal purities, and different coverages, with significant superiority over conventional detection approaches in general, as well as in challenging situations such as low coverage, low variant allele frequency, DNA damage, and difficult genomic regions.

59 BASIC BIOLOGICAL SCIENCES↗

Dual modality endocavity biopsy imaging system and method

A dual modality endocavity imaging and treatment system for detection of cancer and targeted biopsy and treatment procedures, comprising: a housing; a nuclear detector system housed within the housing and configured for detecting nuclear radiation imaging data; an ultrasound detector system housed within the housing for detecting ultrasound imaging data; a needle associated with the housing and adjustably positionable relative thereto; and a data processing module configured to receive the nuclear radiation imaging data and the ultrasound imaging data and to generate and output an image showing the relative position of the needle and an endocavity object of interest. The needle may include a distinct radiation signature to facilitate imaging thereof.

Lall, Terrence↗

Efficient Synthesis and HPLC-Based Characterization for Developing Vanadium-48-Labeled Vanadyl Acetylacetonate as a Novel Cancer Radiotracer for PET Imaging

Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac) 2 ], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 ( 48 V) generated with a compact medical cyclotron has been used to label VO(acac) 2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac) 2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac) 2 , [ 48 V]VO(acac) 2 , and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [ 48 V]VO(acac) 2 . Preliminary results of preclinical, small-animal PET studies are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Implications of MRI-Detected EMVI and Tumor Deposits and Their Response to Neoadjuvant Therapy in cT3 and cT4 Rectal Cancer

Magnetic resonance imaging–detected extramural venous invasion (mrEMVI) and tumor deposits (TDs) are risk factors for the development of local recurrence and distant metastases (DMs) in rectal cancer. However, little is known about their response to neoadjuvant treatment and its relation to oncologic outcomes. This study evaluated the incidence and features of mrEMVI and TDs before and after neoadjuvant treatment in relation to the development of local recurrence and DMs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Data Summarization and Inference at Scale

This is the final report for the DOE ASCR grant SC-0022260, Data Summarization and Inference at Scale, PI: Alex Pothen, Purdue University. The goal of the project was to solve data-intensive and compute-intensive problems in the physical sciences, engineering, information science, data science, etc. by designing and implementing new algorithms that could work with a subset of the data. The four subgoals were: (a) The solution of problems where the data is too large to be stored in the memory of a computer. In this streaming model of computation, the data arrives as a stream of elements to the computer, each element is processed as it arrives, and a decision is made to discard the data or to store it; only a small subset of the data proportional to the size of the output solution is stored, and when all the data has been streamed, a solution to the problem is computed from the stored subset. (b) The use of machine learning methods to compute solutions to data-intensive problems. The use of GPUs is critical to obtain high performance on machine learning tasks, but their memory sizes are smaller relative to that of CPUs. For large-scale problems, the data is sampled many times, and small samples are used with repetition, for robustness, to compute solutions to inference tasks. This sampling reduces the memory required to solve the problem, but attention is needed to avoid slow convergence to the solutions, and reduced accuracy of inference. We propose submodular optimization, Large Language Models, and physics-informed neural networks to enable GPU computations here. (c) Modeling and visualization of high-dimensional data using interpretable features. Clinical proteomic data sets from immunology for the detection of cancer and other diseases are temporal and high-dimensional, and algorithms for visualizing these data sets using clinically interpretable features are lacking. We propose methods that compute distances based on the optimal transportation problem and graph edit distances to address this problem. We also propose the use of optimal transport-based distances, spatial statistics, and network structure to classify image data sets, We apply these algorithms to electron micrographs of the peripheral nervous system in the digestive tract. (d) The design of data-intensive algorithms on emerging architectures, specifically, noisy, intermediate-scale quantum (NISQ) devices. Quantum computers offer the possibility of exploring large solution spaces due to the principle of superposition, but current quantum computers are limited by few qubits, short coherence times due to noise, poor interconections among the qubits, etc. We propose the use of the divide and conquer paradigm to solve large-scale problems, wherein collections of small subproblems are solved on the quantum devices, and the solutions to the subproblems are integrated into a solution for the original problem on a classical computer.

97 MATHEMATICS AND COMPUTING↗

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗

In-Depth Proteome Profiling of Small Extracellular Vesicles Isolated from Cancer Cell Lines and Patient Serum

Extracellular Vesicle (EV) secretion has been observed from most types of normal and tumor cells. These EVs contain a variety of distinctive cargo where tumor-derived serum proteins in EVs secreted into the bloodstream can be used to provide a minimally invasive method for clinical monitoring. We have therefore undertaken a comprehensive study of the protein content of the EVs from several cancer cell lines using direct Data Independent Analysis (DIA). Further, several thousand proteins were detected including many of the classic EV markers such as CD9, CD81, CD63, TSG101 and Syndecan-1 among others. Many distinctive cancer related proteins were detected and some of them are known to be potential markers of cancer detection and monitoring of cancer progression. We have further studied the protein content of EVs from patient serum for both normal controls and pancreatic (PC) and Hepatocellular Carcinoma (HCC) cancers. The EVs for these studies have been isolated by various methods for comparison including ultracentrifugation (UC) and CD9 immunoaffinity column (CD9-IC). Typically, 500-1,000 proteins were identified where most of them overlapped with the EV proteins identified from the cell lines studied. Many of the EV protein markers were identified in these serum EVs and large numbers of proteins related to pancreatic and HCC cancers were identified.

60 APPLIED LIFE SCIENCES↗

Artificial intelligence to unlock real-world evidence in clinical oncology: A primer on recent advances

Purpose: Real world evidence is crucial to understanding the diffusion of new oncologic therapies, monitoring cancer outcomes, and detecting unexpected toxicities. In practice, real world evidence is challenging to collect rapidly and comprehensively, often requiring expensive and time-consuming manual case-finding and annotation of clinical text. In this Review, we summarise recent developments in the use of artificial intelligence to collect and analyze real world evidence in oncology. Methods: We performed a narrative review of the major current trends and recent literature in artificial intelligence applications in oncology. Results: Artificial intelligence (AI) approaches are increasingly used to efficiently phenotype patients and tumors at large scale. These tools also may provide novel biological insights and improve risk prediction through multimodal integration of radiographic, pathological, and genomic datasets. Custom language processing pipelines and large language models hold great promise for clinical prediction and phenotyping. Conclusions: Despite rapid advances, continued progress in computation, generalizability, interpretability, and reliability as well as prospective validation are needed to integrate AI approaches into routine clinical care and real-time monitoring of novel therapies.

60 APPLIED LIFE SCIENCES↗

Cancer survival in the United States 2007–2016: Results from the National Program of Cancer Registries

Background Cancer survival has improved for the most common cancers. However, less improvement and lower survival has been observed in some groups perhaps due to differential access to cancer care including prevention, screening, diagnosis, and treatment. Methods To further understand contemporary relative cancer survival (one- and five- year), we used survival data from CDC’s National Program of Cancer Registries (NPCR) for cancers diagnosed during 2007–2016. We examined overall relative cancer survival by sex, race and ethnicity, age, and county-level metropolitan and non-metropolitan status. Relative cancer survival by metropolitan and non-metropolitan status was further examined by sex, race and ethnicity, age, and cancer type. Results Among persons with cancer diagnosed during 2007–2016 the overall one-year and five-year relative survival was 80.6% and 67.4%, respectively. One-year relative survival for persons living in metropolitan counties was 81.1% and 77.8% among persons living in non-metropolitan counties. We found that persons who lived in non-metropolitan counties had lower survival than those who lived in metropolitan counties, and this difference persisted across sex, race and ethnicity, age, and most cancer types. Conclusion Further examination of the differences in cancer survival by cancer type or other characteristics might be helpful for identifying potential interventions, such as programs that target screening and early detection or strategies to improve access to high quality cancer treatment and follow-up care, that could improve long-term outcomes. Impact This analysis provided a high-level overview of contemporary cancer survival in the United States.

60 APPLIED LIFE SCIENCES↗