Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Instrumental Response Model and Detrending for the Dark Energy Camera

We describe the model for mapping from sky brightness to the digital output of the Dark Energy Camera (DECam) and the algorithms adopted by the Dark Energy Survey (DES) for inverting this model to obtain photometric measures of celestial objects from the raw camera output. This calibration aims for fluxes that are uniform across the camera field of view and across the full angular and temporal span of the DES observations, approaching the accuracy limits set by shot noise for the full dynamic range of DES observations. The DES pipeline incorporates several substantive advances over standard detrending techniques, including principal-components-based sky and fringe subtraction; correction of the "brighter-fatter" nonlinearity; use of internal consistency in on-sky observations to disentangle the influences of quantum efficiency, pixel-size variations, and scattered light in the dome flats; and pixel-by-pixel characterization of instrument spectral response, through combination of internal-consistency constraints with auxiliary calibration data. This article provides conceptual derivations of the detrending/calibration steps, and the procedures for obtaining the necessary calibration data. Other publications will describe the implementation of these concepts for the DES operational pipeline, the detailed methods, and the validation that the techniques can bring DECam photometry and astrometry within $\approx 2$ mmag and $\approx 3$ mas, respectively, of fundamental atmospheric and statistical limits. In conclusion, the DES techniques should be broadly applicable to wide-field imagers.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast image acquisition system and method using pulsed light illumination and sample scanning to capture optical micrographs with sub-micron features

An optical inspection system for detecting sub-micron features on a sample component. The system may have a controller, a camera responsive to the controller for capturing images, an objective lens able to capture submicron scale features on the sample component, and a pulsed light source. The pulsed light source may be used to generate light pulses. The camera may be controlled to acquire images, using the objective lens, only while the pulsed light source is providing light pulses illuminating a portion of the sample component. Relative movement between the sample component and the objective lens is provided to enable at least one of a desired subportion or an entirety of the sample component to be scanned with the camera.

Yoo, Jae Hyuck↗

SU-F-BRA-16: Development of a Radiation Monitoring Device Using a Low-Cost CCD Camera Following Radionuclide Therapy

Purpose: It is now commonplace to handle treatments of hyperthyroidism using iodine-131 as an outpatient procedure due to lower costs and less stringent federal regulations. The Nuclear Regulatory Commission has currently updated release guidelines for these procedures, but there is still a large uncertainty in the dose to the public. Current guidelines to minimize dose to the public require patients to remain isolated after treatment. The purpose of this study was to use a low-cost common device, such as a cell phone, to estimate exposure emitted from a patient to the general public. Methods: Measurements were performed using an Apple iPhone 3GS and a Cs-137 irradiator. The charge-coupled device (CCD) camera on the phone was irradiated to exposure rates ranging from 0.1 mR/hr to 100 mR/hr and 30-sec videos were taken during irradiation with the camera lens covered by electrical tape. Interactions were detected as white pixels on a black background in each video. Both single threshold (ST) and colony counting (CC) methods were performed using MATLAB®. Calibration curves were determined by comparing the total pixel intensity output from each method to the known exposure rate. Results: The calibration curve showed a linear relationship above 5 mR/hr for both analysis techniques. The number of events counted per unit exposure rate within the linear region was 19.5 ± 0.7 events/mR and 8.9 ± 0.4 events/mR for the ST and CC methods respectively. Conclusion: Two algorithms were developed and show a linear relationship between photons detected by a CCD camera and low exposure rates, in the range of 5 mR/hr to 100-mR/hr. Future work aims to refine this model by investigating the dose-rate and energy dependencies of the camera response. This algorithm allows for quantitative monitoring of exposure from patients treated with iodine-131 using a simple device outside of the hospital.

60 APPLIED LIFE SCIENCES↗

Infrared Cloud Imager Instrument Intercomparison Report

The Infrared Cloud Imager Instrument Intercomparison was a guest instrument deployment by NWB Sensors to the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) User Facility observatory on the Southern Great Plains (SGP) between May 18 and December 12, 2023. NWB Sensors is a company that has developed a commercially available infrared cloud imager (ICI). The ICI provides radiometrically calibrated, full-sky images of the downwelling infrared radiance in the 7.3-14 µm band. In addition, it provides cloud radiance as the residual between the observed radiance and the modeled cloud-free radiance as well as derived cloud products. The instrument is used in applications that require consistent detection of clouds across day and night. For more information, consult the instrument's webpage. The primary goal of the deployment was to validate the radiometric accuracy of the ICI. The ICI uses a proprietary calibration method to convert the raw data from its infrared camera into downwelling radiance. Unlike similar instruments, the system does not have an onboard blackbody calibration standard. Instead, NWB Sensors characterizes each ICI camera individually in an environmental chamber while looking at a blackbody standard. The resulting (proprietary) calibration is used operationally in the instrument and has been demonstrated to be stable over long periods. To validate the radiometric products from the ICI, an intercomparison between the ICI data products and those from ARM’s atmospheric emitted radiance interferometer (AERI) was made. The AERI is a best-in-class instrument for measuring downwelling infrared radiance (Gero et al. 2025). A weighted integration of the AERI’s spectral radiances across the ICI’s camera response was performed. The resulting radiance (herein called the AERI radiance) was directly compared to the zenith radiance concurrently observed by the ICI. The results of these comparisons are reported in the next section of this report.

54 ENVIRONMENTAL SCIENCES↗

Anger Camera Firmware

The firmware is responsible for the operation of Anger Camera Electronics, calculation of position, time of flight and digital communications. It provides a first stage analysis of 48 signals from 48 analog signals that have been converted to digital values using A/D convertors.

Source record↗

Photometric Characterization of the Dark Energy Camera

We characterize the variation in photometric response of the Dark Energy Camera (DECam) across its 520 Mpix science array during 4 years of operation. These variations are measured using high signal-to-noise aperture photometry of >10 7 stellar images in thousands of exposures of a few selected fields, with the telescope dithered to move the sources around the array. A calibration procedure based on these results brings the rms variation in aperture magnitudes of bright stars on cloudless nights down to 2–3 mmag, with <1 mmag of correlated photometric errors for stars separated by ≥20''. On cloudless nights, any departures of the exposure zeropoints from a secant airmass law exceeding 1 mmag are plausibly attributable to spatial/temporal variations in aperture corrections. These variations can be inferred and corrected by measuring the fraction of stellar light in an annulus between 6'' and 8'' diameter. Key elements of this calibration include: correction of amplifier nonlinearities; distinguishing pixel-area variations and stray light from quantum-efficiency variations in the flat fields; field-dependent color corrections; and the use of an aperture-correction proxy. The DECam response pattern across the 2° field drifts over months by up to ±9 mmag, in a nearly wavelength-independent low-order pattern. Here, we find no fundamental barriers to pushing global photometric calibrations toward mmag accuracy.

79 ASTRONOMY AND ASTROPHYSICS↗

A gain series method for accurate EMCCD calibration

Abstract Calibration of the gain and digital conversion factor of an EMCCD is necessary for accurate photon counting. We present a new method to quickly calibrate multiple gain settings of an EMCCD camera. Acquiring gain-series calibration data and analyzing the resulting images with the EMCCD noise model more accurately estimates the gain response of the camera. Furthermore, we develop a method to compare the results from different calibration approaches. Gain-series calibration outperforms all other methods in this self-consistency test.

36 MATERIALS SCIENCE↗

Fast quantum ghost imaging with a single-photon-sensitive time-stamping camera

Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.

Mavian, Alex (ORCID:0000000279448830)↗

Experiment Based Superposition Thermal Modeling of Laser Powder Bed Fusion

This paper evaluates experiment-based superposition thermal modeling for Laser Powder Bed Fusion (LPBF) with a pulsed laser. An analytical pulsed laser thermal model establishes the modeling procedure. The framework inverts a powder bed’s single pulse temperature response from experimental spatiotemporal Short-Wave Infrared (SWIR) camera data. Superimposing this response along a scan path simulates multi-pulse LPBF. Results show the experimentally informed superposition model rapidly and accurately predicts a layer’s temperature history. The model has applications in correction of thermally driven LPBF errors and in-situ part qualification.

Lough, Cody↗

A New Method for Aerosol Measurement Using Wide-field Photometry

We present a new method to measure the vertical aerosol optical depth (VAOD) during clear nights using a wide-field imager—a CCD camera with a photographic lens on an equatorial mount. A series of 30 s exposures taken at different altitudes above the horizon can be used to measure the VAOD with a precision better than 0.008 optical depths within a few minutes. Such a measurement does not produce any light and is thus suitable for use at sites where other astronomical instruments are located. The precision of the VAOD measurement depends on the laboratory calibration of spectral properties of the system and of the response of the camera electronics to varying illumination levels, as well as careful considerations of the details of stellar photometry and modeling of the dependence of the measured stellar flux, the star color, and the position within the field of view. The results obtained with robotic setups at the future sites of the Cerenkov Telescope Array show good internal consistency and agreement with simultaneous measurements from a Sun/Moon photometer located at the same sites.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-premixed acoustically perturbed swirling flame dynamics

An investigation into the response of non-premixed swirling flames to acoustic perturbations at various frequencies (f{sub p}=0-315 Hz) and swirl intensities (S=0.09 and 0.34) is carried out. Perturbations are generated using a loudspeaker at the base of an atmospheric co-flow burner with resulting velocity oscillation amplitudes vertical stroke u'/U{sub avg} vertical stroke in the 0.03-0.30 range. The dependence of flame dynamics on the relative richness of the flame is investigated by studying various constant fuel flow rate flame configurations. Flame heat release rate is quantitatively measured using a photomultiplier with a 430 nm bandpass filter for observing CH* chemiluminescence which is simultaneously imaged with a phase-locked CCD camera. The flame response is observed to exhibit a low-pass filter characteristic with minimal flame response beyond pulsing frequencies of 200 Hz. Flames at lower fuel flow rates are observed to remain attached to the central fuel pipe at all acoustic pulsing frequencies. PIV imaging of the associated isothermal fields show the amplification in flame aspect ratio is caused by the narrowing of the inner recirculation zone (IRZ). Good correlation is observed between the estimated flame surface area and the heat release rate signature at higher swirl intensity flame configurations. A flame response index analogous to the Rayleigh criterion in non-forced flames is used to assess the potential for a strong flame response at specific perturbation configurations and is found to be a good predictor of highly responsive modes. Phase conditioned analysis of the flame dynamics yield additional criteria in highly responsive modes to include the effective amplitude of velocity oscillations induced by the acoustic pulsing. In addition, highly responsive modes were characterized by velocity to heat release rate phase differences in the {+-}{pi}/2 range. A final observed characteristic in highly responsive flames is a Strouhal number between 1 and 3.5 based on the burner co-flow annulus diameter (St = f{sub p}U{sub avg}/d{sub m}). Finally, wavelet analyses of heat release rate perturbations indicate highly responsive modes are characterized by sustained low frequency oscillations which accompany the high amplitude velocity perturbations at these modes. Higher intensity low frequency heat release rate oscillations are observed for lean flame/low pulsing frequency conditions. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-D-204-02: Novel Method for Correcting Degradation of Sharpness of Liquid-Crystal Display Based On Modulation Transfer Function

Purpose: To develop a method for improving sharpness of images reproduced on liquid-crystal displays (LCDs) by compensating for the degradation of modulation transfer function (MTF) of the LCD. Methods: The inherent MTF of a color LCD (display MTF) was measured using a commercially available color digital camera. The frequency responses necessary to compensate for the resolution property of the LCD were calculated from the inverses of the display MTFs in both the horizontal and vertical directions. In addition, the inverses of the display MTFs were combined with the response of the human eye. The finite impulse response (FIR) filters were computed by taking the inverse Fourier transform of the frequency responses, and the effects of the FIR filtering on both the resolution and noise properties of the displayed images were verified by measuring the MTF and Wiener spectrum (WS), respectively. The FIR filtering was then applied to the representation of digital bone and chest radiographs. Results: The FIR filtering improved the MTF values by up to almost 1.0 or greater over the frequency range of interest, while it minimally increased the WS values. Combining the inverses of the display MTFs with the response of the human eye led to further refinement of the MTF. Our method was successfully and beneficially applied to the image interpretation of bone radiographs. The resolution enhancement of chest radiographs, which include larger scattered radiation than bone radiographs, was easily perceived by incorporating the response of the human eye. In addition, no artifacts were observed on the processed images. Conclusion: Our proposed method to compensate for the degradation of the resolution properties of LCDs has the potential to improve the observer performance of radiologists when reading digital radiographs. This work was supported in part by grant from EIZO Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photometry, Centroid and Point-spread Function Measurements in the LSST Camera Focal Plane Using Artificial Stars

Abstract The Vera C. Rubin Observatory’s LSST Camera (LSSTCam) pixel response has been characterized using laboratory measurements with a grid of artificial stars. We quantify the contributions to photometry, centroid, point-spread function size, and shape measurement errors due to small anomalies in the LSSTCam CCDs. The main sources of those anomalies are quantum efficiency variations and pixel area variations induced by the amplifier segmentation boundaries and “tree-rings”—circular variations in silicon doping concentration. This laboratory study using artificial stars projected on the sensors shows overall small effects. The residual effects on point-spread function (PSF) size and shape are below 0.1%, meeting the ten-year LSST survey science requirements. However, the CCD mid-line presents distortions that can have a moderate impact on PSF measurements. This feature can be avoided by masking the affected regions. Effects of tree-rings are observed on centroids and PSFs of the artificial stars and the nature of the effect is confirmed by a study of the flat-field response. Nevertheless, further studies of the full-focal plane with stellar data should more completely probe variations and might reveal new features, e.g., wavelength-dependent effects. The results of this study can be used as a guide for the on-sky operation of LSSTCam.

79 ASTRONOMY AND ASTROPHYSICS↗

An experimental study on the motion, deformation and electrical charging of water drops falling in oil in the presence of high voltage D.C. electric field

The motion, deformation and electrical charging of conducting water drops falling in an insulating liquid subjected to various electric fields strength were studied experimentally. The drop motion was recorded contentiously by high speed camera and their responses to deformation under the influence of electric field were digitally extracted by image processing of the sequential frames. Two parameters were defined for describing the deviation and deformation of the drops under the electric forces. Outcomes depicted that the deviation of the drops from the vertical line would be increased by adding to the applied electrical potential as well as reduction of drop size. Moreover, regarding to deformation diagram, the results revealed a dissimilar deformation manner between large and small drops, which can be helpful in describing the drop-drop electro coalescence phenomena and in design of electrically driven droplet-based systems. (author)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Absolute calibration of optical streak cameras on picosecond time scales using supercontinuum generation

Here we report a new method using high stability, laser-driven supercontinuum generation in a liquid cell to calibrate the absolute photon response of fast optical streak cameras as a function of wavelength when operating at fastest sweep speeds. A stable, pulsed white light source based around the use of self-phase modulation in a salt solution was developed to provide the required brightness on picosecond timescales, enabling streak camera calibration in fully dynamic operation. The measured spectral brightness allowed for absolute photon response calibration over a broad spectral range (425-650nm). Calibrations performed with two Axis Photonique streak cameras using the Photonis P820PSU streak tube demonstrated responses which qualitatively follow the photocathode response. Peak sensitivities were 1 photon/count above background. The absolute dynamic sensitivity is less than the static by up to an order of magnitude. We attribute this to the dynamic response of the phosphor being lower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

U.S. Domestic Security-by-Design: On Site Response Force Strategies

U.S. nuclear power facilities face increasing challenges in meeting dynamic security requirements caused by evolving and expanding threats while keeping cost reasonable to make nuclear energy competitive. The past approach has often included implementing security features after a facility has been designed and without attention to optimization, which can lead to cost overruns. Incorporating security in the design process can provide robust, cost- effective, and sufficient physical protection systems. The purpose of this work is both to develop a framework for the integration of security into the design phase of High Temperature Gas Reactors (HTGRs) that utilize pebble-based fuels and microreactors. Specifically, this effort focuses on integrating security into the design phase of a model HTGR and microreactor that meets current Nuclear Regulatory Commission (NRC) physical protection requirements and providing advanced solutions to improve physical protection and decrease costs. A suite of tools, including SCRIBE3D©, PATHTRACE© and Blender© were used to model a hypothetical, generic domestic HTGR facility and microreactor facility. Physical protection elements such as sensors, cameras, barriers, and onsite response forces were added to the model based on best practices for physical protection systems. Multiple outsider sabotage scenarios were examined with four-to-eight adversaries to determine security metrics. The results of this work will influence physical protection system designs and facility designs for U.S. domestic HTGRs and microreactors. This work will also demonstrate how a series of experimental and modeling capabilities across the Department of Energy (DOE) Complex can lead to efficient security systems that utilize an onsite response force. The conclusions and recommendations in this document may be applicable to all SMR designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterizing the Quantum-Confined Stark Effect in Semiconductor Quantum Dots and Nanorods for Single-Molecule Electrophysiology

We optimized the performance of quantum-confined Stark effect (QCSE)-based voltage nanosensors. A high-throughput approach for single-particle QCSE characterization was developed and utilized to screen a library of such nanosensors. Type-II ZnSe/CdS-seeded nanorods were found to have the best performance among the different nanosensors evaluated in this work. The degree of correlation between intensity changes and spectral changes of the exciton's emission under an applied field was characterized. An upper limit for the temporal response of individual ZnSe/CdS nanorods to voltage modulation was characterized by high-throughput, high temporal resolution intensity measurements using a novel photon-counting camera. The measured 3.5 μs response time is limited by the voltage modulation electronics and represents ~30 times higher bandwidth than needed for recording an action potential in a neuron.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗