Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

To image, or not to image: class-specific diffractive cameras with all-optical erasure of undesired objects

Abstract Privacy protection is a growing concern in the digital era, with machine vision techniques widely used throughout public and private settings. Existing methods address this growing problem by, e.g., encrypting camera images or obscuring/blurring the imaged information through digital algorithms. Here, we demonstrate a camera design that performs class-specific imaging of target objects with instantaneous all-optical erasure of other classes of objects. This diffractive camera consists of transmissive surfaces structured using deep learning to perform selective imaging of target classes of objects positioned at its input field-of-view. After their fabrication, the thin diffractive layers collectively perform optical mode filtering to accurately form images of the objects that belong to a target data class or group of classes, while instantaneously erasing objects of the other data classes at the output field-of-view. Using the same framework, we also demonstrate the design of class-specific permutation and class-specific linear transformation cameras, where the objects of a target data class are pixel-wise permuted or linearly transformed following an arbitrarily selected transformation matrix for all-optical class-specific encryption, while the other classes of objects are irreversibly erased from the output image. The success of class-specific diffractive cameras was experimentally demonstrated using terahertz (THz) waves and 3D-printed diffractive layers that selectively imaged only one class of the MNIST handwritten digit dataset, all-optically erasing the other handwritten digits. This diffractive camera design can be scaled to different parts of the electromagnetic spectrum, including, e.g., the visible and infrared wavelengths, to provide transformative opportunities for privacy-preserving digital cameras and task-specific data-efficient imaging.

47 OTHER INSTRUMENTATION↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Raccoon density estimation from camera traps for raccoon rabies management

Abstract Density estimation for unmarked animals is particularly challenging, yet density estimates are often necessary for effective wildlife management. Raccoons ( Procyon lotor ) are the primary terrestrial wildlife reservoir for Lyssavirus rabies within the United States. The raccoon rabies variant (RRVV) is actively managed at landscape scales using oral rabies vaccination (ORV) within the eastern United States. To effectively manage RRVV, it is important to know the density of raccoons to appropriately scale the density of ORV baits distributed on the landscape. We compared methods to estimate raccoon densities from camera‐trap data versus more intensive capture‐mark‐recapture (CMR) estimates across 2 land cover types (upland pine and bottomland hardwood) in the southeastern United States during 2019 and 2020. We evaluated the effect of alternative camera configurations and durations of camera trapping on density estimates and used an N‐mixture model to estimate raccoon densities, including covariates on abundance and detection. We further compared different methods of scaling camera‐based counts, with the maximum number of raccoons seen on any given image within a day best explaining density. Camera‐trap density estimates were moderately correlated with CMR estimates ( r = 0.56). However, densities from camera‐trap data were more reliable when classifying category of density as an index used to inform management (83% correct when compared to CMR estimates), although the densities in our study fell into the 2 lowest density classes only. Using more cameras reduced bias and uncertainty around density estimates; however, if ≤6 camera traps were used at a site, a line transect approach proved less biased than a grid design. Camera trapping should be conducted for at least 3 weeks for more accurate estimates of raccoon population density in our study area (<5% bias). We show that camera‐trap data can be used to assign raccoon densities to management‐relevant density index bins, but more studies are needed to ensure reliability across a greater range of environmental conditions and raccoon densities.

Davis, Amy J.↗

Real-Time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors

An electro-optic detector is one of the diagnostic setups used in particle accelerators. It employs an electro-optic crystal to encode the longitudinal beam charge profile in the spectrum of a light pulse. The charge distribution is then reconstructed using data captured by a fast spectrometer. The measurement repetition rate should match or exceed the machine bunching frequency, which is often in the range of several MHz. A high-speed optical line detector (HOLD) is a linear camera designed for easy integration with scientific experiments. The use of modern FPGA circuits helps in the efficient collection and processing of data. The solution is based on Xilinx 7-Series FPGA circuits and implements a custom latency-optimized architecture utilizing the AXI4 family of interfaces. HOLD is one of the fastest line cameras in the world. Thanks to its hardware architecture and a powerful KALYPSO sensor from KIT, it outperforms the fastest comparable commercial devices.

MicroTCA↗

Time-refraction near the critical angle and angular streaking with attosecond resolution [Invited]

We study the time-refraction of optical waves as they propagate through a time-varying slab and find the frequency shift associated with the abrupt change in the refractive index. We discover a geometrical mechanism responsible for an ultrafast blueshift followed by a redshift, occurring while the refractive index is increased monotonically. Furthermore, we find high sensitivity to incident angles near the traditional critical angle and unravel a new critical angle that varies in time. Finally, we introduce an innovative concept of a streak camera design that utilizes ultrafast nonlinearities in time-varying media and offers attosecond resolution capabilities.

Fruhling, Colton (ORCID:0000000282968802)↗

New Design Yields Robust Large-Area Framing Camera

Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow. The NNSS has designed and fielded a new, large-area, gated framing camera called Kraken. The camera design emphasized manufacturability and flexibility by improving imager yield and creating a camera architecture to shorten design cycles. Design strategies and field data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emission spectroscopy with coded apertures for enhanced dimensionality

A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.

42 ENGINEERING↗

The SparkPix-S ASIC for the sparsified readout of 1 MHz frame-rate X-ray cameras at LCLS-II: pixel design and simulation results

Exploiting the “sparse” nature of the information in XPCS (X-ray Photon Correlation Spectroscopy) and XSVS (Speckle Visibility Spectroscopy) experiments, we present the SparkPix-S, a 3-sides buttable Application Specific Integrated Circuit (ASIC) based on a sparsified readout strategy for large-format hybrid detectors. The SparkPix-S architecture, based on the successful ePix family, will be composed as follows: a front-end 2-D matrix of 384×352 square pixels with 50 µm pitch is arranged to match the dimensions of a PIN Si-sensor matrix; charge readout, signal shaping and amplitude discrimination is performed at pixel-level, by means of a low-power (<18 µW) analog processor, which, in case of an event, negotiates access to an analog bus placed every other column; on the chip periphery (balcony), the information on each bus is digitized by an array of successive approximation analog-to-digital converters (SAR-ADCs) running at 10 Msps; on the digital back-end the global logic will generate the output data stream using low-voltage differential signalling (LVDS). A first prototype of the SparkPix-S, with a reduced matrix size of 96×96 pixels, is currently under production on a 130 nm CMOS technology. Simulated performance results show an equivalent noise charge <60 el. r.m.s. at 1 MHz repetition rate, with a maximum input energy of 60 keV and capability to discriminate charge signals with equivalent energy as low as 900 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of the Optical Design of the CMB-S4 Large Aperture Telescopes and Camera Optics

CMB-S4, the next-generation CMB observatory, will deploy hundreds of thousands of detectors to enable mapping the millimeter-wavelength sky with unprecedented speed. The large aperture telescopes for CMB-S4 consist of six-meter diameter crossed Dragone designs and a five-meter diameter three-mirror anastigmat. The two-mirror crossed Dragone design requires astigmatism corrections in the refractive optics to achieve diffraction-limited performance. We present biconic lens corrections for the CMB-S4 crossed Dragone camera optics and compare these designs to the camera optics for the three mirror anastigmat, as the optical designs of the cameras for these telescopes are being prototyped.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing the spatial resolution and gamma discrimination of SiPM-based Anger cameras

SiPM Anger cameras have been designed for use as 2-dimensional thermal neutron detectors for scientific applications such as at single crystal diffraction instruments. These cameras utilize a neutron sensitive scintillator and an array of SiPM photosensors, separated by a light spreading glass. While this optics package is very effective at detecting and positioning neutrons, it is also sensitive to gamma rays, which are a source of unwanted noise. In this work, we underwent a search of scintillator and spreader glass thicknesses to determine the optimal combination for maximizing spatial resolution. Both experimental results and GEANT4 simulations are presented. Further, to address the issue of gamma ray detection, we have also designed and presented a multi-layer scintillator that reduces the amount of scintillation light produced via gamma-ray energy deposition, allowing for easier pulse-height discrimination. A sample of this geometry has been produced that results in a factor of 2 improvement over an equivalent thickness monolithic scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate and Fast Anomaly Detection in Additive Composite-Based Manufacturing using Thermal Cameras

Today, large-scale additive manufacturing with plastics and composite materials requires continuous monitoring by experienced staff to prevent, detect and correct anomalous events affecting the performance of the printed part. We address the complexity of this demanding task by designing a camera-based anomaly detection system utilizing probabilistic principal component analysis (PPCA). This is a machine learning technique is trained with thermal images collected during normal operation of the large-scale printer (Cincinnati BAAM). This technique is advantageous for practical applications as there is no need to artificially introduce anomalous conditions into model training. During deployment, we challenge this model by introducing deliberate variations of the extruder speed. We reduce extrusion speed to a lower level, between 70 and 95% of the nominal value to collected test images. Our results show that images are easily identified as anomalous for extruder speeds at or below 85% of the nominal speed, meaning that an anomalous reduction of the material deposition rate can be detected within seconds of its onset. We show that our results are robust to (a) camera-to-camera variability and (b) print-to-print variability.

Pike, John [ORNL]↗

Novel technology of non-contact real-time radiation damage sensors for high power targets.

This report summarizes the contributions of an intern participating in the Community College Internship (CCI) program at Fermilab, focusing on the development of a novel, non-contact, real-time radiation damage sensor technology. The core objective is to create a reliable sensor capable of measuring radiation-induced degradation on high-power targets without physical contact. The experiment involves using a Class 3B supercontinuum laser directed toward a single material sample placed within a vacuum test chamber. The laser beam reflects off the sample's surface, with changes in reflectivity, indicative of radiation damage, measured by a spectrometer positioned at the chamber’s output port. The intern’s primary responsibilities included designing an interlock system to ensure laser operational safety, developing a camera-based monitoring system using Raspberry Pi devices, and creating structural supports using 3D modeling and printing techniques. Components for the interlock and camera systems were successfully designed and ordered, with preliminary 3D models printed and refined through iterative testing. Challenges encountered in the 3D printing process, such as fragile initial prototypes and difficult support removal, were overcome by adjusting printer settings and incorporating design enhancements like chamfered edges. Future activities, pending component delivery, involve installing and configuring the interlock and camera systems, as well as further improving the structural supports. Overall, the internship significantly enhanced the intern’s technical proficiency in hardware design, software integration, and advanced 3D printing, contributing directly to Fermilab’s operational safety standards and experimental effectiveness in high-energy physics research.

Pumarino Meza, Rafael [Unlisted; Fermilab]↗

New Design Yields Robust Large-Area Framing Camera

Manuscript to be submitted to Review of Scientific Instruments to determine interest in possible publication. Website: https://aip.scitation.org/rsi/authors/manuscript High-speed imaging is a core diagnostic capability for the Nevada National Security Site (NNSS). Data from experiments that measure the behavior of materials under extreme conditions are essential for the stockpile mission. For example, during subcritical experiments, materials that are shocked and compressed under high-explosive drive change behavior rapidly over timescales measured in millionths or even billionths of a second. Characterizing and understanding this behavior requires radiographic and/or optical imaging to track motion on these timescales. Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TEAMER: A Tow Body Optical Camera System

Archive consists of design drawings, assembly instructions, and bill of materials (BOM) for a Igiugig Village Council (IVC)/Ocean Renewable Power company (ORPC) tow body camera system for underwater environmental monitoring using optical cameras. This work was conducted by the University of Washington's Applied Physics Laboratory on behalf of the Igiugig Village Council through TEAMER RFTS 1 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

Continuum radiated power density $(P^{\textrm{C}}_{\textrm{rad}})$ and effective charge $(Z_{\textrm{eff}})$ estimates from multi-energy photon-counting measurements

Multi-energy soft x-ray pinhole cameras have been designed, built, calibrated, and operated at Madison symmetric Torus, Alcator C-Mod, and more recently at Tokamak a configuration variable and Tungsten Environment in Steady-State Tokamak (WEST), to measure plasma emission across multiple energy ranges. Here we describe a new methodology to estimate the local continuum radiated power density and the plasma effective charge (Z eff ) directly from photon-counting measurements of the line-free continuum emission (Bremsstrahlung and Radiative Recombination) in several energy bands between 11 and 18 keV. This capability is particularly valuable for confinement systems using metal plasma-facing components, where x-ray losses from interactions with the sputtered wall can represent a significant fraction of the total radiated power (P rad ). The approach leverages a well-characterized detector responsivity, modeled by a complementary error function, and interprets the differential multi-energy measurements between adjacent energy levels through the probability density function of a Gaussian distribution. The implementation of this diagnostic technique is currently under development on the WEST tokamak, aiming at the goal of providing real-time P rad and Z eff measurements during long-pulse operation (up to 1000 s) in the 2026 campaign.

WEST↗