Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “caliper”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comprehensive Review of Multi-arm Caliper Data for the Big Hill SPR Site

The Big Hill SPR site has a rich data set consisting of multi-arm caliper (MAC) logs collected from the cavern wells. This data set provides insight into the on-going casing deformation at the Big Hill site. This report summarizes the MAC surveys for each well and presents well longevity estimates where possible. Included in the report is an examination of the well twins for each cavern and a discussion on what may or may not be responsible for the different levels of deformation between some of the well twins. The report also takes a systematic view of the MAC data presenting spatial patterns of casing deformation and deformation orientation in an effort to better understand the underlying causes. The conclusions present a hypothesis suggesting the small-scale variations in casing deformation are attributable to similar scale variations in the character of the salt-caprock interface. These variations do not appear directly related to shear zones or faults.

58 GEOSCIENCES↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2024 Update of Comprehensive Review of Multi-arm Caliper Data for the Big Hill SPR Site

The Big Hill SPR site has a rich data set consisting of multi-arm caliper (MAC) logs collected from the cavern wells. This data set provides insight into the on-going casing deformation at the Big Hill site. This report summarizes the MAC surveys for each well and presents well longevity estimates where possible. Included in the report is an examination of the well twins for each cavern and a discussion on what may or may not be responsible for the different levels of deformation between some of the well twins. The report also takes a systematic view of the MAC data presenting spatial patterns of casing deformation and deformation orientation in an effort to better understand the underlying causes. The conclusions present a hypothesis suggesting the small-scale variations in casing deformation are attributable to similar scale variations in the character of the salt-caprock interface. These variations do not appear directly related to shear zones or faults. In addition, the deformation orientation shows no preferred directionality. This 2024 edition of this report represents an update to the original, 2023 edition. The updates primarily focus on the inclusion of MAC log data run since the December 2021 threshold date for the original report, but some new analyses are also included.

58 GEOSCIENCES↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of Dimensional and Microstructural Postirradiation Examination Capabilities on MiniFuel Disk Specimens

This work demonstrates two new MiniFuel postirradiation examination (PIE) capabilities, laser profilometry and serial sectioning, for future use on alpha-U specimens for the upcoming Mini-99 irradiation campaign. Representative U–Mo disk specimens—3 mm in diameter and approximately 0.75 mm in thickness—were subjected to dimensional measurements using standard calipers, as well as a new Keyence CL-3000 series laser profilometry system designed to measure the surface of both sides of the disk simultaneously. The laser profilometry system captured thickness gradients across the specimens as large as 0.2 mm. Additionally, because of the limitations inherent to the use of calipers, caliper measurements consistently overestimated the initial volume of MiniFuel disk specimens compared to the laser profilometry method by up to 5%. However, the results show that optimal data collection and analysis procedures are crucial to avoiding significant artifacts during data collection that can lead to large errors (approximately 10%). Serial sectioning using a combination of ion milling and electron imaging was also demonstrated for the analysis of micron-sized control volumes. Nanometer- to micron-scale porosity was resolved on a representative U–Mo specimen before irradiation, even when the surface of the specimen appeared free of porosity. Future efforts to relate microstructural features (porosity, fission product distributions, and so on) to macroscale effects (dimensional changes, thermal conductivity degradation) require accurate characterization methods such as those demonstrated in this work. These advanced PIE capabilities will be applied to optimized alpha-U specimens for the upcoming Mini-99 neutron irradiation campaign.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HEU Pancake (Jemima) Plate Preliminary Characterization Report

The HEU pancake (Jemima) plates have been used in multiple International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations, including: HEU-MET-FAST-072, HEU-MET-FAST-073, HEU MET-FAST-102, HEU-MET-INTER-006, HEU-MET-INTER-011, HEU-MET-MIXED-021, and IEU MET-FAST-025. This report only focuses on the physical dimension characterization, since concerns have been identified about reliable diameter and height measurements. Historically, height measurements with calipers and mass measurements have been performed for every plate. However, the combination of previous measurements (mass and caliper height measurements) with the drawing dimensions for the diameters led to unrealistic densities (>19 g/cm 3 ) or large ranges of densities for parts that were manufactured at the same time (17 g/cm 3 to >19 g/cm 3 ). Due to the oxidation of the plates, questions about the flatness of each plate and what gaps are introduced into the system have been discussed, since gaps tend to be one of the largest sources of uncertainty in stacked benchmark experiments. The purpose of this report is to characterize a subset of this commonly used fuel. A uniform method for how to define the HEU pancake plates for ICSBEP evaluations will also be proposed with a discussion on what measurements should be performed on the remaining HEU pancake plates in the NCERC inventory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Parameters for the Particle Size Distribution of TATB

Laser light scattering (LLS), manual counting of scanning electron microscopy (SEM) images, and reduction of SEM images using ImageJ (open source program) to determine Feret (caliper) diameters were applied to determine particle size distribution (PSD) of four preparations of 1,3,5‐triamino‐2,4,6‐trinitrobenzene (TATB) and yttria‐stabilized zirconia (YSZ), an SEM certified standard. Mie theory was used to reduce the LLS data. The spherical nature of the YSZ made it a good candidate for LLS. Variations in n , the refractive index, and iκ, the imaginary component, produced very little change in the PSD. However, changing the carrier liquid from H 2 O to a 40% aqueous sucrose solution, thereby changing the carrier refractive index, n 0 , substantially affected the PSD. The Mie complex refractive indices for the YSZ were n = 2.200, iκ = 0.100, with a 40% aqueous sucrose solution, n 0 = 1.400. The triclinic crystal structure of TATB made refractive index determinations more difficult, so a study was conducted varying Mie parameters and comparing them to the same data reduced using the Fraunhofer theory. Changing the n and κ parameters produced PSD with a small concentration of particles less than 1 µm in size or none in this range. SEM images, Feret data, manual counting, and Fraunhofer data reduction indicate particles less than 1 µm are probably < 5% in concentration. The final selection of Mie parameters for TATB was n = 2.283, iκ = 0.1, and suspension medium, n 0 = 1.330. Finally, computations, using density functional theory produced similar parameters.

Feret diameter↗

Parallel sorting algorithm classification: is manual instrumentation necessary?

Understanding parallel algorithms is crucial for accelerating scientific simulations on complex, distributed memory, high-performance computers. Modern algorithm classification approaches learn semantics directly from source code to differentiate between algorithms, however, accessing source code is not always possible. We can learn about parallel algorithms from observing their performance, as programs running the same algorithms and using the same hardware should exhibit similar performance characteristics. We present an approach to learn algorithm classes from parallel performance data directly in order to classify algorithms without access to the source code. We extend previous work to enable classifying parallel sorting algorithms using automatic instrumentation instead of requiring manual region annotations in the source code. In this work, we design and demonstrate a study for classification of parallel sorting algorithms using parallel performance data collected from automatic instrumentation, and evaluate the performance of our new methodology on classification. We leverage Caliper to collect the performance data, Thicket for our exploratory data analysis (EDA), and PyTorch and Scikit-learn to evaluate the effectiveness of random forests, support vector machines (SVMs), decision trees, neural networks, and logistic regressions on parallel performance data. Additionally, we study noise in parallel performance data, whether the removal of noise and pre-processing of the data is necessary to accurately classify parallel sorting algorithms, and determine the effectiveness of features created from performance data. In conclusion, we demonstrate classification accuracy for these five different models of up to 97.7% across four different parallel algorithm classes.

Algorithm Classification↗

Characterization of the mud displacement in an enlarged wellbore: An integrated rock-fluid model

Cement-mud displacement plays a crucial role in the sealability of cement sheaths. Irregular geometric features of a wellbore due to washout can have a negative impact on mud and cement mobilization. An unstable interface between two fluids always leads to mud channeling, interfluid mixing, and cement contamination, degrading the cement quality. Many factors, such as mechanical and rheological properties of fluids, annulus geometry, flow pattern, and flow rate, significantly influence the displacement efficiency. This study investigates the characterization of the mud displacement in an irregular horizontal well using a 3D computational fluid dynamics (CFD) model. Mud is displaced in an enlarged wellbore by geopolymer and neat class G cement. The wellbore geometry is developed based on the caliper log data from an unconventional shale well in the Tuscaloosa Marine Shale (TMS) lithology. The effects of pump rate, density difference, and mud contamination are evaluated by numerical simulations. The results present those residual muds mainly exist in the upper annulus of the enlarged section. Geopolymer has a better sealing performance and can resist more water-based mud (WBM) contaminations than neat class G cement. The scenario with a low mud-cement density difference and high cement injection rate results in a high cement volume fraction, mitigating the gas migration.

58 GEOSCIENCES↗

Corroborating Channel Gap Probe Measurements with an Optical Profiler

As nuclear fuel plates get irradiated, the fuel plate thickness changes. How the fuel plate changes with irradiation is a significant parameter that is important to predict fuel performance in new fuel systems. The channel gap probe is used to indirectly infer changes in fuel plate thicknesses by measuring the gaps between the fuel plates contained within capsules after each irradiation cycle. Independent measures should be used to corroborate salient measurements such as changes in fuel thickness which help ascertain fuel performance. The use of traditional metrological tools to validate channel gap probe measurements are not practical due to the capsule geometry. The accuracy of the channel gap probe inserted within a capsule has not been verified. Since there is no “gold” standard measurement to verify CGP measurements, an optical profilometer has been used to corroborate the CGP measurements. The optical profilometer has been able to corroborate the capsules channel gaps to within 0.04 mm for both ends of the capsule. The optical profiler is also able to measure plate thickness that matched micrometer measurements to within 0.025 mm. In conclusion, the profilometer corroborated the CGP measurements but a discrepancy was found at one end of the capsule for the Inside Capsule Width from the profilometer when compared to a caliper measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Treescape

Visualizing performance data from caliper

Aschwanden, PascalD [Lawrence Livermore National L↗

UMap: An application-oriented user level memory mapping library

Exploiting the prominent role of complex memories in exascale node architecture, the UMap page fault handler offers new capabilities to access large memory-mapped data sets directly. UMap provides flexible configuration options to customize page handling to each application, including analysis of massive observational and simulation data sets. The high-performance design features I/O decoupling, dynamic load balancing, and application-level controls. Page faults triggered by application threads and processes accessing data mapped to a UMapp’ed region are handled via the Linux userfaultfd protocol, an asynchronous message-oriented kernel-user communication mechanism that avoids the context switch penalty of traditional signal fault handlers. UMap is fully open source. In this paper, we give an overview of the UMap library architecture, its extensible plugin architecture, and the use/performance of UMap in emerging heterogeneous memory hierarchies such as near-node Non-volatile Memory (NVM) and network attached memories. We highlight new capabilities in two pagefault management plugins, the NetworkStore and SparseStore. We demonstrate the integration between UMap and multiple ECP products including Caliper, Metall, ZFP, Mochi, and Ripples.

97 MATHEMATICS AND COMPUTING↗

Integrating Machine Learning into a Methodology for Early Detection of Wellbore Failure [Slides]

Approximately 93% of US total energy supply is dependent on wellbores in some form. The industry will drill more wells in next ten years than in the last 100 years (King, 2014). Global well population is around 1.8 million of which approximately 35% has some signs of leakage (i.e. sustained casing pressure). Around 5% of offshore oil and gas wells “fail” early, more with age and most with maturity. 8.9% of “shale gas” wells in the Marcellus play have experienced failure (120 out of 1,346 wells drilled in 2012) (Ingraffea et al., 2014). Current methods for identifying wells that are at highest priority for increased monitoring and/or at highest risk for failure consists of “hand” analysis of multi-arm caliper (MAC) well logging data and geomechanical models. Machine learning (ML) methods are of interest to explore feasibility for increasing analysis efficiency and/or enhanced detection of precursors to failure (e.g. deformations). MAC datasets used to train ML algorithms and preliminary tests were run for “predicting” casing collar locations and performed above 90% in classification and identifying of casing collar locations.

54 ENVIRONMENTAL SCIENCES↗

Integrating Machine Learning into a Methodology for Early Detection of Wellbore Failure [Slides]

Approximately 93% of US total energy supply is dependent on wellbores in some form. The industry will drill more wells in next ten years than in the last 100 years (King, 2014). Global well population is around 1.8 million of which approximately 35% has some signs of leakage (i.e. sustained casing pressure). Around 5% of offshore oil and gas wells “fail” early, more with age and most with maturity. 8.9% of “shale gas” wells in the Marcellus play have experienced failure (120 out of 1,346 wells drilled in 2012) (Ingraffea et al., 2014). Current methods for identifying wells that are at highest priority for increased monitoring and/or at highest risk for failure consists of “hand” analysis of multi-arm caliper (MAC) well logging data and geomechanical models. Machine learning (ML) methods are of interest to explore feasibility for increasing analysis efficiency and/or enhanced detection of precursors to failure (e.g. deformations). MAC datasets used to train ML algorithms and preliminary tests were run for “predicting” casing collar locations and performed above 90% in classification and identifying of casing collar locations.

54 ENVIRONMENTAL SCIENCES↗