Statistical Calibration of the HIFiRE Flight 2 Combustion Model
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Progress and the future plans for the following objectives are discussed: (1) Assess the accuracy at which the SIR-C/X-SAR standard data products can be calibrated through the use of ground calibrators to estimate the end-to-end system polarization calibration constants (or distortion parameters) and incorporate the constants into the data processing; (2) Study the cross-calibration between three multipolarization systems: SIR-C, the National Aeronautics and Space Administration/Jet Propulsion Laboratory (NASA/JPL) DC-8 SAR, and the University of Michigan ground-based polarimetric scatterometer; (3) Evaluate the calibration "stability" of SIR-C/X-SAR (measured by variations in the calibration constants) over the range swath width and over a specified distance in azimuth. Variations over a 12-hour period (between ascending and descending passes) will also be studied; and (4) Develop a cost-effective calibration plan including development of inexpensive polarimetric active calibrators.
Calibrated measurements of electron velocity distribution functions (VDFs) are necessary to characterize fluid and kinetic processes in weakly collisional and nearly collisionless plasmas such as the solar wind. Therefore, we analyzed 3,996,051 electron VDFs observed by the Wind 3DP thermal electron detector near 1 astronomical unit (au) between January 1, 2005 and November 25, 2017. The data were calibrated for each electron VDF to produce accurate velocity moments in the solar wind. This is the first full solar cycle coverage electron velocity moment dataset in the near-Earth solar wind. Herein (Paper I) we discuss the calibration process/algorithms and the velocity moment constraints, uncertainties, and resulting public dataset. In the second paper (Paper II), we statistically analyze the electron velocity moment dataset.
Explore the source record for details and available documents.
The Advanced Technology Microwave Sounder (ATMS) SN301 is an instrument onboard the QuickSounder Satellite System, QuickSounder mission (renamed QS). Throughout this document the mission may be referred to as QuickSounder or QS. The purpose of this document is to provide information needed to interpret and process QS ATMS science data. The contents of the data book incorporate results from pre-launch subsystem-level and instrument-level testing as well as post-launch testing performed during instrument commissioning. Major milestones include instrument thermal vacuum (TVAC) testing in May 2024 and observatory TVAC testing in 2026. QS launch will be no earlier than Feb. 15, 2027.
Calibration measurements for the cooled (253 K) photomultiplier tube (PMT) detector, used on the receiver channel of the transmit/receive (T/R) switch for GOPEX, were conducted in the laboratory. A pulsed frequency-doubled neodymium:yttrium-aluminum-garnet (Nd:YAG) laser was used to direct 532-mn light on the PMT. By monitoring the energy per pulse of the light incident on the PMT, the minimum number of photons detected could be determined. These results agreed with the photon flux back-calculated from the PMT output waveform. Approximately 700 incident photons arriving during a temporal pulse width of approximately 65 nsec were detected with a signal-to-noise ratio (SNR) of approximately 1. Other receiver channel characteristics, such as PMT dark currents, optical transmission, and interference filter sensitivity to angle of light incidence, were also measured.
ESA’s Hera space mission is on its way to the mission target, the binary asteroid (65803) Didymos. HyperScout-H, one of the instruments onboard Hera, is a hyperspectral imager operating in the visible and near-infrared regions between 0.65 and 0.95 μm. HyperScout-H will enable a detailed assessment of the composition of both objects, Didymos and its satellite Dimorphos, the characterization of space weathering effects, and the possible presence of exogenous material on their surfaces. To monitor instrument functionality, calibration exposures are acquired regularly. This article describes the in-flight calibrations carried out for HyperScout-H during the commissioning and cruise phases. Bias and dark exposures, as well as stellar field observations, were acquired several times after launch. We update the calibration data and monitor instrument performance in the space environment. In addition, images of Earth and Moon were acquired from distances of 1.5 × 10 6 to 2.0 × 10 6 km, and Mars and its satellite were imaged during the flyby. In five images, the surface of Mars fills the entire field of view, enabling cross-validation of HyperScout-H results with those reported by other Mars missions. We characterize the detector under in-flight operational conditions. The calibration data indicate that the bias pattern is stable, the dark current remains negligible for short exposures, and the detector response is highly linear. We quantify the field-of-view alignment and geometric distortion, and evaluate the point spread function based on the stellar field observations. Stellar observations and Mars swing-by data provide updated radiometric calibration constants, suggesting that in-flight conditions have slightly modified the detector’s spectral response. In-flight calibrations are essential to ensure data quality and reliability.
The third Advanced Technology Microwave Sounder (ATMS) is an instrument onboard the Joint Polar Satellite System (JPSS), JPSS-2 (renamed NOAA-21 in orbit) mission. This report is to introduce the JPSS-2 Government Calibration Data Book (J2 GCDB) for ATMS, SN 304. This J2 GCDB document contains key information generated during the calibration testing campaign that is driving parameters for radiometric performance. This document also contains supporting data that augments the calibration results. The values in this document are utilized by ATMS’s calibration packet which is, in turn, an integral component in the interpretation of science data. The calibration data in this report was collected from tests such as shelf-level testing, antenna testing, instrument thermal vacuum (TVAC) testing; satellite TVAC testing; and JPSS-2 post-launch tests. JPSS-2 was launched on November 10, 2022. In the subsequent years, the Government will release an ATMS GCDB for each JPSS mission. We expect that all public users can download these ATMS GCDBs from the NOAA operational Integrated Calibration and Validation System (ICVS) website, see more discussions below. The goal of this GCDB is to demonstrate how to characterize ATMS measurements using JPSS-2 ATMS on-orbit operational data and to provide relevant explanations. This document serves as a primary public domain reference for calibrating operational ATMS Raw Data Records (RDR) science data, as used in the current operational Interface Data Processing Segment (IDPS) system. This same RDR science data is distributed through direct broadcast (DB) to DB users for use in their ground processing systems. This J2 GCDB provides the results of the ATMS system radiometric calibration, the antenna flat reflector emissivity [1], the antenna pattern measurements, the antenna pattern corrected brightness temperature [2], the brightness temperature of the lunar disk [3], Lunar Intrusion (LI) correction algorithm [4], receiver spectral parameters, and mechanical alignment on-orbit pointing results, and the striping effect appeared significantly in S-NPP on-orbit radiance data when the data are compared to the Radiative Transfer Model (RTM) simulation in numerical weather prediction (NWP) system [5]. It also provides the parameters required for conversion of telemetry counts to engineering units, for radiometric calibration, and for antenna beam geo-location. Moreover, it provides JPSS-2 ATMS Spectral Response Functions data, some additional information related to ATMS on-orbit performance, on-orbit lunar intrusion correction parameters and Earth contamination bias, and on how to derive ATMS RDR, antenna Temperature Data Records (TDR), and Sensor Data Records (SDR). Furthermore, an introduction of NOAA operational Integrated Calibration and Validation System (ICVS) website and services is added in this J2 GCDB. This ICVS hosts a long-term monitoring system which allows to visualization and comparison of data from JPSS missions, NOAA legacy Polar Operational Environmental Satellites (POES), and Geostationary Operational Environmental Satellites (GOES). From NOAA Comprehensive Large Array-data Stewardship System (CLASS), the public users can download all JPSS ATMS data products for all JPSS missions.
Two components of the error of a troposphere calibration measurement were quantified by theoretical calculations. The first component is a beam mismatch error, which occurs when the calibration instrument senses a conical volume different from the cylindrical volume sampled by a Deep Space Network (DSN) antenna. The second component is a beam offset error, which occurs if the calibration instrument is not mounted on the axis of the DSN antenna. These two error sources were calculated for both delay (e.g., VLBI) and delay rate (e.g., Doppler) measurements. The beam mismatch error for both delay and delay rate drops rapidly as the beamwidth of the troposphere calibration instrument (e.g., a water vapor radiometer or an infrared Fourier transform spectrometer) is reduced. At a 10-deg elevation angle, the instantaneous beam mismatch error is 1.0 mm for a 6-deg beamwidth and 0.09 mm for a 0.5-deg beam (these are the full angular widths of a circular beam with uniform gain out to a sharp cutoff). Time averaging for 60-100 sec will reduce these errors by factors of 1.2-2.2. At a 20-deg elevation angle, the lower limit for current Doppler observations, the beam-mismatch delay rate error is an Allan standard deviation over 100 sec of 1.1 x 10 -14 with a 4-deg beam and 1.3 x 10 -15 for a 0.5-deg beam. A 50-m beam offset would result in a fairly modest (compared to other expected error sources) delay error (less than or equal to 0.3 mm for 60-sec integrations at any elevation angle is greater than or equal to 6 deg). However, the same offset would cause a large error in delay rate measurements (e.g., an Allan standard deviation of 1.2 x 10 -14 over 100 sec at a 20-deg elevation angle), which would dominate over other known error sources if the beamwidth is 2 deg or smaller. An on-axis location is essential for accurate troposphere calibration of delay rate measurements. A half-power beamwidth (for a beam with a tapered gain profile) of 1.2 deg or smaller is desired for calibration of all types of radio metrics. A water-vapor radiometer calibration beam of this size with very low sidelobes would require a clear aperture antenna with a diameter of at least 1.5 m if the primary water vapor sensing channel were in the 20-22 GHz range.
The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument onboard the NOAA-21 (N21) satellite has been successfully operating for over three years collecting valuable scientific measurements. A large suite of weather forecasting models and scientific research applications are supported with the VIIRS measurements from N21 combined with those acquired from the VIIRS instrument onboard the S-NPP and NOAA-20 spacecraft. Among the 22 VIIRS spectral bands, there are seven thermal emissive bands (TEB) covering the 3.7 to 12.2 µm spectral range at two different spatial resolutions. The VIIRS TEB detectors are calibrated onboard using a blackbody at a controlled temperature and a space view for background signal measurement. In this paper, we discuss the on-orbit performance of the N21 VIIRS TEB using various parameters such as the detector gain, noise, and offset. This on-orbit assessment provides critical insights into instrument behavior and calibration performance that will inform pre-launch testing and post-launch validation strategies for the upcoming JPSS-4 VIIRS mission scheduled for launch in 2027. The methodologies and lessons learned from characterizing the N21 TEB performance will enable more efficient and comprehensive radiometric assessment of the next VIIRS instrument. Specific focus is placed on identifying performance trends and anomaly signatures observed during the N21 commissioning phase that can enhance the JPSS4 instrument checkout procedures and accelerate the transition to routine on-orbit operations. The established performance baselines and uncertainty estimates will serve as an acceptance criterion for the JPSS-4 commissioning activities, ensuring mission readiness and data continuity for operational users.
Hyperspectral Earth-reflected solar measurements contain rich, detailed information about clouds, aerosols, and the atmosphere. This information compounds when paired with high, SI-traceable radiometric accuracy. Unlike spectral resolution, which can be resampled to coarser spectral resolutions, radiometric accuracy cannot be recovered once a measurement is made, making the choice to invest in this capability now a decision with lasting consequences for the climate record. CLARREO Pathfinder is demonstrating that this combination of hyperspectral sampling and benchmark-quality accuracy is achievable today, but no follow-on mission is currently planned within NASA's Earth Science Division portfolio, and the recent cancellation of the European Space Agency TRUTHS mission has heightened the urgency of sustaining this capability. We recommend prioritizing investment in a follow-on to CLARREO Pathfinder, along with dedicated support for the science community to fully exploit these measurements. This capability would reduce long-standing uncertainties in cloud feedback, aerosol forcing, and global energy imbalance, while providing a degradation-resistant, gap-resilient calibration foundation for the broader Earth observing system. Building on flight-proven technology and an engaged science community, this is a near-term, fiscally realistic opportunity to secure a foundational Earth observation capability for the coming decade.
Corrective actuator forces are applied to the DSS 13 antenna structure to improve its accuracy. These forces are calibrated according to the antenna elevation requirements. The calibration is derived from accurate field measurements and is not subject to the errors that result from computer modeling. A successful demonstration provided significant antenna surface improvement. An improvement of 0.6 to 1 dB is predicted.
The uniformity performance characteristic in remote sensing data products is a metric that helps evaluate how an image accurately represents radiometric responses to geophysical variability at the Earth’s surface or within the atmosphere. These uniformity attributes are used in Earth remote sensing science applications such as investigating water quality, land-cover/land-use classifications, and crop health assessments. To ensure these applications perform effectively, it is crucial to maintain and regularly assess the uniformity of calibrated remote sensing data products. In the Landsat missions, data from the onboard radiometric reference Solar diffuser device are used as the standard approach to derive the calibration parameters, ensuring the maintenance of both absolute radiance and radiometric uniformity through quarterly updates. This publication presents an alternative approach that leverages Earth scene data to assess the on-orbit uniformity performance of the Landsat 9 (L9) mission. The analysis characterizes uniformity at a specific set of spatial positions (the focal-plane boundary zones) that are intrinsic to the Operational Land Imager (OLI) focal plane design. By employing these Earth data statistics, the article further explores the temporal trends in the radiometric uniformity results. The results shown in this article demonstrate that for pushbroom imaging design systems with staggered sensor chip focal plane architectures, the co-registered pixels, i.e., overlapping measurements of the same ground target viewed by different detectors, offer a self-contained mechanism for assessing product uniformity. Remarkably, this alternative approach achieves a level of radiometric quality comparable to that delivered by a stable, well-characterized onboard Solar diffuser calibration device. The findings demonstrate the potential and capability of such Earth scene statistics in maintaining radiometric uniformity in calibrated data products to better than 1% (1-sigma) throughout the mission’s operational lifetime.
QuickSounder (QS) is the pathfinder space mission for the next generation of NOAA LEO environmental satellites in the NEON program, follow-on to the JPSS program. It is a collaborative initiative between NASA and NOAA to verify rapid and cost-effective delivery of small Earth observation satellites. QuickSounder is focusing on mission elements other than science performance. In this context, an existing sensor, the refurbished ATMS EDU (Advanced Technology Microwave Sounder, Engineering Development Unit) was chosen as the QuickSounder payload. This poster discusses the performances of QuickSounder ATMS during thermal vacuum (TVAC) calibration to ensure that QS ATMS is characterized and calibrated in the same manner as JPSS ATMS units, even though science performance attributes are not the priority of this mission.
The laser transmission and monitoring system for the Galileo Optical Experiment (GOPEX) at the Table Mountain Facility (TMF) in Wrightwood, California is described. The transmission system configuration and the data measurement techniques are described. The calibration procedure and the data analysis algorithm are also discussed. The mean and standard deviation of the laser energy transmitted each day of GOPEX show that the laser transmission system performed well and within the limit established in conjunction with the Galileo Project for experiment concurrence.
In anticipation of large-domain crop model applications where precise local configuration and calibration is not possible, we describe benefits and potential drawbacks of employing a crop pest module to achieve leaf area index (LAI) assimilation into a high performing CERES-Maize crop model configuration at a field experiment site in Perry, Iowa. Simulation experiments explore the use of MODIS satellite-derived LAI to constrain and adjust LAI to counter imprecise cultivar and soil configurations often occurring in the absence of high-quality local information. Simulations using single-day, window, and continuous LAI replacement across 5 cultivars and 2 soil calibration approaches for nine corn rotation years from 2004 to 2020 led to different yield outcomes and reverberations throughout the field environment. Evaluating variance and mean bias, results indicate minimal interventions in early vegetative and grain-filling stages were more beneficial than use of continuous LAI adjustments, as they minimized disruptions to the internal resource balances governing plant stresses and grain production. LAI adjustment was particularly helpful in constraining growth related to uncertain thermal unit requirements and leaf tip appearance rates (P1 and PHINT cultivar parameters, respectively). Findings underscore the need to assimilate additional state variables to ensure internal biophysical coherence. This approach shows promise for applications spanning wider domains with prediction time pressure where detailed configuration, more complex assimilation methods, or recalibration of crop model parameters may not be practical.
A process for determining the waste heat generated in a 50-ampere-hour, nickel cadmium battery as a function of the discharge rate is described and results are discussed. The technique involved is essentially calibration of the battery as a heat transfer rate calorimeter. The tests are run at three different levels of battery activity, one at 40-watts of waste heat generated, one at 60, and one at 100. Battery inefficiency ranges from 14 to 18 percent at discharge rates of 284 to 588 watts, respectively and top-of-cell temperatures of 20 C.
The Stimulus Of Ray Cones (SORC) is an optical stimulus system developed to verify, characterize, and calibrate the Roman Space Telescope’s (RST) Wide Field Instrument (WFI) under simulated operational conditions. SORC provides several critical test modes, the primary being point-source mode, which projects an image anywhere on the Focal Plane Assembly (FPA) detectors. This mode provides precise position knowledge of the FPA within WFI. Additional modes enable capturing WFI pupil alignment, evaluation of WFI’s selectable optical elements, and verification of focal plane fiber operation for higher-level system testing. The light source system incorporates a suite of narrowband and broadband fiber fed sources spanning the visible to near-infrared range, with options for pulsed or continuous wave illumination. SORC was designed and built at NASA’s Goddard Spaceflight Center (GSFC). Initial system-level testing occurred under ambient conditions in GSFC’s Spacecraft Systems Development and Integration Facility (SSDIF), followed by vacuum testing at operational temperatures (SORC at 214-222 K) in the Space Environment Simulator (SES). The system was then shipped to BAE Systems in Boulder, CO for post-shipment ambient and cryogenic testing before integration with WFI for two thermal vacuum test campaigns at cryogenic temperatures. This presentation will focus on design, development, and performance of SORC. Details of WFI verification and calibration using SORC, along with test results, have been published previously and will be referenced only as needed to describe SORC. The SORC ground test capability is critical to ensuring WFI meets stringent optical performance requirements, directly supporting the mission’s science objectives.