Engineering PapersSearch

SEARCH · Engineering Papers

Results for “cable rating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

The load-carrying and thermal characteristics of flat conductor cable

The load-carrying and thermal characteristics of flat conductor cable and round wire cables have been investigated with all conductors in each cable under varying loads in air and vacuum environments. The test procedure is described and results are presented in graphic form. Derating factors for both round wire and flat conductor cable are established for operation in a vacuum environment. Rating factors are established for flat conductor cable for use with round wire loading tables. The results of these tests show that single layer flat conductor size, or that the voltage drop across flat conductor cable will be lower than that of round cable under the same load.

Adams, G. D.

Cut-through tester accurately measures insulation failure rates

Cut-through tester electronically measures the rate of failure of various wire and cable insulating materials both as to time and the amount of applied pressure. The force /weight/ acting on the penetrator can be applied through a near infinite range.

Baker, E. U.

Dynamic Response of Control Servo System Installed in NAES-Equipped SB2C-5 Airplane (BuAer No. 83135)

Dynamic--response measurements for various conditions of displacement and rate signal input, sensitivity setting, and simulated hinge moment were made of the three control-surface servo systems of an NAES-equipped remote-controlled airplane while on the ground. The basic components of the servo systems are those of the General Electric Company type G-1 autopilot using electrical signal. sources, solenoid-operated valves, and hydraulic pistons. The test procedures and difficulties are discussed, Both frequency and transient-response data, are presented and comparisons are made. The constants describing the servo system, the undamped natural frequency, and the damping ratio, are determined by several methods. The response of the system with the addition of airframe rate signal is calculated. The transfer function of the elevator surface, linkage, and cable system is obtained. The agreement between various methods of measurement and calculation is considered very good. The data are complete enough and in such form that they may be used directly with the frequency-response data of an airplane to predict the stability of the autopilot-airplane combination.

Smaus, Louis H.

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains Task 3: Lifetime and Reliability of Electrical Insulators

This research project was a collaborative investigation between researchers at the RTX Technology Research Center (RTRC) and the University of Texas at Austin and made a significant contribution to enabling electric aircraft. The transport of electric power between the points of generation and use requires power cables. These cables must be smaller, lighter and provide a more predictable life than power cables used in stationary applications. Consequently, this investigation provided heretofore unavailable information supporting the safety and reliability of smaller lighter power cables for electrified aircraft. In addition, the research identified key additional engineering data needed to support quantitative reliability assessments. Important advances included: • Demonstrated that at least one manufacturer can make a novel, smaller, lighter power cable that is free from serious defects. • Developed and published an appropriate analytical construct to describe the life of this novel cable. This is a necessary step for use in aviation where the understanding of remaining life is critical. • Demonstrated thermal-mechanical aging that suggested 1000+ flights before the thermal-mechanical processes produced defects large enough that the defect growth was accelerated electrically. • Showed that electrical aging took place at two rates. The first possibly lasting weeks to months and the second possibly days to weeks. If robust, this provides a good diagnostic for cable replacement. • Demonstrated that the traditional electrical testing of cable materials using manufactured voids can be misleading due to the size of the voids. Emerging laser drilling technology permitted demonstration that the physics of failure in realistically small voids is different from that in the unrealistically large voids used in earlier research, which is very important for high-quality, high-performance, small aircraft cables. Although this project represents a significant contribution to the specifics of cable aging in the aircraft environment, important additional research remains to be completed, including: • Non-uniform thermal cycling by applying the heat from the center conductor to maximize thermal stress next to the core area where the electric gradient is the strongest. This builds on the uniform thermal cycling that has been completed. • The augmentation of the thermal-mechanical failure rate by electrical processes. Better understanding of these time constants strongly affects the ability to predict life. • Termination design: Terminations provide not only electrical reflection potential, but a location for a series arc fault and an area where ozone can diffuse into the center conductor and negatively affect cable insulation. • The abrasion and ozone resistance of the cable jacket. • Pressure cycling as an accelerant of thermal, mechanical, and/or electrical aging. • Possible methods for online PD detection and offline PD localization

model

High bit rate mass data storage device

The HDDR-II mass data storage system consists of a Leach MTR 7114 recorder reproducer, a wire wrapped, integrated circuit flat plane and necessary power supplies for the flat plane. These units, with interconnecting cables and control panel are enclosed in a common housing mounted on casters. The electronics used in the HDDR-II double density decoding and encoding techniques are described.

Source record

Measured losses in superconductor magnets for 60-Hertz ac operation.

Results of an experimental study of electrical losses in superconductor magnets. Preliminary 60-Hz ac loss data are presented for coils constructed of Nb3Sn ribbon, Nb-Ti cable, and multifilament Nb-Ti. Losses have been measured for different size coils up to approximately 20 cm in diameter. Of the conductor types tested, Nb3Sn ribbon has the lowest losses for ac operation. In Nb3Sn-ribbon coils of different sizes, the loss per unit length of conductor is shown to decrease with a decrease in the rate of change of current and to increase, in general, with increase in coil size. An important aspect of the study is the high degree of repeatability of the data.

Hamlet, I. L.

Flight Characteristics of a 1/4-Scale Model of the XFV-1 Airplane (TED No. NACA DE-378)

A l/4-scale dynamically similar model of the XFV-1 airplane has been flown in the Ames 40- by 80-foot wind tunnel, using the trailing flight-cable technique. This investigation was devoted to establishing the flight characteristics of the model in forward flight from hovering to wing stall, and in yawed flight (wing span alined with the relative wind) from hovering to the maximum speed at which controlled flight could be maintained. Landings, take-offs, and hovering characteristics in flights close to the ground were also investigated.. Since the remote control system for the model was rather complicated and provided artificial damping about the pitch, roll, and yaw axes, sufficient data from the control-system calibration tests are included in this report to specify the performance of the control system in relation to both the model flight tests and the design of an automatic control system for the full-scale airplane. The model in hovering flight appeared to be neutrally stable. The response of the model to the controls was very rapid, and it was always necessary to provide some amount of artificial damping to maintain control. The model could be landed with little difficulty by hovering approximately a foot above the floor and then cutting the power. Take-offs were more difficult to perform, primarily because the rate of change in power to the model motors was limited by the characteristics of the available power source. The model was,capable of controlled yawed flight at translational velocities up to and including 20 feet per second. The effectiveness of the controls decreased with increasing speed, however, and at 25 fps control in pitch, and probably roll, was lost completely. The model was flown in controlled forward flight from hovering up to 70 fps. During these flights the model appeared to be more difficult to control in yaw than it was in pitch or roll. The flights of the model were recorded by motion picture cameras. These motion pictures are available on loan from NACA Headquarters as a film supplement to this report.

Kelly, Mark W.