Engineering PapersSearch

SEARCH · Engineering Papers

Results for “cable rating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Neural Network‐Based Methods for Ocean Surface Wave Measurement Using Submarine Distributed Acoustic Sensing (DAS)

Two new data-driven models for estimating ocean surface waves from distributed acoustic sensing (DAS) submarine cable strain rate are developed using supervised machine learning on a 10-day data set collected offshore of Oliktok Point, Alaska. The new models were trained on target data from seafloor pressure moorings at three sites spaced evenly along 27.1 km of cable and were benchmarked against an empirical transfer function method previously used to estimate waves from DAS. A model which uses convolutional neural networks to transform 2-km frequency-wavenumber strain spectra to seafloor pressure spectra outperforms the benchmark in wave height prediction (RMSE of 0.15 vs. 0.41 m) and period prediction (0.29 vs. 0.37 s) when evaluated on a held-out test data set. When applied to a DAS data set collected on the same cable 2 years prior, the CNN-based model maintained similar significant wave height performance (RMSE = 0.23 m) relative to available satellite altimetry data. A two-hidden-layer, fully connected neural network which transforms 1-D strain spectra to seafloor pressure spectra also outperforms the benchmark in wave height prediction (RMSE of 0.19 vs. 0.41 m), but does not generalize as well to the prior data. Regression-based machine learning is useful for estimating waves from DAS data when the pressure-strain relationship varies temporally and spatially across different wave conditions. Models can be applied to DAS data to measure waves with higher spatial resolution and longer temporal coverage than traditional methods, which often measure waves only at a single point.

Davis, Jacob R. [Univ. of Washington, Seattle, WA

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION

Addendum to SAND2023-09604 Xyce lumped-element transmission line model verification to support Empire-Cable cable SGEMP analyses

This report supplements the Verification of Empire-Cable SAND report by expanding on the use of Xyce to simulate the coupling to a transmission line cable model. While Empire-Cable solves its governing equations on a high-order, finite-element mesh with an an implicit-in-time formulation, Xyce must use a first order graph for the circuit and explicit-in-time approach to be compatible with non-linear electrical device models. Thus, given the different solution methodologies in Xyce as compared to Empire-Cable, the convergence rates are expected to be different but the overall quality of the solution should be the same. The original four canonical problems studied in the Empire-Cable verification report are replicated here running in Xyce using transmission line modeling parameters from the verification report. Overall, agreement between the codes is excellent with Xyce’s convergence rates being limited mostly to first order due to the circuit network approximation of a transmission line being a first order approximation.

42 ENGINEERING

Proposal for superconducting quantum networks using multioctave transduction to lower frequencies

We propose networking superconducting quantum circuits by transducing their excitations (typically 4–8 GHz) to 200–500 MHz photons for transmission via superconducting cryogenic coaxial cables. This frequency down-conversion reduces transmission losses and, counterintuitively, reduces noise. We introduce a multioctave asymmetrically threaded superconducting quantum interference device circuit capable of the required efficient, high-rate transduction. For a 100-meter cable with 𝑄 𝑖 = 10 5 at 10 mK, we theoretically show that our approach achieves single-photon fidelities of 0.962 at 200 MHz versus 0.772 at 8 GHz, and triples the lower bound on quantum channel capacity. In conclusion, this method enables highly efficient networking of superconducting qubits while maintaining high fidelities, combining improved performance with the practical advantages of flexible, compact coaxial cables.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Simulations of the fault current limiting operation of a long-length REBCO CORC ® superconducting cable cooled by helium gas

Conductor-on-round-core (CORC®) cables composed of rare-earth-barium-copper-oxide high-temperature superconducting (HTS) tapes are of great interest for power transmission applications due to their many advantages such as high power density, light weight, and low loss. Closed circulation loops of cryogenic helium gas can be used to cool HTS cables down to low temperatures to significantly improve their current-carrying capacity. Coupled circuit-electromagnetic-thermal finite element simulations implemented in the COMSOL Multiphysics package were developed, validated, and then used for simulating the fault current limiting (FCL) performance and the cooling processes of an 8-layer CORC® cable cooled with a flow of cryogenic helium gas. In the simulations, the temperature dependence of the electrical and thermal properties of all component materials is implemented for improved accuracy. To overcome computational challenges caused by the considerable difference in geometrical scales (i.e. few-µm-thick HTS layers versus 10 m-long HTS cable), the model is divided into two separate simulations. The first simulation is performed on the transverse cross-section of the cable to calculate the electric field, heating power and temperature rise in each component of a CORC® cable during FCL operation. The heating power calculated in the first simulation is transferred to the second model to simulate the cooling of a 10 m-long cable after the fault is cleared. The effect of the helium gas flow rate on the cooling process is also investigated to develop strategic approaches for optimizing cooling systems for HTS cables with FCL capability. The simulations indicated that a 40 ms fault with a voltage drop of 20 V m −1 along the cable can result in a temperature increase from 60 K to about 165 K inside the cable, and it takes about 500 s to cool the cable back to nearly 60 K with a flow of cold helium gas at a rate of 5 g s −1 .

24 POWER TRANSMISSION AND DISTRIBUTION

Consideration of HTS rapid-cycling magnet for staged muon acceleration

The HTS conductor hysteresis dominates magnet cable power loss but is independent of the magnetic field ramping rate. This makes the HTS conductor suitable to power the rapid-cycling accelerator magnet. We present a possible application of the HTS rapid-cycling magnet as outlined in [1,2] for the staged muon acceleration including the front-end Recirculating Linear Accelerator and the followed-up Rapid Cycling Synchrotrons delivering the muon beams to the Muon Collider.[1] H. Piekarz, S. Otten, A. Kario, H. ten Kate, “Rapid-cycling HTS magnet for muon acceleration”, US MC Inaugural Meeting, FERMILAB-POSTER-24-0219-AD, August 7-9, 2024[2] H. Piekarz, B. Claypool, S. Hays, M. Kufer, V. Shiltsev, “Record High Ramping Rates in HTS Based Supercond. Accelerator Magnet”, MT 27, IEEE Trans. on Applied Superccond, 32 (2022) 6, 4100404

Piekarz, Henryk [Fermilab]

Return on Investment and Sustainability of HVDC Links: Role of Diagnostics, Condition Monitoring, and Material Innovations

HVDC cable systems are becoming an upscaled technical option, compared to AC, because of various factors, including easier interconnections, lower losses, and longer transmission distances. In addition, renewables providing direct DC energy, electrified transportation, and aerospace where DC can be favored because of higher carried specific power all point in the direction of broad future usage of HV and MV DC links. However, contrary to AC, there is little return from on-field installation as regards long-term cable reliability and aging processes. This gap must be covered by intensive research, and contributing to this research is the purpose of this paper. The focus is on key points for HVDC (and MVDC) cable reliability and sustainability, from design modeling able to account for voltage transients and extrinsic aging (such as that caused by partial discharges) to the impact of aging on insulation conductivity (which rules the electric field distribution, thus aging rate). Also, recyclable and nanostructured materials, as well as health conditions, are considered. It is shown how cable design can account for accelerated aging due to voltage transients, as well as for aging-time dependence of conductivity, and how design can be free of extrinsic aging caused by PDs. Algorithms for health condition evaluations, which have additional value in a relatively new technology such as HVDC polymeric cables, are applied to insulation system aging under partial discharges, showing how they can provide an indication of insulation degradation globally or locally (weak spots) and of possible maintenance times. All of this can effectively contribute to reducing the risk of major cable breakdown and damage under operation, which would significantly affect the return on investment (ROI).

Montanari, Gian Carlo (ORCID:0000000320258693)

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains Task 3: Lifetime and Reliability of Electrical Insulators

This research project was a collaborative investigation between researchers at the RTX Technology Research Center (RTRC) and the University of Texas at Austin and made a significant contribution to enabling electric aircraft. The transport of electric power between the points of generation and use requires power cables. These cables must be smaller, lighter and provide a more predictable life than power cables used in stationary applications. Consequently, this investigation provided heretofore unavailable information supporting the safety and reliability of smaller lighter power cables for electrified aircraft. In addition, the research identified key additional engineering data needed to support quantitative reliability assessments. Important advances included: • Demonstrated that at least one manufacturer can make a novel, smaller, lighter power cable that is free from serious defects. • Developed and published an appropriate analytical construct to describe the life of this novel cable. This is a necessary step for use in aviation where the understanding of remaining life is critical. • Demonstrated thermal-mechanical aging that suggested 1000+ flights before the thermal-mechanical processes produced defects large enough that the defect growth was accelerated electrically. • Showed that electrical aging took place at two rates. The first possibly lasting weeks to months and the second possibly days to weeks. If robust, this provides a good diagnostic for cable replacement. • Demonstrated that the traditional electrical testing of cable materials using manufactured voids can be misleading due to the size of the voids. Emerging laser drilling technology permitted demonstration that the physics of failure in realistically small voids is different from that in the unrealistically large voids used in earlier research, which is very important for high-quality, high-performance, small aircraft cables. Although this project represents a significant contribution to the specifics of cable aging in the aircraft environment, important additional research remains to be completed, including: • Non-uniform thermal cycling by applying the heat from the center conductor to maximize thermal stress next to the core area where the electric gradient is the strongest. This builds on the uniform thermal cycling that has been completed. • The augmentation of the thermal-mechanical failure rate by electrical processes. Better understanding of these time constants strongly affects the ability to predict life. • Termination design: Terminations provide not only electrical reflection potential, but a location for a series arc fault and an area where ozone can diffuse into the center conductor and negatively affect cable insulation. • The abrasion and ozone resistance of the cable jacket. • Pressure cycling as an accelerant of thermal, mechanical, and/or electrical aging. • Possible methods for online PD detection and offline PD localization

model

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY

Effect of Transverse Compression on the Dielectric Breakdown of Power Cable with Ethylene Propylene Rubber Insulation

Understanding of the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project explored a multiphysics approach and conducted systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15 kV power cable. The power cable had three cores of copper conductor and ethylene propylene rubber (EPR) insulation. An ETM testing system with transverse compression capability was developed. Mechanical loading induced dielectric breakdown. Increasing temperature from room temperature (RT, 22 degrees Celsius) to 90 degrees Celsius resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. With the same temperature rise, the creep mechanical load was reduced by 70% at a given dielectric breakdown time. The post-test measurement revealed an impressive recovery of electrical resistance, although the dielectric breakdown occurred in the ETM test that would not be captured without the use of ETM testing.

Wang, Hong [ORNL] (ORCID:0000000201730545)

Seismic DAS Observations of a large underground chemical explosion in dry tuff

On 18 October 2023 a 16.3-ton TNT equivalent chemical explosion was detonated underground at the Nevada National Security Site, generating a seismic event (Meyers et al., 2024). The associated seismic wavefield was measured on a Distributed Acoustic Sensing (DAS) array with slant range distances from 27 m – 1123 m. The first arriving phase traveled at an apparent velocity of about 2640 m s -1 from 27 m to 420 m slant range and about 2470 m s -1 from 505 m to 1123 m slant range according to the first arrival moveouts on the DAS data. The first arrival from the explosion temporarily saturated the cable from a slant range of 27 m – 186 m and 0.009 s to 0.084 s post detonation. From 186 m slant range to 420 m slant range, peak strain rates of 5.6 x 10 6 nm m -1 s -1 were observed for the first arrival phase. For the first arrival from 505 m slant range to 1123 m slant range, peak strain rates reduced to 8.0 x 10 4 nm m -1 s -1 . A comparison of the scaled accelerations computed from DAS, the geophone pairs, and the measurements of co-located accelerometer pairs show common agreement at the scaled ranges of the single point sensors. This study adds to the body of work reporting near-source DAS observations of the seismic wavefields generated by underground chemical explosions. These results indicate that near-source DAS observations can refine interpretations of phase identification from single-point sensor observations. Phase identification could be one mechanism that contributes scatter to single point seismic measurements which would confound the performance of empirical relationships for small explosions. Removing that mechanism may therefore reduce interstation variability and increase empirical relationship performance for small explosions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF

Seismic DAS observations of a large underground chemical explosion in dry tuff

On 18 October 2023 a 16.3-ton TNT equivalent chemical explosion was detonated underground at the Nevada National Security Site, generating a seismic event with a magnitude of 1.7 (Meyers et al., 2024). The associated seismic wavefield was measured on a Distributed Acoustic Sensing (DAS) array with slant range distances from 27 m – 1123 m. The first arriving phase traveled at an apparent velocity of about 2640 m s -1 from 27 m to 420 m slant range and about 2470 m s -1 from 505 m to 1123 m slant range according to the first arrival moveouts on the DAS data. The first arrival from the explosion temporarily saturated the cable from a slant range of 27 m – 186 m and 0.009 s to 0.084 s post detonation. From 186 m slant range to 420 m slant range, peak strain rates of 5.6 x 10 6 nm m -1 s -1 were observed for the first arrival phase. For the first arrival from 505 m slant range to 1123 m slant range, peak strain rates reduced to 8.0 x 104 nm m -1 s -1 . A comparison of the scaled accelerations computed from DAS, the geophone pairs, and the measurements of co-located accelerometer pairs show common agreement at the scaled ranges of the single point sensors. This study adds to the body of work reporting near-source DAS observations of the seismic wavefields generated by underground chemical explosions. These results indicate that near-source DAS observations can refine interpretations of phase identification from single-point sensor observations. Phase identification could be one mechanism that contributes scatter to single point seismic measurements which would confound the performance of empirical relationships for small explosions. Removing that mechanism may therefore reduce interstation variability and increase empirical relationship performance for small explosions.

58 GEOSCIENCES

Reese Housing Power Project (Final Technical Report)

The Reese Housing Power Project is located on Tribal trust land in Colusa, CA and expands existing medium-voltage distribution to seven new households with the addition of medium-voltage cabling, step down transformers, smart meters, and street lighting for the new development. The Tribe utilized their existing Co-Generation power plant and micro grid to supply the new homes with highly reliable power with fewer interruptions and at a reduced rate compared with the local utility. The project gives the Tribe greater independence from traditional power sources and provides jobs for the community. The project reduces electric energy costs, increases Tribe self-reliance, and provides highly reliable electric power to seven tribal members’ homes. Construction of the project also provided jobs for the community.

24 POWER TRANSMISSION AND DISTRIBUTION

Monitoring strain evolution in water-sand systems using distributed acoustic sensing for geohazard early warning

Rainfall-driven hazards such as landslides, debris flows, and earthen dam failures often arise when water changes the internal strain within sand. This study evaluates the ability of distributed acoustic sensing to monitor these strain changes in real time. We embed a fiber-optic cable in a sand-filled glass cylinder and run controlled dry- and wet-sand experiments to measure how strain develops as water infiltrates, saturates, and drains from the sand. The sensing system detects uneven water movement in dry sand and enables millimeter-scale estimates of infiltration rates, and in wet sand it tracks rising water levels, delayed strain peaks after saturation, and abrupt strain shifts during drainage. These results show that fiber-optic sensing captures subtle strain evolution throughout the full water-sand interaction cycle. The study demonstrates that fiber-optic sensing offers promising potential for real-time and cost-effective monitoring and early warning of rainfall-induced geohazards.

58 GEOSCIENCES

Development of a capacitance measurement for pulsed magnetic fields

Capacitance measurements are crucial for probing the electrical properties of materials. In this study, we develop and implement a capacitance measurement technique optimized for pulsed magnetic fields. Our approach employs an auto-balancing bridge method, leveraging a high-bandwidth transimpedance amplifier to mitigate parasitic contributions from coaxial cables. This technique enables precise capacitance measurements in rapidly changing magnetic fields, as demonstrated in experiments on the magnetoelectric material NiCo 2 TeO 6 . The results reveal strong magnetoelectric coupling, including a pronounced hysteresis in capacitance that coincides with magnetization measurements and an enhanced energy dissipation peak at high sweep rates. Compared to traditional LCR meter measurements in DC fields, our method exhibits excellent agreement while providing additional insight into field-induced phase transitions. This work establishes a robust methodology for capacitance measurements under extreme conditions and opens new opportunities for studying multiferroic and correlated electron systems under high magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Fe Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. Effective monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of Fe-coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscatterring reflectometer (OBR), corrosion was monitored based on the increase in backscattered intensity amplitude of the light being passed as Fe undergoes corrosion. The Fe-coated OFSs were prepared with a film thickness between 25-225 nm by an electroless plating approach and corroded by a CO2-saturated acidic electrolyte. The corrosion rate was approximately 2.5 mm/yr for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based corrosion rates were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during corrosion of Fe was established. Corrosion was measurable out to > 100 m which is a significant improvement over our previous work showing corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at >1 ft depth. Fe-coated OFS was loaded into a Draka cable which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil.

aqueous environment

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion sensor was also tested in soil at > 1 foot depth. Fe-coated OFS was loaded into a Draka cable, which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil (50/50).

corrosion