Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “buses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Redundant Buses For Loosely Coupled Dual Computers

Digital electronic network contains two data processors loosely coupled to each other and to four remote terminals via three MIL-STD-1553B data buses. Three-bus configuration provides redundancy for protection against failure of one of the processors and against failures of one or two buses. Triple-bus architecture used for fault tolerance in similar terrestrial digital electronic systems.

Katz, Richard B.↗

Conceptual Design of the TPF-O SC Buses

The Terrestrial Planet Finder - Occulter (TPF-O) mission has two Spacecraft (SC) buses, one for a space telescope and the other for a formation-flying occulter. SC buses typically supply the utilities (support structures, propulsion, attitude control, power, communications, etc) required by the payloads. Unique requirements for the occulter SC bus are to provide the large delta V required for the slewing maneuvers of the occulter, and comunications for formation flying. The TPF-O telescope SC bus shares some key features of the one for the Hubble Space Telescope (HST): both support space telescopes designed to observe in the visible to near infrared range of wavelengths with comparable primary mirror apertures (2.4 m for HST, 2.4 - 4.0 m for TPF-O). However, TPF-O is expected to have a Wide Field Camera (WFC) with a Field of View (FOV) much larger than that of HST. Ths WFC is also expected to provide fine guidance. TPF-O is designed to operate in an orbit around the Sun-Earth Lagrange 2 (SEL2) point. The longer communications range to SEL2 and the large science FOV require higher performance communications than HST. Maintaining a SEL2 orbit requires TPF-O, unlike HST, to have a propulsion system. The velocity required for reachng SEL2 and the limited capabilities of affordable launch vehicles require both TPF-O elements to have compact, low-mass designs. Finally, it is possible that TPF-O may utilize a modular design derived fiom that of HST to allow servicing in the SEL2 orbit.

Purves, Lloyd R.↗

Resistojet control and power for high frequency ac buses

Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

Gruber, Robert P.↗

Resistojet control and power for high frequency ac buses

Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

Gruber, Robert P.↗

Unit Monitors Manchester-Format Data Buses

Circuit card converts data signals into convenient hexadecimal form for troubleshooting. Bus-monitoring unit converts data signals from Manchester II format used on data bus into hexadecimal format. Monitoring circuit causes hexadecimal words to display on video terminal, where test engineer compares them with hexadecimal records for troubleshooting. Circuit monitors one bus or two buses simultaneously.

Amador, Jose J.↗

DOT/NASA comparative assessment of Brayton engines for guideway vehicle and buses. Volume 1: Summary

The Department of Transportation requested that the NASA Office of Aeronautics and Space Technology evaluate and assess the potential of several types of gas turbine engines and fuels for the on-board power and propulsion of a future heavy-duty ground transportation system. The purpose of the investigation was threefold: (1) to provide a definition of the potential for turbine engines to minimize pollution, energy consumption, and noise; (2) to provide a useful means of comparison of the types of engine based on consistent assumptions and a common analytical approach; and (3) to provide a compendium of comparative performance data that would serve as the technical basis for future planning. Emphasis was on establishing comparison trends rather than on absolute values and a definitive engine selection. The primary value of this study is intended to be usefulness of the results to provide a quantitative basis for future judgement.

Source record↗

Quality assurance program guidelines for application to and use by manufacturers of rail/guideway vehicles, buses, automatic train control systems, and their major subsystems

Guidelines are presented for a quality assurance system to be implemented by the manufacturer in support of designing, developing, fabricating, assembling, inspecting, testing, handling, and delivery of equipment being procured for use in public urban mass transit systems. The guidelines apply to this equipment when being procured for: (1) use in revenue service; (2) demonstration of systems that will be revenue producing or used by the public; (3) use as a prototype for follow-on operational/revenue producing equipment procurements; and (4) qualification tests.

Witkin, S. A.↗

Test apparatus for locating shorts during assembly of electrical buses

A test apparatus is described for locating electrical shorts that is especially suited for use while an electrical circuit is being fabricated or assembled. A ring counter derives input pulses from a square wave oscillator. The outputs of the counter are fed through transistors to an array of light emitting diodes. Each diode is connected to an electrical conductor, such as a bus bar, that is to be tested. In the absence of a short between the electrical conductors the diodes are sequentially illuminated. When a short occurs, a comparator/multivibrator circuit triggers an alarm and stops the oscillator and the sequential energization of the diodes. The two diodes that remain illuminated identify the electrical conductors that are shorted.

Deboo, G. J.↗

Demonstration and evaluation of gas turbine transit buses

The Gas Turbine Transit Bus Demonstration Program was designed to demonstrate and evaluate the operation of gas turbine engines in transit coaches in revenue service compared with diesel powered coaches. The main objective of the program was to accelerate development and commercialization of automotive gas turbines. The benefits from the installation of this engine in a transit coach were expected to be reduced weight, cleaner exhaust emissions, lower noise levels, reduced engine vibration and maintenance requirements, improved reliability and vehicle performance, greater engine braking capability, and superior cold weather starting. Four RTS-II advanced design transit coaches were converted to gas turbine power using engines and transmissions. Development, acceptance, performance and systems tests were performed on the coaches prior to the revenue service demonstration.

Source record↗

Description and planned use of a data distribution evaluation system for fiber optic data buses

A general description of a laboratory data distribution evaluation system (DDES) is given and some plans to use the system. The DDES is a microprocessor-based evaluation system consisting of three identical terminals. The DDES provides the capability for evaluating different system protocols and data word structures by making appropriate software changes, and different transmission medias and modulation schemes by making front-end hardware changes. A data multiplexing standard for fiber optic data transmission which parallels MIL-STD-1553B has proposed four different data modulation schemes. These modulation schemes will be described along with the plans to evaluate each of them. NASA-Langley has also been developing a data distribution approach which utilizes optical wavelength division multiplexing (WDM). A four-port, four-wavelength WDM system will be described along with the planned use of the DDES to evaluate its performance.

Spencer, J. L.↗

Thermal control - Heat buses will operate like a public utility

Active thermal control for the NASA space station concept requires long life heat rejection, highly versatile thermal transport, and efficient system integration. By a significant margin, the heat radiator will be the largest and most exposed portion of the space station thermal system. Transport requirements encompass the collection and movement of thermal energy from the space station's heat sources to the radiator heat sink at required temperature levels. In a decentralized thermal system, each space station module would collect and reject all of the waste heat generated, thereby requiring no module interconnections. This scheme does not, however, allow waste heat from one module to be used by another. In a centralized system, heat must be transported across module boundaries. A high capacity monogroove heat pipe has been developed to simplify space radiators design and operation.

Ellis, W. E.↗

Performance modeling and measurement of real-time multiprocessors with time-shared buses

A closed queueing network model is constructed to address workload effects on computer performance for a highly reliable unibus multiprocessor used in real-time control. The queueing model consists of multiserver nodes and a nonpreemptive priority queue. Use of this model requires partitioning the workload into task classes. The time average steady-state solution of the queueing model directly produces useful results that are necessary in performance evaluation. The model is experimentally justified with the Fault-Tolerant Multiprocessor (FTMP) located at the NASA AIRLAB. Extensive experiments are performed on FTMP with a synthetic workload generator (SWG) to directly measure performance parameters, such as processor idle time, system bus contention, and task processing times. These measurements determine values for parameters in the queueing model. Experimental and analytic results are then compared.

Woodbury, Michael H.↗

Definition, analysis and development of an optical data distribution network for integrated avionics and control systems

The potential and functional requirements of fiber optic bus designs for next generation aircraft are assessed. State-of-the-art component evaluations and projections were used in the system study. Complex networks were decomposed into dedicated structures, star buses, and serial buses for detailed analysis. Comparisons of dedicated links, star buses, and serial buses with and without full duplex operation and with considerations for terminal to terminal communication requirements were obtained. This baseline was then used to consider potential extensions of busing methods to include wavelength multiplexing and optical switches. Example buses were illustrated for various areas of the aircraft as potential starting points for more detail analysis as the platform becomes definitized.

Burns, R. R.↗

The Design of a Fault-Tolerant COTS-Based Bus Architecture

In this paper, we report our experiences and findings on the design of a fault-tolerant bus architecture comprised of two COTS buses, the IEEE 1394 and the 12C. This fault-tolerant bus is the backbone system bus for the avionics architecture of the X2000 program at the Jet Propulsion Laboratory. COTS buses are attractive because of the availability of low cost commercial products. However, they are not specifically designed for highly reliable applications such as long-life deep-space missions. The X2000 design team has devised a multi-level fault tolerance approach to compensate for this shortcoming of COTS buses. First, the approach enhances the fault tolerance capabilities of the IEEE 1394 and 12 C buses by adding a layer of fault handling hardware and software. Second, algorithms are developed to enable the IEEE 1394 and the 12 C buses assist each other to isolate and recovery from faults. Third, the set of IEEE 1394 and 12 C buses is duplicated to further enhance system reliability. The X2000 design team has paid special attention to guarantee that all fault tolerance provisions will not cause the bus design to deviate from the commercial standard specifications. Otherwise, the economic attractiveness of using COTS will be diminished. The hardware and software design of the X2000 fault-tolerant bus are being implemented and flight hardware will be delivered to the ST4 and Europa Orbiter missions.

Chau, Savio N.↗

Efficient and Robust Data Collection Using Compact Micro Hardware, Distributed Bus Architectures and Optimizing Software

Future In-Space propulsion systems for exploration programs will invariably require data collection from a large number of sensors. Consider the sensors needed for monitoring several vehicle systems states of health, including the collection of structural health data, over a large area. This would include the fuel tanks, habitat structure, and science containment of systems required for Lunar, Mars, or deep space exploration. Such a system would consist of several hundred or even thousands of sensors. Conventional avionics system design will require these sensors to be connected to a few Remote Health Units (RHU), which are connected to robust, micro flight computers through a serial bus. This results in a large mass of cabling and unacceptable weight. This paper first gives a survey of several techniques that may reduce the cabling mass for sensors. These techniques can be categorized into four classes: power line communication, serial sensor buses, compound serial buses, and wireless network. The power line communication approach uses the power line to carry both power and data, so that the conventional data lines can be eliminated. The serial sensor bus approach reduces most of the cabling by connecting all the sensors with a single (or redundant) serial bus. Many standard buses for industrial control and sensor buses can support several hundreds of nodes, however, have not been space qualified. Conventional avionics serial buses such as the Mil-Std-1553B bus and IEEE 1394a are space qualified but can support only a limited number of nodes. The third approach is to combine avionics buses to increase their addressability. The reliability, EMI/EMC, and flight qualification issues of wireless networks have to be addressed. Several wireless networks such as the IEEE 802.11 and Ultra Wide Band are surveyed in this paper. The placement of sensors can also affect cable mass. Excessive sensors increase the number of cables unnecessarily. Insufficient number of sensors may not provide adequate coverage of the system. This paper also discusses an optimal technique to place and validate sensors.

micro hardware↗

Command Interface ASIC - Analog Interface ASIC Chip Set

A command interface application-specific integrated circuit (ASIC) and an analog interface ASIC have been developed as a chip set for remote actuation and monitoring of a collection of switches, which can be used to control generic loads, pyrotechnic devices, and valves in a high-radiation environment. The command interface ASIC (CIA) can be used alone or in combination with the analog interface ASIC (AIA). Designed primarily for incorporation into spacecraft control systems, they are also suitable for use in high-radiation terrestrial environments (e.g., in nuclear power plants and facilities that process radioactive materials). The primary role of the CIA within a spacecraft or other power system is to provide a reconfigurable means of regulating the power bus, actuating all valves, firing all pyrotechnic devices, and controlling the switching of power to all switchable loads. The CIA is a mixed-signal (analog and digital) ASIC that includes an embedded microcontroller with supporting fault-tolerant switch control and monitoring circuitry that is capable of connecting to a redundant set of interintegrated circuit (I(sup 2)C) buses. Commands and telemetry requests are communicated to the CIA. Adherence to the I(sup 2)C bus standard helps to reduce development costs by facilitating the use of previously developed, commercially available components. The AIA is a mixed-signal ASIC that includes the analog circuitry needed to connect the CIA to a custom higher powered version of the I(sup 2)C bus. The higher-powered version is designed to enable operation with bus cables longer than those contemplated in the I(sup 2)C standard. If there are multiple higher-power I(sup 2)C-like buses, then there must an AIA between the CIA and each such bus. The AIA includes two identical interface blocks: one for the side-A I(sup 2)C clock and data buses and the other for the side B buses. All the AIAs on each side are powered from a common power converter module (PCM). Sides A and B of the I(sup 2)C buses are electrically isolated from each other (see figure). They are also isolated from the CIA by use of transformer coupling of signals between the AIA blocks and the CIA.

Ruiz, Baldes↗