Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bulk data transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Studying NASA's Transition to Ka-Band Communications for Low Earth Orbit

As the S-band spectrum becomes crowded, future space missions will need to consider moving command and telemetry services to Ka-band. NASA's Space Communications and Navigation (SCaN) Testbed provides a software-defined radio (SDR) platform that is capable of supporting investigation of this service transition. The testbed contains two S-band SDRs and one Ka-band SDR. Over the past year, SCaN Testbed has demonstrated Ka-band communications capabilities with NASAs Tracking and Data Relay Satellite System (TDRSS) using both open- and closed-loop antenna tracking profiles. A number of technical areas need to be addressed for successful transition to Ka-band. The smaller antenna beamwidth at Ka-band increases the criticality of antenna pointing, necessitating closed loop tracking algorithms and new techniques for received power estimation. Additionally, the antenna pointing routines require enhanced knowledge of spacecraft position and attitude for initial acquisition, versus an S-band antenna. Ka-band provides a number of technical advantages for bulk data transfer. Unlike at S-band, a larger bandwidth may be available for space missions, allowing increased data rates. The potential for high rate data transfer can also be extended for direct-to-ground links through use of variable or adaptive coding and modulation. Specific examples of Ka-band research from SCaN Testbeds first year of operation will be cited, such as communications link performance with TDRSS, and the effects of truss flexure on antenna pointing.

space communications↗

Studying NASA's Transition to Ka-Band Communications for Low Earth Orbit

As the S-band spectrum becomes crowded, future space missions will need to consider moving command and telemetry services to Ka-band. NASAs Space Communications and Navigation (SCaN) Testbed provides a software-defined radio (SDR) platform that is capable of supporting investigation of this service transition. The testbed contains two S-band SDRs and one Ka-band SDR. Over the past year, SCaN Testbed has demonstrated Ka-band communications capabilities with NASAs Tracking and Data Relay Satellite System (TDRSS) using both open- and closed-loop antenna tracking profiles. A number of technical areas need to be addressed for successful transition to Ka-band. The smaller antenna beamwidth at Ka-band increases the criticality of antenna pointing, necessitating closed loop tracking algorithms and new techniques for received power estimation. Additionally, the antenna pointing routines require enhanced knowledge of spacecraft position and attitude for initial acquisition, versus an S-band antenna. Ka-band provides a number of technical advantages for bulk data transfer. Unlike at S-band, a larger bandwidth may be available for space missions, allowing increased data rates. The potential for high rate data transfer can also be extended for direct-to-ground links through use of variable or adaptive coding and modulation. Specific examples of Ka-band research from SCaN Testbeds first year of operation will be cited, such as communications link performance with TDRSS, and the effects of truss flexure on antenna pointing.

International Space Station↗

CCD data acquisition systems at Lick and Keck Observatories

This paper will describe and compare two distinct but related CCD data acquisition systems (DAS) currently under development at Lick and Keck Observatories. Although these two systems have a number of major architectural differences, they share a considerable amount of common hardware and software. Both of these new systems build on a large body of proven software that is the foundation of the existing CCD DAS currently in use at Lick Observatory. Both will provide support for reading up to four on-chip amplifiers per CCD and/or reading out mosaics of CCD chips. In addition, they will provide the capability for interactive, real-time adjustment of CCD waveforms for engineering purposes. Each of these two systems is composed of three major subsystems: (1) an instrument computer and its software; (2) a data capture computer and its software; and (3) a CCD/dewar controller and its software. The instrument computer is a Unix workstation, and the functions it provides include user interfaces, the interactive real-time display of CCD images, and the recording of image and FITS header data to disk and/or tape. The data capture computer is responsible for the packaging and high-speed transfer of the CCD pixel data stream into a bulk RAM, and the subsequent transfer of this data to the instrument computer. The CCD/dewar controller generates the waveforms for clocking the CCD, digitizes the pixel data, and transmits it via high-speed link to the data capture computer. It is also responsible for monitoring and controlling the dewar temperature and cryogen levels. Given the number of different types of processors and high-speed data links employed in both systems, a major emphasis of this paper will be on the various forms of interprocessor communications utilized for data transfer and distributed process synchronization.

Kibrick, R. I.↗

The image-processing system for the Earth Resources Technology Satellite.

Description of the image-processing system for the Earth Resources Technology Satellite (ERTS), which will process video-tape recordings received from the satellite into imagery and digitized video data suitable for earth-resource study and analysis. The system is made up of three subsystems. The bulk processor produces 70-mm images and digitized records, corrected for systematic geometric and radiometric errors as well as for sensor-calibration and other errors. The precision processor modifies the bulk images to significantly increase geometric precision. The special processor transfers either bulk or precision data to computer-compatible tape.

Johnson, R. H.↗

Heat-Transfer and Friction Measurements with Variable Properties for Airflow Normal to Finned and Unfinned Tube Banks

A single-line correlation of both the heat-transfer and pressure- drop data for electrically heated unfinned tubes is obtained by evaluating the density in the Reynolds number, specific heat, thermal conductivity, and viscosity at the film temperature, and the density in the friction coefficient at the bulk temperature. The heat-transfer data for finned tubes also exhibit an effect of physical-property variation which is removed by evaluating all properties, including density, at the primary surface temperature, and using k* = 0.015 square root of T/530 for the thermal conductivity of air where T is the absolute temperature. The pressure drop for finned tubes is correlated by the use of bulk density in both the Reynolds number and friction coefficient. The data reported are for Reynolds numbers from 2000 to 35,000, surface temperatures from 600 to 1400 R, and an air inlet temperature of 530 R.

Ragsdale, Robert G.↗

Volume-energy parameters for heat transfer to supercritical fluids

Reduced Nusselt numbers of supercritical fluids from different sources were grouped by several volume-energy parameters. A modified bulk expansion parameter was introduced based on a comparative analysis of data scatter. Heat transfer experiments on liquefied methane were conducted under near-critical conditions in order to confirm the usefulness of the parameters. It was experimentally revealed that heat transfer characteristics of near-critical methane are similar to those of hydrogen. It was shown that the modified bulk expansion parameter and the Gibbs-energy parameter grouped the heat transfer data of hydrogen, oxygen and methane including the present data on near-critical methane. It was also indicated that the effects of surface roughness on heat transfer were very important in grouping the data of high Reynolds numbers.

A. Kumakawa↗

The performance of cable braids and terminations to lightning induced transients

The latest specification detailing the test waveforms for indirect lightning transients as applied to aircraft wiring systems specify very high voltages and currents. Although considerable data exists for measuring cable screen leakage using such methods as surface transfer impedance and bulk cable injection, there is little data on the likely core transient level that is likely to be induced from these threats. In particular, the new Waveform 5 at very high current levels (10 kA) is reputed to cause severe cable damage. A range of representative cables were made with various screen termination techniques and screening levels. These were tested first to determine their relative screening performance and then they were subjected to lightning transient testing to all the specified waveforms. Core voltages were measured for each test. Tests were also performed on bundles with fewer wires to determine the failure criteria with Waveform 5 and these tests also include flat conductor cables. The test showed that correctly terminated cable bundles performed well in all the tests and would provide a high level of protection to the electronic systems. The use of overbraides, provided the individual screens are well terminated, appears to be unnecessary.

Crofts, David↗

Experimental Investigation of Gas-Side Performance of a Compact Finned-Tube Heat Exchanger

Heat-transfer and pressure-drop data were obtained experimentally for the gas side of a liquid-metal to air, compact finned-tube heat exchanger. The heat exchanger was fabricated from 0.185-inch Inconel tubing in an inline array. The fins were made of 310 stainless-steel- clad copper with a total thickness of 0.010 inch, and the fin pitch was 15.3 fins per inch. The liquid used as the heating medium was sodium. The heat-exchanger inlet gas temperature was varied from 5100 to 1260 R by burning JP fuel for airflow rates of 0.4 to 10.5 pounds per second corresponding to an approximate Reynolds number range of 300 to 9000. The sodium inlet temperature was held at 1400 R with the exception of a few runs taken at 1700 and 1960 R. The maximum ratio of surface temperature to air bulk temperature was 1.45. Friction-factor data with heat transfer were best represented by a single line when the density and viscosity of Reynolds number were evaluated at the average film temperature. At the lower Reynolds numbers reported, the friction data with heat transfer plotted slightly above the friction data without heat transfer. The density of the friction factor was calculated at the average bulk temperature. Heat-transfer results of this investigation were correlated by evaluating the physical properties of air (specific heat, viscosity, and thermal conductivity) at the film temperature.

Gedeon, Louis↗

Experimental Investigation of Average Heat-Transfer and Friction Coefficients for Air Flowing in Circular Tubes Having Square-Thread-Type Roughness

An investigation of forced-convection heat transfer and associated pressure drops was conducted with air flowing through electrically heated Inconel tubes having various degrees of square-thread-type roughness, an inside diameter of 1/2 inch, and a length of 24 inches. were obtained for tubes having conventional roughness ratios (height of thread/radius of tube) of 0 (smooth tube), 0.016, 0.025, and 0.037 over ranges of bulk Reynolds numbers up to 350,000, average inside-tube-wall temperatures up to 1950deg R, and heat-flux densities up to 115,000 Btu per hour per square foot. Data The experimental data showed that both heat transfer and friction increased with increase in surface roughness, becoming more pronounced with increase in Reynolds number; for a given roughness, both heat transfer and friction were also influenced by the tube wall-to-bulk temperature ratio. Good correlation of the heat-transfer data for all the tubes investigated was obtained by use of a modification of the conventional Nusselt correlation parameters wherein the mass velocity in the Reynolds number was replaced by the product of air density evaluated at the average film temperature and the so-called friction velocity; in addition, the physical properties of air were evaluated at the average film temperature. The isothermal friction data for the rough tubes, when plotted in the conventional manner, resulted in curves similar to those obtained by other investigators; that is, the curve for a given roughness breaks away from the Blasius line (representing turbulent flow in smooth tubes) at some value of Reynolds number, which decreases with increase in surface roughness, and then becomes a horizontal line (friction coefficient independent of Reynolds number). A comparison of the friction data for the rough tubes used herein indicated that the conventional roughness ratio is not an adequate measure of relative roughness for tubes having a square-thread-type element. The present data, as well as those of other investigators, were used to isolate the influence of ratios of thread height to width, thread spacing to width, and the conventional roughness ratio on the friction coefficient. A fair correlation of the friction data was obtained for each tube with heat addition when the friction coefficient and Reynolds number were defined on the basis of film properties; however, the data for each tube retained the curve characteristic of that particular roughness. The friction data for all the rough tubes could be represented by a single line for the complete turbulence region by incorporating a roughness parameter in the film correlation. No correlation was obtained for the region of incomplete turbulence.

Sams, E. W.↗

Internal low Reynolds number turbulent heat transfer

The results of a semi-analytical and experimental study of adiabatic tube flow and an analytical and experimental investigation of the thermal entrance region for gas flowing through electrically heated circular tubes are presented. Emphasis is placed on the low Reynolds number turbulent flow regime--defined as fully turbulent flow at bulk Reynolds numbers from 3,000 to about 15,000. Adiabatic air velocity and friction data and localized heat transfer measurements for air and helium, at low heating rates, are presented for this range. The adiabatic data were obtained in a 1.61 inch 1D tube for flow at bulk Reynolds numbers from 3,000 to 15,000. A continuous, Reynolds number-dependent, profile is developed from the data by using a modification of Reichardts' wall and middle law eddy diffusivity expressions. The velocity profile satisfies continuity. It is valid for all Reynolds numbers in excess of 3,000 for which the flow is fully turbulent and the Blasius friction factor expression is valid. The thermal entrance problem for a fully developed velocity profile is solved analytically by the method of Sparrow, Hallman, and Siegel. The solution is based on the profile developed from the velocity study. Tabular values of the eigenvalues and normalized Nusselt numbers for gases are presented for it range of Reynolds numbers from 3,000 to 50,000. The axial variation of Nusselt number is found to be correlated by [Nu/Nu_(∞)] = 1 + 0.8 (1+ 70,000 Re^(-3/2)) ((x/D)^(-1)) to within ± 5 per cent for x/D ≥2. The fully developed value agrees with the Dittus - Boelter correlation, Nu_(∞) = 0.021 Re^(0.8) Pr^(0.4) For the eigenvalues, λ^(2)_(n), and the associated constants, A_(n), correlations of the form λ^(2)_(n) =A_(1,n) Re^(-b_(1,n) + C_(1,n) Re^(-d_(1,n)) A_(n) = -A_(2,n) Re^(-b_(2,n) + C_(2,n) Re^(-d_(2,n)) are obtained. The coefficients and powers are presented in tabular form. Heat transfer data are presented, primarily for helium, for the low Reynolds number turbulent range. A one-quarter inch, resistively heated, vertical, circular tube was used for the study. The data cover an axial range from 1.2 to 96 diameters; wall-to-bulk temperature ratios vary from 1 to 1.4. In the low Reynolds number turbulent regime, these data clearly support the present analytical solution rather than the prediction obtained by applying the eddy diffusivity distribution used by Sparrow, Hallman, and Siegel.

Harold C. Reynolds, Jr.↗

Simplified and refined structural modeling for economical flutter analysis and design

A coordinated use of two finite-element models of different levels of refinement is presented to reduce the computer cost of the repetitive flutter analysis commonly encountered in structural resizing to meet flutter requirements. One model, termed a refined model (RM), represents a high degree of detail needed for strength-sizing and flutter analysis of an airframe. The other model, called a simplified model (SM), has a relatively much smaller number of elements and degrees-of-freedom. A systematic method of deriving an SM from a given RM is described. The method consists of judgmental and numerical operations to make the stiffness and mass of the SM elements equivalent to the corresponding substructures of RM. The structural data are automatically transferred between the two models. The bulk of analysis is performed on the SM with periodical verifications carried out by analysis of the RM. In a numerical example of a supersonic cruise aircraft with an arrow wing, this approach permitted substantial savings in computer costs and acceleration of the job turn-around.

Ricketts, R. H.↗

Heat Transfer from High-Temperature Surfaces to Fluids. III - Correlation of Heat-Transfer Data for Air Flowing in Silicon Carbide Tube with Rounded Entrance, Inside Diameter of 3/4 Inch, and Effective Length of 12 Inches: Correlation of Heat-Transfer Data for Air Flowing in Silicon Carbide Tube with Rounded Entrance, Inside Diameter of 3/4 Inch, and Effective Length of 12 Inches - Part 3

A heat-transfer investigation was conducted with air flowing through an electrically heated silicon carbide tube with a rounded entrance, an inside diameter of 3/4 inch, and an effective heat-transfer length of 12 inches over a range of Reynolds numbers up to 300,000 and a range of average inside-tube-wall temperature up to 2500 R. The highest corresponding local outside-tube-wall temperature was 3010 R. Correlation of the heat-transfer data using the conventional Nueselt relation wherein physical properties of the fluid were evaluated at average bulk temperature resulted in a separation of data with tube-wall-temperature level. A satisfactory correlation of the heat-transfer data was obtained, however, by the use of modified correlation parameters wherein the mass velocity G (or product of average air density and velocity evaluated at bulk temperature P(sub b)V(sub b)) in the Reynolds number was replaced by the product of average air velocity evaluated at the bulk temperature and density evaluated at either the average inside-tube-wall temperature or the average film temperature; in addition, all the physical properties of air were correspondingly evaluated at either the average inside-tube-wall temperature or the average film temperature.

Sams, Eldon W.↗

Measurements of surface energy budgets in the rocky mountains of Colorado

The surface energy balance of a mountain valley and a mountain peak were continuously monitored for periods of 126 and 34 days, respectively. The data yielded temporally resolved, high-quality measurements of the radiative, soil, and total atmospheric turbulent heat fluxes. Comparative data for the two sites reveal the effects of terrain setting and surface cover in modulating the heat balance. A procedure is suggested for accommodating local advective affects due to variable terrain and surface cover to allow partitioning of the total turbulent flux into values for sensible and latent heat. This procedure relies on a stability-dependent coefficient of turbulent transfer which is locally calibrated to systematically minimize advection-related errors. Scaling functions for the transfer coeffient are based on the effective blackbody temperature of the surface. Consequently, the procedure offers an opportunity for developing reliable bulk representations of heat transfer at the surface for use with remote sensing data and with models of the soil and surface cover in complex terrain.

Sheaffer, John D.↗

Two-Phase Convection Heat Transfer Correlations for Liquid Hydrogen Pipe Chilldown

Recently, heat transfer correlations based on liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching data were developed to improve the predictive accuracy of lumped node codes like SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP). After implementing these correlations into both programs, updated model runs showed strong improvement in LN2 pipe chilldown modeling but only modest improvement in LH2 modeling. Due to large differences in thermal and fluid properties between the two fluids, results indicated a need to develop a separate set of LH2-only correlations to improve the accuracy of the simulations. This paper presents a new set of two-phase convection heat transfer correlations based on LH2 pipe quenching data. A correlation to predict the bulk vapor temperature was developed after analysis showed that high amounts of thermal nonequilibrium of the liquid and vapor phases occurred during film boiling of LH2. Implemented in a numerical model, the new correlations achieve a mean absolute error of 19.5 K in the predicted wall temperature when compared to recent LH2 pipe chilldown data, an improvement of 40% over recent GFSSP predictions. This correlation set can be implemented in simulations of the transient LH2 chilldown process. Such simulations are useful for predicting the chilldown time and boil-off mass of LH2 for applications such as the transfer of LH2 from a ground storage tank to the rocket vehicle propellant tank, or through a rocket engine feedline during engine startup.

critical heat flux↗

Heat transfer from high-temperature surfaces to fluids II : correlation of heat-transfer and friction data for air flowing in inconel tube with rounded entrance

A heat transfer investigation, which was an extension of a previously reported NACA investigation, was conducted with air flowing through an electrically heated inconel tube with a rounded entrance,an inside diameter of 0.402 inch, and a length of 24 inches over a range of conditions, which included Reynolds numbers up to 500,000, average surface temperatures up to 2050 degrees R, and heat-flux densities up to 150,000 Btu per hour per square foot. Conventional methods of correlating heat-transfer data wherein properties of the air were evaluated at the average bulk, film, and surface temperatures resulted in reductions of Nusselt number of about 38, 46, and 53 percent, respectively, for an increase in surface temperature from 605 degrees to 2050 degrees R at constant Reynolds number. A modified correlation method in which the properties of air were based on the surface temperature and the Reynolds number was modified by substituting the product of the density at the inside tube wall and the bulk velocity for the conventional mass flow per unit cross-sectional area, resulted in a satisfactory correlation of the data for the extended ranges of conditions investigated.

Lowdermilk, Warren H↗

Experimental Heat Transfer and Bulk Air Temperature Measurements for a Multipass Internal Cooling Model with Ribs and Bleed

An experimental study was made to obtain heat transfer and air temperature data for a simple 3-leg serpentine test section that simulates a turbine blade internal cooling passage with trip strips and bleed holes. The objectives were to investigate the interaction of ribs and various bleed conditions on internal cooling and to gain a better understanding of bulk air temperature in an internal passage. Steady state heat transfer measurements were obtained using a transient technique with thermochromic liquid crystals. Trip strips were attached to one wall of the test section and were located either between or near the bleed holes. The bleed holes, used for film cooling, were metered to simulate the effect of external pressure on the turbine blade. Heat transfer enhancement was found to be greater for ribs near bleed holes compared to ribs between holes, and both configurations were affected slightly by bleed rates upstream. Air temperature measurements were taken at discreet locations along one leg of the model. Average bulk air temperatures were found to remain fairly constant along one leg of the model.

Thurman, Douglas↗

A practical large scale/high speed data distribution system using 8 mm libraries

Eight mm tape libraries are known primarily for their small size, large storage capacity, and low cost. However, many applications require an additional attribute which, heretofore, has been lacking -- high transfer rate. Transfer rate is particularly important in a large scale data distribution environment -- an environment in which 8 mm tape should play a very important role. Data distribution is a natural application for 8 mm for several reasons: most large laboratories have access to 8 mm tape drives, 8 mm tapes are upwardly compatible, 8 mm media are very inexpensive, 8 mm media are light weight (important for shipping purposes), and 8 mm media densely pack data (5 gigabytes now and 15 gigabytes on the horizon). If the transfer rate issue were resolved, 8 mm could offer a good solution to the data distribution problem. To that end Exabyte has analyzed four ways to increase its transfer rate: native drive transfer rate increases, data compression at the drive level, tape striping, and homogeneous drive utilization. Exabyte is actively pursuing native drive transfer rate increases and drive level data compression. However, for non-transmitted bulk data applications (which include data distribution) the other two methods (tape striping and homogeneous drive utilization) hold promise.

Howard, Kevin↗

Estimating monthly averaged air-sea transfers of heat and momentum using the bulk aerodynamic method

Air-sea transfers of sensible heat, latent heat and momentum are computed from 25 years of middle-latitude and subtropical ocean weather ship data in the North Atlantic and North Pacific using the bulk aerodynamic method. The results show that monthly averaged wind speeds, temperatures and humidities can be used to estimate the monthly averaged sensible and latent heat fluxes from the bulk aerodynamic equations to within a relative error of approximately 10%. The estimates of monthly averaged wind stress under the assumption of neutral stability are shown to be within approximately 5% of the monthly averaged nonneutral values.

Esbensen, S. K.↗