Estimation of the Relationship Between Remotely Sensed Anthropogenic Heat Discharge and Building Energy Use

This paper examined the relationship between remotely sensed anthropogenic heat discharge and energy use from residential and commercial buildings across multiple scales in the city of Indianapolis, Indiana, USA. The anthropogenic heat discharge was estimated with a remote sensing-based surface energy balance model, which was parameterized using land cover, land surface temperature, albedo, and meteorological data. The building energy use was estimated using a GIS-based building energy simulation model in conjunction with Department of Energy/Energy Information Administration survey data, the Assessor's parcel data, GIS floor areas data, and remote sensing-derived building height data. The spatial patterns of anthropogenic heat discharge and energy use from residential and commercial buildings were analyzed and compared. Quantitative relationships were evaluated across multiple scales from pixel aggregation to census block. The results indicate that anthropogenic heat discharge is consistent with building energy use in terms of the spatial pattern, and that building energy use accounts for a significant fraction of anthropogenic heat discharge. The research also implies that the relationship between anthropogenic heat discharge and building energy use is scale-dependent. The simultaneous estimation of anthropogenic heat discharge and building energy use via two independent methods improves the understanding of the surface energy balance in an urban landscape. The anthropogenic heat discharge derived from remote sensing and meteorological data may be able to serve as a spatial distribution proxy for spatially-resolved building energy use, and even for fossil-fuel CO2 emissions if additional factors are considered.

Multi-scale↗

Usage of NASA's Near Real-Time Solar and Meteorological Data for Monitoring Building Energy Systems Using RETScreen International's Performance Analysis Module

This paper describes building energy system production and usage monitoring using examples from the new RETScreen Performance Analysis Module, called RETScreen Plus. The module uses daily meteorological (i.e., temperature, humidity, wind and solar, etc.) over a period of time to derive a building system function that is used to monitor building performance. The new module can also be used to target building systems with enhanced technologies. If daily ambient meteorological and solar information are not available, these are obtained over the internet from NASA's near-term data products that provide global meteorological and solar information within 3-6 days of real-time. The accuracy of the NASA data are shown to be excellent for this purpose enabling RETScreen Plus to easily detect changes in the system function and efficiency. This is shown by several examples, one of which is a new building at the NASA Langley Research Center that uses solar panels to provide electrical energy for building energy and excess energy for other uses. The system shows steady performance within the uncertainties of the input data. The other example involves assessing the reduction in energy usage by an apartment building in Sweden before and after an energy efficiency upgrade. In this case, savings up to 16% are shown.

Paul W Stackhouse, Jr.↗

Design of an energy conservation building

The concepts in designing and predicting energy consumption in a low energy use building are summarized. The building will use less than 30,000 Btu/sq.ft./yr. of boarder energy. The building's primary energy conservation features include heavy concrete walls with external insulation, a highly insulated ceiling, and large amounts of glass for natural lighting. A solar collector air system is integrated into the south wall. Calculations for energy conservation features were performed using NASA's NECAP Energy Program.

Jensen, R. N.↗

TPSAS-NF1676L-27534-DND

This presentation describes the preparation, validation and provision of MERRA-2 data products to the building industry for use in energy efficient designs, building codes and monitoring energy efficiency. It highlights efforts to use MERRA-2 surface meteorological data products for the derivation of quantities relevant to the energy and building industry such as heating and cooling degree days and building climate zones on a global basis for the past 30 years. A difference of the zones from the first 15 years and last 30 years shows that warming zones are creeping northward. The talk also presents work provide similar parameters for building energy performance assessment requiring data products closer to real time.

Paul W Stackhouse, Jr↗

Options for demonstrating the use of solar energy in california buildings

Three programmatic options for demonstrating the most economically attractive applications of solar energy to buildings located in California are formulated. The unique characteristics of solar energy demonstration programs and the involvement of key decision makers are discussed in detail. The demonstration programs are related to specific purposes. The priority structure used to select the generic projects making up each program is discussed in relationship to the purposes of the program. In addition, some implications of the nature of the demonstration program for management are outlined.

Davis, E. S.↗

Absorption Of Crushing Energy In Square Composite Tubes

Report describes investigation of crash-energy-absorbing capabilities of square-cross-section tubes of two matrix/fiber composite materials. Both graphite/epoxy and Kevlar/epoxy tubes crushed in progressive and stable manner. Ratio between width of cross section and thickness of wall determined to affect energy-absorption significantly. As ratio decreases, energy-absorption capability increases non-linearly. Useful in building energy-absorbing composite structures.

Farley, Gary L.↗

TPSAS-NF1676L-33912-DND

The agricultural, renewable energy management, and science communities need global surface and top-of-atmosphere (TOA) radiative fluxes on a near real-time basis for uses such as building energy performance monitoring and seasonal crop yield modeling. The Clouds and Earth's Radiant Energy System (CERES) FLASHFlux (Fast Longwave and SHortwave radiative Flux) data products address this need by enhancing the speed of CERES processing using simplified calibration, averaging techniques and fast radiation parameterizations to produce global fluxes within a week of satellite observations. The CERES FLASHFlux provides two data products: 1) an hourly Level 2 Single Scanner Footprint (SSF) data separately for Aqua and Terra observations, and 2) a daily Level 3 Time Interpolated and Spatially Averaged (TISA) 1degree x 1degree gridded data that combines Aqua and Terra observations. The CERES FLASHFlux Version4A includes an update to process MODIS Collection 6.1 in an improved cloud retrieval algorithm, and an update to the CERES Edition 4 angular distribution models. We inter-compared FLASHFlux Version4A, FLASHFlux Version3C, and CERES EBAF (Energy Balanced and Filled) Top-of-Atmosphere fluxes to evaluate these improvements. We also compare both SSF overpass and TISA radiative flux products to a set of surface measurement sites that are globally distributed and assess agreement. FLASHFlux TISA and CERES EBAF are used in the analysis of TOA anomalies for the annual State of Climate report. This also poster highlights the methodology use to merge the two data products by correcting the bias in FLASHFlux TISA and inter-calibrate to CERES EBAF.

Parnchai K Sawaengphokhai↗

Solar heating and cooling of buildings

Solar energy has been used for space heating and water heating for many years. A less common application, although technically feasible, is solar cooling. This paper describes the techniques employed in the heating and cooling of buildings, and in water heating. The potential for solar energy to displace conventional energy sources is discussed. Water heating for new apartments appears to have some features which could make it a place to begin the resurgence of solar energy applications in the United States. A project to investigate apartment solar water heating, currently in the pilot plant construction phase, is described.

Bourke, R. D.↗

An Assessment of Actual and Potential Building Climate Zone Change and Variability From the Last 30 Years Through 2100 Using NASA's MERRA and CMIP5 Simulations

Background: In the US, residential and commercial building infrastructure combined consumes about 40% of total energy usage and emits about 39% of total CO2 emission (DOE/EIA "Annual Energy Outlook 2013"). Building codes, as used by local and state enforcement entities are typically tied to the dominant climate within an enforcement jurisdiction classified according to various climate zones. These climate zones are based upon a 30-year average of local surface observations and are developed by DOE and ASHRAE. Establishing the current variability and potential changes to future building climate zones is very important for increasing the energy efficiency of buildings and reducing energy costs and emissions in the future. Objectives: This paper demonstrates the usefulness of using NASA's Modern Era Retrospective-analysis for Research and Applications (MERRA) atmospheric data assimilation to derive the DOE/ASHRAE building climate zone maps and then using MERRA to define the last 30 years of variability in climate zones for the Continental US. An atmospheric assimilation is a global atmospheric model optimized to satellite, atmospheric and surface in situ measurements. Using MERRA as a baseline, we then evaluate the latest Climate Model Inter-comparison Project (CMIP) climate model Version 5 runs to assess potential variability in future climate zones under various assumptions. Methods: We derive DOE/ASHRAE building climate zones using surface and temperature data products from MERRA. We assess these zones using the uncertainties derived by comparison to surface measurements. Using statistical tests, we evaluate variability of the climate zones in time and assess areas in the continental US for statistically significant trends by region. CMIP 5 produced a data base of over two dozen detailed climate model runs under various greenhouse gas forcing assumptions. We evaluate the variation in building climate zones for 3 different decades using an ensemble and quartile statistics to provide an assessment of potential building climate zone changes relative to the uncertainties demonstrated using MERRA. Findings and Conclusions: These results show that there is a statistically significant increase in the area covered by warmer climate zones and a tendency for a reduction of area in colder climate zones in some limited regions. The CMIP analysis shows that models vary from relatively little building climate zone change for the least sensitive and conservation assumptions to a warming of at most 3 zones for certain areas, particularly the north central US by the end of the 21st century.

Stackhouse, Paul W., Jr.↗

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

Estimating Future Changes of Energy Demand for Heating and Cooling Buildings at NASA Centers GC23J-1198

With its unique and trusted earth observations, NASA is a critical source in informing decisions that will help achieve the U.S. goal of Net-Zero Greenhouse Gas (GHG) Emissions by 2050. NASA’s Prediction of Worldwide Energy Resource (POWER) project facilitates the use of NASA Earth Science data holdings within the energy, agricultural, and building heating/cooling design industries. POWER packages solar and meteorological data from several NASA projects in a user friendly GIS-enabled web services system (https://power.larc.nasa.gov). As part of the development of new data products to support the energy and building heating/cooling design communities, we estimate the changes in energy required to heat and cool buildings in the future climate at 14 different NASA site locations spread throughout the continental United States, as projected by CMIP6 climate models under different emissions scenarios. Bias-corrected downscaled time series of meteorological variables are taken from NASA Earth Exchange (NEX) Global Daily Downscaled Projections (GDDP-CMIP6) downscaled climate model data. The spread between the different model projections is accounted for by analyzing both the ensemble average of 22 CMIP6 models and 6 representative models with different climate sensitivities and different interannual variability. Changes in energy use are estimated in two ways. First, changes in the total annual heating and cooling degree days (HDD and CDD, respectively) are calculated relative to the current climate. This is done at all 14 sites. Second, the downscaled time series are used as inputs into RETScreen(R), a clean energy management decision tool, to give an estimate of heating/cooling energy use for a typical office building. We use this estimation method with model data at Langley Research Center. In the next 50 years, the annual total of HDD (CDD) is projected to decrease by 8-38% (increase by 5-28%) at all sites, with the increase in CDD typically a larger magnitude the decrease in HDD. For a typical small office building at Langley Research Center, the amount of energy needed to cool increases by 33-54% and the amount of energy to heat decreases by 29-40%. POWER is working to develop long term climate data services based on these results to include in future data products to provide to users.

Bradley M. Hegyi↗

Searching for Alien Life Having Unearthly Biochemistry

The search for alien life in the solar system should include exploring unearth-like environments for life having an unearthly biochemistry. We expect alien life to conform to the same basic chemical and ecological constraints as terrestrial life, since inorganic chemistry and the laws of ecosystems appear to be universal. Astrobiologists usually assume alien life will use familiar terrestrial biochemistry and therefore hope to find alien life by searching near water or by supplying hydrocarbons. The assumption that alien life is likely to be based on carbon and water is traditional and plausible. It justifies high priority for missions to search for alien life on Mars and Europa, but it unduly restricts the search for alien life. Terrestrial carbon-water biochemistry is not possible on most of the bodies of our solar system, but all alien life is not necessarily based on terrestrial biochemistry. If alien life has a separate origin from Earth life, and if can survive in an environment extremely different from Earth's, then alien life may have unearthly biochemistry. There may be other solvents than water that support alien life and other elements than carbon that form complex life enabling chain molecules. Rather than making the exploration-restricting assumption that all life requires carbon, water, and terrestrial biochemistry, we should make the exploration-friendly assumption that indigenous, environmentally adapted, alien life forms might flourish using unearthly biochemistry in many places in the solar system. Alien life might be found wherever there is free energy and a physical/chemical system capable of using that energy to build living structures. Alien life may be discovered by the detection of some general non-equilibrium chemistry rather than of terrestrial biochemistry. We should explore all the potential abodes of life in the solar system, including those where life based on terrestrial biochemistry can not exist.

Jones, Harry↗

Strategy for solar heating and cooling in buildings

The types of solar energy heating and cooling equipment for use with buildings are discussed. The steps from manufacturing to equipment installation are identified. A feasibility study for the use of solar energy was conducted. The study determined the technical, environmental, economic, sociological, political, and strategic aspects of solar heating and cooling.

Source record↗

Energy consumption program: A computer model simulating energy loads in buildings

The JPL energy consumption computer program developed as a useful tool in the on-going building modification studies in the DSN energy conservation project is described. The program simulates building heating and cooling loads and computes thermal and electric energy consumption and cost. The accuracy of computations are not sacrificed, however, since the results lie within + or - 10 percent margin compared to those read from energy meters. The program is carefully structured to reduce both user's time and running cost by asking minimum information from the user and reducing many internal time-consuming computational loops. Many unique features were added to handle two-level electronics control rooms not found in any other program.

Stoller, F. W.↗

Experimental solar heating-cooling system model tests of a full-scale building system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable - heating and/or cooling load of a building, collected solar energy - with experimental equipment. The system model was based on the loads and components used in the Solar Building Test Facility (SBTF) which includes a 1394 square meter solar collector field, at NASA-Langley. Operations covered 5 continuous days under summer conditions. For the system model, up to 55% of the simulated collected solar energy was used for the building load. This amount constituted 35% of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, 75% of the collected solar energy would be used. This amount would supply approximately 50% of the building cooling load.

Namkoong, D.↗

The Applications of NASA Mission Technologies to the Greening of Human Impact

I will give an overview talk about flight software systems, robotics technologies and modeling for energy minimization as applied to vehicles and buildings infrastructures. A dominant issue in both design and operations of robotic spacecraft is the minimization of energy use. In the design and building of spacecraft increased power is acquired only at the cost of additional mass and volumes and ultimately cost. Consequently, interplanetary spacecrafts are designed to have the minimum essential power and those designs often incorporate careful timing of all power use. Operationally, the availability of power is the most influential constraint for the use of planetary surface robots, such as the Mars Exploration Rovers. The amount of driving done, the amount of science accomplished and indeed the survivability of the spacecraft itself is determined by the power available for use. For the Mars Exploration Rovers there are four tools which are used: (1) models of the rover and it s thermal and power use (2) predictive environmental models of power input and thermal environment (3) fine grained manipulation of power use (4) optimization modeling and planning tools. In this talk I will discuss possible applications of this methodology to minimizing power use on Earth, especially in buildings.

Sims, Michael H.↗

Tests of a reduced-scale experimental model of a building solar heating-cooling system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable (e.g., heating and cooling load of a building and collected solar energy) with experimental equipment. The experimental system model was based on the loads and components used in the Solar Building Test Facility (SBTF), which includes a 1394 sq m solar collector field at NASA Langley. These tests covered 5 continuous days under summer conditions. For the system model up to 55 percent of the simulated collected solar energy was used for the building load. This amount of solar energy supplied 35 percent of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, which would make it similar to the actual SBTF, 75 percent of the collected solar energy would be used. This amount would supply approximately 50 percent of the building cooling load. A higher fraction of solar energy is possible with a more performance-optimized system.

Namkoong, D.↗