Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Building energy analysis tool

A building energy analysis system includes a building component library configured to store a plurality of building components, a modeling tool configured to access the building component library and create a building model of a building under analysis using building spatial data and using selected building components of the plurality of building components stored in the building component library, a building analysis engine configured to operate the building model and generate a baseline energy model of the building under analysis and further configured to apply one or more energy conservation measures to the baseline energy model in order to generate one or more corresponding optimized energy models, and a recommendation tool configured to assess the one or more optimized energy models against the baseline energy model and generate recommendations for substitute building components or modifications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Automated Translation and Thermal Zoning of Digital Building Models for Energy Analysis

Building energy simulation is valuable during the early stages of design, when decisions can have the greatest impact on energy performance. However, preparing digital design models for building energy simulation typically requires tedious manual alteration. This paper describes a series of five automated steps to translate geometric data from an unzoned CAD model into a multi-zone building energy model. First, CAD input is interpreted as geometric surfaces with materials. Second, surface pairs defining walls of various thicknesses are identified. Third, normal directions of unpaired surfaces are determined. Fourth, space boundaries are defined. Fifth, optionally, settings from previous simulations are applied, and spaces are aggregated into a smaller number of thermal zones. Building energy models created quickly using this method can offer guidance throughout the design process.

97 MATHEMATICS AND COMPUTING↗

Flexible Framework for Building Energy Analysis: Preprint

In the building energy research and advanced practitioner communities, building models are perturbed across large parameter spaces to assess energy and cost performance in the face of programmatic and economic constraints. This paper describes the OpenStudio software framework for performing such analyses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology for Validating Building Energy Analysis Simulations

The objective of this report was to develop a validation methodology for building energy analysis simulations, collect high-quality, unambiguous empirical data for validation, and apply the validation methodology to the DOE-2.1, BLAST-2MRT, BLAST-3.0, DEROB-3, DEROB-4, and SUNCAT 2.4 computer programs. This report covers background information, literature survey, validation methodology, comparative studies, analytical verification, empirical validation, comparative evaluation of codes, and conclusions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Analysis of Manufactured and Multifamily Housing Types in Juneau, Alaska

This report details the results of building energy modeling analysis evaluating the potential energy savings, economic outcomes, and grid-level electricity reduction associated with cold climate air source heat pump (ccASHP) adoption across multifamily and manufactured housing (MMFH) building typologies in the City and Borough of Juneau (CBJ). Three building archetypes were evaluated: multifamily 4-plex apartments, multifamily 8-plex apartments, and manufactured housing units. Building energy models were developed using OpenStudio-HPXML and calibrated to actual utility consumption data and local meteorological data from the Juneau International Airport weather station using an automated calibration tool following the BPI-2400-S-2015 v.2 standard for model calibration. Occupant behaviors present the greatest variability in successful calibrations. Calibrated models were benchmarked against a baseline electric resistance heating condition, with the selected ccASHP modeled as the retrofit condition and typical meteorological year weather data for all results generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Minimizing User Burden in Building Energy Analysis

Infrared (IR) imagery can provide valuable data to building energy auditors and the developers of Building Energy Models (BEM). IR by itself is not a panacea to the challenges facing energy auditors and modelers, but when combined with other techniques and Open Studio software, IR can play an important role in the minimization of the burden of creating building energy models and the diagnosing of building energy problems. While IR can be used to detect and quantify many aspects of a building’s thermal and energy performance, in Phase I we focused on a single capability: determining the R value of exterior walls. Two key attributes of using IR methods for R value determination is that IR methods measure the actual, installed performance in-situ – as opposed to relying on manufacturer or handbook values – and they can integrate performance over a wide area and thus can accurately account for thermal bridging and spatial anomalies such as “spotty” insulation installation. There is a trade between user burden and accuracy when using IR to determine a wall’s R value. The least burdensome approach is computing R values from a single IR snapshot. The most burdensome method we considered was to combine IR images with thermocouple and heat flux sensor (HFS) measurements made over the course of several days. The more effort users expend in making the measurements, the more accurate and robust the method becomes. Through a series of field tests at the ThermoAnalytics Inc. (TAI) HQ at Calumet, MI and a simulation of a 1980s era office building in Flagstaff, AZ we investigated methods to compute the R value of exterior walls using data from IR cameras, thermocouples and heat flux sensors. To compute R values the heat flux through the wall, along with temperatures on either side of the wall, must be known, modeled, or estimated – and the temperature difference through the wall should be at least 10 C. If only outdoor IR images are used in the method, the inside ambient air temperature must be estimated, and a simulation model created to predict heat fluxes and the indoor wall temperature. The accuracy of the resulting R value depends on the accuracy of the simulation and the assumptions it employs. Applying thermocouple sensors, either as iButtons or as part of a wireless sensor network, to the walls allows for the acquisition of temperatures over time. The longer the duration of the measurements, the more accurate and robust the method will be. Even with this level of measurement effort, modeling is still required to calculate the heat flux through the wall. The addition of a heat flux sensor alleviates the need for any modeling, and that results in improved accuracy. Driving the accuracy of the methods are several factors that can be quantified. How well are the wall surface temperatures known? Modeling the heat flux through walls requires knowing the details of the surrounding radiant environment and the heat transfer due to convection. How well are these boundary conditions known? Even when the heat flux is measured, error can arise when some of the measured heat is not conducted through the wall but rather goes into the thermal mass of the wall. Thermal mass effects occur when conditions and the heat flux values are fluctuating. A technique that is not robust will suffer in accuracy when these fluctuations occur. The R value determination method must be incorporated into the Open Studio process. In our proposed process, IR images and other measured sensor data are input into a module that would send R value estimates to a building library developed by team member Skidmore, Owings, & Merrill (SOM). This library of parameterized building models would use these R values along with information about the building’s age, type, and location to query the Open Studio BCL to identify the most likely constructions for walls, roof, and windows. Being based on the IMF feature of Energyplus, the SOM building library can quickly produce Energyplus models of buildings based on a limited number of user inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Infiltration modeling guidelines for commercial building energy analysis

This report presents a methodology for modeling air infiltration in EnergyPlus to account for envelope air barrier characteristics. Based on a review of various infiltration modeling options available in EnergyPlus and sensitivity analysis, the linear wind velocity coefficient based on DOE-2 infiltration model is recommended. The methodology described in this report can be used to calculate the EnergyPlus infiltration input for any given building level infiltration rate specified at known pressure difference. The sensitivity analysis shows that EnergyPlus calculates the wind speed based on zone altitude, and the linear wind velocity coefficient represents the variation in infiltration heat loss consistent with building location and weather data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scripted Building Energy Modeling and Analysis (Presentation)

Building energy analysis is often time-intensive, error-prone, and non-reproducible. Entire energy analyses can be scripted end-to-end using the OpenStudio Ruby API. Common tasks within an analysis can be automated using OpenStudio Measures. Graphical user interfaces (GUI's) and component libraries reduce time, decrease errors, and improve repeatability in energy modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scripted Building Energy Modeling and Analysis: Preprint

Building energy modeling and analysis is currently a time-intensive, error-prone, and nonreproducible process. This paper describes the scripting platform of the OpenStudio tool suite (http://openstudio.nrel.gov) and demonstrates its use in several contexts. Two classes of scripts are described and demonstrated: measures and free-form scripts. Measures are small, single-purpose scripts thatconform to a predefined interface. Because measures are fairly simple, they can be written or modified by inexperienced programmers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of time-frequency-analysis techniques applied in building energy data noise cancellation for building load forecasting: A real-building case study

Time-frequency analysis that disaggregates a signal in both time and frequency domain is an important supporting technique for building energy analysis such as noise cancellation in data-driven building load forecasting. There is a gap in the literature related to comparing various time–frequency-analysis techniques, especially discrete wavelet transform (DWT) and empirical mode decomposition (EMD), to guide the selection and tuning of time–frequency-analysis techniques in data-driven building load forecasting. This article provides a framework to conduct a comprehensive comparison among thirteen DWT/EMD techniques with various parameters in a load forecasting modeling task. A real campus building is used as a case study for illustration. The DWT and EMD techniques are also compared under various data-driven modeling algorithms for building load forecasting. The results in the case study show that the load forecasting models trained with noise-cancelled energy data have increased their accuracy to 9.6% on average tested under unseen data. This study also shows that the effectiveness of DWT/EMD techniques depends on the data-driven algorithms used for load forecasting modeling and the training data. Hence, DWT/EMD-based noise cancellation needs customized selection and tuning to optimize their performance for data-driven building load forecasting modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

EnergyPlus Analysis Capabilities for Use in California Building Energy Efficiency Standards Development and Compliance Calculations

California has been using DOE-2 as the main building energy analysis tool in the development of building energy efficiency standards (Title 24) and the code compliance calculations. However, DOE-2.1E is a mature program that is no longer supported by LBNL on contract to the USDOE, or by any other public or private entity. With no more significant updates in the modeling capabilities of DOE-2.1E during recent years, DOE-2.1E lacks the ability to model, with the necessary accuracy, a number of building technologies that have the potential to reduce significantly the energy consumption of buildings in California. DOE-2's legacy software code makes it difficult and time consuming to add new or enhance existing modeling features in DOE-2. Therefore the USDOE proposed to develop a new tool, EnergyPlus, which is intended to replace DOE-2 as the next generation building simulation tool. EnergyPlus inherited most of the useful features from DOE-2 and BLAST, and more significantly added new modeling capabilities far beyond DOE-2, BLAST, and other simulations tools currently available. With California's net zero energy goals for new residential buildings in 2020 and for new commercial buildings in 2030, California needs to evaluate and promote currently available best practice and emerging technologies to significantly reduce energy use of buildings for space cooling and heating, ventilating, refrigerating, lighting, and water heating. The California Energy Commission (CEC) needs to adopt a new building energy simulation program for developing and maintaining future versions of Title 24. Therefore, EnergyPlus became a good candidate to CEC for its use in developing and complying with future Title 24 upgrades. In 2004, the Pacific Gas and Electric Company contracted with ArchitecturalEnergy Corporation (AEC), Taylor Engineering, and GARD Analytics to evaluate EnergyPlus in its ability to model those energy efficiency measures specified in both the residential and nonresidential Alternative Calculation Method (ACM) of the Title-24 Standards. The AEC team identified gaps between EnergyPlus modeling capabilities and the requirements of Title 24 and ACMs. AEC's evaluation was based on the 2005 version of Title 24 and ACMs and the version 1.2.1 of EnergyPlus released on October 1, 2004. AEC's evaluation is useful for understanding the functionality and technical merits of EnergyPlus for implementing the performance-based compliance methods described in the ACMs. However, it did not study the performance of EnergyPlus in actually making building energy simulations for both the standard and proposed building designs, as is required for any software program to be certified by the CEC for use in doing Title-24 compliance calculations. In 2005, CEC funded LBNL to evaluate the use of EnergyPlus for compliance calculations by comparing the ACM accuracy test runs between DOE-2.1E and EnergyPlus. LBNL team identified key technical issues that must be addressed before EnergyPlus can be considered by the CEC for use in developing future Nonresidential Title-24 Standards or as an ACM tool. With Title 24 being updated to the 2008 version (which adds new requirements to the standards and ACMs), and EnergyPlus having been through several update cycles from version 1.2.1 to 2.1, it becomes crucial to review and update the previously identified gaps of EnergyPlus for use in Title 24, and more importantly to close the gaps which would help pave the way for EnergyPlus to be adopted as a Title 24 compliance ACM. With this as the key driving force, CEC funded LBNL in 2008 through this PIER (Public Interest Energy Research) project with the overall technical goal to expand development of EnergyPlus to provide for its use in Title-24 standard compliance and by CEC staff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BETTER Together

The Standard Energy Efficiency Data (SEED) and Building Efficiency Targeting Tool for Energy Retrofits (BETTER) platforms are both developed by the Department of Energy and work better together. SEED is a database to manage building characteristics and performance data from a variety of sources. BETTER provides simple energy efficiency measure analyses based on high level data about the building or portfolio of buildings. A demonstration of each platform and their integration will be provided. The inputs for BETTER are building type, floor area, location, utility data, and whether PV shall be included in the analysis. The BETTER analysis can be manually set up through the web application or data can be uploaded with a BuildingSync XML file either directly or through the API. SEED can be the source of this data and the data can be sent to BETTER through the SEED application after the BETTER API token has been entered. The benefit of utilizing SEED is that it has connections to many other sources of data such as ENERGY STAR Portfolio Manager, Audit Template, and Salesforce. Therefore, it is likely that a user of SEED will already have the required inputs for BETTER in SEED already and can create BETTER analyses across their whole portfolio in a couple mouse clicks. This is a major time savings and enables decision makers an easy path to identify buildings that should undergo more detailed audits or retrofit pathways.

ASHRAE↗