Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building efficiency incentives”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Convincing Clients to Make Zero a Reality: Preprint

As buildings are the largest end-users of carbon-intensive energy in the United States, it is critical that design and construction professionals implement energy-efficient and sustainable building designs and systems. Building owners seeking building energy performance improvements, either with new construction or retrofit of existing facilities, usually need the expertise of design and construction professionals to guide them through the process. These "trusted advisers" make the design decisions that ultimately result in the energy performance of the building. Members of the design and construction community have identified that clients' perception of cost associated with such designs and building upgrades have posed the most significant barrier to increased adoption. If solved, this would enable design and construction firms to better engage as trusted advisors along the lines of energy and carbon reduction of the built environment. NREL has developed a resource that helps design and construction professionals and their clients match their projects with financial incentives. A newly developed cohort of design and construction professionals, as part of the U.S. Department of Energy's Better Buildings Initiative, has brought real-world project experiences to the development process, contributing meaningful insights that have been critical to evaluating the successes of and providing direction to this much needed financial guide.

Better Buildings↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-technology building system retrofits for utility incentive programs: Savings, costs and baseline considerations

Utility incentive programs are an important channel to support the deployment of energy efficiency in buildings. To date, these programs have largely been limited to single-component strategies. However, many utilities are now motivated to identify and develop multi-component system retrofits to achieve deeper energy savings, which are essential to achieving broader energy and greenhouse gas reduction goals in the buildings sector. In this paper we present the energy savings, demand reductions, and cost-effectiveness of 16 systems retrofit packages in six utility regions in the United States. These results are being used by these utilities to inform and develop incentive programs for systems retrofits. Our analysis shows that packages with proven lighting and HVAC measures can provide 5–22% whole building annual energy savings, and 13–22% annual energy costs savings, using utility incentive program baselines (code and existing building). The packages are reasonably cost effective for replace-on-burnout but generally not for a retrofit scenario prior to end of equipment life. Demand response can increase both the energy savings and energy cost savings, further improving the cost effectiveness of these packages. We analyzed the impact of using existing building vs. code baselines for calculating savings, showing that the choice of baseline in developing utility incentive programs has a substantial impact on the attributable energy savings to a program, with significant implications for the overall viability of a program (generally savings against existing building condition are higher and improve project and program cost-effectiveness).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Survey of Direct Heating Equipment Market Actors in California

Direct Heating Equipment (DHE) is a category of ductless space heating appliances that provide warm air directly to the space where they are installed. We investigate, from the perspective of the DHE supply chain in California, what types of DHE are marketed in the state, how they are sold and serviced, and whether any potential barriers to adoption of high-efficiency DHE exist. We find that the market for DHE in the state is almost exclusively a replacement market, with some additional repair and maintenance services. We also find that, even though manufacturers sell high-efficiency DHE models in California, most contractors report installing baseline models most of the time. Contractors say their customers do not see any value in high-efficiency units, and they (contractors) do not believe that high-efficiency DHE is worth the additional cost to their customers. In addition, the majority of contractors purchase DHE from distributors and, therefore, distributors are a key piece of the supply chain that can constrain DHE purchase choice. Distributors do not see a demand for high-efficiency DHE and, hence, do not keep stock of these units. They argue that, since the market is driven mostly by replacements and these replacements occur typically in an unplanned way, homeowners are unwilling to pay for any additional costs associated with a high-efficiency model. Rather, homeowners usually prefer to replace the failed unit with a new unit that can fit in the same location with no- or minimal additional replacement costs. Considering that most DHE purchases are made by contractors, on behalf of their customers, informing contractors (and homeowners) of the potential cost-effectiveness of efficient DHE could help mitigate some of the barriers to the adoption of high-efficiency DHE in the state. In addition, monetary incentives and more stringent building codes that apply to DHE replacements can contribute to increasing adoption of high-efficiency DHE in California. This will not only reduce energy costs, but also increase safety and comfort to DHE users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Tune-Up Accelerator Program (Final Technical Report)

In 2016, the City of Seattle passed a mandatory Building Tune-Up requirement for all commercial buildings 50,000 square feet (SF) and larger as part of its Climate Action strategy. The requirement is phased in by size with large buildings (greater than 200,000 SF) required first. This allowed Seattle’s Office of Sustainability & Environment (OSE) to offer the Building Tune-Up Accelerator (TUA) Program to the “mid-size” building market (less than 100,000 SF) to meet the requirements early. With funding from the US DOE, a package of technical and financial support was developed for building owners and energy service providers to encourage this hard-to-reach market to participate in the tune-up—and even go beyond requirements for greater energy savings. Seattle City Light, the municipal electric utility, offered participants a simple per square foot financial incentive. Partners at the University of Washington Integrated Design Lab, Smart Buildings Center and Pacific Northwest National Lab (PNNL) offered service provider trainings, analytical tools and technical support. This final technical report summarizes the program, projected energy and emissions savings and lessons learned from program development to implementation to final evaluation for the 102 buildings that participated.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Simplified Building Modeling Approach for Identifying Whole Building Retrofits

Building Energy Modeling (BEM) is an effective strategy for optimizing new and retrofit building design, evaluating its energy savings potential and rating its energy performance. However, because of the complexity and expense of modeling, only a small percentage of buildings are simulated. Over 80% of buildings are <25,000 ft2, and the cost associated with BEM can be a big deterrent for reaching this subsector, which usually ends up complying with energy codes and qualifying for incentives using prescriptive measures or generalized design guides. Similarly, efficiency considerations for small building retrofits are often identified through deemed measures or Technical Reference Manuals, which though a scalable and convenient approach, can limit innovation in design and optimization of measures. Simplification of the modeling process, where appropriate, can lead to increased energy savings and more informed decision making. This paper will discuss the development of a ruleset for a simplified approach based on the Performance Rating Method (PRM) contained in ASHRAE Standard 90.1. The approach aims to simplify and lower the cost of the energy modeling process in a controlled and documented manner. An anticipated outcome is an increased use of BEM and its effectiveness in the design, retrofit and operation of commercial buildings. In addition, simplification of the modeling process will result in fewer errors from misinterpretations of both program requirements and program intent in simulation software. The paper will discuss the need and advantages of a simplified modeling approach for whole building retrofits and the technical process for achieving the same.

Goel, Supriya↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization Considerations: Grid-Interactive Efficient Buildings [Slides]

The Federal Energy Management Program (FEMP) is helping federal agencies understand how to meet decarbonization goals with grid interactive efficient buildings (GEB). This training will provide attendees with an introduction to GEB, how to work with utilities, and opportunities for federal sites.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

Lighting Technology Energy Solutions (LiTES) (Final Technical Report)

The Lighting Technologies Energy Solutions (LiTES) Program Final Technical Report is a collaborative effort between NextEnergy, Consumers Energy, DTE Energy (DTE) and the Detroit Joint Apprentice Training Center (DJATC) to evaluate customer and contractor experiences deploying advanced/networked lighting controls systems (ALC/NLC). The LiTES Program, funded by the US Department of Energy (DOE), sought to reduce energy use in small and medium commercial buildings (SMCB) by accelerating the adoption of ALC/NLC through contractor training and technology deployment. Leveraging recommendations already outlined by the Design Lights Consortium Commercial Advanced Lighting Controls (DLC CALC) project, NextEnergy led an effort to train contractors, evaluate the experience of ALC/NLC demonstration projects, identify opportunities to reduce market barriers, and accelerate the increased adoption of ALC/NLC technologies within SMCB. The LiTES Program defined SMCB as commercial buildings under 100,000 square feet. The LiTES Program efforts also included evaluating current ALC/NLC utility incentives, piloting ALC/NLC incentives specific to SMCB, and identifying opportunities to better align utility incentives with current ALC/NLC technology to support accelerating the adoption of ALC/NLC in SMCB. This report shares the survey results and M&V data findings, including energy savings, market barriers, experience of installations, impact of incentives/financing programs and provides recommendations for the increased deployment of ALC/NLC systems in small and medium commercial buildings. Utility survey results, incentive alternatives and recommendations, including a cost benefit analysis outlining energy and economic impacts of the provided ALC/NLC incentives on SMCB projects are also provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency and Renewable Energy for New Home Construction in Maui

For residential property owners preparing to rebuild homes in Maui, this fact sheet, produced by the National Renewable Energy Laboratory (NREL), a national laboratory of the U.S. Department of Energy (DOE), provides a brief introduction to the topics of renewable energy and energy efficiency for new residential construction, presents a few high-level considerations and key concepts, and provides a sampling of information on rebates, incentives, certification programs, standards, and relevant policies. This fact sheet is not intended to be comprehensive nor to replace local resources.

appliances↗

Review of the U.S. Policies, Codes, and Standards of Zero-Carbon Buildings

The global issue of climate change has accelerated the international commitment to net-zero carbon emission development. Decarbonizing the building sector has been put on several governments’ sustainable development agendas. To provide a reference for decarbonizing the building sector, this paper summarizes the U.S. experience in zero-carbon buildings (ZCBs) from the aspects of policies, codes, and standards at the federal and local levels and those of professional societies. Based on the definition and boundaries of ZCBs, this paper introduces policies on building energy efficiency, electrification, on-site renewable energy deployment, and “buy clean”, illustrating highlights in building phases, energy systems, materials production, and fiscal incentives. The synergic efforts and coordination between federal and local levels and with professional societies are also introduced. Successful experiences in policy and standard implementation are summarized, including the systemic work of multilevel governance, clearly defined goals and stringent policies, constant upgrades of codes and standards, transparency in reporting and information sharing, and increased financial and investment opportunities. This paper provides concrete recommendations for developing zero-carbon building policies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficiency and Demand Flexibility in Large Office Buildings: The Potential for Cost Savings and CO 2 Reductions from Lighting and Cooling Measures

This report presents the estimated impact of lighting and cooling efficiency and demand flexibility measures in large office buildings in each state in the contiguous United States. It provides modeled results for three different metrics: bill savings, regional grid operational costs savings, and carbon dioxide (CO 2 ) emissions reductions. Lighting efficiency and demand flexibility are estimated to reduce load by up to 80 MWh/yr in a single large office building. These load reductions result in customer bill savings of up to $8,800/yr per building, with the highest savings in southern and midwestern states. Grid operating cost savings are estimated at up to $3,240/yr/building, with greatest benefit in southern and northeastern states. CO 2 emissions reduction potential is highest in the Dakotas, Nebraska, across the Midwest, in West Virginia, and in Mississippi (<48,200 kg/yr/building). Comparatively, cooling measures are found to have less load reduction potential (<28.5 MWh/yr/building), with the greatest potential in southern states including Texas, which ranks top of the list across several of the metrics studied. In numerous states, shifting cooling load to off-peak hours is found to increase costs and CO 2 emissions because precooling results in increased load during high-cost or high-CO 2 emissions periods. In general, focusing on cooling efficiency and load shedding has the potential for more savings. In all cases, the specific rate structure is a significant determinant in actual bill savings, which are up to $4,000/yr/building. To realize the full potential for bill savings through an energy measure, building operators must identify how the measure will change the building load pattern and the interaction of this load change with the applicable rate tariff. To realize CO 2 emissions reductions, industry and state coordination is needed to verify which fuel source is on the margin and then to create incentives for end users to reduce load during high-CO 2 emissions hours. Regular updates to data sets and analyses are critical. Regulators and policymakers are well positioned to facilitate the necessary coordination between the electric industry and building energy managers to develop appropriate price signals and incentives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A High-Granularity Approach to Modeling Energy Consumption and Savings Potential in the U.S. Residential Building Stock: Preprint

Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper will describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.

building stock↗

Is the Adoption of Electric Vehicles (EVs) and Solar Photovoltaics (PVs) Interdependent or Independent? An Integrated EVs-PVs Modeling Framework

Transportation and residential energy consumption account for more than one-half of the overall energy consumption in the United States. Adoption of electric vehicles (EVs) can play a key role in decarbonizing the transportation sector, while the adoption of renewable energy sources (e.g., solar photovoltaics or PVs) could bring similar benefits to the residential energy sector and in turn support transport electrification. Although the market share for both EVs and PVs continue to grow, both these emerging technologies are deployed rather disjoint without considering the existence of potential similarities among users who own (or aspire to own) EVs and PVs. This might be due to lack of understanding of the behavioral interdependence in consumer preferences towards these technologies. To fill this gap in knowledge, this study utilizes data from the 2018 WholeTraveler Transportation Behavior Study to develop an integrated model system that explores EV and PV adoption behaviors. A structural equations model (SEM) is employed that incorporates direct effects as well as error correlations among the adoption behaviors for EVs and PVs. Model results indicate that the adoption behavior for both these technologies is indeed interconnected and significantly influenced by attitudes, values and personality traits. Findings from this research suggest that incentives (e.g., subsidies) that drive 'bundled' adoption of EVs and PVs could accelerate the adoption of both these sustainable technologies. The results highlights the need to consider transport and building energy efficient technology adoption behavior in a single integrated structure.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

The electric vehicles-solar photovoltaics Nexus: Driving cross-sectoral adoption of sustainable technologies

Residential and transportation energy consumption account for more than one-half of the overall energy consumption in the United States. Adoption of electric vehicles (EVs) can play a key role in decarbonizing the transportation sector, while the adoption of renewable energy sources (e.g., solar photovoltaics [PVs]) could bring similar benefits to the residential energy sector and in turn support transport electrification. Although the market shares for both EVs and PVs continue to grow, both of these emerging technologies are deployed rather disjointly, without considering the existence of potential similarities among users who own (or aspire to own) these technologies. This might be due to lack of understanding of the behavioral interdependence in consumer preferences toward these technologies. To fill this gap in knowledge, this study utilizes data from the 2018 WholeTraveler Transportation Behavior Study to develop an integrated model system that explores interactive EV and PV adoption behaviors. A structural equation model is employed that incorporates direct effects as well as error correlations among the adoption behaviors for EVs and PVs. Model results indicate that the adoption behavior for both these technologies is indeed interconnected and significantly influenced by attitudes, values, and personality traits. Findings from this research suggest that incentives (e.g., subsidies) that drive bundled adoption of EV-PV systems could accelerate the adoption of both of these sustainable technologies. In conclusion, this study highlights the need to consider transport and building energy-efficient technology adoption behavior in a single integrated structure.

14 SOLAR ENERGY↗

Heat pumps for all? Distributions of the costs and benefits of residential air-source heat pumps in the United States

Electrification of fossil-fuel combustion in buildings is a key component of achieving global greenhouse gas emissions targets. We use physics simulations of 550,000 statistically representative households to analyze distributions of the costs and benefits of three air-to-air heat pump performance levels, with and without insulation upgrades, across the diversity of the US housing stock. We find positive greenhouse gas reductions in every US state for all performance levels across five 2022-2038 electric grid scenarios, with full adoption reducing national emissions by 5%-9%. We find that air-to-air heat pumps could be cost effective without subsidies in 59% of households (65 million). However, efficiency is key: whereas minimum-efficiency equipment could increase energy bills in 39% of households, this fraction is only 19% when also upgrading insulation or 5% when using higher-efficiency equipment, though both strategies have higher upfront costs. Such affordability challenges could be addressed through supportive incentives, policy, and innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Paths Forward: Approaches to Achieve Plug and Process Load Efficiency and Control in Commercial Buildings: Preprint

To accomplish net-zero carbon in the built environment by 2050, we must equitably decarbonize commercial buildings, which includes reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not directly associated with major building end uses like lighting and heating, ventilating, and air conditioning. PPLs account for a growing portion of U.S. commercial building energy consumption. Although commercial building PPL strategies and technologies are available today, they have not been adopted at a level sufficient to achieve significant savings and load flexibility across the building stock. In our "Pathways to Plug and Process Load Efficiency and Control" study, we investigated why these technologies and strategies have not seen widespread adoption and identified five behavior and technology pathways to increase PPL reduction in commercial buildings. In this paper, we expand beyond identifying the pathways and discuss approaches for achieving them. We discuss the importance of collecting and sharing data and case studies on PPL energy consumption and savings from control technology implementation, including code-required measures, for increasing adoption. Centralizing case studies and data, engaging industry organizations, and promoting awareness of PPL efficiency benefits to relevant groups are also key approaches. Additionally, funding, incentives, and rebate programs play important roles in driving PPL efficiency and control adoption. Finally, we discuss integrating PPL efficiency into broader company goals, such as environmental, social and governance (ESG) strategies and green building certifications, to further drive adoption.

adoption pathways↗