Experimental solar heating-cooling system model tests of a full-scale building system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable - heating and/or cooling load of a building, collected solar energy - with experimental equipment. The system model was based on the loads and components used in the Solar Building Test Facility (SBTF) which includes a 1394 square meter solar collector field, at NASA-Langley. Operations covered 5 continuous days under summer conditions. For the system model, up to 55% of the simulated collected solar energy was used for the building load. This amount constituted 35% of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, 75% of the collected solar energy would be used. This amount would supply approximately 50% of the building cooling load.

Namkoong, D.↗

Tests of a reduced-scale experimental model of a building solar heating-cooling system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable (e.g., heating and cooling load of a building and collected solar energy) with experimental equipment. The experimental system model was based on the loads and components used in the Solar Building Test Facility (SBTF), which includes a 1394 sq m solar collector field at NASA Langley. These tests covered 5 continuous days under summer conditions. For the system model up to 55 percent of the simulated collected solar energy was used for the building load. This amount of solar energy supplied 35 percent of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, which would make it similar to the actual SBTF, 75 percent of the collected solar energy would be used. This amount would supply approximately 50 percent of the building cooling load. A higher fraction of solar energy is possible with a more performance-optimized system.

Namkoong, D.↗

The updated algorithm of the Energy Consumption Program (ECP): A computer model simulating heating and cooling energy loads in buildings

The energy Comsumption Computer Program was developed to simulate building heating and cooling loads and compute thermal and electric energy consumption and cost. This article reports on the new additional algorithms and modifications made in an effort to widen the areas of application. The program structure was rewritten accordingly to refine and advance the building model and to further reduce the processing time and cost. The program is noted for its very low cost and ease of use compared to other available codes. The accuracy of computations is not sacrificed however, since the results are expected to lie within + or - 10% of actual energy meter readings.

Lansing, F. L.↗

JPL Energy Consumption Program (ECP) documentation: A computer model simulating heating, cooling and energy loads in buildings

The engineering manual provides a complete companion documentation about the structure of the main program and subroutines, the preparation of input data, the interpretation of output results, access and use of the program, and the detailed description of all the analytic, logical expressions and flow charts used in computations and program structure. A numerical example is provided and solved completely to show the sequence of computations followed. The program is carefully structured to reduce both user's time and costs without sacrificing accuracy. The user would expect a cost of CPU time of approximately $5.00 per building zone excluding printing costs. The accuracy, on the other hand, measured by deviation of simulated consumption from watt-hour meter readings, was found by many simulation tests not to exceed + or - 10 percent margin.

Lansing, F. L.↗

Energy consumption program: A computer model simulating energy loads in buildings

The JPL energy consumption computer program developed as a useful tool in the on-going building modification studies in the DSN energy conservation project is described. The program simulates building heating and cooling loads and computes thermal and electric energy consumption and cost. The accuracy of computations are not sacrificed, however, since the results lie within + or - 10 percent margin compared to those read from energy meters. The program is carefully structured to reduce both user's time and running cost by asking minimum information from the user and reducing many internal time-consuming computational loops. Many unique features were added to handle two-level electronics control rooms not found in any other program.

Stoller, F. W.↗

A sensitivity model for energy consumption in buildings. Part 1: Effect of exterior environment

A simple analytical model is developed for the simulation of seasonal heating and cooling loads of any class of buildings to complement available computerized techniques which make hourly, daily, and monthly calculations. An expression for the annual energy utilization index, which is a common measure of rating buildings having the same functional utilization, is derived to include about 30 parameters for both building interior and exterior environments. The sensitivity of a general class building to either controlled or uncontrolled weather parameters is examined. A hypothetical office type building, located at the Goldstone Space Communication Complex, Goldstone, California, is selected as an example for the numerical sensitivity evaluations. Several expressions of variations in local outside air temperature, pressure, solar radiation, and wind velocity are presented.

Lansing, F. L.↗

SESOP: Program for solar-energy heating-systems analysis

Space heating and cooling loads are calculated for each building based on outside environment, desired inside conditions, building construction and geometry, domestic power usage, occupancy rate, and occupant metabolic rate. Loads are summed to determine requirements of central and alternative utility systems.

Source record↗

Site dependent factors affecting the economic feasibility of solar powered absorption cooling

A procedure was developed to evaluate the cost effectiveness of combining an absorption cycle chiller with a solar energy system. A basic assumption of the procedure is that a solar energy system exists for meeting the heating load of the building, and that the building must be cooled. The decision to be made is to either cool the building with a conventional vapor compression cycle chiller or to use the existing solar energy system to provide a heat input to the absorption chiller. Two methods of meeting the cooling load not supplied by solar energy were considered. In the first method, heat is supplied to the absorption chiller by a boiler using fossil fuel. In the second method, the load not met by solar energy is net by a conventional vapor compression chiller. In addition, the procedure can consider waste heat as another form of auxiliary energy. Commercial applications of solar cooling with an absorption chiller were found to be more cost effective than the residential applications. In general, it was found that the larger the chiller, the more economically feasible it would be. Also, it was found that a conventional vapor compression chiller is a viable alternative for the auxiliary cooling source, especially for the larger chillers. The results of the analysis gives a relative rating of the sites considered as to their economic feasibility of solar cooling.

Bartlett, J. C.↗

Solar-heated and cooled savings and loan building-1-Leavenworth, Kanasas

Report describes heating and cooling system which furnishes 90 percent of annual heating load, 70 percent of cooling load, and all hot water for two-story building. Roof-mounted flat-plate collectors allow three distinct flow rates and are oriented south for optimum energy collection. Building contains fully automated temperature controls is divided into five temperature-load zones, each with independent heat pump.

Source record↗

Solar-Energy System for a Commercial Building--Topeka, Kansas

Report describes a solar-energy system for space heating, cooling and domestic hot water at a 5,600 square-foot (520-square-meter) Topeka, Kansas, commercial building. System is expected to provide 74% of annual cooling load, 47% of heating load, and 95% of domestic hot-water load. System was included in building design to maximize energy conservation.

Source record↗

Solar thermal heating and cooling. A bibliography with abstracts

This bibliographic series cites and abstracts the literature and technical papers on the heating and cooling of buildings with solar thermal energy. Over 650 citations are arranged in the following categories: space heating and cooling systems; space heating and cooling models; building energy conservation; architectural considerations, thermal load computations; thermal load measurements, domestic hot water, solar and atmospheric radiation, swimming pools; and economics.

Arenson, M.↗

Solar heating and cooling system installed at Leavenworth, Kansas

A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

Source record↗

Continuous Cooling from 10 K to 4 K Using a Toroidal ADR

Future large infrared space telescopes will require cooling to 4K to achieve background limited performance for submillimeter wavelengths. These observatories will require lifetimes of many years and will have relatively large cooling requirements making stored helium dewars impractical. We have designed and are building an adiabatic demagnetization refrigerator (ADR) for use in cooling relatively large loads (10- 100 mW) at 4K and rejecting that heat to a cryocooler operating at 1 OK. Cryocoolers below 1 OK have poor thermodynamic efficiency and ADRs can operate in this temperature range with an efficiency of 75% of Carnot or better. Overall, this can save as much as 2/3 of the input power required to operate a 4K cryocooler. The ADR magnet consists of 8 short coils wired in series and arranged in a toroid to provide self shielding of its magnetic field. This will save mass (about 30% of the mass or about 1.5 kg in our small version, higher percentages in higher cooling power, larger versions) that would have been used for passive or active shields in an ordinary solenoid. The toroid has a 100 mm outer diameter and will produce an approximately 3T average field. In the initial demonstration model the toroid coils will be wound with ordinary NbTi wire and operated at 4K. A second version will then use Nb3Sn wire to provide complete 10K operation. As a refrigerant for this temperature range we will use either GdLiF4 or GdF3 crystals, pending tests of these crystals' cooling capacity per field and thermal conductance. Preliminary indications are that these materials are superior to GGG. We will use gas gap heat switches to alternately connect the toroid to the cold load and the warm heat sink. A small continuous stage will maintain the cold end at 4K while the main toroid is recycled.

DiPirro, Michael J.↗

Subcontracted activities related to TES for building heating and cooling

The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.

Martin, J.↗

A flight-rated liquid-cooled garment for use within a full-pressure suit

A flight rated liquid cooled garment system for use inside a full pressure suit has been designed, fabricated, and tested. High temperature tests with this system have indicated that heat is absorbed at a rate decreasing from 224 kg-cal/hr to 143 kg-cal/hr over a 40-min period. The first 30 min are very comfortable; thereafter a gradual heat load builds that results in mild sweating at the end of the 40-min period. In flight tests during hot weather when this cooling system was worn under a regulation flight suit, the pilot reported that temperatures were comfortable and that the garment prevented sweating.

Carpenter, R.↗

Building heating and cooling applications thermal energy storage program overview

Thermal energy storage technology and development of building heating and cooling applications in the residential and commercial sectors is outlined. Three elements are identified to undergo an applications assessment, technology development, and demonstration. Emphasis is given to utility load management thermal energy system application where the stress is on the 'customer side of the meter'. Thermal storage subsystems for space conditioning and conservation means of increased thermal mass within the building envelope and by means of low-grade waste heat recovery are covered.

Eissenberg, D. M.↗

Rapid Prototyping Integrated With Nondestructive Evaluation and Finite Element Analysis

Most reverse engineering approaches involve imaging or digitizing an object then creating a computerized reconstruction that can be integrated, in three dimensions, into a particular design environment. Rapid prototyping (RP) refers to the practical ability to build high-quality physical prototypes directly from computer aided design (CAD) files. Using rapid prototyping, full-scale models or patterns can be built using a variety of materials in a fraction of the time required by more traditional prototyping techniques (refs. 1 and 2). Many software packages have been developed and are being designed to tackle the reverse engineering and rapid prototyping issues just mentioned. For example, image processing and three-dimensional reconstruction visualization software such as Velocity2 (ref. 3) are being used to carry out the construction process of three-dimensional volume models and the subsequent generation of a stereolithography file that is suitable for CAD applications. Producing three-dimensional models of objects from computed tomography (CT) scans is becoming a valuable nondestructive evaluation methodology (ref. 4). Real components can be rendered and subjected to temperature and stress tests using structural engineering software codes. For this to be achieved, accurate high-resolution images have to be obtained via CT scans and then processed, converted into a traditional file format, and translated into finite element models. Prototyping a three-dimensional volume of a composite structure by reading in a series of two-dimensional images generated via CT and by using and integrating commercial software (e.g. Velocity2, MSC/PATRAN (ref. 5), and Hypermesh (ref. 6)) is being applied successfully at the NASA Glenn Research Center. The building process from structural modeling to the analysis level is outlined in reference 7. Subsequently, a stress analysis of a composite cooling panel under combined thermomechanical loading conditions was performed to validate this process.

Abdul-Aziz, Ali↗

The Liquid Nitrogen System for Chamber A: A Change from Original Forced Flow Design to a Natural Flow (Thermo Siphon) System

NASA Johnson Space Center (JSC) in Houston is currently supplementing its 20K helium refrigeration system to meet the new requirements for testing the James Web Space Telescope in the environmental control Chamber-A (65 dia x 120 high) in Building 32. The new system is required to meet the various operating modes which include a high 20K heat load, a required temperature stability at the load, rapid (but controlled) cool down and warm up and bake out of the chamber. This paper will present the proposed modifications to the existing helium system(s) to incorporate the new requirements and the integration of the new helium refrigerator with the existing two 3.5KW 20K helium refrigerators. In addition, the floating pressure process control philosophy to achieve high efficiency over the operating range (40% to 100% of the refrigeration system capacity), and the required temperature stability of +/- 0.25 K at the load will be discussed. The refrigeration systems ability to naturally seek the operating conditions under various loads and thus minimizing operator involvement and the over all improvements to the system operability and the reliability will be explained.

Homan, Jonathan↗