At least 19 records

User's Manual for RESRAD-BUILD Code Version 4: Vol. 2 - User's Guide for RESRAD-BUILD Code Version 4

The RESRAD-BUILD computer code is designed to assess radiological doses to individuals who live or work in a building contaminated with radioactive material. The code is equipped with a user-friendly interface that has many features to facilitate using the computer code and understanding the results. The design of the interface provides various options, from entering data and performing calculations to displaying calculation results. General and context-specific help are available, providing information on editing and viewing the radionuclide database, the definitions of input parameters and their use in the calculations, and the selection of the calculation results for placement into other applications. Two types of sensitivity analysis are supported by the code, i.e., deterministic and probabilistic, that can be used to study the influence of input parameters on the calculation results. This user’s guide provides instructions to help users on how to install the RESRAD-BUILD code, navigate the interface, and use the various features to set up a dose/risk analysis and to view/print the results in text and graphical outputs.

61 RADIATION PROTECTION AND DOSIMETRY↗

User’s Manual for RESRAD-BUILD Code V.4: Vol. 1 – Methodology and Models Used in RESRAD-BUILD Code

The RESRAD-BUILD computer code models radionuclide release and transport in indoor environments and performs pathway analyses to evaluate the potential radiological dose and risk incurred by an individual who works or lives in a building contaminated with radioactive material or housing radioactively contaminated furniture or equipment. The code provides four geometries to characterize a radiation source: point, line, area, and volume, in which radionuclides are homogeneously distributed. Radionuclides contained in a source are considered to be released to the indoor air due to various processes including erosion (mechanically or weathering), diffusion (for tritium and radon in a volume source), or emanation (radon in a point, line, or area source). The release can proceed through different time phases with different rates. In RESRAD-BUILD Version 4.0, a dynamic ventilation model is implemented to simulate the fate and transport of source material particles and radionuclides after their releases. This dynamic ventilation model considers (1) air exchange between rooms in the building and between the rooms and the outdoor environment, (2) deposition from air to floor, (3) resuspension from the floor to the air, and (4) periodical vacuuming that reduces the floor deposition. The fate and transport modeling provides estimates of radionuclide concentrations in the source, in the air, and on the floor at different times, which are then integrated over the exposure duration for the calculation of radiation doses and cancer risks. A single run of the RESRAD-BUILD code can model a building with up to 9 rooms, 10 sources, and 10 receptors. The potential radiation dose and cancer risk incurred by each receptor are calculated for seven exposure pathways: (1) external radiation directly from the sources (accounting for shielding), (2) external radiation from radioactive particles deposited on the floors, (3) external radiation from airborne radionuclides, (4) inhalation of airborne radionuclides, (5) inhalation of radon and radon progenies, (6) inadvertent ingestion of radioactive particles directly from the source, and (7) ingestion of radioactive particles deposited on the floors. Various exposure scenarios can be modeled with RESRAD-BUILD, including but are not limited to, office worker, renovation worker, decontamination worker, building visitor, and resident. Both deterministic and probabilistic analyses can be performed to obtain results in both text reports and graphic displays.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Monitoring for Volatilized Zinc Contamination Using Gamma-Ray Imaging and Spectroscopy

Gamma-ray imaging is a tool that has grown in importance in the applications of non-destructive assay (NDA) for radioactive survey and analysis of nuclear facilities. Imaging techniques have shown great promise in providing valuable information involving radioactive waste management and contamination prevention. For the application studied in this work, 65 Zn has been identified as a radioactive contaminant during tritium extraction. Due to the volatile nature of 65 Zn under the pressure and temperature changes during extraction operations, 65 Zn can easily travel through components of the extraction system as vapor, making it difficult to trap. Previous research involving the development of a filtration system showed that the 65 Zn can be trapped, mitigating product contamination. However, during the extraction process, direct analysis of the equipment to confirm that zinc contamination is trapped in the filter and has not spread to other components is impractical. Here, in this situation, the need to assay the location of the contamination with little-to-no interference with operations is vital. In this work, we demonstrate the use of a commercialized 3D position-sensitive CdZnTe (CZT) gamma-ray imaging spectrometer to provide analysis of the 65 Zn contamination. Onsite measurements during an extraction process are studied to assess the location and migration of the 65 Zn. The results obtained from real-time glovebox monitoring demonstrate the feasibility of gamma-ray imaging for localizing the contamination and providing a preliminary qualitative assessment that is intended to be used in future work quantifying the contamination build-up and activity over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of RESRAD-BUILD Code Version 4

This report documents the verification of the RESRAD-BUILD code, Version 4.0, which was released on December 22, 2022. Two earlier reports verifying Versions 3.0 and 3.1, respectively, were published in 2001 (Kamboj, et al. 2001) and 2003 (Tetra Tech NUS 2003). Version 4.0 of the RESRAD-BUILD code has many new features and modeling enhancements over the earlier versions, including the previously released Version 3.5. Chapter 2 of this report focuses on verifying the external dose and risk modeling for point, line, area, and volume sources, as well as for floor deposition. Besides verification, the external radiation doses calculated by RESRAD-BUILD were also benchmarked with those calculated by the MCNP code (Briemeister 1993). Section J.3 of the RESRAD-BUILD User’s Manual Vol. 1 (Yu et al. 2022) documents the results of that benchmarking effort. Chapter 3 of this report focuses on verifying the ventilation modeling, from checking the remaining source inventory, releases of radionuclides to the air, air concentrations and deposited floor concentrations over time, to the radiation dose and risk associated with inhalation, ingestion, and air submersion, with and without vacuuming. The verification efforts involve designing spreadsheets to perform calculations the same as or like those performed by the RESRAD-BUILD code and then comparing the spreadsheet results with those produced by the code. When the results agree or the differences are within acceptable range, the accuracy of model implementation in the code is verified. In addition to model implementation, the implementation of key functions and features that facilitate the modeling or the use of the code were also verified during the release testing of the code. Appendix A presents the test cases developed for these verification testing, and Appendix B presents the testing results that verify proper implementation of key functions and features.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the Degradation Mechanisms of Cu Electrodes during the CO 2 Reduction Reaction

Catalyst degradation and product selectivity changes are two of the key challenges in the electrochemical reduction of CO 2 on copper electrodes. Yet, these aspects are often overlooked. Here, we combine in situ X-ray spectroscopy, in situ electron microscopy, and ex situ characterization techniques to follow the long-term evolution of the catalyst morphology, electronic structure, surface composition, activity, and product selectivity of Cu nanosized crystals during the CO 2 reduction reaction. We found no changes in the electronic structure of the electrode under cathodic potentiostatic control over time, nor was there any build-up of contaminants. In contrast, the electrode morphology is modified by prolonged CO 2 electroreduction, which transforms the initially faceted Cu particles into a rough/rounded structure. In conjunction with these morphological changes, the current increases and the selectivity changes from value-added hydrocarbons to less valuable side reaction products, i.e. , hydrogen and CO. Hence, our results suggest that the stabilization of a faceted Cu morphology is pivotal for ensuring optimal long-term performance in the selective reduction of CO 2 into hydrocarbons and oxygenated products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

International Workshop on Security of Radioactive Sources during Extraordinary Events

On May 2, 2019, a subcontractor to Los Alamos National Laboratory (LANL) inadvertently breached a sealed Cs-137 source while attempting to remove the source for disposition as part of a United States (US) government-sponsored program. The source breach resulted in contamination of personnel, the building, and a release of material to the local environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The QUIC Start Guide (V.6.4.9)

QUIC stands for the Quick Urban & Industrial Complex (QUIC) dispersion modeling system. QUIC is a fast response urban dispersion model that runs on a laptop. QUIC is comprised of a 3D wind field model called QUIC-URB, a transport and dispersion model called QUIC-PLUME, and graphical user interface called QUIC-GUI. QUIC also includes QUIC-PRESSURE to solve for pressure fields in and around buildings, a population exposure assessment tool called QUIC-POP, and an indoor infiltration calculator for computing indoor concentrations. Transport and dispersion for different types of airborne contaminants can be computed on building to neighborhood scales in tens of seconds to tens of minutes. QUIC will never give perfect answers, but it will account for the effects of buildings in an approximate way and provide more realism than non-building aware dispersion models.

97 MATHEMATICS AND COMPUTING↗

Perspectives on Response to an Abnormal Radiological Event [Slides]

On May 2, 2019, a sealed radioactive source containing cesium-137 was breached at the University of Washington Harborview Research and Training (HRT) Building in downtown Seattle while attempting to recover the source for the National Nuclear Security Administration’s (NNSA’s) Off-site Source Recovery Program (OSRP). The breach of the source resulted in the contamination of personnel, large sections of the building, and a release of material to the local environment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Solvent-mediated contaminant removal from plastic waste using thermodynamic modeling

Plastics recycling is hindered by the compositional complexity of plastic waste, which can include numerous polymer components as well as low concentrations of additives and non-intentionally added substances. These latter small-molecule species, which we collectively refer to as contaminants, can harm human health and will build up in recycled plastic causing environmental and downstream processing challenges if not removed. In this work, we present molecular modeling approaches using the COnductor-like Screening MOdel for Real Solvents (COSMO-RS) to guide the selection of solvents that are capable of removing targeted contaminants from plastic waste. By considering the thermodynamic partitioning of contaminant species between a solvent phase and polymer phase, we identify guidelines for solvent selection to promote either the low-temperature extraction of contaminants from plastic waste or the removal of contaminants as part of a dissolution-based plastics recycling process. We present four case studies to illustrate the application of the computational approach to the removal of brominated flame retardants, phthalates, and selected perfluoroalkyl substances, and compare to both literature and newly collected experimental data to illustrate model prediction accuracy. Furthermore, the case studies highlight the capability of the modeling approach to help design recycling processes that explicitly account for contaminant removal, thereby increasing product purity during dissolution-based recycling or facilitating chemical recycling of contaminant-free plastics.

Zhou, Panzheng [University of, Wisconsin, Madison,↗

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Evaluation of the Radioactive Material Release in the Harborview Research and Training Building and Implications for Emergency Response

On May 2, 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a Mobile Hot Cell (MHC) on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%) was released from the Mobile Hot Cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy's Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. The implications for emergency response are relevant to data quality and management. A Data Quality Objective (DQO) guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and sample archival.

61 RADIATION PROTECTION AND DOSIMETRY↗

AirflowNetwork

AirflowNetwork is a C++ implementation of the pressure network approach to bulk air movement and contaminant transport, primarily in the context of buildings. It is a descendant of NIST AIRNET (the precursor to NIST's CONTAM) and COMIS. This modeling technique divides the building's total volume up into a set of well-mixed zones that communicate via airflows through openings that are part of the building. Parts of this code have been extracted from EnergyPlus (U.S. DOE's whole building energy simulation program) and other parts are new development.

DeGraw, Jason [Oak Ridge National Lab. (ORNL), Oak↗

Building 100 Groundwater Bioremediation at the Former DOE Pinellas Plant, Florida: Review of Progress and Opportunities

Weapons research, development, and production operations at the former Pinellas Plant, which includes the Building 100 area, released chlorinated organic solvents into the subsurface, contaminating the underlying soil and groundwater. The site was sold to Pinellas County and is now home to a thriving industrial park known as the Young - Rainey Science, Technology, and Research (STAR) Center. The US Department of Energy (DOE) has applied bioremediation at the Building 100 Area as a key technology to clean up the chlorinated volatile organic compound (cVOC) contamination in soil and groundwater. The monitoring data indicate significant progress toward remedial objectives over the past two decades. Starting conditions in the 1980s-1990s included areas containing residual undissolved dense nonaqueous phase liquids (DNAPLs) and the associated presence of an extensive high concentration plume in the groundwater. The original parent cVOCs were primarily tetrachloroethene (PCE) and trichloroethene (TCE). After several informative pilot studies, bioremediation was implemented at the Building 100 Area of the site and relies on reductive biological pathways and the sequential removal of chlorine from the parent cVOCs forming dichloroethane (DCE) and chloroethene (vinyl chloride, VC). As bioremediation sites evolve toward cleanup, the trends in VC concentrations often serve as a critical indicator for progress and remediation timeframe because VC typically has a lower concentration target remedial objective (nominally 1 to 2 μg/L) compared to PCE and TCE (nominally 3 to 5 μg/L).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of the Resuspension of Radioactively Contaminated Particles by Vehicle and Pedestrian Traffic—Current Theory, Practice, Gaps, and Needs

Here, the resuspension of radioactively contaminated particles in a built environment, such as from urban surfaces like foliage, building exteriors, and roadways, is described empirically by current plume and dosimetry models used for hazard assessment and long-term risk purposes. When applying these models to radiological contamination emergencies affecting urban areas, the accuracy of the results for recent contamination deposition is impacted in two main ways. First, the data supporting the underlying resuspension equations was acquired for open, quiescent conditions with no vehicle traffic or human activities, so it is not necessarily representative of the urban environment. Second, mechanical disturbance by winds in urban canyons and during emergency operations caused by vehicle traffic and human activities are not directly considered by the equations. Accordingly, plume and dosimetry models allow the user to input certain compensating values, but the models do not necessarily supply users instructions on what values to use. This manuscript reviews the available literature to comprehensively and consistently pool data for resuspension due to mechanically induced resuspension applicable to urban contamination. Because there are few studies that directly measured radioactive resuspension due to vehicles and pedestrians, this review novelly draws on a range of other studies involving non-radioactive particles, ranging from outdoor air pollution emissions to indoor allergen transport. The results lead to tabulated, recommended values for specific conditions in the emergency phase to help users of plume and dosimetry models maintain the conservativeness needed to properly capture the potential radiation dose posed by mechanically induced resuspension. These values are of benefit to model users until better data are available. The results also suggest the types of data that may result in improved plume and dose modeling.

61 RADIATION PROTECTION AND DOSIMETRY↗